At least 19 records

Constraints on the chemical enrichment history of the Perseus Cluster of galaxies from high-resolution X-ray spectroscopy

High-resolution spectroscopy of the core of the Perseus Cluster of galaxies, using the Hitomi satellite above 2 keV and the XMM–Newton Reflection Grating Spectrometer at lower energies, provides reliable constraints on the abundances of O, Ne, Mg, Si, S, Ar, Ca, Cr, Mn, Fe, and Ni. Accounting for all known systematic uncertainties, the Ar/Fe, Ca/Fe, and Ni/Fe ratios are determined with a remarkable precision of less than 10 per cent, while the constraints on Si/Fe, S/Fe, and Cr/Fe are at the 15 per cent level, and Mn/Fe is measured with a 20 percent uncertainty. The average biases in determining the chemical composition using archival CCD spectra from XMM–Newton and Suzaku typically range from 15 to 40 per cent. A simple model in which the enrichment pattern in the Perseus Cluster core and the protosolar nebula are identical gives a surprisingly good description of the high-resolution X-ray spectroscopy results, with X^2=10.7 for 10 degrees of freedom. However, this pattern is challenging to reproduce with linear combinations of existing supernova nucleosynthesis calculations, particularly given the precise measurements of intermediateα-elements enabled by Hitomi. We discuss in detail the degeneracies between various supernova progenitor models and explosion mechanisms, and the remaining uncertainties in these theoretical models. We suggest that including neutrino physics in the core-collapse supernova yield calculations may improve the agreement with the observed pattern ofα-elements in the Perseus Cluster core. Our results provide a complementary benchmark for testing future nucleosynthesis calculations required to understand the origin of chemical elements.

A Simionescu↗

High resolution X-ray spectroscopy using microcalorimeters

The use of microcalorimeters for high-resolution, high quantum efficiency, nondispersive X-ray spectroscopy has been demonstrated over the past few years. In this paper, the principles of X-ray calorimetry are reviewed, and the results of ongoing X-ray tests using microcalorimetry are summarized. An approach to building an X-ray calorimeter spectrometer is discussed.

Kelley, R. L.↗

High Resolution X-Ray Spectroscopy Using Microcalorimeters

During the past 13 years high resolution X ray spectrometers have been developed that use cryogenically cooled microcalorimeters. These devices have inherently high signal-to-noise by operating at temperatures below 0.1 K and can achieve an energy resolution of < 10 eV over the 0.1-10 keV band. Existing devices use doped semiconductor thermometers and typically employ HgTe absorbers. The energy resolution depends on achieving a low heat capacity for the device. For soft X ray applications a relatively thin absorber (approximately 1 micrometer) may be used and an energy resolution of approximately 7 eV has been achieved. For applications up to approximately 10 keV an absorber thickness of approximately 10 micrometer is required and the energy resolution is typically approximately 12 eV. Improvements to the energy resolution in this energy band could be achieved if the problems of thermalizing X rays in low heat capacity superconductors can be overcome. The recent work on transition edge thermometers by Irwin et nl. looks particularly promising because of the higher sensitivity achievable from a sharp superconducting transition. The relatively low impedance of such a device permits the use of a low noise SQUID amplifier for readout. This would also significantly reduce the cryogen heat load compared with JFETs required by higher impedance semiconductor thermometers.

Kelley, R. L.↗

The XMM-Newton View of Stellar Coronae: High-Resolution X-Ray Spectroscopy of Capella

We present the high-resolution RGS spectrum of the bright stellar binary Capella observed by the XMM-Newton satellite. A multi-thermal approach has been applied to fit the data and derive elemental abundances. The differential emission measure distribution is reconstructed using a Chebychev polynomial fit. The DEM shape is found to display a sharp peak around 7 MK, consistent with previous EUVE and ASCA results. A small but significant amount of emission measure is required around 1.8 MK in order to explain the O VII He-like triplet and the C VI Ly(alpha) line. Using the sensitivity to temperature of dielectronic recombination lines from O VI around 22 A, we confirm that the cool plasma temperature needs to be higher than 1.2 MK. In the approximation of a cool plasma described by one temperature, we used line ratios from the forbidden, intercombination, and resonance lines of the O VII triplet and derived an average density for the cool coronal plasma at the low density limit. A tentative study of line ratios from the M XI triplet gives an average temperature close to the sharp peak in emission measure and an average density of the order of 10(exp 12)cu cm, three orders of magnitude higher than for O VII. Implications for the coronal physics of Capella are discussed. We complement this paper with a discussion of the importance of the atomic code uncertainties on the spectral fitting procedure.

Audard, M.↗

High-resolution X-ray spectroscopy of M87 with the Einstein observatory - The detection of an O VIII emission line

The paper deals with high-resolution X-ray spectroscopy performed to study the extended source surrounding the giant elliptical galaxy, M87, in the Virgo cluster. From observations carried out with a focal plane crystal spectrometer, L-alpha emission was detected from hydrogenic oxygen (O VIII). Upper limits could be set on lines from intermediate ionization states of iron. The presence of a quantity of cooler matter surrounding M87 was revealed, which has important implications for cluster models and favors a radiatively controlled accretion mechanism.

Canizares, C. R.↗

Goals for the application of high-resolution X-ray spectroscopy to the diagnosis of stellar coronal plasmas

Examples are provided of how high-resolution X-ray spectra may be used to determine the temperature and emission measure distributions, electron densities, steady and transient flow velocities, and location of active regions in stellar coronas. For each type of measurement, the minimum spectral resolution required to resolve the most useful spectral features is estimated. In general, high sensitivity is required to obtain sufficient signal-to-noise to exploit the high spectral resolution. Although difficult, each measurement should be achievable with the instrumentation proposed for AXAF.

Linsky, Jeffrey L.↗

High Resolution X-Ray Spectroscopy of zeta Puppis with the XMM-Newton Reflection Grating Spectrometer

We present the first high resolution X-ray spectrum of the bright O4Ief supergiant star Puppis, obtained with the Reflection Grating Spectrometer on- board XMM-Newton. The spectrum exhibits bright emission lines of hydrogen-like and helium-like ions of nitrogen, oxygen, neon, magnesium, and silicon, as well as neon-like ions of iron. The lines are all significantly resolved, with characteristic velocity widths of order 1000 - 1500 km/ s. The nitrogen lines are especially strong, and indicate that the shocked gas in the wind is mixed with CNO-burned material, as has been previously inferred for the atmosphere of this star from ultraviolet spectra. We find that the forbidden to intercombination line ratios within the helium-like triplets are anomalously low for N VI, O VII, and Ne IX. While this is sometimes indicative of high electron density, we show that in this case, it is instead caused by the intense ultraviolet radiation field of the star. We use this interpretation to derive constraints on the location of the X-ray emitting shocks within the wind that agree remarkably well with current theoretical models for this system.

Kahn, S. M.↗

High-resolution X-ray spectroscopy of four active galaxies - Probing the intercloud medium

The focal plane crystal spectrometer (FPCS) on the Einstein Observatory has been used to perform a high-resolution spectroscopic search for oxygen X-ray line emission from four active galaxies: Fairall 9, Mrk 421, Mrk 501, and PKS 0548 - 322. Specifically, O VIII Ly-alpha and Ly-beta, whose unredshifted energies are 653 and 775 eV, respectively, were sought. No narrow-line emission was detected within the energy bands searched. Upper limits are calculated on the line flux from these sources of 30 eV equivalent width and use a photoionization model to place corresponding upper limits on the densities of diffuse gas surrounding the active nuclei. The upper limits on gas density range from about 0.02-50/cu cm and probe various radial distances from the central source. This is the first time high-resolution X-ray spectroscopy has been used to place constraints on the intercloud medium in active galaxies.

Lum, Kenneth S. K.↗

High-Resolution X-Ray Spectroscopy of the Galactic Supernova Remnant Puppis A with the XMM-Newton RGS

We present high-resolution X-ray spectra of cloud-shock interaction regions in the eastern and northern rims of the Galactic supernova remnant Puppis A, using the Reflection Grating Spectrometer onboard the XMM-Newton satellite. A number of emission lines including K(alpha) triplets of He-like N, O , and Ne are clearly resolved for the first time. Intensity ratios of forbidden to resonance lines in the triplets are found to be higher than predictions by thermal emission models having plausible plasma parameters. The anomalous line ratios cannot be reproduced by effects of resonance scattering, recombination, or inner-shell ionization processes, but could be explained by charge-exchange emission that should arise at interfaces between the cold/warm clouds and the hot plasma. Our observations thus provide observational support for charge-exchange X-ray emission in supernova remnants.

Katsuda, Satoru↗

High-resolution X-ray spectroscopy of the Crab Nebula and the oxygen abundance of the interstellar medium

The measurement and analysis of a high-resolution soft X-ray spectrum of the Crab Nebula obtained with the Focal Plane Crystal Spectrometer on the Einstein Observatory are reported. A hydrogen column density of 3.45 + or - 0.42 x 10 to the 21st/sq cm and an oxygen column density of 2.78 + or - 0.55 x 10 to the 18th/sq cm, corresponding to an oxygen abundance of 1.1 + or - 0.3 times solar, were obtained. The absence of any evident oxygen depletion effects suggests that most interstellar grains are reasonably transparent to soft X-rays, implying sizes of less than 0.4 micron. The detailed spectrum in the vicinity of the oxygen edge gives marginal evidence for a resonant absorption line and suggests an edge from singly ionized oxygen.

Schattenburg, M. L.↗

High resolution X-ray spectroscopy of active galactic nuclei

After a brief review of the principal problems of AGN research, selected potential high-resolution observations are discussed with a view toward assessing their scientific value and the degree of resolution they will require. Two classes of observations pertaining directly to AGNs are discussed. Fe K-alpha spectroscopy relevant to the dynamical and thermal character of the emission line zones; and measurement of resonance line absorption by highly-ionized species in BL Lac objects, which should provide information about entrainment of interstellar material by relativistic jets. A third class of potentially important observations uses AGNs as background light sources in order to directly measure the distance to clusters of galaxies.

Krolik, Julian H.↗

High-Resolution X-Ray Spectroscopy of the Seyfert 2 Galaxy Circinus with Chandra

Results from a 60 ks Chandra High Energy Transmission Grating Spectrometer (HETGS) observation of the nearby Seyfert 2 Circinus are presented. The spectrum shows a wealth of emission lines at both soft and hard X-rays, including lines of Ne, Mg, Si, S, Ar, Ca, and Fe, and a prominent Fe K(alpha) line at 6.4 keV. We identify several of the He-like components and measure several of the Lyman lines of the N-like ions. The lines' profiles are unresolved at the limited signal-to-noise ratio of the data. Our analysis of the zeroth-order image in a companion paper constrains the size of the emission region to be 20-60 pc, suggesting that emission within this volume is almost entirely due to the reprocessing of the obscured central source. Here we show that a model containing two distinct components can reproduce almost all the observed properties of this gas. The ionized component can explain the observed intensities of the ionized species, assuming twice-solar composition and an N is proportional r(exp -1.5) density distribution. The neutral component is highly concentrated, well within the 0.8" point source, and is responsible for almost all of the observed K(alpha) (6.4 keV) emission. Circinus seems to be different than Mkn 3 in terms of its gas distribution.

Sambruna, Rita M.↗

The MIT high resolution X-ray spectroscopy instruments on AXAF

The general design and performance characteristics of MIT's two dispersive spectrometers, the Bragg Crystal Spectrometer (BCS) and the High Energy Transmission Grating Spectrometer (HETG), now being developed for the Advanced X-ray Astrophysics Facility (AXAF), are described. Particular attention is given to the development of the critical technologies incorporated into these instruments, including BCS diffractors, imaging gas flow proportional counters, and grating elements for the HETG. The principal stages and the current status of the developments are reviewed.

Canizares, C. R.↗

High Resolution X-Ray Spectroscopy and Imaging of Supernova Remnant N132D

The observation of the supernova remnant N132D by the scientific instruments on board the XMM-Newton satellite is presented. The X-rays from N132D are dispersed into a detailed line-rich spectrum using the Reflection Grating Spectrometers. Spectral lines of C, N, O, Ne, Mg, Si, S, and Fe are identified. Images of the remnant, in narrow wavelength bands, produced by the European Photon Imaging Cameras reveal a complex spatial structure of the ionic distribution. While K - shell Fe seems to originate near the centre, all of the other ions are observed along the shell. An emission excess of O(6+) over O(7+) is detected on the northeastern edge of the remnant. This can be a sign of hot ionising conditions, or it can reflect a relatively cool region. Spectral fitting of the CCD spectrum suggests high temperatures in this region, but a detailed analysis of the atomic processes involved in producing the O(6+) spectral lines leads to the conclusion that the intensities of these lines alone cannot provide a conclusive distinction between the two scenarios.

Behar, Ehud↗

Microcalorimeters for High Resolution X-Ray Spectroscopy of Laboratory and Astrophysical Plasmas

The proposal has three major objectives. The first focuses on advanced neutron-transmutation-doped (NTD)-based microcalorimeter development. Our goal is to develop an array of microcalorimeters with sub- 5 eV energy resolution that can operate with pile-up-free throughput of at least 100 Hz per pixel. The second objective is to establish our microcalorimeter as an essential x-ray diagnostic for laboratory astrophysics studies. We propose to develop a dedicated microcalorimeter spectrometer for the EBIT (electron beam ion trap). This instrument will incorporate the latest detector and cryogenic technology that we have available. The third objective is to investigate innovative ideas related to possible flight opportunities. These include compact, long lived cryo-systems, ultra-low temperature cold stages, low mass and low power electronics, and novel assemblies of thin windows with high x-ray transmission.

Silver, E.↗

Galactic X-ray polarimetry and high-resolution X-ray spectroscopy.

Stellar X-ray spectroscopy and polarimetry are discussed in terms of the source parameters that can be determined through such studies and in terms of the constraints that these studies will place on theoretical models. The spectroscopic and polarimetric results that have been obtained to date are reviewed. These include the recent discovery of X-ray polarization in the Crab Nebula and the recent evidence for X-ray coronal line emission in the Cygnus Loop. Finally, the properties and predicted performance of a number of satellite-borne spectrometers and polarimeters are presented.

Novick, R.↗