Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLOW DISCHARGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of Cathode Cooling in Three-Dimensional Simulations of an Atmospheric Pressure Glow Discharge

The Atmospheric Pressure Glow Discharge (APGD) is a relatively simple and versatile plasma source used in a wide range of applications. Active cooling of the cathode can effectively mitigate instabilities, leading to glow-to-arc transitions. This study investigates the effect of varying the degree of cathode cooling in APGD with a planar cathode in helium. The plasma flow model incorporates mass conservation, chemical species transport, momentum conservation, conservation of thermal energy of heavy species and of electrons, and electrostatics. The model is applied to time-dependent simulations through a three-dimensional computational domain describing the whole discharge, without geometric symmetry or steady-state assumptions. Simulations of an experimentally characterized APGD explore the effects of electric current and cathode cooling—ranging from thermally insulated to extreme convective cooling. Results show the formation of an annular region with high electric field over the cathode surface under conditions of high current and low cooling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Glow Discharge Boronization and Real-Time Boronization Using an Impurity Powder Dropper in LHD

In the Large Helical Device (LHD), boronization is utilized for wall conditioning, employing two distinct methods: glow discharge using diborane gas and the injection of boron powder into the plasma via an impurity powder dropper (IPD). Glow discharge boronization is conducted after maintenance when the vacuum vessel is exposed to air and just before the start of an experimental campaign. In contrast, real-time boronization using the IPD is performed during discharges. The distribution of boron on plasma-facing components was assessed through long-term material probes in the case of glow discharge and through numerical simulations for the IPD method. Results indicated non-uniform boron distributions in both cases. The impact of these boronization techniques on impurity levels and the lifetime of their effects were also examined. Both methods effectively reduced oxygen and iron in the plasma, with the iron impurities originating from the first wall. For glow discharge boronization, the reduction in oxygen levels persisted until the end of the experimental campaign, whereas the reduction in iron levels only lasted a few days. In the case of boron injection during long pulse discharges exceeding 200 s, the suppression of oxygen and iron was observed. The effect on iron quickly diminished within several seconds after the injection ended, whereas the effect on oxygen lasted more than 100 s. The difference in the lifetimes of the boronization effects is further discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid-to-gas transfer of sodium in a liquid anode glow discharge

Solute transfer from the liquid to the gas phase in plasmas has been widely used in analytical chemistry often focused on liquid cathode discharges. In this study, we report on time-resolved absolute density measurements of sodium in a glow discharge plasma with a NaCl solution anode using two-photon absorption laser induced fluorescence. The averaged maximum sodium density is found to be similar to the electron density in the discharge consistent with plasma-induced vapor generation. Random sodium flashes were also observed extending into the plasma afterglow and are attributed to sodium particles falling back on the liquid surface. Cataphoresis can explain the location of the maximum sodium density near the cathode side of the electrode gap rather than near the liquid anode region.

chemical vapor generation↗

Surface deformation coupled with self-organized pattern on a liquid anode of 1 atm DC glow discharge

Intricate, self-organized plasma structures observed above the surface of a liquid anode of atmospheric DC glow discharge were found to give rise to coherent, organized surface deformation and mechanical wave formation at the plasma–liquid interface. This new phenomenon indicates that the liquid is closely coupled to the plasma by the anode sheath’s electrohydrodynamic (EHD) force. A scientific question then arises: Do surface perturbations, coupled with the nonuniform surface charge distribution, enhance the electric field and induce self-organization? Using the reflective background-oriented schlieren technique, the liquid surface profile under the plasma pattern was measured for the first time. The results show that surface distortions are driven by the repulsive Coulomb force of nonuniform net-negative surface charge acted by the anode sheath field. The impacts of various operating parameters on the patterns and surface waves were examined, revealing the significance of gas heating and liquid charge relaxation time in the pattern formation mechanism. Time-resolved dynamics of a pulsed DC discharge indicated that the surface deformation only appeared after the establishment of plasma patterns. Statistically, the surface wave under the plasma has high wave numbers (8000–16000 m −1 ) and small amplitudes ($<$ 10 µm), generally found in the capillary wave regime. Yet the motion of surface deformations is in tandem with the plasma pattern and exhibits a nondispersive nature of constant phase velocity (0.1–0.4 m s −1 ), suggesting the dominant role of EHD force over the surface tension in the observed surface wave. These results indicate that the deformed liquid surface is driven by the EHD force of the plasma sheath. Although they share a similar geometry, the deformation and wave dynamics of the liquid surface do not stimulate a plasma pattern. Importantly, the complex EHD coupling in the plasma–liquid system raises awareness and new challenges for plasma control engineering, and the quantitative characteristics of the nondispersive surface wave are informative for advancing relevant theory and modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing of spark plasma sintered porous tungsten under neon glow discharge cleaning conditions in LTX-β

This paper demonstrates that tungsten (W) based powder reconstituted Plasma Facing Components (PFCs) can be treated in situ in a fusion reactor to remove W oxide and carbon (C) contamination. Doing so should ease the challenge of using these materials in a Capillary Porous System (CPS) with lithium (Li) by enabling better wetting and less contamination of the Li by the underlying CPS. Most powder reconstituted materials including 3D printed and sintered PFCs suffer from a high surface contamination from oxides and surface C, which complicates their use with liquid Li, a primary PFC candidate. Spark plasma sintered porous W samples were fabricated to be used as a CPS with liquid Li. The samples were characterized in terms of morphology and surface chemistry. Analysis confirms a high C and oxygen (O) contamination. We present the results of exposing this type of CPS to Glow Discharge Cleaning (GDC) cycles in the Lithium Tokamak Experiment-β (LTX-β). The sample was exposed to neon (Ne) GDC in the midplane of the low-field side of LTX-β and analyzed in vacuo with Temperature Programmed Desorption (TPD) and Secondary Ion Mass Spectrometry (SIMS) to investigate the effects the Ne GDC had on the chemical composition of the sample. The combination of Ne GDC with rapid heating as done in TPD was successful in reducing the W oxides and removing the C contamination.

Capillary porous system↗

Quantifying the thermal effect and methyl radical production in nanosecond repetitively pulsed glow discharges applied to a methane-air flame

In this work, we investigated non-equilibrium plasma produced by nanosecond repetitively pulsed glow discharges applied across a lean premixed methane-air flame. The flame is stationary, axisymmetric, and laminar. The discharges are applied on the symmetry axis crossing the reactant gases, flame front, and product gases, allowing phase-locked averaged measurements and comparisons with axisymmetric numerical simulations. The thermal effect and methyl radical production are quantified in the discharge in the reactant gas region. One-dimensional, two-beam, hybrid, femtosecond-picosecond, coherent anti-Stokes Raman scattering is used to acquire spatial and temporal profiles of temperature and oxygen-to-nitrogen concentration ratio. Photo-fragmentation laser-induced fluorescence is used to acquire quantitative two-dimensional profiles of methyl radicals in the discharge providing the first quantitative imaging of methyl produced ahead of a flame by plasma-induced methane dissociation. The spatial profiles of temperature and oxygen-to-nitrogen concentration ratio are in steady state, indicating that individual discharges have an insignificant heating effect. Upper and lower bounds of the produced mole fraction of methyl radicals in the plasma are obtained due to uncertainties in the collisional quenching rates of excited state methylidyne radicals in the plasma. The discharges produce a maximum of 600–1100 ppm of methyl radicals upstream of the flame front within 25 ns. This amount is similar to the predicted methyl mole fraction for the flame without plasma and thus represents a significant chemical perturbation to the reactants upstream of the flame front. The produced methyl follows an exponential decay in the first microsecond after the discharge with a decay constant of 8 µs close to the flame, and 0.8 µs further from the flame. The decay then deviates from the exponential curve and the methyl persists for tens of microseconds. The results suggest that for the tested configuration, the thermal effect of individual discharges through fast gas heating is negligible, while active chemical species are produced in large quantities in the reactant gases, upstream of the flame front.

hybrid fs-ps CARS↗

Pulsed contact glow discharge electrification for online material quantification

Real-time elemental analysis of liquids in extreme environments remains a significant challenge for sensor development, particularly in applications such as advanced nuclear reactors. Plasma-based optical emission spectroscopy offers a promising solution. In this study, we investigate pulsed contact glow discharge electrolysis (CGDE) as an alternative plasma generation method for emission-based material quantification. Using aqueous NaCl solutions, we examine the role of discharge polarity on plasma behavior, emission characteristics, and spectral output. Our results demonstrate that cathodic discharges generate more energetic plasmas, enabling the detection of ionic species such as cerium, while anodic discharges favor atomic emission. These findings reveal a potential dual-mode sensing capability controlled by circuit configuration rather than hardware changes. Through synchronized measurements of emission, current, bubble, and spectral dynamics, we present a model in which electron emission and ohmic heating drive plasma formation. This model enhances our understanding of pulsed-CGDE and supports its potential as a versatile, adaptable platform for future deployment in high-temperature liquids such as molten salts.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid-to-gas transfer of sodium in a liquid cathode glow discharge

Abstract Plasma-liquid interactions have been extensively studied with a focus on the transport of reactive species from the plasma to the liquid phase and their induced liquid phase chemistry and resulting applications. While solute transfer from the liquid to the gas phase in plasmas has been widely used in analytical chemistry, the underlying processes remain relatively unexplored. We report spatially and temporally resolved absolute density measurements of sodium in a plasma with a NaCl solution cathode using two-photon absorption laser induced fluorescence (TaLIF). The observed non-linear increase in sodium density with solution conductivity is shown to correlate with droplet generation as visualized by Mie scattering. The findings are explained by droplet generation by electrospray induced by Taylor cone formation as underpinning mechanism for the introduction of sodium in the plasma. An analytical sheath model combined with a scaling law shows an increase in electric field force with solution conductivity that is consistent with the observed non-linear increase in sodium density in the plasma with solution conductivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of a transparent water-cooled cathode on the neutron production rate in the glow discharge-type fusion neutron source

In glow discharge-type deuterium–deuterium fusion neutron sources, fusion reactions occurring on the cathode surface contribute significantly to the neutron production rate (NPR); therefore, cathode design plays a crucial role in enhancing NPR. Although the NPR generally increases with discharge current, deuterium desorption caused by cathode heating tends to stagnate it in the high-current regime. Water cooling has been shown to mitigate this stagnation for nontransparent cathodes, but its effectiveness for transparent cathodes has not been experimentally clarified. Here, in this study, a transparent cathode with active water cooling and a spherical geometry was designed and fabricated using stainless steel tubing. Neutron production experiments were conducted with and without water cooling: with water cooling, applied voltages of 20–40 kV were investigated, while without water cooling, the applied voltage was limited to 25 kV. The results showed that the NPR increased continuously with discharge current without stagnation when water cooling was applied. A maximum NPR of (1.8 ± 0.02) × 10 6 n/s was achieved at 40 kV and 50 mA. Compared with our previously reported disk cathode and nontransparent water-cooled cathode of the same diameter, the transparent water-cooled cathode exhibited a significantly enhanced NPR. These findings indicate that combining cathode transparency with active cooling is an effective strategy for improving neutron production in glow discharge-type fusion neutron sources.

43 PARTICLE ACCELERATORS↗

Enhancing nitrogen fixation efficiency in glow-like discharge by reducing cathode-fall voltage

In plasma nitrogen fixation devices, discharge electrodes are crucial yet susceptible to oxidation and corrosion due to plasma’s high temperatures and oxygen content, which could alter discharge modes. This research evaluates the impact of different electrode materials, including iron, chromium, nickel, copper, and 304 stainless steel, on nitrogen fixation efficiency in glow-like discharges driven by high-voltage DC power. Notably, iron and 304 stainless steel cathodes undergo a mode transition at increased currents, evident from plasma color shifts and significant voltage reductions. Fourier transform infrared spectroscopy analyses reveal that such mode changes minimally affect nitrogen oxide production rates, leading to a notable decrease in energy consumption for nitrogen fixation by up to 40%. OES and SEM-EDS measurements suggest that iron oxide, with its higher secondary electron emission, replaces metal as the cathode material, facilitating mode transitions and maintaining discharge current at lower voltages. Further, this voltage change is largely attributed to the cathode voltage drop, highlighting the minimal role of the cathode fall region in NO x synthesis. These findings underscore the potential for improving plasma nitrogen fixation energy efficiency by choosing suitable cathode materials to lower the cathode-fall voltage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing the impact of oxygen negative ions on the self-organized pattern in 1 atm DC glow with liquid anode

In an atmospheric DC glow discharge with a liquid anode, the plasma anode glow attached to the grounded liquid surface under certain conditions self-organizes into coherent patterns. Optical emission spectroscopy revealed that the emission consists primarily of the second positive system of nitrogen, N 2 (C-B), whose excitation energy is low and sensitive to changes in the electron energy distribution. In addition to electrons, negative ions can accumulate in the anode sheath and affect the local space charge. It has been speculated that these negative ions play a role in pattern formation at the anode surface. In this work, the role of oxygen negative ions was explored. It was found that the formation of anode patterns requires at least a 7% volume fraction of oxygen in the ambient gas. Results showed that O 2 - is the dominant negative ion species in atmospheric DC glow discharge, with a density of ~10 12 cm -3 . While the presence of oxygen appears to be crucial for pattern formation, this study indicated that patterns still formed without geometric changes even when 62% of negative ions in the plasma were detached by a laser. This suggests that negative ions do not support the patterns, while oxygen's heating effect may induce instability at the anode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hysteresis between gas breakdown and plasma discharge

In direct-current (DC) discharge, it is well known that hysteresis is observed between the Townsend (gas breakdown) and glow regimes. Forward and backward voltage sweep is performed using a one-dimensional particle-in-cell Monte Carlo collision (PIC-MCC) model considering a ballast resistor. When increasing the applied voltage after reaching the breakdown voltage (V b ), transition from Townsend to glow discharges is observed. When decreasing the applied voltage from the glow regime, the discharge voltage (V d ) between the anode–cathode gap can be smaller than the breakdown voltage, resulting in a hysteresis, which is consistent with experimental observations. Next, the PIC-MCC model is used to investigate the self-sustaining voltage (V s ) in the presence of finite initial plasma densities between the anode and cathode gap. It is observed that the self-sustaining voltage coincides with the discharge voltage obtained from the backward voltage sweep. In addition, the self-sustaining voltage decreases with increased initial plasma density and saturates above a certain initial plasma density, which indicates a change in plasma resistivity. The decrease in self-sustaining voltage is associated with the electron heat loss at the anode for the low pd (rarefied) regime. In the high pd (collisional) regime, the ion energy loss toward the cathode due to the cathode fall and the inelastic collision loss of electrons in the bulk discharge balance out. Finally, it is demonstrated that the self-sustaining voltage collapses to a singular value, despite the presence of a initial plasma, for microgaps when field emission is dominant, which is also consistent with experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Liquids Using the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER)

We developed a sensor called the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER) probe, which uses an atmospheric pressure glow discharge below the surface of liquids to excite species in the liquid. Through emission spectroscopy of molten salts, liquid metals, and heavy water, we demonstrated the SPIDER probe’s high resolution, accuracy, and versatility. We successfully identified trace concentrations of transition and rare-earth metals in molten salts and detected the isotopic shift of the H β → D β emission line. Our analysis revealed unconventional spectral alkali line shapes, indicating two competing excitation modes: film explosion and droplet vaporization. The film explosion mode, characterized by dense plasma, exhibited self-reversal and broadband continuum emission, while the droplet vaporization mode, associated with diffusive plasma, produced narrow-line emissions. Furthermore, by analyzing circuit transients alongside individual plasma events, we observed that film explosions generate higher currents, likely due to a shorter plasma length as the current preferentially flows through the thin liquid layer. Altogether, our results highlight the SPIDER probe’s efficacy and flexibility, making it well-suited for online material quantification of liquids in extreme environments.

AES↗