Innovative duo-recombination layer design for effective hydrogen crossover mitigation in advanced MEAs for PEM water electrolyzers

Hydrogen crossover in proton exchange membrane water electrolyzers (PEMWEs) poses a safety hazard, reduces the overall efficiency, and limits the operational differential pressure range. Here, in this study, a membrane electrode assembly (MEA) with innovative Pt duo-recombination layer (DRL) design is developed by the unique reactive spray deposition technology (RSDT). The novel design comprises two thin RLs integrated within the volume of the membrane and has a total Pt loading of only 0.04 mg Pt cm −2 . Long-term durability test for over 3000 h is performed with as-fabricated MEA at steady-state conditions typical for an industrial hydrogen production system. The results from the durability test show that the newly developed DRL design effectively suppresses the H2 crossover to below 0.5 vol%. Furthermore, comprehensive post-test characterization of the MEA is performed and potential failure mechanisms in the Pt RLs observed during the durability test are identified and discussed in detail for the first time.

08 HYDROGEN

Advanced PEM Electrolyzer Membrane for Hydrogen Crossover Mitigation

An unintended reaction in the electrochemical conversion of water to hydrogen in proton exchange membrane (PEM) electrolyzers is the crossover of hydrogen from the anode to the oxygen-containing cathode through the membrane, creating hydrogen losses and safety concerns. Efforts to date have focused on embedding platinum catalysts in perfluorosulfonic (PFSA) membranes to convert H 2 to protons. The objective of this project is to design and develop hydrocarbon (HC) proton exchange membranes (PEMs) that can help overcome the risk of high H 2 crossover in current PEM electrolyzer (ELX) stacks by designing and optimizing the gas recombination catalyst (GRC) within the membrane and membrane electrode assembly (MEA) structure.

08 HYDROGEN

Mitigation of hydrogen crossover in liquid alkaline water electrolysers using gas recombination catalysts

The rising demand for hydrogen calls for improvements in the efficiency of liquid alkaline water electrolysers (LAWEs), which can be fulfilled by advanced electrodes or separators. Nevertheless, they also intensify hydrogen crossover and safety concerns, thus mandating efficient mitigation strategies. Here we studied the correlation between cathodes and hydrogen crossover behaviours and mitigated safety risks by designing a gas recombination catalyst (GRC). We attribute the elevated hydrogen crossover associated with platinum-based cathodes to their preferential utilization for the hydrogen evolution reaction that creates elevated hydrogen supersaturation, as evidenced by direct measurements of dissolved hydrogen concentration. Varying the placement of platinum layers relative to the cathode–separator interface also supports this conclusion. The implementation of a GRC reduces hydrogen crossover by 95% without affecting LAWE performance and functions for over 1,000 h at 1 A cm−2. This study provides insights into hydrogen supersaturation and the crossover mechanism, as well as offering a promising pathway to enhance the efficiency and reliability of alkaline water electrolysis.

Liu, Haotian

Performance and Durability Investigation of Thin, Low Crossover Proton Exchange Membranes for Water Electrolyzers

The goal of this project was to fabricate and study the performance and durability implications of thin, mechanically reinforced membranes containing gas recombination catalysts (GRCs) for advanced proton exchange membrane water electrolysis (PEMWE) systems. The thinner membranes, optimized for a PEMWE environment, dramatically reduced the proton transport resistance across the membrane, improving the overall efficiency of the PEMWE system. At the same time, the GRC technology was deployed to recombine crossover hydrogen from the cathode with oxygen from the anode to form water within the membrane. This reaction mitigated the buildup of hydrogen in the oxygen stream, ensuring safe operation of the PEMWE system. Capabilities to measure the gas crossover in both an ex-situ screening cell and in operando application testing were developed over the course of the project to track membrane progress and quantify deliverables. State of the art roll to roll manufacturing technologies were leveraged to fabricate the membranes on a commercial scale, where the membrane structure was precisely tuned and GRC distributed within the membrane structure.

08 HYDROGEN

Mitigating Hydrogen-Induced Degradation of Iridium Anodes in Proton Exchange Membrane Water Electrolyzers

One promising method for reducing precious metal usage in proton exchange membrane water electrolysis is lowering iridium (Ir) loading at the anode. However, low-loading Ir catalysts often suffer from poor stability under high current densities. In this study, hydrogen (H2) crossover from the cathode to the anode is identified as a key degradation pathway. Temperature-programmed reduction confirms the reduction of IrO2 at 80 °C in a hydrogen environment, highlighting the vulnerability of IrO2-based catalysts to H2 exposure. To mitigate this effect, palladium (Pd) is introduced as an anode additive, acting as an H2 oxidation catalyst and mitigating IrO2 reduction. This protective role is verified by inductively coupled plasma optical emission spectroscopy and in situ X-ray absorption spectroscopy, showing significantly suppressed Ir dissolution at 80 °C under H2 flow when an O-covered Pd surface is present at oxygen evolution reaction potentials. Results from the current study identify a new strategy in improving activity and durability of catalysts in electrolyzers.

58 GEOSCIENCES

The impact of hot-press conditions on the durability of polymer electrolyte membrane fuel cells

The proton exchange membrane integrity can be compromised during hot-press fabrication of membrane electrode assemblies (MEAs) causing premature cell failures during operation. In this work, infrared (IR) thermography was used as a diagnostic tool to spatially visualize hydrogen (H 2 ) crossover and identify process-induced-membrane irregularities (PIMs). These irregularities were identified as seed locations for MEA failures. Fine tuning of hot-press conditions was used to mitigate premature cell failures informed by accelerated stress testing (AST). The impact of PIMs on the initial performance, high-frequency resistances, open-circuit voltage, and H 2 crossover are reported. Nafion XL and 212 membranes, hot-pressed with a force of 16 kg/cm 2 and temperature of 120°C, were found to be consistently irregularity-free. Irregularity-free MEAs using Nafion 211, 212, and XL membranes demonstrated AST lifetime improvements of 58, 64 and 400%, respectively, compared to those fabricated with non-optimized conditions. In conclusion, this work highlights the importance of fabrication parameters on premature cell failures.

08 HYDROGEN

Nanoscopic Plugs Block Hydrogen Crossover in Submicron Thick Proton-Conducting SiO 2 Membranes for Water Electrolysis

Zero-gap electrolyzers based on submicron thick proton-conducting oxide membranes (POMs) represent a promising approach to increasing the efficiency of H 2 production from water electrolysis while moving away from conventional perfluorosulfonic acid (PFSA) membranes. A critical barrier to the commercialization of such electrolyzers is that the ultrathin nature of POMs, which is necessary to achieve low cell resistance, makes them more susceptible to defects that can lead to unacceptably high rates of H 2 crossover. Herein, we demonstrate an approach to mitigate this problem through selective deposition of carbon-containing silicon oxide (SiO x C y ) “nanoplugs” into the defects of submicron thick SiO 2 membranes using a facile electrochemically mediated deposition process. Selective deposition of nanoplugs within the defects was verified by multiple characterization techniques, while scanning electrochemical microscopy (SECM) was used to confirm selective plugging of H 2 -crossover hotspots associated with defects at identical locations. Thanks to the use of nanoplugs, the H 2 permeance of 250 nm thick SiO 2 membranes was reduced by 5 to 6 orders of magnitude compared to the unmodified atomic layer deposition (ALD) SiO 2 membranes while having negligible impact on the ionic resistance of the membrane. These plug-modified membranes also enabled safe and stable operation of a zero-gap full cell electrolysis cell, in contrast to cells lacking nanoplugs that produced anode effluent streams having H 2 concentrations near or exceeding the lower flammability limit (LFL) of H 2 . Furthermore, beyond water electrolysis, this defect-sealing strategy has the potential to be broadly implemented in other applications, such as fuel cells and flow batteries, offering a versatile solution to mitigate crossover-related performance losses.

ALD SiO2