Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEDICAL EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Medical Imaging Equipment Energy Efficiency

The energy use of medical imaging equipment (MIE) in healthcare facilities is estimated to be about 5% of total site energy use. MIE energy use is only expected to increase as technology advances and more patients seek services from MIE, enabling more facilities to install additional MIE. Healthcare organizations need reliable information regarding comprehensive energy use or lifetime energy costs with which to make energy-efficient MIE procurement decisions, and there are currently no MIE energy or efficiency standards in the United States (U.S.). This fact sheet provides background on MIE energy consumption, key terms, and guidance on why and how to meter MIE, helping stakeholders make informed decisions to enhance their facility's performance.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Survey of Thirteen Novel Pseudomonas putida Bacteriophages

Bacteriophages have been widely investigated as a promising treatment of food, medical equipment, and humans colonized by antibiotic-resistant bacteria. Phages pose particular interest in combating those bacteria which form biofilms, such as the medically important human pathogen Pseudomonas aeruginosa and several plant pathogens, including P. syringae . In an undergraduate lab course, P. putida was used as the host to isolate novel anti-pseudomonal bacteriophages. Environmental samples of soil and water were collected, and purified phage isolates were obtained. After Illumina sequencing, genomes of these phages were assembled de novo and annotated. Assembled genomes were compared with known genomes in the literature and GenBank to identify taxonomic relations and to refine their functional annotations. The thirteen phages described are sipho-, myo-, and podoviruses in several families of Caudoviricetes , spanning several novel genera, with genomes ranging from 40,000 to 96,000 bp. One phage (DDSR119) is unique and is the first reported P. putida siphovirus. The remaining 12 can be clustered into four distinct groups. Six are highly related to each other and to previously described Autotranscriptaviridae phages: Waldo5, PlaquesPlease, and Laces98 all belong to the Waldovirus genus, whereas Stalingrad, Bosely, and Stamos belong to the Troedvirus genus. Zuri was previously classified as the founding member of a new genus Zurivirus within the family Schitoviridae . Ebordelon and Holyagarpour each represent different species within Zurivirus , whereas Meara is a more distantly related member of the Schitoviridae . Dolphis and Jeremy are similar enough to form a genus but have only a few distant relatives among sequenced phages and are notable for being temperate. We identified the lysis cassettes in all 13 phages, compared tail spike structures, and found auxiliary metabolic genes in several. Studies like these, which isolate and characterize infectious virions, enable the identification of novel proteins and molecular systems and also provide the raw materials for further study, evaluation, and manipulation of phage proteins and their hosts.

Pseudomonas putida↗

Lightweight, Flexible Electromagnetic Shielding Composite Films Reinforced with Recycled Carbon Fibers and Carbon Nanofillers

Lightweight, flexible polymer composites are widely adopted in modern electronic devices and systems for high-efficiency electromagnetic interference (EMI) shielding. Reinforcing polymer composites with conductive fillers offers a promising alternative to conventional metal-based shielding material thanks to their low density, tunable properties, and flexibility. Herein, lightweight, flexible ultra-high molecular weight polyethylene composite films reinforced with recycled carbon fibers (rCFs) and carbon-based nanofillers, including graphene nanoplatelets (GNPs) and carbon nanotubes, are reported for EMI shielding applications. The incorporation of these nanofillers significantly reduces the required content of rCFs and improves processability while maintaining comparable shielding effectiveness. The addition of these nanofillers with rCFs enhances the EMI shielding effectiveness by up to 15 dB. Incorporating 1 wt% GNPs can replace 5 wt% rCFs and achieve comparable EMI shielding performance, while 5 wt% of either nanofillers can substitute for 10 wt% rCFs. Numerical modeling of electromagnetic wave transmission reveals that increasing nanofiller concentrations enhances both reflection and absorption losses, with absorption consistently dominating across all levels. Furthermore, this study not only provides insight into the synergistic contributions of rCFs and carbon nanofillers to shielding effectiveness but also paves the way for the design of sustainable, lightweight EMI shielding composite films for applications in electric vehicles, medical equipment, and portable electronics.

carbon nanofiller↗

Overview on Current Activities of Conduction-Cooled SRF Accelerators and their Applications

When Nb3Sn was reintroduced to the SRF community as an alternative to pure niobium, one key motivation has been to reduce the cryogenic requirements of new and existing accelerators by shifting from 2 K to 4 K operation. Meanwhile, a variety of implementations beyond research machines are being explored. The combination of Nb3Sn with conventional cryocoolers, enabling cryogen-free operation, has paved the way for the development of compact, standalone systems suitable for applications far beyond research, such as enhancing the durability of synthetics via crosslinking or sterilizing food and medical equipment, as well as environmental cleanup when it comes to decontaminating liquid and solid waste material. So, while fundamental R&D continues to refine Nb3Sn resonators, exploring improvements such as replacing the niobium substrate with copper, parallel research efforts are investigating how the increased beam power provided by SRF could expand the commercial use of electron beams. This presentation aims to deliver a comprehensive overview of ongoing research efforts to harness the benefits of SRF through Nb3Sn and conduction cooling.

Vennekate, John [Thomas Jefferson National Acceler↗

Machine learning based reconstruction of intracardiac electrical behavior based on electrocardiograms

A computer-based system and process are disclosed for reconstructing the internal electrical behavior of a patient's heart based partly or wholly on the patient's electrocardiogram (ECG). The output of the process may include, for example, a cardiac activation map, and/or a representation of transmembrane potentials over time. The process advantageously does not require any medical imaging of the patient, and does not require any special medical equipment. For example, the patient's activation map and transmembrane potentials may be reconstructed based solely on a preexisting or newly-obtained 12-lead cardiac ECG of the patient. The process makes use of a machine learning model, such as a neural network based model, trained with actual and/or simulated ECGs and intracardiac electrical data (typically transmembrane potentials) of many thousands of patients. Because an insufficient quantity of such data exists for actual patients, model training may be performed using ECGs and intracardiac electrical data obtained through computer simulations.

Blake, Robert↗

MRI Load Profile Characterization Across Scanner Manufacturers and Field Strengths - Opportunities for Energy Efficiency Improvements

Radiology plays a vital role in patient care, but a reliance on energy-intensive imaging equipment leads to significant greenhouse gas emissions. MRI scanners can consume up to 80% of their total energy during times when there is not active patient imaging. Characterizing MRI average power and time to enter low-power mode across scanning protocols can identify energy efficiency opportunities.

emissions↗

Mechanistic Insights into the Surface Instabilities of TiNb 2 O 7, a High‐Power Li‐Ion Anode

TiNb 2 O 7 (TNO) is a promising Li-ion battery anode for high-power applications, such as implantable medical devices and heavy-duty equipment. Hailed as being safe due to its elevated operating potential near 1.6 V, TNO has long been assumed to be highly stable in the carbonate-based electrolytes used in Li-ion batteries. Herein, all mechanisms occurring at the surface of both TNO and Nd-doped TNO are identified, and both materials in fact show significant gassing. CO 2 is even released at open circuit conditions, demonstrating the poor chemical stability of the material in the electrolyte even prior to battery operation. Such extreme instability is a critical safety concern. In addition, it was found that Ti dissolves from the surface of TNO particles at low voltage (below 1.4 V vs Li), and in fact deposits on the counter electrode. Ti further inside TNO particles then diffuses to the Ti-poor surface during discharge. Partial carbon-coating as a mitigating measure has also been tested and found to exacerbate these processes. The findings identify novel reactions occurring within TNO, and clearly highlight the need to stabilize the surfaces of TNO in order to prevent such aggressive deterioration at the surface of the particles.

25 ENERGY STORAGE↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the reliability of medical resource demand models in the context of COVID-19

Abstract Background Numerous medical resource demand models have been created as tools for governments or hospitals, aiming to predict the need for crucial resources like ventilators, hospital beds, personal protective equipment (PPE), and diagnostic kits during crises such as the COVID-19 pandemic. However, the reliability of these demand models remains uncertain. Methods Demand models typically consist of two main components: hospital use epidemiological models that predict hospitalizations or daily admissions, and a demand calculator that translates the outputs of the epidemiological model into predictions for resource usage. We conducted separate analyses to evaluate each of these components. In the first analysis, we validated various hospital use epidemiological models using a recent validation framework designed for epidemiological models. This allowed us to quantify the accuracy of the models in predicting critical aspects such as the date and magnitude of local COVID-19 peaks, among other factors. In the second analysis, we evaluated a range of demand calculators for ventilators, medical gowns, and COVID-19 test kits. To achieve this, we decoupled these demand calculators from the underlying epidemiological models and provided ground truth data for their inputs. This approach enabled a direct comparison of the demand calculators, comparing them against each other and actual usage data when available. The code is available athttps://doi.org/10.5281/zenodo.13712387. Results Performance varied greatly across the epidemiological models, with greater variability in COVID-19 hospital use predictions than for COVID-19 deaths as analyzed previously. Some models did not have any peaks. Among those that did, the models under-estimated date of peak approximately as often as they over-estimated, but were more likely to under-estimate magnitude of peak, with typical relative errors around 50%. Regarding demand calculator predictions, there was significant variability, including five-fold differences in predictions for gown models. Validation against actual or surrogate usage data illustrated the potential value of demand models while demonstrating their limitations. Conclusions The emerging field of demand modeling holds promise in averting medical resource shortages during future public health emergencies. However, achieving this potential necessitates focused efforts on standardization, transparency, and rigorous model validation before placing reliance on demand models in critical public health decision-making.

Medical Informatics↗

Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize core from two wells that represent coal resources across North Dakota. These include the MC23080C Well in Mercer County and the 23-B001 Well in Oliver County. The primary impetus of this work was to capture a detailed digital representation of the core from the MC23080C and 23-B001 Wells. The collaboration between the NETL and the Energy and Environment Research Center (EERC) enables other research entities to access information about this potential carbon ore, rare earth, and critical mineral resource plays in the Williston Basin. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core, with the resulting macro- and micro-descriptions relevant to many subsurface energy-related examinations traditionally performed at NETL.

01 COAL, LIGNITE, AND PEAT↗

Computed Tomography Scanning and Geophysical Measurements of UW Enterprises LP 1-250512-129 Well in Southwestern Indiana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Illinois Basin core of the Upper Devonian-Early Mississippian New Albany Shale Formation from Posey County, Indiana. The primary impetus of this work is a collaboration between Indiana Geological and Water Survey at Indiana University Bloomington, NETL, and Woolsey Operating Company LLC to characterize and make publicly available core information from the New Albany Shale of the Illinois Basin. Core characterization of this unconventional oil/gas well will aid in understanding the lithology changes and the fracture complexity of the New Albany Shale. There is a potential for this formation to be developed in the future for critical mineral and rare earth element (CM/REE) extraction. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/uw-enterprises. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on this core. None of the equipment used was suitable for direct visualization of the pore space in the fine-grained structures studied; however, fractures, discontinuities, and millimeter-scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Targeted higher resolution CT scanning of select sections was performed with NETL’s industrial and micro-CT scanner. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

Study of eVTOL Charging Impact on Airport Electrical Grids

Growth in commercial air traffic has increased the aviation industry's contribution to global emissions. Aircraft electrification can reduce greenhouse gas emissions along with being efficient and reliable. Advanced air mobility introduces the idea of an advanced and more efficient air transportation system. Electric and hybrid aircraft designs, such as electric vertical takeoff and landing (eVTOL), are being considered for a number of applications, such as urban air mobility, cargo delivery, and medical emergencies. Although the electrification of aircraft provides environmental benefits, their charging needs will place significant demand on the electrical grid. This work presents a grid impact study and infrastructure upgrade requirements analysis of eVTOL charging on a realistic distribution grid through power flow simulation analysis. The case study results show that the eVTOL charging can lead to power quality issues, such as undervoltage and equipment capacity overloading. Grid infrastructure, such as lines and transformers, would need to be upgraded, and voltage management strategies would need to be deployed to accommodate eVTOL charging at an existing airport.

advanced air mobility (AAM)↗

Metasurface‐Based Mueller Matrix Microscope

In conventional optical microscopes, image contrast of objects mainly results from the differences in light intensity and/or color. Muller matrix optical microscopes (MMMs), on the other hand, can provide significantly enhanced image contrast and rich information about objects by analyzing their interactions with polarized light. However, state-of-the-art MMMs are fundamentally limited by bulky and slow polarization state generators and analyzers. Here, the study demonstrates a metasurface-based MMM, i.e., Meta-MMM, which is equipped with a chip-integrated, single-shot metasurface polarization state analyzer (Meta-PSA). The Meta-MMM is featured with high-speed measurement (≈2s per Muller matrix (MM) image), superior operation stability, dual-color operation, and high measurement accuracy (measurement error 1–2%) for MM imaging. The Meta-MMM is applied to nanostructure characterization, surface morphology analysis, and discovering birefringent structures in honeybee wings. As a result, the Meta-MMMs hold the promise to revolutionize various applications from biological imaging, medical diagnosis, and material characterization to industry inspection and space exploration.

36 MATERIALS SCIENCE↗

On the Necessity of Adopting Irradiation Protocols Recommended by the Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER) in Published Research and Why It Matters to Health Physicists

The National Nuclear Security Administration (NNSA) seeks to assist and support all partners in the fields of radiobiology, health physics, radiation physics, and related areas to transition from cesium-137 chloride-based technologies that can potentially be used in an act of terrorism to X-ray technologies. The absence of information on experimental procedures, equipment, and irradiation parameters directly and negatively impacts the reproducibility and translatability of a sizable portion of radiation biology studies. It also discourages researchers from adopting new tools that eliminate the risks of a radiological dispersal device.

Stern, Warren [Brookhaven National Laboratory (BNL↗

Twentieth Exotic Beam Summer School (EBSS2023)

The study of unstable nuclei with unusual ratios of protons to neutrons is one of the frontiers of science. Investigating these rare isotopes is critical for understanding the synthesis of the chemical elements in stellar explosions as well as the fundamental nature of the nuclear forces that bind atomic nuclei together. Scientific progress in this field is driven by the development of exotic beams in present and next-generation rare-isotope beam facilities including the Facility for Rare Isotope Beams (FRIB). Nuclear physics is a broad discipline, influencing our knowledge on subjects as diverse as weakly-bound nuclei, many-body quantum theory, the super heavy elements, and the inner structure of neutron stars. Applications based on nuclear science and technologies include medical diagnostics and therapies, materials science, and national security. The major goal achieved in this project was to hold Exotic Beam Summer School 2023 (EBSS2023), the twentieth installment of EBSS series, July 9-15, 2023 at the Facility for Rare Isotope Beams on the campus of Michigan State University to educate and train the next generation of scientists that will drive research with rare-isotope beams. FRIB became operational in 2022 and is now providing beams of exotic nuclei that will ramp up to unmatched intensities, exceeding what is available today by orders of magnitude. Beams available at FRIB are facilitating a wide variety of studies in nuclear structure, astrophysics, fundamental symmetries and societal applications. There is a large community of scientists interested in working with rare isotope beams; for example, the FRIB User Organization currently has over 1,700 members. In order to maximize the scientific output of FRIB, there must be a workforce continuously trained in both the physics of exotic beams and in the practical techniques of carrying out an experiment. This summer school series is designed to specifically address this need - to ensure that new generations of scientists from a broad range of institutions and backgrounds is trained, motivated, and equipped to push the field forward to new and important breakthroughs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

2024 Stor4Build Annual Meeting: Exploring Challenges and Opportunities in Thermal Energy Storage for Buildings

In late August 2024, Stor4Build brought nearly 80 stakeholders from the thermal energy storage industry to Oak Ridge National Laboratory (ORNL), including researchers, startups, electric utilities, nonprofits, implementers, state energy efficiency offices, and original equipment manufacturers. During the two-day Stor4Build Annual Meeting, participants engaged in vital discussions about the current challenges and opportunities for scaling thermal energy storage solutions in buildings. The event featured panel discussions led by leading technology experts and industry practitioners, as well as updates on Stor4Build–funded projects from national laboratories, highlighting advancements in the thermal energy storage field crucial to achieving the consortium’s mission.

25 ENERGY STORAGE↗