Engineering PapersSearch

SEARCH · Engineering Papers

Results for “General procedures and instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Orion Crew Module Landing System Simulation and Verification

NASA Langley Research Center (LaRC) has developed a comprehensive test and analysis program to evaluate the ability of LS-DYNA to model the materials and the phenomena involved in soil and water landing impacts of the Orion crew module. Elemental, scale boilerplate, and full-scale prototype testing is being conducted in support of the simulation verification and validation approach. Aspects of the simulations evaluated against test data include soil constitutive properties, water equations of state, and contact algorithms. Subsystems tested include airbags, crushable energy absorbing honeycomb materials, and energy absorbing seat support struts. The procedures, instrumentation, and general observations from each test series are presented. Plans for a series of swing tests of a full-scale boilerplate into a purpose-built water basin are described. Further plans for swing tests of flight-like prototypes into the water basin are noted.

Vassilakos, Gregory J.

Measuring Thermodynamic Properties of Metals and Alloys With Knudsen Effusion Mass Spectrometry

This report reviews Knudsen effusion mass spectrometry (KEMS) as it relates to thermodynamic measurements of metals and alloys. First, general aspects are reviewed, with emphasis on the Knudsen-cell vapor source and molecular beam formation, and mass spectrometry issues germane to this type of instrument are discussed briefly. The relationship between the vapor pressure inside the effusion cell and the measured ion intensity is the key to KEMS and is derived in detail. Then common methods used to determine thermodynamic quantities with KEMS are discussed. Enthalpies of vaporization, the fundamental measurement, are determined from the variation of relative partial pressure with temperature using the second-law method or by calculating a free energy of formation and subtracting the entropy contribution using the third-law method. For single-cell KEMS instruments, measurements can be used to determine the partial Gibbs free energy if the sensitivity factor remains constant over multiple experiments. The ion-current ratio method and dimer-monomer method are also viable in some systems. For a multiple-cell KEMS instrument, activities are obtained by direct comparison with a suitable component reference state or a secondary standard. Internal checks for correct instrument operation and general procedural guidelines also are discussed. Finally, general comments are made about future directions in measuring alloy thermodynamics with KEMS.

Copland, Evan H.

Bayesian Statistical Models for Community Annoyance Survey Data

This paper demonstrates the use of two Bayesian statistical models to analyze single-event sonic boom exposure and human annoyance data from community response surveys. Each model is fit to data from a NASA pilot study.Unlike many community noise surveys, this study used a panel sample to collect multiple observations per participant instead of a single observation. Thus, a multilevel (also known as hierarchical or mixed-effects) model is used to account for the within-subject correlation in the panel sample data. This paper describes a multilevel logistic regression model and a multilevel ordinal regression model. The paper also proposes a method for calculating a summary dose-response curve from the multilevel models that represents the population. The two models’ summary dose-response curves are visually similar. However, their estimates differ when calculating the noise dose at a fixed percent highly annoyed.

Musical instruments

Full-scale crash test of a CH-47C helicopter

A full-scale crash test of a large troop/cargo carrying CH-47C helicopter was conducted at the Langley impact dynamics research facility. The crash test of this large helicopter was performed as part of a joint U.S. Army-NASA helicopter test program to provide dynamic structural and seat response data. The test, the procedures employed, the instrumentation, a general assessment of the resulting damage, and typical levels of accelerations experienced during the crash are reported. Various energy-absorbing seating systems for crew and troops were installed and instrumented to provide data for use in the development of design criteria for future aircraft. The crash conditions were selected to simulate known crash conditions and are representative of the 95th percentile accident environment for an autorotating helicopter. Visual examination of the crashed test specimen indicated irreparable damage to many of the structural components. The highest accelerations were recorded by the accelerometers located on the cabin floor in the aft section of the helicopter, directly above the primary impact location and on the floor of the cockpit above the secondary impact location(s).

Castle, C. B.

Analytical procedure for evaluating speckle-effect instrumentation

A general analysis suitable for developing speckle effect instruments and a simplified analysis suitable for evaluating laser speckle instrumentation are presented. The simplified analysis is summarized as a list of equations. Several sample applications are discussed.

Decker, A. J.

The M68HC11 gripper controller electronics

This document describes the instrumentation, operational theory, circuit implementation, calibration procedures, and general notes for the CIRSSE general purpose pneumatic hand. The mechanical design and the control software are discussed. The circuit design, PCB layout, hand instrumentation, and controller construction described in detail in this document are the result of a senior project.

Kelley, Robert B.

Flight Experiment Investigation of General Aviation Self-Separation and Sequencing Tasks

A new flight operations concept called Small Aircraft Transportation System (SATS) Higher Volume Operations (HVO) was developed to increase capacity during Instrument Meteorological Conditions (IMC) at non-towered, non-radar airports by enabling concurrent operations of multiple aircraft. One aspect of this concept involves having pilots safely self-separate from other aircraft during approaches into these airports using appropriate SATS HVO procedures. A flight experiment was conducted to determine if instrument-rated general aviation (GA) pilots could self-separate and sequence their ownship aircraft, while following a simulated aircraft, into a non-towered, non-radar airport during simulated IMC. Six GA pilots' workload levels and abilities to perform self-separation and sequencing procedures while flying a global positioning system (GPS) instrument approach procedure were examined. The results showed that the evaluation pilots maintained at least the minimum specified separation between their ownship aircraft and simulated traffic and maintained their assigned landing sequence 100-percent of the time. Neither flight path deviations nor subjective workload assessments were negatively impacted by the additional tasks of self-separating and sequencing during these instrument approaches.

Murdoch, Jennifer L.

Alignment of Optical Backscatter Measurements from the EXPORTS Northeast Pacific Field Deployment

Backscattering of light is commonly measured by ocean observing systems, including ships and autonomous platforms, and is used as a proxy for the concentration of water column constituents such as phytoplankton and particulate carbon. Multiple on-going projects involve large numbers of independent measurements of backscatter, as well as other biologically relevant parameters, to understand how biology is changing in time and space throughout the global ocean. Rarely are there sufficient measurements to test how well these instruments are inter-calibrated in real-world deployment conditions. This paper develops a procedure to align multiple independently calibrated backscatter instruments to each other using nearby profiling casts and applies this method to nine instruments deployed during a recent field campaign in the North Pacific during August–September of 2018. This process revealed several incorrect calibrations; post-alignment, all nine instruments aligned extremely well with each other. We also tested an alignment to a deep-water reference and found that this method is generally sufficient but has significant limitations; this procedure lacks the ability to correct instruments measuring only shallow profiles and can only account for additive offsets, not multiplicative changes. These findings highlight the utility of process studies involving several independent measurements of similar parameters in the same area.

North Pacific

Instrumentation for one-way satellite PTTI applications

A review of general principles and operational procedures illustrates how the typical passive user and omni receiving antenna can recover Precise Time and Time Interval (PTTI) information from a low altitude navigation satellite system for clock calibration and synchronization. Detailed discussions of concepts and theory of the receiver design are presented. The importance of RF correlation of the received and local PN encoded sequences is emphasized as a means of reducing delay uncertainties of the instrumentation to values compatible with nanosecond to submicrosecond PTTI objectives. Two receiver configurations were fabricated for use in satellite-to-laboratory experiments. In one receiver the delay-locked loop for PN signals synchronization used a dithered amplitude detection process while the second receiver used a complex sums phase detection method for measurement of delay error. The necessity for compensation of Doppler shift is discussed. Differences in theoretical signal acquisition and tracking performance of the design concepts are noted.

Osborne, A. E.

Development and evaluation of a prototype in-flight instrument flight rules (IFR) procedures trainer

An in-flight instrument flight rules (IFR) procedures trainer capable of providing simulated indications of instrument flight in a typical general aviation aircraft independent of ground based navigation aids was developed. The IFR navaid related instruments and circuits from an ATC 610J table top simulator were installed in a Cessna 172 aircraft and connected to its electrical power and pitot static systems. The benefits expected from this hybridization concept include increased safety by reducing the number of general aviation aircraft conducting IFR training flights in congested terminal areas, and reduced fuel use and instruction costs by lessening the need to fly to and from navaid equipped airports and by increased efficiency of the required in-flight training. Technical feasibility was demonstrated and the operational feasibility of the concept was evaluated. Results indicated that the in-flight simulator is an effective training device for teaching IFR procedural skills.

Aaron, J. B., Jr.

Physics-based Tests to Identify the Accuracy of Solar Wind Ion Measurements: A Case Study with the Wind Faraday Cups

We present techniques for comparing measurements of velocity, temperature, and density with constraints imposed by the plasma physics of magnetized bi-Maxwellian ions. Deviations from these physics-based constraints are interpreted as arising from measurement errors. Two million ion spectra from the Solar Wind Experiment Faraday Cup instruments on the Wind spacecraft are used as a case study. The accuracy of velocity measurements is determined by the fact that differential flow between hydrogen and helium should be aligned with the ambient magnetic field. Modeling the breakdown of field alignment suggests velocity uncertainties are less than 0.16% in magnitude and 3deg in direction. Temperature uncertainty is found by examining the distribution of observed temperature anisotropies in high-beta solar wind intervals where the firehose, mirror, and cyclotron microinstabilities should drive the distribution to isotropy. The presence of a finite anisotropy at high beta suggests overall temperature uncertainties of 8%. Hydrogen and helium number densities are compared with the electron density inferred from observations of the local electron plasma frequency as a function of solar wind speed and year. We find that after accounting for the contribution of minor ions, the results are consistent with a systematic offset between the two instruments of 34%. The temperature and density methods are sensitive to non-Maxwellian features such as heat flux and proton beams and as a result are more suited to slow solar wind where these features are rare. These procedures are of general use in identifying the accuracy of observations from any solar wind ion instrument.

Kasper, J. C.

Applications of luminescent systems to infectious disease methodology

The characterization of a clinical sample by a simple, fast, accurate, automatable analytical measurement is important in the management of infectious disease. Luminescence assays offer methods rich with options for these measurements. The instrumentation is common to each assay, and the investment is reasonable. Three general procedures were developed to varying degrees of completeness which measure bacterial levels by measuring their ATP, FMN and iron porphyrins. Bacteriuria detection and antibiograms can be determined within half a day. The characterization of the sample for its soluble ATP, FMN or prophyrins was also performed.

Picciolo, G. L.

Acoustic Measurements for Small Solid Rocket Motors

Models have been developed to predict large solid rocket motor acoustic loads based on the scaling of small solid rocket motors. MSFC has measured several small solid rocket motors in horizontal and launch configurations to anchor these models. Solid Rocket Test Motor (SRTM) has ballistics similar to the Reusable Solid Rocket Motor (RSRM) therefore a good choice for acoustic scaling. Acoustic measurements were collected during the test firing of the Insulation Configuration Extended Length (ICXL) 7,6, and 8 (in firing order) in order to compare to RSRM horizontal firing data. The scope of this presentation includes: Acoustic test procedures and instrumentation implemented during the three SRTM firings and Data analysis method and general trends observed in the data.

Vargas, Magda B.

General Aviation Flight Test of Advanced Operations Enabled by Synthetic Vision

A flight test was performed to compare the use of three advanced primary flight and navigation display concepts to a baseline, round-dial concept to assess the potential for advanced operations. The displays were evaluated during visual and instrument approach procedures including an advanced instrument approach resembling a visual airport traffic pattern. Nineteen pilots from three pilot groups, reflecting the diverse piloting skills of the General Aviation pilot population, served as evaluation subjects. The experiment had two thrusts: 1) an examination of the capabilities of low-time (i.e., <400 hours), non-instrument-rated pilots to perform nominal instrument approaches, and 2) an exploration of potential advanced Visual Meteorological Conditions (VMC)-like approaches in Instrument Meteorological Conditions (IMC). Within this context, advanced display concepts are considered to include integrated navigation and primary flight displays with either aircraft attitude flight directors or Highway In The Sky (HITS) guidance with and without a synthetic depiction of the external visuals (i.e., synthetic vision). Relative to the first thrust, the results indicate that using an advanced display concept, as tested herein, low-time, non-instrument-rated pilots can exhibit flight-technical performance, subjective workload and situation awareness ratings as good as or better than high-time Instrument Flight Rules (IFR)-rated pilots using Baseline Round Dials for a nominal IMC approach. For the second thrust, the results indicate advanced VMC-like approaches are feasible in IMC, for all pilot groups tested for only the Synthetic Vision System (SVS) advanced display concept.

Glaab, Louis J.

Description and calibration of the Langley Hypersonic CF4 tunnel: A facility for simulating low gamma flow as occurs for a real gas

The Langley Hypersonic CF4 Tunnel is a Mach 6 facility which simulates an important aspect of dissociative real-gas phenomena associated with the reentry of blunt vehicles, i.e., the decrease in the ratio of specific heats (gamma) that occurs within the shock layer of the vehicle. A general description of this facility is presented along with a discussion of the basic components, instrumentation, and operating procedure. Pitot-pressure surveys were made at the nozzle exit and downstream of the exit for reservoir temperatures from 1020 to 1495 R and reservoir pressures from 1000 to 2550 psia. A uniform test core having a diameter of circa 11 in. (0.55 times the nozzle-exit diameter) exists at the maximum value of reservoir pressure and temperature. The corresponding free-stream Mach number is 5.9, the unit Reynolds number is 4 x 10 to the 5th power per foot, the ratio of specific heats immediately behind a normal shock is 1.10, and the normal-shock density ratio is 12.6. When the facility is operated at reservoir temperatures below 1440 R, irregularities occur in the pitot-pressure profile within a small region about the nozzle centerline. These variations in pitot pressure indicate the existence of flow distrubances originating in the upstream region of the nozzle. This necessitates testing models off centerline in the uniform flow between the centerline region and either the nozzle boundary layer or the lip shock originating at the nozzle exit. Samples of data obtained in this facility with various models are presented to illustrate the effect of gamma on flow conditions about the model and the importance of knowing the magnitude of this effect.

Midden, Raymond E.

Analysis of instrumentation error effects on the identification accuracy of aircraft parameters

An analytical investigation is presented of the effect of unmodeled measurement system errors on the accuracy of aircraft stability and control derivatives identified from flight test data. Such error sources include biases, scale factor errors, instrument position errors, misalignments, and instrument dynamics. Two techniques (ensemble analysis and simulated data analysis) are formulated to determine the quantitative variations to the identified parameters resulting from the unmodeled instrumentation errors. The parameter accuracy that would result from flight tests of the F-4C aircraft with typical quality instrumentation is determined using these techniques. It is shown that unmodeled instrument errors can greatly increase the uncertainty in the value of the identified parameters. General recommendations are made of procedures to be followed to insure that the measurement system associated with identifying stability and control derivatives from flight test provides sufficient accuracy.

Sorensen, J. A.

Solar maximum observatory repair mission

A description of the Solar Maximum Observatory and the operational status of its instrument systems is presented. The major science objectives which could be made possible with repairs to the spacecraft are defined. Hardware requirements and procedures for a repair mission are detailed. In general the mission involves: (1) the capture and control of the observatory in free flight by an astronaut in the manned manipulator unit; (2) berthing the observatory to the orbiter with the remote manipulator system; and (3) repairing the scientific instruments and replacing the attitude control system through extravehicular activity.

Kenney, G. P.