Temperature-controlled fluidic device A concept

Symmetrical fluidic device directly converts electrical signals to mechanical signals in the form of a fluid-flow parameter. This device eliminates or reduces effects of all undesirable parameters on the departure angle, leaving it a function of the controlled wall and jet temperatures.

Rehsteiner, F. H.↗

A fluidic device for measuring constituent masses of a flowing binary gas mixture

A continuous reading mass flow device was developed to measure the component flow of a binary gas mixture. The basic components of the device are a fluidic humidity sensor and a specially designed flow calorimeter. These components provide readings of gas mixture ratio, mixture heat capacity, heat dissipated by the calorimeter and the gas temperature rise across the calorimeter. These parameter values, applied in the general definitions of specific heat capacity and the heat capacity of a gas mixture, produce calculated component flow rates of the mixture being metered. A test program was conducted to evaluate both the steady state and dynamic performance of the device.

Prokopius, P. R.↗

Fluidic device for measuring constituent masses of a flowing binary gas mixture

Device consists of fluidic humidity sensor and specially designed flow calorimeter. Calorimeter provides readings of gas stream temperature rise produced by measured amount of heat that is dissipated into gas stream, and humidity sensor is used to obtain continuous calculation of specific heat capacity of gas mixture.

Prokopius, P. R.↗

Micro-Fluidic Device for Drug Delivery

A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

Beebe, David J.↗

Automated Fluidics Device for Extraction and Quantification of miRNA Biomarkers From Blood

Radiation Assessment DuRing Exposure And long-Duration Spaceflight (RADREADS) demonstrates space-compatible point-of-care technology for quantitative biological monitoring of blood miRNA biomarkers in response to long-term low dose radiation exposure. This individualized monitoring approach will inform targeted treatment strategies to maximize medical resource utilization by accounting for individual susceptibility to radiation-related illnesses. As human spaceflight progresses beyond Earth’s magnetic shielding, radiation exposure poses a significant risk to astronaut health and safety. Extended operation in this environment comes with an increased risk of radiation exposure, leading to higher risks of radiation sickness, cancer, central nervous system effects, and degenerative diseases. While conventional physical dosimetry techniques capture radiation dose, individualistic susceptibility to radiation damage is varied. Multiple characteristics, including age, body weight, sex, genetics, and immune status, have been found to influence radiosensitivity (Liu et al. 2011, and Bouffler 2016). This differential response necessitates individualized monitoring and targeted treatment strategies to maximize medical resource utilization; however, a practical diagnostic platform for quantifying long-term, low dose radiation-induced tissue damage does not currently exist. MicroRNAs (miRNAs) are a class of small, non-coding RNAs that regulate gene expression by mediating the degradation of messenger RNA. The levels of particular miRNAs are influenced by biological processes such as inflammation and serve as biomarkers for a variety of conditions including cancer (Singh et al. 2017). MicroRNAs are found in various bodily fluids and are amenable to collection via liquid biopsies, providing a minimally invasive and easily quantifiable readout for a variety of radiosensitive reporters. A preliminary signature of 15 spaceflight sensitive miRNA has been identified in rodent and human studies, including miR-21-5p, miR-24-3p, miR-92a-3p, miR-17-5p, miR-16a-3p, miR-34a-3p, and miR-223-3p. These targets generally increased expression with radiation dose and linear energy transfer, though variation between individuals is not yet described. Current gaps in the field include a lack of understanding of longitudinal biological responses to long-term, low dose radiation exposure and the absence of space-compatible point-of-care technology for quantitative biological monitoring. In this body of work, we aim to develop an automated bleed-to-read system to process whole blood for the detection of miRNA biomarkers in order to monitor individualistic responses to radiation exposure. This will be achieved via separating serum (or plasma) from whole blood, followed by extraction, amplification, and quantification of the miRNA using a RT-qPCR reaction. Previously, the WetLab-2 hardware enabled execution of a RT-qPCR reaction aboard ISS; however, it is a manual system that requires crew manipulation and bulky components (Parra et al. 2017). To address these issues, automated fluid handling hardware was developed for each stage of sample preparation. Extraction of total RNA is achieved by sequentially pumping reagents through an off-the-shelf nucleic acid binding column (miRNeasy Serum/Plasma Advanced Kit, Qiagen). This approach eliminates several manual pipetting and centrifuging steps and limits the use of toxic chemicals commonly found in other sample processing techniques. The resulting elution will then be automatically dispensed for RT-qPCR analysis using a compact rotary qPCR (Mic qPCR Cycler, Bio Molecular Systems) that will improve spaceflight compatibility by removing bubbles from the detection region, another challenge highlighted by WetLab-2 (Parra et al. 2017). Efforts are also being made to simplify the RT-qPCR reaction to a 1-step air-dryable mix to improve long-term reagent stability at room temperature and reduce system complexity. By automating the RT-qPCR processes via microfluidic manipulation, RADREADS will reduce crewmember hands-on time and enable the personalized detection of radiation-induced tissue damage during long duration missions. Minimally invasive, longitudinal monitoring of individual’s response to radiation exposure will inform how the physiological system responds to long-term low dose space radiation and enables development of targeted countermeasures by the medical team. Ultimately, this portable technology will require minimal technical expertise and can also be used to monitor miRNA biomarkers associated with other diseases.

Tristen Head↗

Fluidic-thermochromic display device

Fluidic decoder and display device has low-power requirements for temperature control of thermochromic materials. An electro-to-fluid converter translates incoming electrical signals into pneumatics signal of sufficient power to operate the fluidic logic elements.

Grafstein, D.↗

Application of fluidics to instrumentation in hostile environments

This paper discusses the use of fluidic devices for measurement and control in the presence of hostile environments. Various applications are presented together with possible solutions by the use of fluidics. Several fluidic devices, components and circuits are described which may be adapted to fluidic measurement and control of processes where other methods fail or become extremely difficult or damaging to the instrumentation. Devices and techniques described include a description of a capillary temperature probe including both probe and circuit designs, and several possible techniques which may be used in the design and testing of fluidic devices.

Walsh, J.↗

Simple Check Valves for Microfluidic Devices

A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

Willis, Peter A.↗

Variable Control Port for Fluidic Control Device

Volume and velocity of control flow independently adjustable. In proposed device rotatable D-shaped control sector throttles down control port or open it completely and set to any intermediate control-port crosssectional area. Although adjustment affects volume and control-port head loss, volume and velocity controlled independently by also adjusting fluidsupply pressure. Allows adjustment to wider range of control conditions and ability to maximize control efficiency. Fluidic control theory suggests possibility of improvement in control ratio of at least 2:1 over conventional devices.

Collins, Earl R., Jr.↗

Micro-Scale Regenerative Heat Exchanger

A micro-scale regenerative heat exchanger has been designed, optimized and fabricated for use in a micro-Stirling device. Novel design and fabrication techniques enabled the minimization of axial heat conduction losses and pressure drop, while maximizing thermal regenerative performance. The fabricated prototype is comprised of ten separate assembled layers of alternating metal-dielectric composite. Each layer is offset to minimize conduction losses and maximize heat transfer by boundary layer disruption. A grating pattern of 100 micron square non-contiguous flow passages were formed with a nominal 20 micron wall thickness, and an overall assembled ten-layer thickness of 900 microns. Application of the micro heat exchanger is envisioned in the areas of micro-refrigerators/coolers, micropower devices, and micro-fluidic devices.

Moran, Matthew E.↗

Fabrication of Channels for Nanobiotechnological Devices

A method, now undergoing development, of forming nanochannels in planar substrates is intended to enable the fabrication of advanced fluidic devices that could be integrated with complementary metal oxide semiconductor (CMOS) electronic circuits. Such integral combinations of fluidic and electronic components ("laboratory-on-a-chip" devices) could be used, for example, to detect individual molecules of deoxyribonucleic acid (DNA) and proteins. The width of a channel in such a device would be chosen so that molecules of the species of interest would move along the channel in single file. In this method, the fabrication of channels includes the use of such CMOS-compatible processes as chemical-mechanical polishing and oxide deposition. The layout of the channels in the substrate plane is determined by a single photolithographic process, but it is not a nanoscale lithographic process, and this process is not relied upon to define the thickness and width of the channels. Stating it from a slightly different perspective, unlike in the prior fabrication of electronic and fluidic devices involving the use of lithography to define microscale features, this process does not include the use of lithography to define nanoscale features. It is this aspect of the method that enables simplification of the process and, hence, a decrease in cost.

Lee, Choonsup↗

Fluidic systems may improve combustion in automotive engines

Application of fluidic devices to reduce generation of noxious exhausts from internal combustion engines is discussed. Operation of fluidic system to provide bypass of fuel air mixture into heated loop to provide more complete combustion is explanined. Advantage lies in no moving parts required for fluidic by-pass action.

Mangion, C.↗

Multi-Axis Fluidic Thrust Vectoring of a Supersonic Jet Using Counterflow

The most common techniques currently used to efficiently vector supersonic jets require external flaps and or pivoting devices. Fluidic thrust vectoring using counterflow eliminates the need for such complex hardware. Thus, the promise of decreases in both weight and drag as well as increased maneuverability makes this technique an attractive alternative. This technique has been successfully employed to achieve single axis fluidic thrust vectoring of a Mach 2 rectangular jet. To better compete with contemporary systems the current study extends this technique to multi-axis thrust vectoring of a Mach 2 diamond-shaped jet by applying counterflow to one of its four sides. To evaluate the performance of this technique the Planar Laser Scattering (PLS) technique is used to show the continuous vectoring of the diamond jet up to 20 degrees. Also, cross-stream PLS images are acquired to show the vectoring can be achieved off all four surfaces of the diamond jet.

Barber, Edward L.↗

Low cost fluidic sensors

The gyroscopic inertial sensors used in general aviation autopilots and in stability augmentation systems probably contribute more than any other component to the initial cost and to the continuing maintenance costs of these installations. Several fluidic devices which were developed to replace the gyroscopes in the conventional ""wing-leveler'' type autopilots used in small, general aviation airplanes are described. These sensors are characterized by simplicity of design, ease of fabrication, and lack of wearing parts. A unique, fluidic, true airspeed sensor is also described. All these devices are adapted to fabrication by low cost plastic molding techniques, and their lack of wearing parts promises long, maintenance free service lives.

Garner, H. D.↗

Quality Control Method for a Micro-Nano-Channel Microfabricated Device

A variety of silicon-fabricated devices is used in medical applications such as drug and cell delivery, and DNA and protein separation and analysis. When a fluidic device inlet is connected to a compressed gas reservoir, and the outlet is at a lower pressure, a gas flow occurs through the membrane toward the outside. The method relies on the measurement of the gas pressure over the elapsed time inside the upstream and downstream environments. By knowing the volume of the upstream reservoir, the gas flow rate through the membrane over the pressure drop can be calculated. This quality control method consists of measuring the gas flow through a device and comparing the results with a standard curve, which can be obtained by testing standard devices. Standard devices can be selected through a variety of techniques, both destructive and nondestructive, such as SEM, AFM, and standard particle filtration.

Grattoni, Alessandro↗

Optimization of a fluidic temperature control device

Refinements are described to an existing fluidic temperature control system developed under a prior study which modulated temperature at the inlet to the liquid-cooled garment by using existing liquid supply and return lines to transmit signals to a fluidic controller located in the spacecraft. This earlier system produced a limited range of garment inlet temperatures, requiring some bypassing of flow around the suit to make the astronaut comfortable at rest conditions. Refinements were based on a flow visualization study of the key element in the fluidic controller: the fluidic mixing valve. The valve's mixing-ratio range was achieved by making five key changes: (1) geometrical changes to the valve; (2) attenuation of noise generated in proportional amplifier cascades; (3) elimination of vortices at the exit of the fluidic mixing valve; (4) reduction of internal heat transfer; and (5) flow balancing through venting. As a result, the refined system is capable of modulating garment inlet temperature from 45 F to 70 F with a single manual control valve in series with the garment. This control valve signals without changing or bypassing flow through the garment.

Zabsky, J. M.↗