The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) proposes to install solar photovoltaic (PV) power generation arrays and an associated battery energy storage system (BESS) for the town of Mercury at the Nevada National Security Site (NNSS) in Nye County, Nevada (Figure 1). The purposes of the development of this facility are to support long-term efforts to modernize Mercury and to provide energy-resilient infrastructure and address climate adaptation needs. Because it is within the boundary of the Mercury Historic District (MHD), it is subject to the terms of the Programmatic Agreement Between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada (hereafter referred to as the Mercury PA). An identification and evaluation report prepared for this undertaking determined that a contributing element to the MHD, the Mercury airstrip (26NY15777), is within the APE (Haynes 2024). The Mercury airstrip was developed following the closure of Camp Desert Rock in 1957 and used until late 1963 or 1964 when the Camp Desert Rock Airport was renovated, and the Mercury Bypass road constructed. The town of Mercury and the immediate surrounding area have been determined eligible for listing in the National Register of Historic Places (NRHP) as the MHD (SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992 (Reed 2019). Originally recorded in 2016, 26NY15777 was determined individually not eligible for listing in the NRHP because it lacked sufficient integrity to convey its significance (Palmer 2016). It was subsequently determined in 2018 to be a contributing element of the MHD in an architectural survey of the district (Palmer 2018) and identified in Appendix C of the Mercury PA as a Category I contributing element. However, as per Stipulation IV.B.2, because the airstrip had already been formally evaluated and determined not to be individually eligible for the NRHP in consultation with the SHPO, this categorization was an error. NNSA/NFO reported this to the SHPO in Haynes 2024 and the SHPO concurred on June 11, 2024 (Reed). Accordingly, the airstrip is a Category II Property for the purposes of complying with the Mercury PA. The Mercury airstrip is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA.
The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to construct a solar photovoltaic (PV) energy generation array and an associated Battery Energy Storage System (BESS) in the town of Mercury at the Nevada National Security Site (NNSS) in Nye County, Nevada. The purposes of the development of this facility are to support long-term efforts to modernize Mercury and to provide energy-resilient infrastructure and climate adaptation needs.
Large scale solar farms supply an increasing amount of the worlds electricity supply. However, high operation temperatures can strongly reduce efficiency and panel lifetime, negatively affecting the levelized cost of energy. In this work, the convective heat transfer coefficient for a utility-scale solar farm is studied with combined thermal and particle-image-velocimetry measurements in a scaled wind tunnel experiment. The measurements confirm the applicability of the scaled experimental setup to study large solar arrays. The velocity measurements indicate the complex flow structure within the solar array, governed by wakes directed upwards due to the orientation of the solar panels.
Solar-tracking photovoltaic arrays are susceptible to aeroelastic fluttering during high-wind events. This dynamic fluttering behavior can grow in amplitude until the panels enter an unstable mode known as torsional galloping which can lead to panel failure or total array destruction. To better understand the physics of the torsional galloping phenomenon and to inform the discussion around panel design and recommended panel stow positions during high wind events, a fluid-structure interaction solver composed of a simulated atmospheric boundary layer with simplified panel structural responses was designed. The simulation choices and features of this solver were informed by the geometry and physical properties of an experimental panel array known to exhibit torsional galloping behavior during hind-wind events. Furthermore, these simulations revealed that the torsional galloping instability is driven by a combination of cyclic vortex shedding from the sun-facing side of the panel and the elastic properties of the torque tube linking the panel assemblies. Testing different stow angles across a range of wind speeds indicates that panels are generally more stable when stowed at negative angles where the leading edge is closer to the ground, hypothesized to be due to ground-blocking effects. These results are supplemented by a discussion of stability trends noted during testing and possible implications when considering multi-row array interactions.
Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.
The Match-E-Be-Nash-She-Wish Band of Pottawatomi Indians, d.b.a. Gun Lake Tribe (Gun Lake Tribe/Tribe), installed a grid connected 68.87 kW solar photovoltaic array at the Tribe’s Jijak Property located in Hopkins, MI. The array generated 95,070 kWh its first year of operation, 7,014 kWh more than projected. The Jijak Gises solar array saved $\$$12,214 during the first year of production including $\$$6,022 in generation credit and $\$$6,192 in offset electrical cost. The array will save the Tribe more than $\$$312,000 with increasing electric rates during the normal life of the system reducing Gun Lake Tribe’s reliance on other energy resources. Competitive pricing allowed the Tribe to install a second smaller array to power the Jijak Garden. The 4.85kW Jijak Garden Array produced 6,643.96 kWh during its first year of production, 475.95 kwh more than projected saving $\$$1,126 during year one of production including invoice credits and offset energy consumption. Over the first 20 years of the array, it is expected to produce 132,879 kWh of electrical energy, saving over $26,000 over the life of the system.
In this study, we explore how the energy and capacity values of coupled systems comprising solar photovoltaic arrays and battery storage (PV-plus-battery systems) could evolve over time based on the evolution of the bulk power system. Using a price-taker model with simulated hourly energy and capacity prices projected from the present to 2050, we simulate the revenue-maximizing dispatch of a range of DC-coupled PV-plus-battery configurations in three locations in the United States. These configurations are defined by the inverter loading ratio (ILR, the ratio of the PV array capacity to the inverter capacity, which we vary from 1.4 to 2.6) and the battery-inverter ratio (BIR, the ratio of the battery power capacity to the inverter capacity, which we vary from 0.25 to 1.0). Based on each configuration's total value, we estimate the breakeven costs needed to justify each incremental increase in ILR (holding BIR constant) or BIR (holding ILR constant). We find that, in a future with low-cost renewable energy technologies, PV-plus-battery system ILRs can be economically increased to around 2.0-2.4 at a BIR of 1.0, depending on solar resource. Our results indicate that a likely evolution of PV-plus-battery system design will be increasingly greater battery power capacity to mitigate the declining PV capacity value, which will, in turn, enable increasingly higher ILRs to further increase energy value. The extent to which PV-plus-systems will be deployed with increasingly higher ILRs depends primarily on whether PV cost declines outpace declining value and increasing curtailment over time.
The split incentive problem is particularly pronounced in rental markets, where landlords prioritize investments that directly increase property value or rental income. Since energy savings from solar photovoltaic (PV) systems primarily benefit tenants, landlords may perceive little return on investment unless mechanisms exist to recapture some of the financial gains. The primary objective of this project is to develop a publicly available, web-based tool to analyze the U.S. Department of Energy’s ResStock database, which models the U.S. residential building stock. The tool allows users to filter buildings by location, type, HVAC system, square footage, and other characteristics, and outputs typical electric load profiles. By leveraging location-specific electric load data, Fram Energy aims to advance business strategies that address the split incentive barrier and promote the adoption of solar PV installations in rental properties. In addition, a machine learning model will be developed to weigh the marginal contribution of building features across the dataset in predicting electricity demand, supporting guided decision making in forecasting electric load profiles. Lastly, based on each building’s location, load profile, and utility’s electricity rate, an optimized solar photovoltaic array and battery energy storage system will be sized to provide energy arbitrage opportunities.
Abstract Global declines in insect populations have important implications for biodiversity and food security. To offset these declines, habitat restoration and enhancement in agricultural landscapes could mutually safeguard insect populations and their pollination services for crop production. The expansion of utility-scale solar energy development in agricultural landscapes presents an opportunity for the dual use of the land for energy production and biodiversity conservation through the establishment of grasses and forbs planted among and between the photovoltaic solar arrays (‘solar-pollinator habitat’). We conducted a longitudinal field study across 5 years (2018–2022) to understand how insect communities responded to newly established habitat on solar energy facilities in agricultural landscapes by evaluating (1) temporal changes in flowering plant abundance and diversity; (2) temporal changes in insect abundance and diversity; and (3) the pollination services of solar-pollinator habitat by comparing pollinator visitation to agricultural fields near solar-pollinator habitat with other agricultural field locations. We found increases over time for all habitat and biodiversity metrics: floral rank, flowering plant species richness, insect group diversity, native bee abundance, and total insect abundance, with the most noticeable temporal increases in native bee abundance. We also found positive effects of proximity to solar-pollinator habitat on bee visitation to nearby soybean ( Glycine max ) fields. Bee visitation to soybean flowers adjacent to solar-pollinator habitat were comparable to bee visitation to soybeans adjacent to grassland areas enrolled in the Conservation Reserve Program, and greater than bee visitation to soybean field interior and roadside soybean flowers. Our observations highlight the relatively rapid (<4 year) insect community responses to grassland restoration activities and provide support for solar-pollinator habitat as a feasible conservation practice to safeguard biodiversity and increase food security in agricultural landscapes.
Fast charging stations (FCSs) for electric vehicles (EVs) can behave as constant power loads, which is problematic for the operation of grid-forming (GFM) inverter-based resources (IBRs). To tackle this problem, this paper proposes a control suite that makes FCSs responsive to ac voltage and frequency disturbances. To test the performance of the FCS controls, the paper also sets forth theory to compensate for time-delays appearing in the real-time simulation of microgrid models divided into several central processing units (CPUs). Furthermore, these contributions are showcased via multi-CPU real-time simulations of a faulted microgrid having EV FCSs and GFM IBRs powered by photovoltaic solar arrays as well as power hardware-in-the-loop experiments. These contributions are significant to address NERC recommendations and IEEE standards.
Particle-laden flows in solar photovoltaic (PV) systems are inevitable, where wind-swept debris in open environments are carried by high winds and turbulence, coating panel surfaces or damaging structures. Particle deposition, or soiling, is a well-known issue for large-scale plants which rely on uninhibited solar rays for optimal production. But understanding the mechanisms leading to soiling requires a physical and fluid dynamics-centered focus, since turbulence dominates PV panel wakes and is also known to alter particle concentration and trajectories. This study presents an experimental campaign toward consequences of particle-laden flow between two model PV panels using time-resolved particle image velocimetry. The model array was subjected to varied particle volume fractions, including a tracer particle case and a water droplet case. Characterization of mean velocity, turbulence statistics, and mean kinetic energy within the single phase and, separately, particle phase flows showed modified features due to particle inertia. Images captured at a frequency of 1 kHz in the near wake of the upstream panel allow for a first experimental look at vorticity and convective velocity of vortex structures for single-phase and particle-phase flows which are crucial to debris transport and soiling in PV environments.
Solar-tracking photovoltaic arrays are susceptible to aeroelastic fluttering during high-wind events. This dynamic fluttering behavior can grow in amplitude until the panels enter an unstable mode known as torsional galloping which can lead to panel failure or total array destruction. To better understand the physics of the torsional galloping phenomenon, and to inform the discussion around panel design and recommended panel stow positions during high wind events, a fluid-structure interaction solver composed of a simulated atmospheric boundary layer with simplified panel structural responses was designed. The simulation choices and features of this solver were informed by the geometry and physical properties of an experimental panel array known to exhibit torsional galloping behavior during hind-wind events. These simulations revealed that the torsional galloping instability is driven by a combination of cyclic vortex shedding from the sun-facing side of the panel and the elastic properties of the torque tube linking the panel assemblies. Testing different stow angles across a range of wind speeds indicates that panels are generally more stable when stowed at negative angles where the leading edge is closer to the ground, hypothesized to be due to ground-blocking effects.
Effective integration planning for small, distributed solar photovoltaic (PV) arrays into electric power grids requires access to high quality data: the location and power capacity of individual solar PV arrays. Unfortunately, national databases of small-scale solar PV do not exist; those that do are limited in their spatial resolution, typically aggregated up to state or national levels. While several promising approaches for solar PV detection have been published, strategies for evaluating the performance of these models are often highly heterogeneous from study to study. The resulting comparison of these methods for practical applications for energy assessments becomes challenging and may imply that the reported performance evaluations overly optimistic. The heterogeneity comes in many forms, each of which we explore in this work: the degree of diversity of the locations and sensors (e.g. different satellites, aerial photography) from which the training and validation data originate, the validation of ground truth (manual annotation of imagery vs known solar PV locations), the level of spatial aggregation (e.g. array-level vs regional estimates), and inconsistencies in the training and validation datasets (e.g. different datasets are used for each study and those data are not always made accessible). For each, we discuss emerging practices from the literature to address them or suggest directions of future research. As part of our investigation, we evaluate solar PV identification performance in two large regions: the entire state of Connecticut and the city of San Diego, CA. In Connecticut, we also use 33,114 known parcel-level solar PV installations from Berkeley Lab’s Tracking the Sun dataset to evaluate parcel-level performance and evaluate capacity estimates using 169 municipalities. We also make our code (which we call SolarMapper), pre-trained models, training data, and predictions publicly available and provide a web portal for interactively inspecting each prediction that was made. Here our findings suggest that traditional performance evaluation of the automated identification of solar PV from satellite imagery may be optimistic due to common limitations in the validation process. The takeaways from this work are intended to inform and catalyze the large-scale practical application of automated solar PV assessment techniques by energy researchers and professionals.
The Sicangu Village Solar Project, spearheaded by the Rosebud Sioux Tribe in partnership with GRID Alternatives, aimed to enhance energy sustainability within the community through the installation of a 149 kW community solar Photovoltaic (PV) array and 13 residential rooftop solar PV systems. Located in Todd County, South Dakota, the project addresses longstanding challenges of rising electricity costs and economic disparities faced by the Tribe. By leveraging solar energy production, the project not only reduces electricity expenses for the community, but also serves as a pivotal step towards achieving the Tribe's energy sovereignty goals. Despite encountering interconnection challenges and delays, particularly exacerbated by regulatory and infrastructure complexities, the project has successfully demonstrated the feasibility of solar energy deployment within the community.
The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .
The Naval Construction Battalion Center (NCBC) in Gulfport, Mississippi, and Mississippi Power Company (MPC) have integrated a 15-acre solar photovoltaic (PV) array, battery storage, and backup generation with an innovative microgrid. The Navy and utility teams are helping ensure mission readiness at NCBC while increasing renewable energy generation on the grid in MPC's service area. The NCBC/MPC resilience effort will allow the base to more effectively deploy disaster recovery activities in the event of a grid outage.
Abstract As more land is being utilized for large-scale solar energy projects, there are increasing discussions from stakeholders on how to utilize land under solar panels to promote biodiversity. One path is to plant habitat beneficial to pollinators and other insects, but there have been few long-term studies that examine how different vegetation and seed mixes establish underneath solar panels. This study addresses a scientific gap to determine whether native pollinator seed mixes successfully establish over time under solar arrays using a systematic assessment of eight seed mixes planted at three utility-scale solar sites in Minnesota. We assess establishment with a percent native coverage metric, which is an assessment of native species observations compared to total observations during percent cover analyses in our vegetative test plots. The percent native coverage metric allows for a measurement of how the seed mix established and how the seed mix persists over time. The percent native coverage under and in between the solar photovoltaic (PV) arrays rose from 10% after one year of planting to 58% after three years across all sites, while the native coverage of the full sun control area rose from 9.6% to 70% under the same period, showing that native prairie and pollinator plants successfully established under the array, although to a lesser extent than in full sun conditions. Percent native coverage under the PV arrays rose 5- to 8-fold for each of the three sites from over the course of the study, while the coverage of weeds decreased for all three sites over the same period. Percent native coverage varied by seed mix over the project years, but every seed mix experienced a higher percent native coverage year after year under the PV arrays. Our results did not indicate a difference in establishment across placement within the array; the center, west, and east portions of the areas in between panels had similar establishment rates at two out of three sites, indicating that the same seed mix can be applied throughout the array. Out of 101 plant species seeded, we observed the establishment of 68 species in our vegetative test plots, and we detailed the top 20 observed species to inform future seed mix development. Based on these findings, native pollinator vegetation can establish over time at solar arrays, and it can be suitable for creating habitat at utility-scale solar sites.