Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Solar dynamic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Commercialization of Reflected Target Non-Intrusive Assessment (ReTNA) Tool, for Indoor Optical Analysis of Heliostats

Under HelioCon, NLR began developing a new optical measurement system, called Reflected Target Non-Intrusive Assessment (ReTNA). ReTNA has shown promise towards addressing metrology gaps for heliostat used in concentrated solar thermal (CST) plant. This project is focused on advancing this measurement system from the laboratory into industry, where it can provide valuable information for heliostat developers during research, development, and qualification of a heliostat design, and be used for quality assurance during heliostat manufacture. Over the course of this project, ReTNA was deployed at several commercial heliostat facilities. The system developed and deployed with the primary project partner, Solar Dynamics LLC, is described in detail. The report discusses each project Milestone, the ending status, the achieved value, and how these Milestones improve and qualify the ReTNA measurement tool. Finally, the final report covers the market advancements, path forward, commercial successes, and lessons learned. Final Technical report for TCF Base Technology-Specific project TCF-23-20118, Commercialization of Reflected Target Non-Intrusive Assessment (ReTNA) tool, for indoor optical analysis of Heliostats.

14 SOLAR ENERGY

Ir–Ru Particles Enable Low-Loading Acidic Oxygen Evolution for Integrated Solar Devices

Integrated photoelectrochemical (PEC) devices for water splitting represent a compelling pathway for sustainable hydrogen production, directly converting solar energy into chemical fuels. While alkaline systems have achieved state-of-the-art solar-to-hydrogen (STH) efficiencies above 20% using earth-abundant catalysts, acidic PEC architectures provide unique advantages for compact device integration, fast proton transport, and stable operation under highly dynamic solar conditions. Proton-exchange membrane (PEM)-based configurations enable high current densities, low gas crossover, and rapid ionic response, making them especially well-suited for intermittent, bias-free PEC operation, despite alkaline electrolysis being more technologically mature. A critical limitation of acidic PEC systems remains, the oxygen evolution reaction (OER), which currently relies on scarce and costly iridium catalysts, restricting scalability. Here, in this study, we report a series of low-iridium mixed-metal oxide catalysts synthesized via a surfactant-assisted borohydride reduction method. An optimized Ir 0.5 Ru 0.5 O x catalyst exhibits exceptional intrinsic activity (>400 A g –1 Ir at 1.55 V vs RHE) in 0.1 M HClO 4 and maintains stable operation for over 10 days in an integrated PEC flow-cell. Sustained hydrogen production is achieved at 1.65 V with a total iridium loading of only 0.1 mg cm –2 , substantially below commercial PEM benchmarks. These results demonstrate a viable pathway toward scalable, high-performance acidic PEC hydrogen technologies.

Acidic electrolysis

Power generation forecasting for solar plants based on Dynamic Bayesian networks by fusing multi-source information

A Dynamic Bayesian network (DBN) model for solar power generation forecasting in solar plants is proposed in this paper. The key idea is to fuse sensor data, operational indicators, meteorological data, lagged output power information, and model errors for more accurate short-term (e.g., hours) and mid-term (e.g., days to weeks) power generation forecasting. The proposed DBN augments automated data-driven structure learning with expert knowledge encoding using continuous and categorical data given constraints to represent causal relationships within a solar inverter system. Additionally, an error compensation mechanism is proposed to capture temporal fluctuation. The effectiveness of the DBN on solar power generation forecasting was evaluated by rolling window analysis with one-year testing data collected from a local solar plant. The proposed DBN is compared with four state-of-art methods including support-vector regression (SVR), k-nearest neighbors (kNN), artificial neural network (ANN), and long short-term memory (LSTM) models. The result show that the proposed DBN achieves better accuracy in general, and it is not as data-hungry as some neural network-based models. The proposed DBN is also shown to have robust and consistent forecasting power with different forecasting horizons. The accuracy is 92% - 95% from one hour to one week ahead forecasting.

14 SOLAR ENERGY

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse-Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage-controlled tests. Here we instead investigate perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with phosphonic-acid interface layer MeO-2PACz, with poorer indium-doped tin oxide (ITO) coverage compared to PTAA, exhibit gradual and recoverable degradation under certain stress and recovery conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more degradation than higher currents over shorter periods. Here, combining electrical measurements with spatially resolved photoluminescence imaging, our observations support an ion- and charge-mediated interfacial electrochemical degradation mode.

Degradation

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage controlled reverse-bias tests. Here we instead present an investigation of perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers with better indium-doped tin oxide (ITO) coverage can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with the phosphonic-acid interface layer MeO-2PACz, with poorer ITO coverage compared to PTAA, exhibit soft, gradual, and largely recoverable degradation, regardless of the shading conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more severe degradation than higher currents over shorter periods. Combining electrical measurements with spatially resolved photoluminescence imaging, we argue against shunt formation and instead support an ion- and charge-mediated interfacial electrochemical degradation mode.

Applied Physics (physics.app-ph)

CSP Plant Optimization Study for the California Power Market (“CalCSP”) (Final Technical Report)

Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.

14 SOLAR ENERGY

Analysis of Molten Salt Thermal Energy Storage Tank Sizing and Preheating

Molten Salt Thermal energy storage (TES) is essential for concentrating solar power (CSP) plants, enhancing their capacity factor and dispatchability to ultimately reduce electricity costs. This technology is becoming more important for other technologies including nuclear power, thermal-electrical storage, and concentrating solar thermal (CST). While molten salt TES tanks have been successfully deployed in lower-temperature parabolic-trough plants, the current state-of-the-art central receiver systems operating at temperatures up to 565 degrees Celsius have experienced costly and frequent failures. These failures are associated with the immaturity of the technology and problems in tank design, fabrication, commissioning and, sometimes, aggressive operation. A primary contributing factor is the absence of a dedicated technical standard for high-temperature molten nitrate TES tanks; designers must currently rely on existing codes like API 650 and ASME Section II, which are insufficient because they fail to account for the unique demands of high temperatures, thermal cycling, and transient conditions.

25 ENERGY STORAGE

Thermal Analysis of a Solid Particle Light-Trapping Planar Cavity Receiver Using Computational Fluid Dynamics

Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.

computational fluid dynamics

Dynamic disulfide bond networks enable self-healable and mechanically resilient intrinsically stretchable organic solar cells

A dynamic disulfide network introduced into donor/acceptor blends enables room-temperature self-healing and mechanical resilience in intrinsically stretchable organic solar cells, achieving performance recovery after high mechanical strain. The development of intrinsically stretchable organic solar cells (IS-OSCs) faces significant challenges in balancing mechanical durability and optoelectronic performance. Conventional π-conjugated polymer-based donor/acceptor blend films often exhibit limited stretchability and irreversible performance degradation under mechanical strain. To address these limitations, we propose a novel self-healable donor/acceptor blended film with a dual-network morphology, achieved by incorporating a dynamic disulfide bond-based crosslinked network into the bulk-heterojunction film. The resulting thin films demonstrate a power conversion efficiency (PCE) of 16.39% in rigid OSC devices and a fracture strain of 15.6%. Remarkably, the IS-OSCs retain 80% of their initial PCE under 30% strain and exhibit performance recovery after multiple stretch-release cycles at 40% strain through a room-temperature self-healing process. This work provides a proof-of-concept for highly stretchable and durable IS-OSCs, offering valuable insights for advancing the field of wearable energy systems, adaptive solar textiles, and sustainable electronics.

Yang, Wenyu

Mitigating Band Tailing in Kesterite Solar Absorbers: Ab Initio Quantum Dynamics

Open-circuit voltage deficits are limiting factors in kesterite solar cells. Addressing this issue by suppressing band tailing and nonradiative charge recombination is essential for enhancing the performance. We employ ab initio nonadiabatic molecular dynamics to elucidate the origin of band tailing and charge losses and propose a mitigation strategy. The simulations show that Cu–Zn disorder, associated with antisite defect clusters [Cu Zn +Zn Cu ], is a significant source of band tailing in kesterites, as evidenced by the much larger Urbach energy in disordered than ordered kesterites. Cu–Zn disorder gives rise to new sulfur-centered coordination polyhedra, increases structural inhomogeneity, changes electrostatic potential at sulfur centers, and shifts the S(3p) orbital energy. Differences in the S(3p)/Cu(3d) and S(3p)/Sn(5s) hybridization strengths and the S(3p) orbital energy shift reduce the band gap by 0.37 eV. Furthermore, Cu–Zn disorder enhances vibrational motion of sulfur anions and surrounding cations, increasing band gap fluctuations by 15 meV. The stronger electron–phonon interactions reduce charge carrier lifetimes and limit the kesterite solar cell efficiency. Partial substitution of Zn with Cd facilitates structural ordering and significantly suppresses band tailing, particularly in disordered systems. The improvement can be attributed to the larger atomic radius and mass of Cd, which weakens bonding around the anion, suppresses S-related vibrations within the covalent tetrahedra, and reduces nonadiabatic coupling, thereby increasing charge carrier lifetimes. The reported results establish the key influence of cation disorder on band tailing and reduced charge carrier lifetimes in kesterites and highlight cation disorder engineering as a strategy to achieve high-efficiency kesterite solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Volume 1 Specifications for Parabolic Trough Projects, Volume 2 - Specifications for Central Receiver Projects, Volume 3 - Narrative

Design Basis Documents / Owner’s Technical Specifications are developed for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. The goals were to 1) distill the successful experience with nitrate salt systems from as many commercial projects as possible, 2) provide technical bases for equipment design/selection that an owner can impose on an EPC contractor, 3) compile this information in one location to provide guidance on salt systems that is as broadly applicable to as many projects as possible, and 4) work toward an industry consensus on a Design Basis Document that reflects the lessons learned from earlier commercial projects. The document allows an owner to provide design guidance, and to impose a minimum set of requirements, above and beyond those in the normal Codes and Standards, on an EPC contractor in an effort to avoid a repeat of past mistakes. If successful, this would allow salt systems to achieve the same levels of reliability and availability as commercial parabolic trough plants using diphenyl oxide / biphenyl (i.e., Dowtherm A, Therminol VP-1) as the heat transfer fluid. The report consists of 3 volumes: • Volume 1 - Specifications for Parabolic Trough Projects • Volume 2 - Specifications for Central Receiver Projects • Volume 3 - Narrative Volumes 1 and 2 include discussions of the following topics: • Plant functional requirements for the salt systems • Plant operating states, and transitions between states, for the salt systems • Risk analysis of the principal salt components • Plant requirements for the salt systems to meet the functional and the operating requirements • Type of specification for the principal salt components: functional; or prescriptive • Current state of the art for salt systems. Volume 3 discusses a number of cases in which the salt equipment at commercial parabolic trough and central receiver projects has not met the projected levels of reliability and availability. Possible reasons for the sources of the problems are discussed, as is a range of possible alternate designs that could avoid the known problems.

14 SOLAR ENERGY

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY

Deployment Potential of Concentrating Solar Power Technologies in California

As states within the United States respond to future grid development goals, there is a growing demand for reliable and resilient nighttime generation that can be addressed by low-cost, long-duration energy storage solutions. This report studies the potential of including concentrating solar power (CSP) in the technology mix to support California’s goals as defined in Senate Bill 100. A joint agency report study that determined potential pathways to achieve the renewable portfolio standard set by the bill did not include CSP, and our work provides information that could be used as a follow-up. This study uses a capacity expansion model configured to have nodal spatial fidelity in California and balancing-area fidelity in the Western Interconnection outside of California. The authors discovered that by applying current technology cost projections CSP fulfills nearly 15% of the annual load while representing just 6% of total installed capacity in 2045, replacing approximately 30 GWe of wind, solar PV, and standalone batteries compared to a scenario without CSP included. The deployment of CSP in the results is sensitive to the technology’s cost, which highlights the importance of meeting cost targets in 2030 and beyond to enable the technology’s potential contribution to California’s carbon reduction goals.

14 SOLAR ENERGY