Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Heat Exchanger (HE) Evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluating Microchannel Heat Exchanger Lifetime for Concentrating Solar Power Applications

This report presents thework and results of a SolarEnergyTechnologyOffice (SETO) funded project to evaluate the lifetime of advanced microchannel etched and diffusion bonded heat exchangers for use in Generation 3 concentrated solar power (CSP) plants. Such plants transfer heat from a high temperature solid media to supercritical carbon dioxide (sCO2) via a primary heat exchanger in order to drive advanced Brayton cycles with turbine inlet temperatures greater than 700 °C.

Sandlin, Matthew James [Sandia National Laboratori

Evaluating Microchannel Heat Exchanger Lifetime for Concentrating Solar Power Applications Research Performance Progress Report (RPPR-1)

Microchannel heat exchanger technology is being pursued for next generation CSP concepts for primary power cycle heat addition and power cycle heat recuperation due to the high heat transfer coefficients and pressure containment advantages of small sCO 2 channels. The economics of future CSP plants as dictated by the SETO 2020 or 2030 targets depend on a heat exchanger with a 30-year lifetime (resisting creep, fatigue, corrosion, erosion) and operational characteristics such as fast ramping and the ability to withstand thermal shock. However, the lifetime and operational limits of microchannel heat exchangers operating at high temperatures, particularly those constructed from high-nickel alloys, are not well known. This uncertainty has resulted in heat exchanger vendors not being able to accurately forecast heat exchanger lifetime as required by customers, specify operational limits as required by process engineers to prevent premature heat exchanger failure, or overdesign heat exchanger which leads to higher cost than necessary.

14 SOLAR ENERGY

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS

Comparative evaluation and selection of heat exchangers using multicriteria decision-making

Here, this study presents a well-structured method for comparing and selecting Heat Exchanger (HE) technologies for Integrated Energy Systems (IES). The decision to select a HE for a particular IES configuration can vary greatly depending not only on engineering requirements but also on customer’s specific demand. In other words, the HE selection for IES requires a multicriteria decision-making approach, taking into account diverse technical, economic, and safety aspects, as well as the relative priorities considered by energy users. This study employs a HE evaluation approach combining multicriteria decision-making techniques widely used in various industries: quality function deployment (QFD) and analytic hierarchy process (AHP) techniques. Of particular interest is the use of the proposed method to select a high-temperature HEs that couples advanced nuclear reactors and industrial processes. To build a practical basis for comparing HEs within the proposed framework, efforts were made to identify the various HEs requirements for IES purposes. In addition, leveraging the insights obtained from the literature review and the market survey of commercial HE suppliers, a knowledge base was built to facilitate the comparison of each requirement across various HE designs. Also, evaluation metrics were identified for HE requirements with robust rational to enhance the quality of decisions made throughout the proposed evaluation process. The evaluation procedure and knowledge base described in this study can provide a useful basis for those interested in screening the appropriate HE designs for various IES scenarios.

Analytic Hierarchy Process (AHP)

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE

A Novel Framework for Performance Evaluation and Design Optimization of PCM Embedded Heat Exchangers for the Built Environment

This research sheds light on the performance evaluation and design optimization of PCM-HXs for the built environment, addressing several barriers to practical issues to PCM-HX commercialization such as modeling aspects (i.e., modeling expertise and computational / time investment, etc.), manufacturing aspects (i.e., at-scale manufacturing, cost assessments, etc.) and experimental performance assessment (i.e., reliable experimental data, assessment of multiple PCM-working fluid combinations, etc.). We present a novel, comprehensive, and experimentally-validated design optimization framework for PCM-HXs capable of simulating any PCM-HX geometry with reasonable accuracy and significant computational time savings when compared to traditional CFD-based design practices. The framework was validated for a wide range of PCM-HX configurations, including a design optimization for a domestic hot water heater application where TES partially replaces electrical heating input. The resulting PCM-HXs were found to deliver 34-68% of the total daily hot water supply with only 5-10% package volume increase from the water heater, thus within U.S. DOE targets for TES systems. To identify the most promising HXs for PCM applications, first-order geometry and cost analyses were conducted based on off-the-shelf HX products. As part of this work, 9 PCM-HX prototypes were manufactured using additive and conventional manufacturing methods. Detailed economy-of-scale assessments were conducted for the most promising PCM-HXs and were found to have a good outlook for the next 5-10 years. The PCM-HX design optimization framework was validated through comprehensive in-house experimental testing using newly-developed PCM-to-fluid test facilities. In total,10 total in-house component-level experiments were conducted using these prototypes, including 9 with water and 1 with refrigerant (R410A) as the working fluid. It was found that the framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time without manual design changes, eliminating the need for time-consuming and expensive prototyping efforts as part of the design process. As part of this work, a publicly-available PCM web tool was released which includes a PCM property database (531 PCMs) and PCM-HX modeling tool to assist the design community on common PCM-HX use-cases, e.g., single/multiple flow path(s) fluid-to-PCM and air-to-fluid-to-PCM configurations (https://ceeeweb.umd.edu/pcmapp/). This work will accelerate the design and time to market for next generation PCM-HXs.

25 ENERGY STORAGE

Surface roughness and dimensional evaluation of laser powder bed fusion additively manufactured shell and tube heat exchangers

The growing interest in additively manufactured (AM) heat exchangers drove the need to understand how this construction technique impacts heat exchanger performance. Two primary factors driven by AM that influence heat exchanger performance are surface roughness and geometry. To better understand these parameters, a range of shell and tube heat exchangers constructed using laser powder bed fusion were evaluated. Of those evaluated, the surface roughness throughout a fourteen-tube, zero-baffle heat exchanger was measured using computed tomography. Between the inner and outer tubes, the inner tube surfaces had a greater surface roughness than the outer by 8.07 μm, while the surfaces at the top of the build volume had higher surface roughness values than the bottom. Dimensionally, the inner tube diameters of this heat exchanger were 0.15% different from the design value, while the outer diameters were within a 0.84 % difference. Manual measurements across seven other heat exchangers yielded a maximum 1.15% difference between the design and measured diameters. Across the build volume for all heat exchangers studied, the tube diameters at the top were larger than at the bottom by a maximum of 1.24% difference. Inconsistent melting throughout the individual parts and the build volume, as well as particle splatter and thermal gradient variation were attributed to the surface roughness and dimensional changes seen. These results strengthen the knowledge of dimensional and surface roughness considerations when designing AM heat exchangers.

36 MATERIALS SCIENCE

Printed circuit primary heat exchanger for power conversion in heat pipe microreactor applications

Here, in the present study, a model was developed for a recuperated air Brayton cycle for heat pipe microreactors, and the effect of the primary heat exchanger type assessed. An annular flow heat exchanger and a printed circuit heat exchanger (PCHE) were evaluated. A sub-sized diffusion bonded, PCHE test specimen was manufactured and tested with nitrogen as the working fluid to validate and improve the PCHE model. A comparison of the thermal cycle efficiency for the Brayton cycle coupled to a heat pipe microreactor using each of the two primary heat exchangers showed competitive performance for both options, with achievable cycle efficiencies of 34 % and 35 % for the annular and printed circuit heat exchangers, respectively. The impact of heat pipe length and additional reheating stages on cycle efficiency was studied. Increasing the heat pipe condenser length from 0.8 to 2.0 m resulted in an increase in cycle efficiency of 3.5 % and 3.2 % for the annular and printed circuit heat exchangers, respectively. The use of additional reheating stages showed a reduction in cycle efficiency since the heat pipe surface area limits the primary heat exchanger size and effectiveness. These results highlight the importance of the primary heat exchanger on the performance of a heat pipe microreactor. Overall, the cycle model, testing, and heat exchanger model showed the potential for the PCHE to improve the economics of a heat pipe microreactor relative to the annular flow heat exchanger, which also opens the possibility to use different heat transfer fluids such as supercritical CO 2 .

PCHE

Pinch Heat Integration Tool (PIT) v0.9

The pinch heat integration tool (PIT) is a multi-module tool designed for identifying and analyzing thermal energy integration at facilities. It generates pinch and grand composite curves to identify optimal streams for heat exchange and industrial heat pumps. Users input heating and cooling stream data via an Excel sheet. The tool comprises four modules: 1. 'Main Pinch' for creating a pinch diagram using user-provided data. 2. 'GCC' for generating a grand composite curve to identify utility optimization opportunities. 3. 'Heat Exchanger' for analyzing stream combinations for heat exchange. 4. 'Heat Pump' for evaluating streams as sources and sinks for heat pumps and calculating the heat pump's coefficient of performance based on the selected refrigerant.

Karki, Unique [Lawrence Berkeley National Laborato

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY

Development of a Test-Bed for Testing and Refining EarthEn’s Supercritical CO 2 Based Energy Storage System

EarthEn’s energy storage concept leverages supercritical carbon dioxide (sCO 2 ) as a working fluid and relies on compact, high-performance components operating at elevated pressures and temperatures. To accelerate component development and reduce technical risk prior to larger-scale demonstrations, Oak Ridge National Laboratory (ORNL) developed a 100 kW-scale sCO 2 test-bed under a Cooperative Research and Development Agreement with EarthEn (CRADA NO. NFE-24-10050). The objective of the work was to design and construct a flexible experimental facility capable of reproducing key thermodynamic state points and heat-transfer conditions relevant to EarthEn’s thermal energy storage (TES) cycle, with particular emphasis on enabling development and evaluation of next-generation heat exchangers and TES concepts. The test-bed consists of a closed-loop sCO 2 circulation system housed within an open-topped enclosure. In its as-installed configuration, dense-phase sCO 2 is recirculated through a printed circuit recuperator, an electrically heated section, a throttling device used to simulate turbine expansion, and a water-cooled printed circuit heat exchanger that rejects heat to the building chilled-water system before returning to the pump. The pump is driven by a variable frequency drive, enabling controlled adjustment of flow and operating point. A comprehensive instrumentation suite was integrated to support both safe operation and high-quality data collection. Installed sensors include Coriolis flow meters for sCO 2 flow rate and density, resistance temperature detectors and thermocouples distributed throughout the loop (including the heated section and key heat exchanger ports), and pressure transducers for absolute and differential pressure measurements. The facility was designed to support high-pressure (19 MPa nominal) and high-temperature (575°C nominal) operation with credited overpressure protection provided by a rupture disk. Nominal operating conditions were selected to support 100 kW-class testing while maintaining flexibility for non-heated and heated shakedown, control development, and future integration of advanced TES test sections. In parallel with facility development, a system-level thermal-hydraulic model was created using Modelica-based tools to support component sizing, anticipate performance over targeted test conditions, and establish a framework for future model calibration against experimental data. At the conclusion of the project performance period, the facility was in final assembly, and the pressure boundary was nearly completed. However, several practical challenges associated with high-pressure/high-temperature systems and specialized component procurement impacted schedule and prevented initial pump-driven operation and full commissioning within the available resources. This report documents the as-built design, operating capabilities, and instrumentation, and it summarizes key lessons learned related to heater fabrication and testing, first-of-a-kind assembly factors, specialty flange supply constraints, and fill pump corrective actions. Finally, it outlines a phased plan for future commissioning and experimental campaigns, including control and instrumentation shakedown, heater characterization, model calibration, and testing at state points representative of EarthEn’s TES cycle.

25 ENERGY STORAGE

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING

Convective heat transfer enhancement through additively built multiscale micro-tetrahedron features

Use of Additive Manufacturing (AM) to improve the heat transfer characteristics of tip shrouds in high-pressure turbines is being considered by industries. Existing designs of these components integrate micro-cooling channels to reduce the bulk temperature for improved life. In this research, closely packed micro tetrahedron features in addition to AM roughness has been considered. Further, this multiscale surface characteristics increased surface area per unit volume available for heat exchange. Micro-tet features were designed, manufactured, characterized, and evaluated systematically while increasing their height. An enormous increase in the overall wetted surface area by 200 % was measured. The convective heat transfer enhancement was ~3.72 times EDM rough coupon, and friction factor enhancement was ~5.5 times EDM rough coupon. Furthermore, the proposed design offers 2.5 times enhanced heat transfer for a given 2 W pumping power compared to our EDM rough coupon. Heat transfer enhancement was observed to not vary strongly with increased Reynolds number. Such complex designs are only possible through additive manufacturing for increased heat transfer with little pressure penalty. Finally, increasing the micro-tet height for increased surface area and improved heat exchange beyond an upper limit might not be a significant benefit as it gets compensated by increasing skin friction.

42 ENGINEERING

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE

Approximation of refrigerant thermophysical properties using neural networks to speed up transient thermofluid simulations

Accurate and efficient evaluations of refrigerant thermophysical properties and their partial derivatives are essential for transient simulations of thermofluid systems, where several computations need to be executed at each integration time step. Since the utilization of an Equation of State for retrieving properties based on a pair of independent inputs typically involves numerical iterations in solution procedures, when the input variables differ from the refrigerant state variables employed in dynamic models, a variety of approaches including lookup table interpolation and curve fitting have been developed to explicitly approximate these properties based on the state variables, and consequently eliminate internal iterations. This paper presents an alternative method that exploits derivative-informed neural networks to model refrigerant properties explicitly from inputs of pressure and enthalpy, while ensuring consistent partial derivatives generated by differentiating the neural networks. Computational speed and accuracy of the proposed approach are demonstrated via transient simulations of a discretized heat exchanger model in Modelica, and comparisons against other property evaluation routines. Simulation results indicate that the proposed approach can realize a significant speedup with negligible discrepancies in predicted transients. The method is implemented in an open-source Modelica library.

Ma, Jiacheng

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump

Multiscale characterization of phase change materials for building thermal energy storage applications

Phase change materials (PCMs) store and release large amounts of thermal energy because of their high latent energy storage capacity. However, long-term cyclic stability, supercooling and performance-scalability are some of the major challenges for their use in building thermal energy storage (TES) applications. Here, in this study, we present a comprehensive multiscale characterization of two commercially available organic PCMs, Puretemp 18 and Puretemp 23. At the microscale, differential scanning calorimetry (DSC) was used to characterize phase change temperature, specific heat, and latent heat. At the mesoscale, a heat flow meter apparatus (HFMA), following the ASTM C1784 standard, was employed to measure the phase change temperature, specific heat, and latent heat properties. A comparative analysis of latent heat as a function of temperature was conducted by integrating the DSC and HFMA results. At the macroscale, the thermal performance and cyclic stability of the TES system was evaluated using Puretemp 23. The TES system consisted of a finned tube heat exchanger with a storage volume of 0.0189 m 3 (5 gal), which represents a compact, real-world TES solution suitable for building energy storage. The results showed consistent thermal stability of the PCM over 200 cycles, and the supercooling temperature remained within 0.2 °C, which was not detected in smaller-scale characterization methods. Additionally, the macroscale testing methodology of the PCM revealed that the TES is able to charge and discharge stored latent energy within 2 h under a temperature differential of 16.67 °C measured between the inlet water temperature and the phase transition temperature of the PCM. The proposed multiscale PCM characterization method provides a systematic basis for comparing important thermal storage properties while also investigating the scalability, reliability and integration challenges in large scale TES applications.

Latent heat