Engineering PapersSearch

SEARCH · Engineering Papers

Results for “X-RAY FLUORESCENCE SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessing Metal Ion Assignment Accuracy in Protein Data Bank Models via Elemental Spectroscopy

Accurate representation of metal ions in macromolecular structures is critical for chemical interpretation, computational modeling, and machine-learning methods that rely on Protein Data Bank (PDB) entries. However, the elemental identity of metals modeled in crystallographic structures is often inferred indirectly and rarely validated experimentally. Here, we combine Particle Induced X-ray Emission (PIXE) and X-ray Fluorescence Spectroscopy (XRFS) to determine the elemental composition of protein samples used to generate 70 deposited metalloprotein crystal structures. By analyzing the original protein material employed for crystallization, but before the addition of crystallization buffer solutions, we assess whether the modeled metal ions in deposited structures are consistent with experimentally detectable elemental content. We find that in a majority of cases, the metals modeled in the corresponding PDB entries are inconsistent with the metals present in the protein samples before crystallization, or that additional metals are present but not represented in the structural models. Spectroscopic results were integrated with automated crystallographic validation metrics, including real-space Z-difference (RSZD) analysis and systematic rerefinement, to evaluate atomic-number mismatch at metal sites. PIXE and XRFS show strong agreement for dominant elemental signals and provide complementary, scalable approaches for identifying suspect metal assignments. This work does not address physiological or functional metalation but instead highlights a widespread data integrity issue in deposited macromolecular structures, PDB-wide. These results establish an experimentally corroborated link between elemental identity and crystallographic validation metrics, enabling the large-scale detection of chemically inconsistent annotations in structural databases used for computational modeling and machine learning.

Crystallization

A Review of Advanced Characterization Methods and Techniques for Amorphous and Poorly Crystalline Materials Applicable to Cementitious Waste Forms

This review covers advanced characterization methods of cementitious materials. The particular focus is to understand cementitious compositions with amorphous content because conventional techniques such as X-ray diffraction are more applicable to materials with long range order. Also of interest is advanced characterization that provides deeper insights into properties such as porosity. There are five groups of characterization methods discussed in this review which are: electron beam/microscopy, X-ray, neutron diffraction and scattering, nuclear magnetic resonance, and optical techniques. The techniques can be further grouped by the categories of nanoscale structural understanding (transmission electron microscopy and pair distribution function), microscale structural understanding (focused ion beam and x-ray tomography), microscopic elemental distributions (energy dispersive spectroscopy and X-ray fluorescence), and chemical binding information (electron energy loss spectroscopy, x-ray absorption spectroscopy, nuclear magnetic resonance, Raman spectroscopy, and infrared spectroscopy), with advantages and disadvantages of each method discussed. The recommendation for further research is to begin with techniques that are easier to prepare samples for, measure, and analyze, such as the optical techniques of Raman and infrared spectroscopy. If more information is needed, pursue collaborations, other techniques, or proposals for beam time at the synchrotron sources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE

Measurements and Analyses to Enable Science for the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE)

Coastal cities provide the opportunity to characterize the substantial effects of manmade particles on marine cloud properties and processes. La Jolla lies to the north of San Diego, California, but it is often about a day directly downwind of the major pollution sources located in the ports of Los Angeles and Long Beach. The large dynamic range of aerosol particle concentrations combined with the multi-hour to multi-day persistence of stratocumulus cloud layers makes the site ideal for investigating the seasonal changes in cloud and aerosol properties as well as the quantitative relationships between cloud and aerosol properties. The Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) characterized the extent, radiative properties, aerosol interactions, and precipitation characteristics of stratocumulus clouds in the Eastern Pacific across all four seasons at two coastal sites in La Jolla. This project was designed to enhance and expand the scientific uses of the ARM AMF1 measurements from EPCAPE. The goal was to ensure meaningful observations were collected that would enable science. The project included the following objectives: (1) Reviewing the ARM AMF1 measurements [ARM, 2021a; b] and circulating a summary of the measurements each week, (2) Comparing AMF1 measurements to those provided by collaborators (including filter measurements at the pier), (3) Collecting and analyzing filter samples from Scripps Pier by Fourier Transform Infrared spectroscopy (FTIR) and X-ray Fluorescence (XRF), (4) Assisting in operations of instruments provided by Guest PIs when possible, and (5) Providing an initial compilation of EPCAPE aerosol and cloud seasonal differences. The expected outcomes of these objectives were enhanced proposals and publications using EPCAPE measurements by helping to identify instrument issues, expanded data access and awareness by distributing weekly plots and related summaries, improved source-related attribution of aerosols with elemental tracers, additional observations provided by Guest PIs, and accelerated ACI studies enabled by the compiled seasonal summaries of aerosol and cloud properties. Three examples of the science enabled by this project are findings that (i) aerosol and cloud aqueous production contributes more than half of sulfate particle mass concentration, (ii) upwind sources make chemical composition very similar at nearby sites despite local differences in meteorology, and (iii) most of the large mass concentration of semi-volatile organic components is co-emitted and co-evaporated with nitrate. Together these findings illustrate how ARM extended field campaigns in coastal regions can be used to constrain ACI processes with direct observations. By using the unique ARM suite of cloud radiative products in addition to the measured aerosol properties at a coastal location, we were able to address the more specific question of which aerosol particles cause how much of the effects on clouds. Identifying this signature in coastal areas provides an opportunity to test the representation of aerosol sources by global models in a range of clean and urban-influenced conditions.

Russell, Lynn [Univ. of California, San Diego, CA

MapsTorch : automatic differentiation for X-ray fluorescence data analysis

X-ray fluorescence (XRF) is a popular spectroscopy technique for elemental analysis. Spectrum fitting and parameter tuning are at the core of XRF analysis and are conventionally manually intensive, especially for synchrotron experiments involving large amounts of diverse samples. This work introduces the automatic differentiation (AD) technique to XRF and an open-source package called MapsTorch. By transforming an analytical model of the XRF spectrum into a differentiable computation graph with AD, MapsTorch enables robust optimization of parameters and elemental intensities. We evaluate MapsTorch by conducting computational experiments on a large number of historical synchrotron XRF datasets and compare its performance with the currently practiced fitting tool NLopt. The results show that MapsTorch consistently achieves high-quality fits and often leads to better fitting quality than NLopt, particularly in tasks such as initial spectrum fitting and elemental intensity refinement. The robust performance of MapsTorch paves the way for developing automated and high-throughput XRF data analysis workflows to handle the increasing data volumes expected from next-generation synchrotron facilities.

X-ray fluorescence

X-Ray Absorption Spectroscopy in High Temperature Oxidation of Metals and Alloys

An experimental technique is described that allows for the joint study of the kinetics and of the oxide structure during the high temperature oxidation of metal surfaces. Oxygen is supplied at the metal through an electrochemical oxygen pump and the oxygen pressure, at the metal surface, is measured during oxidation by a YSZ (yttria stabilized zirconia) oxygen sensor. XAS (x-ray absorption spectroscopy) is performed in fluorescence mode at the cation K edge and after each oxidation step. An appropriate analysis of the XAS spectra could provide information on both the oxidation kinetics and oxide structure. Experimental data on the high temperature oxidation of nickel, cobalt, and Fe(64%)Ni(36%) alloy, at low oxygen pressure, are reported and analyzed according to the proposed data reduction. These results indicate the presented technique to be particularly suitable for studying the hot corrosion of oxide film too thick for common surface spectroscopy (AUGER, ESCA) and too thin for conventional thermogravimetric technique.

Daniele Gozzi

Pressure-Induced Stabilization of Terbium(IV) in CsTb(CrO 4 ) 2 Characterized by X-ray Absorption Spectroscopy

Single crystals of CsTb(CrO 4 ) 2 and CsDy(CrO 4 ) 2 , where the lanthanide metals are in the trivalent state under ambient conditions, have been investigated under high-pressure conditions on the gigapascal scale utilizing a diamond anvil cell. These compounds were characterized by single-crystal X-ray diffraction in addition to high-pressure solid-state UV-vis-NIR spectroscopy, Raman spectroscopy, and Tb L 3 -edge highenergy- resolution fluorescence-detected X-ray absorption near-edge structure (HERFD-XANES). The high-pressure UV-vis-NIR spectra reveal strong broadening of the metal-to-ligand charge transfer band to lower energies, associated with a visible color change from yellow to dark red/black. Clear evidence for the stabilization of Tb 4+ under high pressure is provided by the appearance of a second edge feature characteristic of Tb 4+ , starting at 19.62 GPa in the high-pressure L 3 -edge HERFD-XANES at around 7528 eV. This represents the first example of Tb 4+ being stabilized by high pressure and expands upon the limited chemistry of terbium in the tetravalent state.

Anions

Mechanistic transition of stainless steel 304L corrosion in MgCl 2 phase change material under thermal cycling

Magnesium chloride (MgCl 2 )-based molten salt phase change materials (PCMs) are promising candidates for thermal energy storage (TES) owing to their advantageous thermophysical properties, however, their high corrosivity in the molten state limits material compatibility. In this study, the corrosion behavior of 304?L stainless steel (SS304L) exposed to MgCl2 PCM was investigated as a function of thermal cycling (up to 9000 cycles) relevant to PCM-based TES systems. Microstructural changes and elemental redistribution at the alloy-salt interface under thermal cycling conditions were characterized using synchrotron-based X-ray fluorescence (XRF) and scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDS). Results show that corrosion is governed by selective Cr-dissolution and elemental diffusion near the interface and grain boundaries. A clear transition in the dominant corrosion mechanism is observed with increasing thermal cycles. Surface corrosion is the dominant mechanism up to 1000 cycles, whereas intergranular corrosion becomes the primary degradation mode beyond 2000 cycles. These mechanistic changes are interpreted in terms of evolving interfacial chemistry, microstructure and the diffusion-driven redistribution of alloying elements.

36 MATERIALS SCIENCE

Effect of glutathione-coated Mn-doped ZnS quantum dots on nutrient delivery in basil ( Ocimum basilicum ) plants

Ensuring efficient nutrient delivery while minimizing environmental impacts remains a significant challenge for modern agriculture. Nanotechnology-based fertilizers offer promising strategies to improve nutrient uptake and bioavailability in plants. This research aims to evaluate the use of Glutathione-coated Manganese-doped Zinc Sulfide quantum dots (GSH-ZnS-Mn QDs) as a potential nano fertilizer for basil (Ocimum basilicum). QDs' physicochemical properties were characterized using UV–Vis spectroscopy, photoluminescence, FTIR, and energy-dispersive X-ray spectroscopy, confirming successful Mn doping and glutathione surface functionalization. Basil plants were exposed to different concentrations of GSH-ZnS-Mn QDs under soil and hydroponic conditions. Plant growth parameters, oxidative stress responses, photosynthetic pigments, and macro- and micronutrient uptake were assessed using biochemical assays and inductively coupled plasma optical emission spectrometry (ICP-OES). Elemental uptake, spatial distribution, and zinc speciation were further investigated using synchrotron-based micro-X-ray fluorescence (μ-XRF) imaging and X-ray absorption near-edge structure (XANES) spectroscopy. Results show that exposure to GSH-ZnS-Mn QDs resulted in a concentration-dependent increase in leaf and stem biomass, accompanied by enhanced Zn accumulation in plant tissues. Catalase activity decreased across all tested concentrations, suggesting a shift toward glutathione-dependent antioxidant pathways rather than oxidative damage. Chlorophyll levels exhibited moderate reductions at higher concentrations. The higher increase in macronutrient (K, Ca, and Mg) uptake was reported in plants exposed to 200 ppm of QDs. μ-XRF imaging indicated a selective accumulation of Zn in roots and stems, with partial translocation to leaves. XANES analyses revealed that Zn from QDs was mainly converted into organic Zn species, such as Zn-phytate, Zn-acetate, and Zn-cysteine, indicating transformation and complexation within the plant. The findings demonstrate that a glutathione coating on GSH-ZnS-Mn QDs improves biocompatibility and nutrient delivery efficiency. These results highlight the relevance of surface functionalization in regulating nanoparticle fate, transformation, and nutrient bioavailability, supporting the potential application of GSH–ZnS–Mn QDs as modern nano fertilizers.

Basil

Synthesis and composition control of epitaxial FeWO4 thin films using pulsed laser deposition

We report the growth of epitaxial FeWO4 thin films on c-plane sapphire via pulsed laser deposition using a Fe 2 O 3 /WO 3 target ablated in an O 2 atmosphere. At a constant O 2 pressure of 1 mTorr, x-ray diffraction (XRD) confirms FeWO 4 as the major crystalline phase for substrate temperatures from 500 to 800 °C. As temperature increases, x-ray fluorescence (XRF) shows the Fe/W ratio remains nearly constant at 0.90 ± 0.02, while x-ray photoelectron spectroscopy (XPS) shows Fe 3+ to Fe 2+ conversion increases from 20% to 35%. Morphological analysis reveals phase separation, likely of amorphous Fe 3+ oxide from crystalline FeWO 4 , increasing with Fe 3+ conversion. This is attributed to an O-rich laser ablated flux, where conversion is driven by the Arrhenius temperature dependence of Fe 3+ → Fe 2+ reduction on the film surface. At a constant substrate temperature of 750 °C, XRD confirms FeWO 4 formation for O 2 pressures from 0.5 to 10 mTorr. As pressure increases, XRF shows the Fe/W ratio decreases from 0.98 to 0.70, while XPS shows Fe 3+ conversion rises from 15% to 70%. Morphology shows phase separation decreasing with increasing Fe 3+ conversion. This is attributed to scattering, where higher O 2 pressure makes the laser ablated flux O-deficient relative to Fe and W, facilitating Fe 2+ formation. Films with Fe 3+ conversion above ∼30% and Fe/W ratios from 0.86 to 0.96 exhibit FeWO 4 optical and electronic properties suitable for photoanode applications.

36 MATERIALS SCIENCE

Single-Determinant Ground State in Ce 4+ Imidophosphorane Complexes

X-ray spectroscopy techniques are critical in the electronic structure analysis of high-valent lanthanides. The interpretation of multipeaked features at the lanthanide L 3 -edge has remained a challenging question, as it is observed across a range of material classes. A series of structurally related Ce 4+ complexes were prepared to probe the potential ligand field perturbation of the ground state within the series. The tuning of relative 4f and ligand orbital energies in homoleptic and heteroleptic tetravalent Ce imidophosphorane complexes is achieved through ligand derivatization and is clearly demonstrated by UV−vis spectroscopy and electrochemically measured redox potentials. However, Ce L 3 - edge high-energy resolution fluorescence-detected (HERFD) X-ray absorption near-edge structure (XANES) spectra present features at consistent numbers and energies across the range of complexes. Resonant inelastic X-ray scattering (RIXS) is employed to visualize the observed features in the HERFD-XANES spectra. Large complete active space configuration interaction singles and doubles (CASCISD) calculations demonstrate that the ground-state wave function of all complexes can be described employing a single determinant. As a result, the multielectron feature at the L 3 -edge observed in this study for the Ce 4+ imidophosphorane complexes is described as excited-state multiconfigurational behavior that is independent of ligand variation, in systems where the ground state is described using the simple single determinant wave function.

Lanthanides

Ultrafast Laser Welding and Terahertz Time-domain Spectroscopy of Soda Lime Silicate Glass

Joining and welding techniques of similar and dissimilar materials have reached their limits due to the inflexibility of adapting dielectric materials, e.g., glasses and ceramics, reproducibility for transparent materials, and cycle process time. The ability to join pieces of glasses using laser irradiation allows rapid processing of vacuum insulating glass (VIG) for a widening range of commercial energy-efficient applications. We have used a 1064-nm laser wavelength with 15 picoseconds pulse width and a 155-kHz repetition rate to weld commercial plate glass pieces. The welded samples were characterized via x-ray fluorescence (XRF), time-of-flight secondary ion mass spectrometry (TOF–SIMS), polarimetry, and terahertz time-domain spectroscopy (THz-TDS) to determine the integrity of the weld and chemical changes in the welded areas. Our data shows no significant changes in glass chemistry and structure on average over nano- to micro-scales occurred from the welding process within the limits of the characterization tools. Our results demonstrate successful welding of glass plates without significant changes in the glass chemistry, structure, or properties in the laser-modified region or strains in the bulk glass.

Matthies, Kathleen [ORNL] (ORCID:0009000213135441)

Cooperative Lanthanide Solvation in an Ionic Liquid for Critical Materials Separations

Effectively separating critical materials, including intra-lanthanide separations, is crucial for meeting growing application demands. Liquid–liquid extraction (LLE) is the industry standard for lanthanide separations, where the selectivity can depend on small changes in metal coordination. In this work, we investigate representative lanthanide Eu coordination with a neutral malonamide extractant in an imidazolium bistriflimide ionic liquid (IL) solvent. Through systematic titrations of the water and extractant and under extraction conditions, we observe surprising cooperative Eu solvation with the IL anion and extractant. Time-resolved fluorescence spectroscopy measurements show strong extractant coordination in water-saturated IL. Lifetime measurements show no water coordination, and extended X-ray fine structure spectroscopy data provide a coordination number of 10. Molecular dynamics simulations confirm this coordination number and reveal IL anion coordination in the final Eu complex, even though it is ordinarily a significantly weaker ligand compared to water. The lack of water in the final extracted complex and IL anion coordination potentially explain the increased extraction in LLE systems using ILs, as evidenced by higher distribution ratios for cation exchange extraction, despite the energetic cost of cation transfer to the aqueous phase. These results highlight the opportunities for tuning metal coordination to drive extraction in unique solvent systems.

Carr, Amanda J.

Imaging from Macro to Nanoscale: Multimodal Advances in Chemical and Biomedical Imaging

Imaging increasingly serves as a multiscale framework for linking molecular mechanisms to cellular behavior, tissue architecture, and organ phenotypes in biology and unraveling fundamental processes in chemistry, physics and materials science. This Perspective highlights recent advances in chemical and biomedical imaging across macro-, micro-, and nanoscales, using representative examples published in Chemical and Biomedical Imaging (CBMI). At the macroscale, we discuss chemically selective MRI, including endogenous and exogenous CEST strategies, together with photoacoustic imaging as a hybrid modality with functional and chemical contrast. At the microscale, we consider fluorescence, label-free optical and vibrational imaging, and selected X-ray approaches that expand sensitivity, specificity, and temporal resolution in biological and materials systems. At the nanoscale, we highlight super-resolution fluorescence microscopy, single-molecule methods, tip-enhanced Raman spectroscopy, and correlative imaging strategies that resolve local heterogeneity and molecular organization. Across scales, a common theme emerges that advances in probes, contrast mechanisms, instrumentation, and sample handling are enabling chemically informed imaging that connects molecular specificity with biological context.

multiscale imaging

Mesoscale fractal whey protein particles derived from microscale linear-shaped protein assemblies (Part 1): Manufacturing method and particle characteristics

Whey protein isolates (WPI) are widely used in processed foods for their versatile functional properties. Modifying the structural properties of proteins by assembling them into mesoscale or microscale particles may improve their functionality and broaden their applications. This study aims to manufacture and characterize mesoscale whey protein particles (WPP) derived from WPI. Two types of WPP, WPP1 (0.05 mL/min) and WPP2 (0.25 mL/min), were prepared through a multistep approach involving liquid antisolvent (LAS) precipitation, heat treatment, and microfluidization. Liquid antisolvent precipitation was performed by injecting a 20% (wt/vol) WPI dispersion (pH 7) into an ethanol-glycerol mixture (75:25, vol/vol) under laminar flow, followed by heat treatment at 80°C for 20 min as a particle hardening step. This process produced stable fiber- and ribbon-shaped whey protein assemblies (WPA), which served as precursors to WPP. Subsequent microfluidization (150 MPa, 6 passages) reduced the size of WPA, yielding mesoscale WPP with irregular morphologies and a more uniform size distribution, as revealed by microscopy and dynamic light scattering. ζ-Potential and fluorescence labeling indicated higher surface charge and surface hydrophobicity of WPP compared with untreated WPI. The WPP showed internal mass fractal and surface fractal structures at larger length scales, analyzed using small-angle X-ray scattering. Fourier transform infrared spectroscopy demonstrated an increased fraction of intermolecular β-sheets in WPP, suggesting that hydrogen bonding contributed to their formation. Gel electrophoresis confirmed that disulfide bonds served as the primary cross-links stabilizing the WPP structure. Furthermore, turbidity measurements showed that WPP exhibited superior colloidal phase stability compared with untreated WPI and maintained high colloidal stability under both acidic and neutral pH conditions.

Antisolvent precipitation

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION

Measuring X-Ray Emission Line Shapes in Neutral Species for XRISM Calibration

Space X-ray spectrometers such as the Resolve instrument on XRISM require precise calibration in order to interpret the spectra of astrophysical objects. Key components of the calibration are the energy scale and the core line spread function, both of which vary with photon energy. A major issue in the calibration of high-resolution spectrometers is locating good calibrators with well-known and stable intrinsic line shapes. Neutral fluorescence is widely used, but inner-shell transitions in neutral atoms often exhibit complex, poorly documented line shapes that vary with excitation conditions. Here, in this study, we present empirical measurements of K-shell transitions in neutral O and F below 1 keV using an engineering model XRISM calorimeter array, an electron bombardment modulated X-ray source, and an electron beam ion trap (EBIT) to provide a precise energy reference. In addition, we report measurements of the Mo Lα complex with the transition-edge microcalorimeter spectrometer (TEMS), which reveal strong satellite structure and sensitivity of the line shape to the incident exciting spectrum. Together, these results demonstrate the need for empirical line-shape models, highlight the nonstationary nature of neutral fluorescence features, and define a path toward developing transfer standards for XRISM and future precision instruments such as Athena/X-IFU.

Astronomy and AstroPhysics