Comparison of The Dimensional Stability of Kel-F 81 and Neoflon CTFE M400H Polychlorotrifluoroethylenes Used in Valve Seat Application

The dimensional stability of polychlorotrifluoroethylene (PCTFE) valve seats used in oxygen regulator applications was determined by thermomechanical analysis (TMA). Two traceable grades of PCTFE were tested; Kel-F 81 and Neoflon CTFE M400H. For these particular resins, the effect of percent crystallinity, zero strength time (ZST) molecular weight, resin grade, process history (compression-molded versus extruded) on the dimensional stability and annealing behavior was determined. In addition to the traceable Kel-F 81 and Neoflon CTFE M400H grades, actual PCI'PH valve seats of differing geometry and design were tested by TMA. The PCTFE valve seats were of unspecified resin grade, although certain inferences about the grade could be drawn based on knowledge of the valve seat fabrication date. Results consistently revealed dimensional instability of varying magnitude at temperatures ranging from 40 to 70 degrees Celsius. Furthermore, some of the pre- 1 995 seats appeared to be more dimensionally stable than those fabricated after 1995. The TMA results are discussed in the context of several proposed ignition mechanisms; namely, particle impact, presence of contaminant oils and fibers, and localized heating by flow friction and/or resonance. The effect of metal constraint on the dimensional stability of PCTFE is also discussed. Finally, the effect of percent crystallinity, ZST molecular weight, resin grade, process history (compression-molded versus extruded) on the AIT, delta Hc and impact sensitivity of various types of Neoflon CTFE M400H was determined using Kel-F 81 as a control. Results show that the AIT, delta Hc and impact sensitivity were essentially independent of Neoflon CTFE process history and structure.

Waller, Jess M.↗

Hand-tightened, high-pressure seal

To provide flared tubing and hose connections for high-pressure hand tightened cryogenic service, a 1/4-inch male AN seal was modified by machining to receive a special, double-truncated-cone-shaped Kel-F washer between it and the flared flex hose connector.

Meyer, W. A.↗

High-pressure cryogenic seals for pressure vessels

This investigation of the problems associated with reliably containing gaseous helium pressurized to 1530 bars (22 500 psi) between 4.2 K and 150 K led to the following conclusions: (1) common seal designs used in existing elevated-temperature pressure vessels are unsuitable for high-pressure cryogenic operation, (2) extrusion seal-ring materials such as Teflon, tin, and lead are not good seal materials for cryogenic high-pressure operation; and (3) several high-pressure cryogenic seal systems suitable for large-pressure vessel applications were developed; two seals required prepressurization, and one seal functioned repeatedly without any prepressurization. These designs used indium seal rings, brass or 304 stainless-steel anvil rings, and two O-rings of silicone rubber or Kel-F.

Buggele, A. E.↗

A promising new cryogenic seal candidate

The Space Shuttle carries more than 500,000 kg of liquid oxygen (LO2) and 100,000 kg of liquid hydrogen (LH2) propellant. Seals for this main propellant system therefore must provide extremely high reliability under prolonged service at cryogenic temperatures. The chief threat to consistently reliable operation is not the cryogenic service itself, but the 325 K temperature variation encountered during each individual mission. Moreover, this reliability must be sustained during the entire 100-mission/ten-year projected life of the Space Shuttle. It was feared that conventional liquid oxygen seal materials (filled Teflon and Kel-F) could cold flow or compression set to such an extent during the high-temperature phases of the 100 successive missions that failures could result. Thus, in addition to LO2 compatibility and cryogenic serviceability, this program was directed toward seals that were not thermoplastic and had good compression set resistance

Merz, P. L.↗

High-pressure cryogenic seals for pressure vessels

Problems associated with maintaining high pressures at cryogenic temperatures in pressure vessels are investigated. The goals were to identify the appropriate materials and design for a seal intended for cryogenic applications at pressures up to 4,080 bars (60,000 psi), and to examine the factors affecting the seal performance. The method employed and the apparatus used in a series of experimental seal system tests, and the test results are described in detail. It is concluded that the common seal designs and extrusion seal-ring materials such as Teflon, tin, and lead are not suitable. However, new seal systems developed using indium seal rings, brass or 304 stainless steel anvil rings, and two 0-rings of silicone rubber or Kel-F did prove suitable.

Buggle, A. E.↗

Unique material requirements in the Space Shuttle Main Engines

Components operating in staged-combustion cycle liquid fuel rocket engines such as the Space Shuttle Main Engines (SSMEs) are subjected to severe temperature changes during start/stop transients, together with extremely high pressures, corrosive gases, high fluid velocities, demanding weight-control criteria, etc. Attention is given to the selection and application of metallic and nonmetallic materials for high temperature resistance, cryogenic properties, and hydrogen and oxygen compatibility. The materials in question include polyimides, Kel-F, Armalon, and Teflon among plastics, and gold and copper platings, weld-overlays and heat treatment modifications among metals and metallic processing techniques. The polymeric materials are oxygen-resistant, and the metallic ones hydrogen-resistant.

Fulton, D. L.↗

Evaluation of moisture barrier coatings on carbon-phenolic SRM nozzle materials

The carbon-phenolic composite ablative material used on the Solid Rocket Motor (SRM) nozzle is known to absorb moisture from the atmosphere. This could cause problems such as pocketing during firing. Several moisture barrier coatings were tested on the SRM nozzle material. Data are presented for six of the 12 coatings to be tested. The data were obtained from immersion of coated samples in an environmental chamber at 100 F and 100% relative humidity and by using a modified TGA (thermal gravimetric analysis) technique. The TGA technique involved allowing wet nitrogen (25 C, 80% relative humidity) to flow across a small sample at about 65 cu cm per minute while continually monitoring the weight increase. These preliminary results show Kel-F-800, a material supplied by 3M Corporation to be the better moisture barrier. A second task was to collect data on the relative absorption of water and kerosene into the carbon-phenolic SRM nozzle material. These data indicate that water absorbs into the nozzle material to a much greater extent than kerosene. Thus kerosene is the more likely solvent in which to make specific gravity measurements on the SRM nozzle material.

Mcnutt, Ronald C.↗

Low reflectance EUV materials - A comparative study

A study has been undertaken of the performance characteristics of a variety of surfaces and surface treatments for use on baffle materials in Extreme UV Explorer instrumentation, in order to ascertain which materials performed with the least overall scattering between 300 and 1200 A and thereby minimize this important background source. Seven scattering samples were measured: bead-blasted aluminum treated with alodine 600, bead-blasted aluminum, Kel-f, etched molybdenum, nickel-plated etched molybdenum, bead-blasted 304 stainless steel, and bead-blasted aluminum painted with Chemglaze Z-306. Attention is given to total reflectance of each material plotted against the graze angle for 304, 584, and 1216 A.

Jelinsky, Patrick↗

Rotor self-lubricating axial stop

A series of lubricating plugs is located in the stationary backup face adjacent to the axial stop face of a rotating impeller mounted in a turbopump for pumping liquid oxygen or liquid hydrogen. The stop face and the backup face are those surfaces which engage when the axial load on the impeller exceeds the load balancing capability. The plugs have a truncated conical configuration so as to be trapped in the backup face, and are placed at varying radii on the face to provide complete surface lubrication. The plugs may be formed from Teflon, Kel-F or bronze filled Teflon.

Blount, Dale H.↗

Bayonet for superfluid helium transfer in space

A prototype superfluid helium bayonet for potential space applications has been developed and evaluated with a low heat leak test apparatus. Measured heat leak of the 13 mm (1/2 inch) bayonet pair is 0.21 W at 1.8 K with an uncertainty of +0.09/-0.05 W. Bayonets are fabricated with thin, electron beam (EB) welded tubes which are EB welded to machined nose and flange pieces. Low heat leak structural integrity is provided by a 0.9 mm thickness of filament wound fiberglass-epoxy. Superfluid creep is restricted by KEL-F nose seals which form vacuum-tight extensions to the bayonet cold end pieces.

Mcintosh, G. E.↗

Ignition Resistance of Polymeric Materials to Particle Impact in High-Pressure Oxygen

Particle impact ignition has been the primary cause of numerous fires in oxygen systems. This ignition phenomenon is known to occur where particles are present in high-velocity gas, and where impact occurs on a flammable material. The particle impact ignition behavior of many metals has been widely studied, but the particle impact ignition behavior of polymeric materials is relatively unknown. Particle impact ignition in polymeric materials is a concern as these materials are commonly used in component seat and seal applications, where high-velocity particle impacts can occur. This study evaluates several polymeric materials and compares the minimum temperature required for ignition (threshold temperature) of these materials: Kel-F 81 (CTFE), Teflon (PTFE), PEEK, Vespel SP-21, and Nylon 6/6. The materials were configured as targets in the White Sands Test Facility high-velocity particle impact test system. Gaseous oxygen was flowed at 4000 psi and sonic velocity, and the targets were impacted with 2000-micron aluminum 2017 particles. This paper discusses the results of these tests and ranks the materials according to their threshold temperatures at these conditions.

Forsyth, Elliot T.↗

Rotor self-lubricating axial stop

A plurality of lubricating plugs are disposed in the stationary backup face adjacent to the axial stop face of a rotating impeller mounted in a turbopump for pumping liquid oxygen or liquid hydrogen. The stop face and the backup face are those surfaces which engage when the axial load on the impeller exceeds the load balancing capability. The plugs have a truncated conical configuration so as to be trapped in the backup face, and are disposed at varying radii on the face to provide complete surface lubrication. The plugs may be formed from Teflon, Kel-F or bronze filled Teflon.

Blount, Dale H.↗

Oxygen Compatibility of Brass-Filled PTFE Compared to Commonly Used Fluorinated Polymers for Oxygen Systems

Safe and reliable seal materials for high-pressure oxygen systems sometimes appear to be extinct species when sought out by oxygen systems designers. Materials that seal well are easy to find, but these materials are typically incompatible with oxygen, especially in cryogenic liquid form. This incompatibility can result in seals that leak, or much worse, seals that easily ignite and burn during use. Materials that are compatible with oxygen are easy to find, such as the long list of compatible metals, but these metallic materials are limiting as seal materials. A material that seals well and is oxygen compatible has been the big game in the designer's safari. Scientists at the Materials Combustion Research Facility (MCRF), part of NASA/Marshall Space Flight Center (MSFC), are constantly searching for better materials and processes to improve the safety of oxygen systems. One focus of this effort is improving the characteristics of polymers used in the presence of an oxygen enriched environment. Very few systems can be built which contain no polymeric materials; therefore, materials which have good impact resistance, low heat of combustion, high auto-ignition temperature and that maintain good mechanical properties are essential. The scientists and engineers at the Materials Combustion Research Facility, in cooperation with seal suppliers, are currently testing a new formulation of polytetrafluoroethylene (PTFE) with Brass filler. This Brass-filled PTFE is showing great promise as a seal and seat material for high pressure oxygen systems. Early research has demonstrated very encouraging results, which could rank this material as one of the best fluorinated polymers ever tested. This paper will compare the data obtained for Brass-filled PTFE with other fluorinated polymers, such as TFE-Teflon (PTFE) , Kel-F 81, Viton A, Viton A-500, Fluorel , and Algoflon . A similar metal filled fluorinated polymer, Salox-M , was tested in comparison to Brass-filled PTFE to demonstrate the importance of the metal chosen and relative percentage of filler. General conclusions on the oxygen compatibility of this formulation are drawn, with an emphasis on comparing and contrasting the materials performance to the performance of the current state-of-the-art oxygen compatible polymers.

Herald, Stephen D.↗