Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Silicon drift detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Measurement of low energy characteristic X-rays emitted present in U-10Mo HALEU alloy fuel

Advance high density monolithic alloy HALEU fuels have been scanned with a silicon drift detector scanning system to measure low-energy characteristic X-rays emitted by uranium daughters, as well as zirconium present as a foil diffusion barrier. Four peaks were measured across the surfaces of three plates, and are consistent with other thorium and protactinium peaks present in depleted uranium samples that are induced by the decay of 235 U and 238 U. Of the four peaks detected, three are dominated by the decay of 235 U, and one peak at 15.70 keV covers two characteristic X-rays from the zirconium diffusion barrier (Kα 1 ) and from a 231 Th 15.62 keV X-ray induced by 235 U α-decay. The low energies of these lines suggest that they are mostly emitted from the fuel meat surface, and the poor counting statistics caused by strong self-attenuation make these data a poor candidate for 235 U/ 238 U ratio analysis. We suggest, then, that these X-rays could be used for passive measurement of variations in the cladding thickness of these fuels to complement manual thickness measurement methods.

HALEU

193 mIr/ 192 Ir ratio from irradiation with various NCERC critical assemblies

Eight irradiations of K 2 IrCl 6 pellets were carried out with three critical assemblies: Flattop-Oy, Flattop-Pu and Godiva IV. One of the irradiations was performed with three pellets at different locations of the critical assembly, while the other irradiations with pellets at the center, but operating the critical assembly at different power and, respectively, different neutron flux. Counting samples were prepared from the irradiated pellets and X-ray spectra measured with silicone drift detectors. The 193 mIr/ 192 Ir ratio is reported for each irradiation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA

X-Ray and Particle Detection With the Si(Li) Tracker Module of the GAPS Experiment

Here, this work describes the architecture and the experimental results from the characterization of the lithium-drifted silicon (Si(Li)) detector module, which constitutes the building block of the tracker in the general antiparticle spectrometer (GAPS) experiment to search for dark matter. The instrument is designed for the identification of low-energy cosmic anti-nuclei (antiprotons, antideuterons, and antihelium) to be performed during an Antarctic long-duration balloon flight scheduled for late 2025. The GAPS Si(Li) tracker, that is the core of the instrument, is the assembly of 252 modules, each comprised of four Si(Li) detectors and a full custom-integrated circuit designed for detector readout and produced in a commercial 180-nm planar CMOS technology. A general overview of the detector module architecture and its components is provided, together with a description of the test setup and the experimental results obtained from the characterization of the low-noise analog readout channel. In order to verify the effective operation of the entire module, results concerning the detection of X-rays from a 241Am source and cosmic muons are also provided.

Manghisoni, Massimo [Università di Bergamo (Italy)

The IDEA detector concept for FCC-ee

A detector concept, named IDEA, optimized for the physics and running conditions at the FCC-ee is presented. After discussing the expected running conditions and the main physics drivers, a detailed description of the individual sub-detectors is given. These include: a very light tracking system with a powerful vertex detector inside a large drift chamber surrounded by a silicon wrapper, a high resolution dual readout crystal electromagnetic calorimeter, an HTS based superconducting solenoid, a dual readout fiber calorimeter and three layers of muon chambers embedded in the magnet flux return yoke. Some examples of the expected detector performance, based on fast and full simulation, are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Modeling athermal phonons in novel materials using the G4CMP simulation toolkit

Understanding phonon and charge propagation in superconducting devices plays an important role in both performing low-threshold dark matter searches and limiting correlated errors in superconducting qubits. The Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, models charge and phonon transport within silicon and germanium detectors and has been validated by experimental measurements of phonon caustics, mean charge-carrier drift velocities, and heat pulse propagation times. Here, in this work, we present a concise framework for expanding the capabilities for phonon transport to a number of other novel substrate materials of interest to the dark matter and quantum computing communities, including sapphire (Al 2 O 3 ), gallium arsenide (GaAs), lithium fluoride (LiF), calcium tungstate (CaWO 4 ), and calcium fluoride (CaF 2 ). We demonstrate the use of this framework in generating phonon transport properties of these materials and compare these properties with experimentally-determined values where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Q ββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at ~4 bar and drift fields of 74 V cm –1 and 118 V cm –1 , respectively. Alpha decays from the 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

Adams, C. [Argonne National Laboratory; NVIDIA] (O

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods

A High-Precision, Fast, Robust, and Cost-Effective Muon Detector Concept for the FCC-ee

We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements. The drift tubes deliver two-dimensional position measurements perpendicular to the tubes with a resolution around 100~$\mu$m. Meanwhile, the scintillator strips, read out with the wavelength-shifting fibers and silicon photomultipliers, provide fast timing information with a precision of 200~ps or better and measure the third coordinate along the tubes with a resolution of about 1~mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]

Time Resolution Characterization of 4H-SiC LGADs with a 90 Sr Source

This work presents timing measurements of 4H-SiC Low Gain Avalanche Detectors (4H-SiC LGADs) using beta particles from a 90Sr source. The 4H-SiC LGADs exhibit fast signal responses, and a time resolution of 61 ps was achieved, comparable to that of standard Si LGADs. The present limitation in the time resolution of 4H-SiC LGADs appears to stem from limited charge generation. Nevertheless, their higher voltage tolerance and faster carrier drift suggest that, with increased charge collection, their timing performance could approach or even surpass that of Si LGADs. Furthermore, these results demonstrate the strong potential of 4H-SiC LGADs as a robust platform for precision timing in future 4D tracking detectors, while also highlighting that signal charge is the dominant factor currently limiting their performance, indicating that further optimization of gain and drift structures will be essential for future development.

43 PARTICLE ACCELERATORS