Engineering PapersSearch

DOE OSTI · 2483589

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

Abstract

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hernandez, Andrew M. [Univ. of California Davis Medical Center, Sacramento, CA (United States)] (ORCID:0000000218067073), Chen, Anthony F. [Univ. of California Davis Medical Center, Sacramento, CA (United States)], Ghatpande, Omkar [National Renewable Energy Laboratory (NREL), Golden, CO (United States)] (ORCID:0000000284242490), Omary, Reed A. [Vanderbilt Univ., Nashville, TN (United States)], Woolen, Sean [Univ. of California, San Francisco, CA (United States)], Jung, Youngkyoo [Univ. of California Davis Medical Center, Sacramento, CA (United States)], Fananapazir, Ghaneh [Univ. of California Davis Medical Center, Sacramento, CA (United States)]. 2025-03-01. Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations. https://doi.org/10.1097/rct.0000000000001700

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE