Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Precision tunable resonant microwave cavity

A tunable microwave cavity containing ionizable metallic vapor or gases and an apparatus for precisely positioning a microwave coupling tip in the cavity and for precisely adjusting at least one dimension of the cavity are disclosed. With this combined structure, resonance may be achieved with various types of ionizable gases. A coaxial probe extends into a microwave cavity through a tube. One end of the tube is retained in a spherical joint attached in the cavity wall. This allows the coaxial probe to be pivotally rotated. The coaxial probe is slideable within the tube thus allowing the probe to be extended toward or retracted from the center of the cavity.

Nakanishi, Shigeo↗

Microwave Cavity Simulation Using Ansys HFSS

The design of microwave cavity detectors for axion dark matter research is often accomplished using advanced full-wave electromagnetic simulation software tools. These tools provide a cost-effective approach to evaluate a wide variety of cavity configurations, frequency tuning mechanisms, and conductive or dielectric materials and coatings. One simulation software package used for this application is Ansys High Frequency Structure Simulator (HFSS), which is based upon the well-established finite element method. HFSS includes numerous features useful for microwave cavity design such as parametric geometry modeling, adaptive meshing algorithm, curvilinear mesh elements, driven modal and eigenmode matrix solvers, and optimization algorithms. This paper describes the use of the HFSS software to simulate microwave cavities for axion haloscope detectors, with an example tutorial for a cylindrical cavity. Excellent agreement between the simulated and analytical results is shown for the resonant frequency, quality factor, and form factor.

Ansys HFSS, Cavity simulation, finite element mode↗

Measuring Q And f(sub r) Of A Microwave Cavity: Part I

Method of measuring quality factor (Q) and frequency of resonance (f(subr)) of microwave cavity exploits two inflection points of power-vs.-frequency resonance curve of cavity. Intended particularly for use with microwave cavity in which sample of lossy dielectric material heated to specified high temperature by microwave power at resonant frequency. Accurate measurement contributes to enhanced monitoring and control in contactless high-temperature processing of materials. Also used with small spherical sample to determine temperature dependence of complex dielectric constant.

Barmatz, Martin B.↗

Superconducting microwave cavities and qubits for quantum information systems

Superconducting microwave cavities featuring ultrahigh Q-factors, which measure the efficiency of energy storage in relation to energy loss in a system, are revolutionizing quantum computing by providing long coherence times exceeding 1 ms, crucial for the development of scalable multi-qubit quantum systems with low error rates. Here, in this work, we provide an in-depth analysis of recent advances in ultrahigh Q-factor cavities, integration of Josephson junction-based qubits, and bosonic-encoded qubits in 3D cavities. We examine the sources of quantum state dephasing caused by damping and noise mechanisms in cavities and qubits, highlighting the critical challenges that need to be addressed to achieve even higher coherence times. We critically survey the latest progress made in implementing single 3D qubits using superconducting materials, normal metals, and multi-qubit and multi-state quantum systems. Our work sheds light on the promising future of this research area, including novel materials for cavities and qubits, modes with nontrivial topological properties, error correction techniques for bosonic qubits, and new light–matter interaction effects.

3D printing↗

Compact microwave cavity for hydrogen atomic clock

A summary is presented that introduces the compact microwave cavity used in the hydrogen atomic clock. Special emphasis is placed on derivation of theoretical calculating equations of main parameters of the microwave cavity. A brief description is given of several methods for discriminating the oscillating modes. Experimental data and respective calculated values are also presented.

Dejun Zhang↗

Tunable Microwave Cavity For Ion Source

Movable probe and tuning wall adjusted to obtain resonance at microwave frequency used to generate plasma in cell at one end of microwave cavity. Electroless discharge without disadvantages of dc-cathode-discharge and RF-induction methods. To achieve precise positioning, coaxial probe extends into microwave cavity through tube.

Nakanishi, Shigeo↗

Seamless High-Q Microwave Cavities for Multimode Circuit Quantum Electrodynamics

Multimode cavity quantum electrodynamics ---where a two-level system interacts simultaneously with many cavity modes---provides a versatile framework for quantum information processing and quantum optics. Due to the combination of long coherence times and large interaction strengths, one of the leading experimental platforms for cavity QED involves coupling a superconducting circuit to a 3D microwave cavity. In this work, we realize a 3D multimode circuit QED system with single photon lifetimes of $2$ ms and cooperativities of $0.5-1.5\times10^9$ across 9 modes of a novel seamless cavity. We demonstrate a variety of protocols for universal single-mode quantum control applicable across all cavity modes, using only a single drive line. We achieve this by developing a straightforward flute method for creating monolithic superconducting microwave cavities that reduces loss while simultaneously allowing control of the mode spectrum and mode-qubit interaction. We highlight the flexibility and ease of implementation of this technique by using it to fabricate a variety of 3D cavity geometries, providing a template for engineering multimode quantum systems with exceptionally low dissipation. This work is an important step towards realizing hardware efficient random access quantum memories and processors, and for exploring quantum many-body physics with photons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Revealing the loss mechanisms of a 3D superconducting microwave cavity for use in a dark matter search

Superconducting microwave cavities have found applications in many areas including quantum computing, particle accelerators, and dark matter searches. Their extremely high quality factors translate to very narrow bandwidth, which makes them key components of sensitive detectors. In this study, we aim to understand the loss mechanisms of an aluminium cavity, with a fundamental mode frequency of about 2.5123 GHz, and how they change as the cavity material transitions from the superconducting to normal state. We found that at temperatures not much lower than the transition temperature $T_c$, losses are dominated by quasiparticle excitations and are well described by the Bardeen–Cooper–Schrieffer theory. The exponential decrease of the quasiparticle density below $T_c$ results in a 1000-fold increase of the quality factor, as well as a shift of the resonance frequency due to the change of the kinetic inductance of the superconductor. At very low temperatures, losses due to two-level systems begin to dominate giving a peak in the quality factor of about 2.76 x 10 7 at 130 mK. Understanding the loss mechanisms is invaluable, as the working temperature of the cavity may vary during operation regardless of its application.

Physics - Physics of elementary particles and fiel↗

Measuring Q And f(sub r) Of A Microwave Cavity: Part II

Frequency maintained at f(sub r), and Q determined from decay-rate measurement. Like "Measuring Q and f(sub r) of a Microwave Cavity: Part I" (NPO-19101), method used with microwave cavity in which sample of lossy dielectric material heated to specified high temperature by microwave power at resonant frequency. Methods contribute to accurate measurement of Q and f(sub r) for enhanced monitoring and control in contactless high-temperature processing of materials. Present method more effective in maintaining constant temperature. Also implemented more simply and at lower cost.

Iny, Ofer↗

Mechanical Actuation Mechanism Design for Cryogenic Microwave Cavities in Axion Dark Matter Searches

Resonant Microwave Cavities are placed in a strong magnetic field at cryogenic temperatures (~.1K) in order to try to convert axions into detectable photons. A major challenge is to tune the cavity to allow no interference with the desired environment used for the experiment, which enables the system to operate near absolute zero and maintain superconductivity, thereby reducing noise as much as possible. My project focuses on developing and testing a low-thermal-conductivity gear reduction system with a 1000:1 ratio for cavity tuning. This gear system could significantly improve the thermal and electromagnetic interference of the tuning mechanism, helping ADMX scan for axions more accurately.

Ortega, Giancarlo [Marquette U.; Fermilab]↗