Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Level Controllers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Television camera video level control system

A video level control system is provided which generates a normalized video signal for a camera processing circuit. The video level control system includes a lens iris which provides a controlled light signal to a camera tube. The camera tube converts the light signal provided by the lens iris into electrical signals. A feedback circuit in response to the electrical signals generated by the camera tube, provides feedback signals to the lens iris and the camera tube. This assures that a normalized video signal is provided in a first illumination range. An automatic gain control loop, which is also responsive to the electrical signals generated by the camera tube 4, operates in tandem with the feedback circuit. This assures that the normalized video signal is maintained in a second illumination range.

Kravitz, M.

Task-level control for autonomous robots

Task-level control refers to the integration and coordination of planning, perception, and real-time control to achieve given high-level goals. Autonomous mobile robots need task-level control to effectively achieve complex tasks in uncertain, dynamic environments. This paper describes the Task Control Architecture (TCA), an implemented system that provides commonly needed constructs for task-level control. Facilities provided by TCA include distributed communication, task decomposition and sequencing, resource management, monitoring and exception handling. TCA supports a design methodology in which robot systems are developed incrementally, starting first with deliberative plans that work in nominal situations, and then layering them with reactive behaviors that monitor plan execution and handle exceptions. To further support this approach, design and analysis tools are under development to provide ways of graphically viewing the system and validating its behavior.

Simmons, Reid

Spike-Free Automatic Level Control

New automatic-level-control circuit protects against signal "overshoot." Zener diodes and series capacitors prevent voltage spikes (caused by sudden increase in input level) from appearing at output. When spike voltage drops below breakdown voltage of Zener diodes, they turn off. Initial output level is determined by Zener breakdown voltage and capacitance of series capacitor.

Toole, P. C.

Automatic level control circuit

An automatic level control circuit for an operational amplifier for minimizing spikes or instantaneous gain of the amplifier at a low period wherein no signal is received on the input is provided. The apparatus includes a multibranch circuit which is connected between an output terminal and a feedback terminal. A pair of zener diodes are connected back to back in series with a capacitor provided in one of the branches. A pair of voltage dividing resistors are connected in another of the branches and a second capacitor is provided in the remaining branch of controlling the high frequency oscillations of the operational amplifier.

Toole, P. C.

Automated Liquid-Level Control of a Nutrient Reservoir for a Hydroponic System

A microprocessor-based system for control of the liquid level of a nutrient reservoir for a plant hydroponic growing system has been developed. The system uses an ultrasonic transducer to sense the liquid level or height. A National Instruments' Multifunction Analog and Digital Input/Output PC Kit includes NI-DAQ DOS/Windows driver software for an IBM 486 personal computer. A Labview Full Development system for Windows is the graphical programming system being used. The system allows liquid level control to within 0.1 cm for all levels tried between 8 and 36 cm in the hydroponic system application. The detailed algorithms have been developed and a fully automated microprocessor based nutrient replenishment system has been described for this hydroponic system.

Smith, Boris

Improved Melt-Level Control System

Laser feedback control automatically maintains silicon melt levels. During long-term growth of dendritic-web silicon, silicon melt level controlled and held nearly constant using laser feedback system to sense level of melt and control silicon-pellet feed rate.

Meier, D. L.

Object-based task-level control: A hierarchical control architecture for remote operation of space robots

Expanding man's presence in space requires capable, dexterous robots capable of being controlled from the Earth. Traditional 'hand-in-glove' control paradigms require the human operator to directly control virtually every aspect of the robot's operation. While the human provides excellent judgment and perception, human interaction is limited by low bandwidth, delayed communications. These delays make 'hand-in-glove' operation from Earth impractical. In order to alleviate many of the problems inherent to remote operation, Stanford University's Aerospace Robotics Laboratory (ARL) has developed the Object-Based Task-Level Control architecture. Object-Based Task-Level Control (OBTLC) removes the burden of teleoperation from the human operator and enables execution of tasks not possible with current techniques. OBTLC is a hierarchical approach to control where the human operator is able to specify high-level, object-related tasks through an intuitive graphical user interface. Infrequent task-level command replace constant joystick operations, eliminating communications bandwidth and time delay problems. The details of robot control and task execution are handled entirely by the robot and computer control system. The ARL has implemented the OBTLC architecture on a set of Free-Flying Space Robots. The capability of the OBTLC architecture has been demonstrated by controlling the ARL Free-Flying Space Robots from NASA Ames Research Center.

Stevens, H. D.

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161 – 18 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch, a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes are proving an effective control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor

TV Video-Level Controller

Constant output maintained, though luminance varies by 5 million to 1. Three means of normalizing video output utilized in video-level controller: iris adjustment, tube voltage adjustment, and automatic gain control. With aid of automatic light control and gain control, television camera accommodates maximum light level 5 million times greater than lowest light level, while outputting constant 3-V peak signal to processing circuitry.

Kravitz, M.

Electronic circuit provides automatic level control for liquid nitrogen traps

Electronic circuit, based on the principle of increased thermistor resistance corresponding to decreases in temperature provides an automatic level control for liquid nitrogen cold traps. The electronically controlled apparatus is practically service-free, requiring only occasional reliability checks.

Turvy, R. R.

Three-Level Control of Manipulators

Concept for control of remote manipulators based on three-level hierarchy allows complex tasks performed in real time. Developed for interactive human/control with sensory feedback.

Zawacki, R. L.

Development and Demonstration of a Self-Calibrating Pseudolite Array for Task Level Control of a Planetary Rover

Pseudolites can extend the availability of GPS-type positioning systems to a wide range of applications not possible with satellite-only GPS. One such application is Mars exploration, where the centimeter-level accuracy and high repeatability of CDGPS would make it attractive for rover positioning during autonomous exploration, sample collection, and habitat construction if it were available. Pseudolites distributed on the surface would allow multiple rovers and/or astronauts to share a common navigational reference. This would help enable cooperation for complicated science tasks, reducing the need for instructions from Earth and increasing the likelihood of mission success. Conventional GPS Pseudolite arrays require that the devices be pre-calibrated through a Survey of their locations, typically to sub-centimeter accuracy. This is a problematic task for robots on the surface of another planet. By using the GPS signals that the Pseudolites broadcast, however, it is possible to have the array self-survey its own relative locations, creating a SelfCalibrating Pseudolite Array (SCPA). This requires the use of GPS transceivers instead of standard pseudolites. Surveying can be done either at carrier- or code-phase levels. An overview of SCPA capabilities, system requirements, and self-calibration algorithms is presented in another work. The Aerospace Robotics Laboratory at Statif0id has developed a fully operational prototype SCPA. The array is able to determine the range between any two transceivers with either code- or carrier-phase accuracy, and uses this inter-transceiver ranging to determine the at-ray geometry. This paper presents results from field tests conducted at Stanford University demonstrating the accuracy of inter-transceiver ranging and its viability and utility for array localization, and shows how transceiver motion may be utilized to refine the array estimate by accurately determining carrier-phase integers and line biases. It also summarizes the overall system requirements and architecture, and describes the hardware and software used in the prototype system.

Rock, Stephen M.

A two-level controller design approach for large space structures

A controller design approach is proposed for large space structures (LSS) using an Annular Momentum Control Device (AMCD). The controller consists of a primary attitude controller and a secondary or modal damping enhancement controller. It is proved that the LSS/AMCD system using the proposed damping enhancement controller is stable in the sense of Lyapunov regardless of the number of modes in the model and without the necessity of precise knowledge of the modal frequencies and mode shapes. Numerical results obtained for the secondary controller design for a large thin flat plate indicate that the proposed method can yield satisfactory damping enhancement with small weight penalty.

Joshi, S. M.