Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Ion Chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING

Three-chamber electrochemical reactor for selective lithium extraction from brine

Efficient lithium recovery from geothermal brines is crucial for the battery industry. Current electrochemical separation methods struggle with the simultaneous presence of Na + , K + , Mg 2+ , and Ca 2+ because these cations are similar to Li + , making it challenging to separate effectively. We address these challenges with a three-chamber reactor featuring a polymer porous solid electrolyte in the middle layer. This design improves the transference number of Li + (t Li+ ) by 2.1 times compared to the two-chamber reactor and also reduces the chlorine evolution reaction, a common side reaction in electrochemical lithium extraction, to only 6.4% in Faradaic Efficiency. Employing a lithium-ion conductive glass ceramic (LICGC) membrane, the reactor achieved high t Li+ of 97.5% in LiOH production from simulated brine, while the concentrations of Na + K + , Mg 2+ , and Ca 2+ are below the detection limit. Electrochemical experiments and surface analysis elucidated the cation transport mechanism, highlighting the impact of Na + on Li + migration at the LICGC interface.

Science & Technology - Other Topics

A New Era for Modern Bubble Chamber Technology: Cooling and Real-Time Control for the MAMBA Neutrino Bubble Chamber∗

Future neutrino experiments such as DUNE will be limited less by statistics than by how well neutrino--nucleus interactions are understood, and the cleanest way to improve that understanding is to measure interactions with light nuclei such as hydrogen or deuterium. The detector best suited to the job, the bubble chamber, has not been built for a neutrino beam in about fifty years. MAMBA (Modern Adaptive Modular Bubble chamber Archetype) is a small prototype at Fermilab intended to bring the technology back with modern cryogenics and automation, cycling continuously at 1~Hz. This paper summarizes my work on two of its subsystems during a summer internship. A new solid copper thermal link brought the coldhead to 21.3~K in a commissioning cooldown, near the 20~K operating target. An Industrial Shields Raspberry Pi programmable logic controller (PLC) running OpenPLC was characterized at a median round-trip response of 0.64~ms over 20,000 trials, with 0.66\% of trials exceeding 1~ms. Both results support continuous cycling.

Williams, Nicholas [Fermilab; DuPage Coll.]

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION

Handbook of Molecular Beam Epitaxy of Oxide Materials: Epitaxial Complex Oxide Growth on Semiconductors

This chapter covers the epitaxy of complex oxides on common inorganic semiconductors. The chapter opens with an introduction, motivating the subject and highlighting key general challenges (Section 6.1). We then proceed to describe the general steps of the growth procedure in Section 6.2, which concludes with an overall discussion about trade-offs and expectation management, with an emphasis on the oxide–semiconductor interface. From there, the text describes oxide growth on the common semiconductors, starting with silicon (Section 6.3), where surface reactions and oxidation are the most challenging aspects. Oxide epitaxy on germanium is described in Section 6.4, which is a less challenging oxide growth scheme on semiconductors. Section 6.5 describes oxide epitaxy on gallium arsenide, one of the more challenging schemes, where interface stability and surface preparation pose key challenges. Finally, in Section 6.6, oxide epitaxy on gallium nitride is described, where the lattice mismatch takes the stage as the key challenge. Altogether, this chapter aims to provide the reader with the practical knowledge, tactics and strategies for oxide epitaxy on semiconductors.

Demkov, Alexander A [The University of Texas at Au

Integrated Neutronics Modeling for Inertial Fusion Energy Systems: Development and Application to LD-FIRST

Lawrence Livermore National Laboratory (LLNL) is proposing a new Laser Driven Fusion Integration Research and Science Test Facility (LD-FIRST) with the goal of providing an experimental testbed for future Inertial Fusion Energy (IFE) systems. However, IFE systems require detailed and accurate multiphysics modeling to quantify material damage, thermal loading, and tritium breeding within complex chamber environments. This article presents the first step in an integrated multiphysics framework that couples meshed CAD-based geometry within Monte Carlo neutronic simulations to enable high-fidelity analysis of IFE chamber concepts, with future coupling to external codes. The neutronics workflow utilizes OpenMC and its third-party capability to use CAD-based geometries through DAGMC and tally on unstructured meshes with Libmesh to evaluate neutron transport behavior, geometric fidelity, and material performance under reactor-relevant conditions. The use of tailored tallies on unstructured meshes in this framework allows direct transfer without interpolating to CFD simulation tools. Two IFE chambers were evaluated, both conceived by LLNL: HYLIFE-II and Laser IFE (LIFE). This work produced high-fidelity conformal surface and volumetric meshes of the HYLIFE-II and LIFE chambers with mapped spatial insight into material damage, thermal loading, and tritium breeding. The HYLIFE-II model was built utilizing available resources and used as a test case to verify that the neutronics framework can handle complex geometries. The LIFE chamber CAD was provided by LLNL and was the main focus of this work. This work analyzes multiple ternary alloy breeding materials for the LIFE chamber, across different 6 Li enrichments to produce data relevant to the LD-FIRST project. This work also investigates the level of model fidelity for the LIFE chamber, and results show that inclusion of detailed first wall and coolant structures increased the predicted tritium breeding ratio (TBR) by ~30%, highlighting the sensitivity of tritium breeding and the need for a high-fidelity simulation framework for IFE chambers. These developments provide a scalable toolset for the design and optimization of next-generation IFE chambers, forming a solid foundation for future coupled multiphysics analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Demonstration of gold nanorod systems for enhanced total efficiency: Experimental and numerical analysis

This study investigates the photothermal performance of gold nanorods engineered to exhibit longitudinal plasmon resonances at 695 nm, 780 nm, and 970 nm. The work combines synthesis, structural characterization, extinction measurements, numerical modeling, and controlled temperature experiments to quantify how nanorod geometry, resonance tuning, concentration, and chamber shape jointly influence heat generation. Transmission electron microscopy confirms that increasing nanorod aspect ratio systematically shifts the longitudinal plasmon peak toward the near-infrared region. Extinction measurements show strong agreement with theoretical predictions, validating the numerical model across two independent datasets. Three chamber geometries were tested under laser excitation at 640 nm, 808 nm, and 980 nm: an ascending stepped base, a flat base, and a descending stepped base. Without nanorods, the ascending geometry produced the highest efficiency due to enhanced natural convection. After introducing gold nanorods, all geometries exhibited substantial thermal enhancement, with total efficiencies exceeding 20%. The strongest improvement was obtained for nanorods resonant at 780 nm with a mass concentration of 4.6 mg/mL implemented on the descending stepped-base geometry. This performance resulted from the combined effect of spectral overlapping with the 808 nm laser, the highest nanorod concentration, and localized heat accumulation that intensified buoyancy-driven flow. The findings demonstrate that total efficiency is governed by a synergistic interplay between optical resonance, nanoparticle concentration, and macroscopic chamber design, revealing the system-level coupling between nanoscale plasmonic absorption and macroscale heat-transfer phenomena. The results provide a validated framework for tuning nanoscale plasmonic absorbers and optimizing thermal systems for applications requiring efficient light-to-heat conversion.

77 NANOSCIENCE AND NANOTECHNOLOGY

Challenges and Prospects of Sodium‐Ion and Potassium‐Ion Batteries for Mass Production

The exponential growth of the lithium‐ion (LIB) market is causing a significant disparity between the supply chain and demand for its resources. In this regard, sodium‐ion and potassium‐ion batteries are promising alternatives to LIBs due to their low cost. However, the larger sizes of Na + and K + ions create challenges that prevent them from achieving energy densities comparable to LIBs while maintaining an acceptable cycle life. Here, in this perspective, the aim is to evaluate the status of Na‐ion and K‐ion batteries and the challenges associated with them on both fundamental and commercial levels. The focus is on the structural instability arising from phase transitions during cycling, intricate chemical degradation processes, and potential avenues for enhancing their performance with a specific goal of improving their viability for grid‐scale energy storage. Materials production and abundance limitations for the chemistries of the state‐of‐the‐art materials and account for critical parameters from both the perspective of researchers and investors are analyzed. This analysis aims to provide insights into the strategic trade‐offs required to effectively implement the technology in real‐world applications, such as grid‐scale storage and other areas. Furthermore, the utilization of metals with low or no supply‐chain problems as an important aspect of these trade‐offs is considered.

25 ENERGY STORAGE

Multi-Ion Complexes and Competition from Bulky BArF – Anions for Chloride Binding in Ion Pairing Conditions

Cationic charges have long been used to enhance anion binding. Embedding charge introduces strong ion pairing for target anions but also for off-target ions, ultimately generating a mixture of multi-ion species that are hard to identify and quantify. While many sidestep this problem using polar solvents and weakly coordinating ions, these approaches exclude a substantial cross-section of conditions found in applications spanning recognition, assembly, separations, templation, and catalysis. To confront this complexity, we study the binding of an anion to a cationic receptor featuring low shape complementarity in a low-polarity solvent to maximize ionic interactions. We prepared the receptor as a salt of the weakly coordinating tetrakis­[3,5-bis­(trifluoromethyl)­phenyl]­borate (BArF – ) anion and studied the binding of small chloride (Cl – ) and medium-sized iodide (I – ) anions. Surprisingly, the use of the bulky BArF – anion does not suppress ion pairing interactions, with 65% of the receptor being paired at 0.5 mM in dichloromethane. We observe multi-ion receptor-Cl – complexes (2:1, 1:1, 1:2), reinforcing the complexity that emerges when working in low-polarity media. Here, we reveal the dependence of affinity on anion charge density and size and that bulky BArF – counteranions compete for chloride binding. These studies reveal the noninnocence of BArF – anions and strategies to quantify multi-ion species.

Ion pairing

Advancements in nanocomposites for enhancing the performance of rechargeable lithium-ion batteries

The benefits of nanotechnology have been realized in almost every component of lithium-ion batteries. From electrodes to electrolytes, the incorporation of nanoparticles as dopants and coatings has shown marked improvements in cell cycle life, efficiency, mechanical and thermal stabilities, and lithium-ion transport. The improvements realized depends on several factors, from processing methods, nanoparticle type, structure, and concentration, to the material into which the nanoparticulate will be incorporated. Regardless of these many factors, nanotechnology has vastly improved the performance of secondary lithium-ion batteries. Here we will highlight some of the works that demonstrate these improvements and the quantitative benefits of nanotechnology.

25 ENERGY STORAGE

Gating ion and fluid transport with chiral solvent

Nonlinear spectroscopy and electrokinetic measurements reveal that the electrochemical properties of a solid–liquid interface in salt solutions in propylene carbonate are dependent on the solvent chirality.

Chemistry