Refinements are described to an existing fluidic temperature control system developed under a prior study which modulated temperature at the inlet to the liquid-cooled garment by using existing liquid supply and return lines to transmit signals to a fluidic controller located in the spacecraft. This earlier system produced a limited range of garment inlet temperatures, requiring some bypassing of flow around the suit to make the astronaut comfortable at rest conditions. Refinements were based on a flow visualization study of the key element in the fluidic controller: the fluidic mixing valve. The valve's mixing-ratio range was achieved by making five key changes: (1) geometrical changes to the valve; (2) attenuation of noise generated in proportional amplifier cascades; (3) elimination of vortices at the exit of the fluidic mixing valve; (4) reduction of internal heat transfer; and (5) flow balancing through venting. As a result, the refined system is capable of modulating garment inlet temperature from 45 F to 70 F with a single manual control valve in series with the garment. This control valve signals without changing or bypassing flow through the garment.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zabsky, J. M., Rask, D. R., Starr, J. B.. 1970-12-01. Optimization of a fluidic temperature control device. https://ntrs.nasa.gov/citations/19720013776