Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Power usage effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Investigation of ion irradiation effects on mineral analogues of concrete aggregates

Irradiation can cause prominent damage to reactor concrete aggregates leading to amorphization, strength and modulus decrease, radiation induced volume expansion (RIVE) and micro-cracking, which limits their long-term performance. Here, to develop an improved understanding of irradiation effects in concrete, three mineral analogues of concrete aggregates (limestone, marble and quartzite) were irradiated by 5.5 MeV He ions and 13 MeV Ni ions to surface doses of 0.011 displacements per atom (dpa) and 0.23 dpa, respectively, at room temperature. The two different ion species allow irradiation spectrum effects (ionizing and displacive) to be examined. Irradiation induced cracks were observed in He irradiated limestone and marble, and Ni irradiated quartzite. Full amorphization was observed in Ni irradiated quartzite with 14.3 % RIVE, and ∼25 % hardness and modulus decrease, while almost no change was observed in He irradiated quartzite except 4.35 % RIVE, revealing a possible ionization enhanced diffusion effect for high energy light ions. Furthermore, partial amorphization was observed in Ni irradiated marble and limestone matrix with a 12 % hardness decrease in marble while no amorphization was observed for He irradiation with a 20 % hardness increase in limestone matrix. The role of knock-on damage and irradiation spectrum on amorphization, volumetric expansion and mechanical property changes are discussed. Moreover, the onset and critical doses for amorphization and RIVE in quartz are obtained for ion irradiations at room temperature. The dose dependence of RIVE exhibits a delay compared to the amorphization behavior. The superior irradiation resistance of calcite phase compared to quartz phase implies there could be advantages to using calcareous aggregates and lowering the usage of siliceous aggregates for concrete in nuclear power plants for extended operation beyond 60 years. However, other effects such as corrosion, aging and reactions during severe accidents should also be considered, and further investigations are needed.

Amorphous

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY

Advancements in Manufacturing of High-Performance Perovskite Solar Cells and Modules Using Printing Technologies

Perovskite photovoltaic technology carries immense opportunity for the solar industries because of its remarkable efficiency and prospect for cost-effective production. However, the successful deployment of perovskite solar modules (PSMs) in the solar market necessitates tackling stability-based obstacles, scalability, and environmental considerations. This paper unveils a comprehensive examination of the cutting-edge advancements in the manufacturing of perovskite solar cells (PSCs) and modules, with an emphasis on high-speed, large-area printing. The paper underscores the substantial progress achieved in printed PSCs and PSMs, demonstrating promising electrical performance and long-term device durability. This review paper categorizes printing techniques compatible with large-area high-speed manufacturing into three distinct families: blade coating, slot die coating, and screen printing, as these common printing practices offer precise control, scalability, cost-effectiveness, high resolution, and efficient material usage. Additionally, this paper presents an in-depth investigation and comparison of superior PSCs and PSMs fabricated by printing on power conversion efficiency (PCE), stability, and scalability.

14 SOLAR ENERGY

A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.

14 SOLAR ENERGY

Hydropower Infrastructure - LAkes, Reservoirs, and RIvers (HILARRI), v4

HILARRI is a database of links between major datasets of operational hydropower dams and powerplants, and inland water bodies. These connections are critical for conducting large-scale analysis of hydropower infrastructure and their associated natural and engineered water systems. Features include: – Dams from the National Inventory of Dams (2025) and the Global Reservoir and Dam Database (GRanD v1.3) – Hydropower plants from the Existing Hydropower Assets dataset (EHA 2025) – Power plants that are listed in the 2025 U.S. Hydropower Development Pipeline Data or were listed in previous versions of the dataset These hydropower infrastructure features are linked to several major datasets that provide hydrologic and hydraulic information relevant for analysis of hydropower systems that includes the integral water resources. That information comes from: – Products from the National Hydrography Dataset (NHD) – NHDPlusV2 Medium Resolution river network flowlines, – NHD waterbodies (limited to lakes and reservoirs), – NHD Watershed Boundary Dataset (HUC12-level for the Conterminous United States (CONUS)) – NHD High Resolution waterbodies – HydroLAKES water bodies (lakes and reservoirs) – LAGOS-US lakes and reservoirs – EPA National Lakes Assessment (2007, 2012, 2017, and 2022) – The Reservoir Sedimentation Database (RESSED) – EPA SuRGE sampling locations Unique identifiers are used to facilitate joining to the original full datasets. For example, characteristics of NHD flowlines such as estimated average flow rate can be joined from the NHDPlusV2 dataset to a dam or power plant listed in HILARRI based on the ID field, “COMID”, that is common to both datasets. HILARRI only includes basic information about identifiers, location, and data quality or usage notes. It does not contain the attributes or time series data associated with these sites. The HILARRI dataset incorporates information from several datasets to facilitate more effective and accurate analysis of hydropower infrastructure and their associated waterbodies. For example, dams were checked against the most recent American Rivers Dam Removal Database to identify and flag facilities that may no longer exist. Additionally, dams that are listed multiple times in the NID are identified and flagged to avoid double-counting when analyzing and summarizing information. Other quality flags include certainty of operational hydropower (i.e., if one or more datasets indicates hydropower at a particular location), whether an associated water body is accurate or composed of multiple polygons, or whether there is a known issue with reported characteristics in one of the underlying datasets. These additional data flags are designed to increase confidence in data usage for individual to large-scale analyses.

Hansen, Carly [ORNL] (ORCID:0000000193280838)

Equitable Urban Electric Vehicle Charging: Feasibility and Benefits of Streetlight Charging in Kansas City Right-of-Way

With an increasing global emphasis on sustainability, electric vehicles (EVs) play a crucial role in reducing urban pollution and carbon emissions. For EVs to be widely adopted, equitable and convenient access to charging infrastructure is essential. Equity in this paper refers to the proactive engagement with the community to ensure that the benefits of streetlight charging are distributed equitably across diverse neighborhoods in Kansas City, providing fair charging opportunities and resources to all community members. This research explores the potential of utilizing streetlights—ubiquitous elements of urban electrical infrastructure—as low-cost, equitable EV charging solutions. Compared with conventional chargers, streetlight charging offers several notable advantages, including proximity to roadways, potential boosts to the local economy, and easier usage due to city ownership. These chargers also leverage existing power setups to minimize costs and maximize efficiency by reutilizing existing structures. In this manuscript, we introduce a systematic framework to develop, analyze, and evaluate a scalable and cost-effective streetlight charging solution. Initially, we employ a two-tiered site selection framework that accounts for both charging demand and equity considerations to identify optimal locations for streetlight chargers. We then assess the feasibility of these chargers through observational data from 23 units installed in Kansas City, Missouri, comparing their performance with traditional chargers. Here, our evaluation extends to the environmental impact, comparing reduced gasoline consumption and greenhouse gas (GHG) emission reductions between streetlights and regular charging stations. Our findings reveal that streetlight charging stations offer faster charging speeds than conventional stations, validating their viability for EV charging. Additionally, the duration of stay at streetlight chargers tends to be shorter, likely due to parking constraints or associated costs. Furthermore, streetlight-powered chargers demonstrate considerable environmental advantages, achieving 11.94% greater avoided gasoline consumption and 11.24% higher GHG reductions compared with regular charging stations, highlighting their substantial environmental benefits.

42 ENGINEERING

Exploring Multidimensional Spatial-Temporal Hydropower Operational Flexibilities by Modeling and Optimizing Water-Constrained Cascading Hydroelectric Systems

Because of unique characteristics such as clean and cost-competitive electricity as well as fast-ramping and storage abilities, the power industry continues to evolve its operation strategies for cascading hydroelectric (CHE) systems for providing enhanced values to the grid, especially under the deeper renewable resource integration. However, existing operation practices of CHEs predate the integration of renewables, which could prohibit the effective utilization of their inherent flexibilities in delivering maximum financial benefits and providing valuable grid services to the power system and electricity market operations. Indeed, modeling and optimizing these resource-limited while flexible CHE assets with uncertainties and imperfect information across multiple spatial-temporal dimensions present significant challenges. To facilitate CHE facility operators in effectively coordinating water usage and hydropower plant operations across multiple timescales, this project aims to fill the existing gaps by developing a suite of accurate water inflow (WI) forecast models as well as enhanced CHE modeling and optimization approaches with proper consideration of their unique characteristics, which would help explore their multidimensional spatial-temporal operational flexibility potentials. The developed approaches could better align reservoir operation strategies with variability and uncertainty of future water availability. They can also promote more effective utilization of multidimensional spatial-temporal hydropower operational flexibility potentials by designing long-term evacuation plans of reservoirs and short-term operation of CHEs, along with their coordination with other types of renewables. The project leverages various resources to facilitate the research and development activities, including actual characteristics data of CHE systems and a library of current and future cases of Portland General Electric (PGE). These realistic data enable the project team to study how to maximize the value of CHEs under current and future portfolios and evaluate opportunities to improve operation practices.

13 HYDRO ENERGY

Demand response of loads having thermal reserves

Systems and methods are described herein that improve grid performance by smoothing demand using thermal reserves. The smoothed demand can reduce peak loads as well as the ramp rate of demand that will otherwise require the use of inefficient, expensive generation sources. These improvements are tied to the selective switching on or off electrical loads that are coupled to thermal reserves, effectively using the thermal reserves as an energy storage mechanism. Historical data of past usage can be used to create load model and ensure that effects on customer comfort are minimized while still accomplishing the beneficial effects for the overall grid, which enables grid owners to both reduce their operational cost by avoiding expensive generation and improve system reliability by achieving more predictable power demand.

Ren, Wei

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N

Optimizing Insulation Design for Transformers in Medium Voltage Power Conversion Systems

Medium-frequency transformers (MFTs) play a crucial role in medium-voltage (MV) solidstate transformer (SST) systems, particularly in extreme fast charging applications. Achieving partial discharge (PD)-free operation while maintaining high power density is a significant challenge due to the high electric field (E-field) stresses inherent in MV applications. This dissertation focuses on the insulation design and optimization of MFTs used in both the main power electronics circuits and auxiliary power supplies. The study begins with an overview of insulation testing methodologies, including high potential tests, basic insulation level tests, and PD tests, which are critical for evaluating MFT insulation reliability. Given the importance of PD-free operation for long-term reliability, particular emphasis is placed on understanding PD mechanisms, including void, corona, and surface discharge, and their mitigation strategies. A high voltage isolated auxiliary power supply is then introduced, utilizing a gapped transformer encapsulated in silicone gel. This design achieves PD-free insulation up to 18 kV RMS while maintaining low coupling capacitance to minimize common-mode current. The proposed solution ensures reliable operation in MV environments and offers a scalable approach for auxiliary power in cascaded SST architectures. To improve MFT insulation in main power conversion circuits, a novel structure is developed using polypropylene sheets and potting compounds to create a void-free air gap, effectively mitigating E-field intensity. A prototype transformer with this insulation structure is built and achieves PD-free operation up to 30 kV RMS. This design is experimentally validated in a resonant converter operating at 46 kW, demonstrating its feasibility for MV SST applications. Further optimization is implemented to enhance MFT performance for dual-active-bridge(DAB) converters by integrating a semiconductive shielding layer within the insulation structure. This shielding layer improves the magnetic coupling coefficient while effectively confining the E-field within high insulation materials, thereby reducing eddy current losses. The optimized MFT achieves PD-free operation at 12.6 kV RMS and is successfully tested in a DAB converter operating at 43 kW, which meets the insulation requirements for a 13.2 kV SST system. This dissertation advances MFT insulation design by introducing and experimentally validating novel approaches that improve high voltage insulation while optimizing magnetic coupling and manufacturability. The proposed insulation structures enable PD-free operation while minimizing insulation material usage and simplifying assembly, making them ideal for high power, high voltage applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Novel Low-Profile High-Efficiency Three-Phase Matrix Transformer

High step-down isolated DC-DC conversion from an 800 V DC bus to low-voltage, high-current outputs is required in automotive auxiliary converters and data center power supplies. In such applications, conventional transformer-based converters require large turns ratios, which increase winding resistance, leakage inductance, and magnetic height. This paper proposes a novel low-profile three-phase matrix transformer that realizes a large effective voltage ratio through flux division among multiple secondary legs, without increasing the physical turns count of each winding. As a result, the proposed structure reduces copper usage and transformer height while preserving the voltage conversion capability of a conventional three-phase transformer. Finite element analysis shows that the proposed design reduces magnetic height by 27%, ferrite volume by 34%, and copper volume by 28%. Circuit-level simulations of an 800 V/12 V,3 kW CLLLC dual-active-bridge converter further show that the lower winding resistance reduces total system loss by 91% and increases DC-DC efficiency from 82.6% to 97.6% at 3 kW output.

Inoue, Shuntaro [ORNL] (ORCID:0000000262637627)

Analyzing Risks of Virtual Private Network Connections

The use of Splunk for analyzing VPN logs is an effective approach for identifying vulnerabilities in network endpoints. Splunk, a powerful platform for searching, monitoring, and analyzing machine-generated data, enables organizations to aggregate VPN logs in real-time, providing insights into network activity, user behavior, and potential security risks. By indexing VPN traffic and authentication logs, security teams can track abnormal patterns such as multiple failed login attempts, unusual IP addresses, or unexpected changes in bandwidth usage, all of which could indicate potential vulnerabilities or breaches. With Splunk’s advanced search and reporting capabilities, users can create custom dashboards and alerts to detect suspicious activities. Automated searches can flag endpoints exhibiting unusual behavior, while correlation analysis can identify links between compromised devices and broader network vulnerabilities. In particular, Splunk's machine learning capabilities can be leveraged to predict and prevent threats by identifying trends that might otherwise be missed in traditional log analysis. This proactive approach to monitoring VPN logs allows for the early detection of security weaknesses, enabling rapid response and minimizing potential damage to network integrity. By enhancing endpoint visibility, Splunk plays a crucial role in securing remote connections and safeguarding sensitive information. Additionally, Splunk’s automation and alerting features allow teams to create custom workflows that notify them of vulnerable or misconfigured endpoints identified through Shodan. This synergy between Splunk’s log analysis and Shodan’s device intelligence enhances an organization’s ability to proactively identify and mitigate security risks, improving the overall resilience of their VPN infrastructure.

97 MATHEMATICS AND COMPUTING

Operational Simulation of Multi-Functional Charging Station for Sustainable Transportation

As transportation systems move toward electrification and decarbonization, multifunctional charging stations (MFCS) are emerging as key infrastructure for electric vehicles (EVs) and hydrogen fuel cell vehicles (HFCVs). This paper presents a simulation model of an MFCS that integrates solar photovoltaic (PV), wind power, battery storage, hydrogen (\mathrm{H}_{2}) production, dual-pressure \mathrm{H}_{2} storage, fuel cells, and dynamic grid interactions. The model simulates daily operations using 5 -minute resolution data to capture realtime variability in renewable energy (RE), demand, and electricity prices. A flexible dispatch algorithm dynamically allocates energy for EV charging, \mathrm{H}_{2} production, storage, and grid transactions while respecting system constraints. Results show that the MFCS effectively prioritizes RE usage, minimizes waste, meets diverse energy demands, and achieves net operational profit. The model serves as a valuable decision-support tool for designing and optimizing integrated clean energy hubs for zero-emission transportation.

Gbadegoye, Jeremiah [University of Tennessee, Knox

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE

Object Proxy Patterns for Accelerating Distributed Applications

Workflow and serverless frameworks have empowered new approaches to distributed application design by abstracting compute resources. However, their typically limited or one-size-fits-all support for advanced data flow patterns leaves optimization to the application programmer—optimization that becomes more difficult as data become larger. The transparent object proxy, which provides wide-area references that can resolve to data regardless of location, has been demonstrated as an effective low-level building block in such situations. Here we propose three high-level proxy-based programming patterns—distributed futures, streaming, and ownership—that make the power of the proxy pattern usable for more complex and dynamic distributed program structures. We motivate these patterns via careful review of application requirements and describe implementations of each pattern. As a result, we evaluate our implementations through a suite of benchmarks and by applying them in three meaningful scientific applications, in which we demonstrate substantial improvements in runtime, throughput, and memory usage.

Distributed Computing