Machine learning for improved current-density reconstruction from two-dimensional vector magnetic images

The reconstruction of electrical current densities from magnetic field measurements is an important technique with applications in materials science, circuit design, quality control, plasma physics, and biology. Analytic reconstruction methods exist for planar currents, but break down in the presence of high-spatial-frequency noise or large standoff distance, restricting the types of systems that can be studied. Here, we demonstrate the use of a deep convolutional neural network for current density reconstruction from two-dimensional images of vector magnetic fields acquired by a quantum diamond microscope . Trained network performance significantly exceeds analytic reconstruction for data with high noise or large standoff distances. This machine learning technique can perform quality inversions on lower-signal-to-noise-ratio data, significantly reducing the data collection time and permitting reconstructions of weaker and three-dimensional current sources. Published by the American Physical Society 2025

Reed, Niko R. (ORCID:0009000305222403)

Magnetic flux imaging in a 3D superconductor integrated circuit

We report on imaging magnetic flux distributions in a multilayered superconductor integrated circuit which emerge during magnetization and after field cooling of the circuit in the DC magnetic field. The obtained complicated field maps expose the flux propagation across the patterned superconducting ground planes sandwiching layers with Josephson junction-based logic cells, fine wire grid around the functional units, and multiple superconducting fill structures located in different inner layers. The observed intricate flux distributions are explained by specific patterns of Meissner screening currents and superconducting critical currents in different mutually interacting parts of the integrated circuit. Our results provide important insights into possible ways of improving the protection of superconductor integrated circuits from magnetic fields and their resilience against flux trapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects

Precipitation of gadolinium from magnetic resonance imaging contrast agents may be the Brass tacks of toxicity

The formation of gadolinium-rich nanoparticles in multiple tissues from intravenous magnetic resonance imaging contrast agents may be the initial step in rare earth metallosis. The mechanism of gadolinium-induced diseases is poorly understood, as is how these characteristic nanoparticles are formed. Gadolinium deposition has been observed with all magnetic resonance imaging contrast agent brands. Aside from endogenous metals and acidic conditions, little attention has been paid to the role of the biological milieu in the degradation of magnetic resonance imaging contrast agents into nanoparticles. Herein, we describe the decomposition of the commercial magnetic resonance imaging contrast agents Omniscan and Dotarem in the presence of oxalic acid, a well-known endogenous compound. Omniscan dechelated rapidly and preluded measurement by the means available, while Dotarem underwent a two-step decomposition process. The decomposition of both magnetic resonance imaging contrast agents by oxalic acid formed gadolinium oxalate (Gd 2 [C 2 O 4 ] 3 , Gd 2 Ox 3 ). Furthermore, both observed steps of the Dotarem reaction involved the associative addition of oxalic acid. Adding protein (bovine serum albumin) increased the rate of dechelation. Displacement reactions could occur at lysosomal pH. Through these studies, we have demonstrated that magnetic resonance imaging contrast agents can be dissociated by endogenous molecules, thus illustrating a metric by which gadolinium-based contrast agents (GBCAs) might be destabilized in vivo.

Gadodiamide

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE

High fidelity simulations of contaminant dispersion in an urban environment with comparison to magnetic resonance imaging measurements

The dispersion of a contaminant in an urban environment has the potential to impact a large population of people. In this work, a complex urban canopy flow based on the Oklahoma City downtown business district circa 2003 is studied using Magnetic Resonance Imaging (MRI) and high-fidelity Large Eddy Simulations (LES). MRI is a novel experimental technique that can provide high-resolution measurements in four dimensions (three spatial and temporal) for lab scale models. The experiments and simulations use the same geometry and boundary conditions providing a one-to-one comparison of the two methods. Results are presented on the time-averaged velocity and concentration fields, the temporal dynamics of the concentration plumes for a transient release, and a novel Cloud Identification Algorithm that can separate plumes produced by periodic contaminant releases used for ensemble averaging over many releases. The MRI and LES datasets both include millions of measurement voxels and the comparisons highlight the complex 3D nature of the flow including strong vertical velocities in spanwise street canyons and flow acceleration in streamwise street canyons. The concentration fields are qualitatively similar albeit the LES shows larger dispersion. A quantitative analysis with performance measures compares the datasets pointwise and demonstrates that the two 3D datasets are similar with respect to many measures including a fractional bias of 0.02 (ideal=0.0), correlation coefficient of 0.87 (ideal = 1.0), and the fraction points within a factor of 2 is 0.98 (ideal = 1.0). Plume analysis compares the arrival and residence time of contaminant and is found to vary significantly with location within the urban environment with arrival times between 0 and 1.25 and differences within the contaminant cloud less than 10% at most locations.

54 ENVIRONMENTAL SCIENCES

Multimode turbulent flow measurements using magnetic resonance imaging- and laser-based techniques and computational fluid dynamics simulations

We studied the flow field characteristics of a turbulent flow over a regularized cube array with a perpendicular injection flow through the floor between the second and third cubical elements, representing the complex flow interactions of a 3D jet and the wake flows behind cubical obstacles. Four different experimental measurements were performed: two magnetic resonance imaging-based measurements for three-dimensional three-component velocity (MRV) and concentration (MRC) and two laser-based techniques, particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF), for two-dimensional two-component velocity and concentration measurement, respectively. The mainstream Reynolds number is Re = 15 000⁠, based on the primary inlet velocity U m and channel height D H ⁠, whereas the injector Reynolds number is Re j = 3400⁠, based on the injector velocity U j and the injector's exit width D j ⁠. Numerical simulations were performed for the studied flow configuration of turbulent flow over a regularized cube array using Reynolds-averaged Navier–Stokes (RANS) and large-eddy simulation (LES) approaches. Results obtained from experimental measurements—including MRV, MRC, PIV, and PLIF—as well as RANS and LES simulations are discussed and compared along several horizontal and vertical planes of the studied configuration. In addition, 3D turbulent flow structures, such as leading-edge vortex, horseshoe vortex, and jet shear-layer vortex, and the isosurfaces of scalar concentration successfully revealed by MRV and MRC techniques were found to be in very good agreement with those 3D features extracted from RANS and LES simulations. In conclusion, the high-resolution experimental and numerical database obtained from this study could be useful for validation and verification of numerical codes.

Computational fluid dynamics

Development of neutron spin-phase imaging for amorphous magnetic thin film investigation

Neutron spin-phase imaging (NSPI) capability was developed to study the magnetization distribution of an amorphous magnetic thin film. The local magnetization under different applied magnetic fields between 0.09 and 1.36 mT was investigated. The developed radio frequency flippers showed more than 95% flipping efficiency under these fields. A spatial resolution of ~0.4 mm and field of view of ~24 mm x 27 mm were achieved. In conclusion, the bulk property of the random distributions of the magnetization and magnetic field distribution ranging between ~1.1 and 1.4 T were observed showing that NSPI is a useful technique for investigating the spatial dependence of magnetic properties of amorphous magnetic thin films.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Direct measurement of reduced exchange stiffness and its impact on magnetic vortex behavior in PyGd alloys

Thin films composed of sputtered transition metal/rare earth (TM/RE) ferrimagnets have emerged as promising building blocks for future spintronic devices, offering tunable magnetic properties critical for data storage, memory, and logic applications. However, understanding how the combination of TM and RE elements influences effective magnetic properties, such as exchange stiffness (Aex), remains challenging. Magnetic vortices provide a versatile tool for probing these properties in thin film systems. By combining magnetic imaging via soft x-ray microscopy and micromagnetic modeling, we quantify the effective exchange stiffness in PyGd ferrimagnetic disks with varying Gd concentrations. Our results indicate a reduction in Aex to below 3 pJ/m for a 20% Gd concentration when compared to reference Py, and values below 2 pJ/m for 30% Gd, reflecting weak Ni–Gd exchange coupling. These findings highlight the critical role of rare earth content in tuning the exchange stiffness. The reduced exchange stiffness facilitates a linear field response of the magnetization up to the edge of the disk, as well as significant deformations in the vortex core itself when compared to films with larger Aex. Our results are in line with, albeit lower than, recent measurements of the exchange stiffness in intermixed PyGd. This reduced exchange stiffness has implications for the development of spintronic devices based on ferrimagnetic skyrmions.

Jacob, Liyan

Space-Charge-Limited van der Waals Spin Transistor

Integrating semiconducting and magnetic materials could combine transistorlike operation with nonvolatility and enable architectures such as logic in memory. Here, in this work, we employ correlated electrical transport and scanning nitrogen-vacancy center magnetic imaging to elucidate a spin transistor concept that amalgamates vertical and lateral hopping transport inside a 2D antiferromagnetic semiconductor, mechanistically distinct from vertical tunneling devices. Our device, based on a monolayer-bilayer junction in CrSBr, displays giant, gate-tunable magnetoresistance driven by the dual action of electrostatic doping on space-charge-limited lateral conduction and interlayer exchange coupling. Moreover, we visualize a field-trainable, layer-sharing effect that selects between coherent or domain-wall reversal at the spin-flip transition, enabling multilevel, memristive conductance states. Our layer-dependent space charge mechanism for convergent electrical and magnetic control opens opportunities to address limitations in contemporary computing.

2-dimensional systems

Cognitive aging outcomes are related to both tau pathology and maintenance of cingulate cortex structure

Abstract INTRODUCTION Successful cognitive aging is related to both maintaining brain structure and avoiding Alzheimer's disease (AD) pathology, but how these factors interplay is unclear. METHODS A total of 109 cognitively normal older adults (70+ years old) underwent amyloid beta (Aβ) and tau positron emission tomography (PET) imaging, structural magnetic resonance imaging (MRI), and cognitive testing. Cognitive aging was quantified using the cognitive age gap (CAG), subtracting chronological age from predicted cognitive age. RESULTS Lower CAG (younger cognitive age) was related to slower decline in episodic memory, multi‐domain cognition, and atrophy of the midcingulate cortex (MCC). Lower entorhinal cortical tau was linked to slower decline in episodic memory, multi‐domain cognition, and hippocampal atrophy. DISCUSSION These results suggest that aging outcomes may be influenced by two independent pathways: one associated with tau accumulation, affecting primarily memory and hippocampal atrophy, and another involving tau‐independent structural preservation of the MCC, benefiting multi‐domain cognition over time. Highlights Younger cognitive age (lower cognitive age gap [CAG]) is related to slower cognitive decline. Lower CAG is linked to slower midcingulate cortex (MCC) atrophy. Reduced tau in the entorhinal cortex is related to less hippocampal atrophy and cognitive decline. Structural preservation of the MCC benefits multi‐domain cognition over time. Two independent pathways influence cognitive aging: tau accumulation and MCC preservation.

Neurosciences & Neurology

Creation of depth-confined, shallow nitrogen-vacancy centers in diamond with tunable density

Engineering shallow nitrogen-vacancy (NV) centers in diamond holds the key to unlocking new advances in nanoscale quantum sensing. We find that the creation of near-surface NVs through delta doping during diamond growth allows for tunable control over both NV depth confinement (with a twofold improvement relative to low-energy ion implantation) and NV density, ultimately resulting in highly sensitive single defects and ensembles with coherence limited by NV–NV interactions. Additionally, we demonstrate the utility of our shallow delta-doped NVs by imaging magnetism in few-layer CrSBr, a two-dimensional magnet. Here, we anticipate that the control afforded by near-surface delta doping will enable new developments in NV quantum sensing from nanoscale nuclear magnetic resonance to entanglement-enhanced metrology.

Chemical vapor deposition

Magnetic force microscopy revealing long-range room temperature stable molecule bridge-induced magnetic ordering on magnetic tunnel junction (MTJ) pillars

Magnetic tunnel junctions (MTJs) can integrate novel single molecular device elements to overcome long-standing fabrication challenges, thus unlocking their novel potential. This study employs magnetic force microscopy (MFM) to demonstrate that organometallic molecules, when placed between two ferromagnetic electrodes along cross-junction shaped MTJ edges, dramatically altered the magnetic properties of the electrodes, affecting areas several hundred microns in size around the molecular junction vicinity at room temperature. These findings are supported by magnetic resonance and magnetometer studies on ∼7000 MTJ pillars. MFM on the pillar sample showed an almost complete disappearance of the magnetic contrast. The spatial magnetic image suggests that molecular channels significantly impacted the spin density of states in the ferromagnetic electrodes. This advancement in MTJ-based molecular devices paves the way for a new generation of commercially viable logic and memory devices controlled by molecular quantum states at near-room temperatures.

Tyagi, Pawan (ORCID:0000000275411344)

Effect of metal encapsulation on bulk superconducting properties of niobium thin films used in qubits

Niobium metal occupies nearly 100% of the volume of a typical 2D transmon device. While the aluminum Josephson junction is of utmost importance, maintaining quantum coherence across the entire device means that pair-breaking in Nb leads, capacitive pads, and readout resonators can be a major source of decoherence. The established contributors are surface oxides and hydroxides, as well as absorbed hydrogen and oxygen. Metal encapsulation of freshly grown surfaces with non-oxidizing metals, preferably without breaking the vacuum, is a successful strategy to mitigate these issues. While the positive effects of encapsulation are undeniable, it is important to understand its impact on the macroscopic behavior of niobium films. We present a comprehensive study of the bulk superconducting properties of Nb thin films encapsulated with gold and palladium/gold, and compare them to those of bare Nb films. Magneto-optical imaging, magnetization, resistivity, and London and Campbell penetration depth measurements reveal significant differences in encapsulated samples. Both sputtered, and epitaxial Au-capped films exhibit the highest residual resistivity ratio and superconducting transition temperature, as well as the lowest upper critical field, London penetration depth, and critical current. These results are in good agreement with the microscopic theory of anisotropic normal and superconducting states of Nb. We conclude that pair-breaking in the bulk of niobium films, driven by disorder throughout the film rather than just at the surface, is a significant source of quantum decoherence in transmons. We also conclude that gold capping not only passivates the surface but also affects the properties of the entire film, significantly reducing the scattering rate due to defects likely induced by surface diffusion if the film is not protected immediately after fabrication.

Datta, Amlan [Ames Lab; Iowa State U.]

Deep generative learning of magnetic frustration in artificial spin ice from magnetic force microscopy images

Increasingly large datasets of microscopic images with nanoscale resolution facilitate the development of machine learning methods to identify and analyze subtle physical phenomena embedded within the images. In this work, microscopic images of honeycomb lattice spin-ice samples serve as datasets from which we automate the calculation of net magnetic moments and directional orientations of spin-ice configurations. In the first stage of our workflow, machine learning models are trained to accurately predict magnetic moments and directions within spin-ice structures. Variational Autoencoders (VAEs), an emergent unsupervised deep learning technique, are employed to generate high-quality synthetic magnetic force microscopy (MFM) images and extract latent feature representations, thereby reducing experimental and segmentation errors. The second stage of proposed methodology enables precise identification and prediction of frustrated vertices and nanomagnetic segments, effectively correlating structural and functional aspects of microscopic images. This facilitates the design of optimized spin-ice configurations with controlled frustration patterns, enabling potential on-demand synthesis.

36 MATERIALS SCIENCE