Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flowmeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

High accuracy fuel flowmeter. Phase 2C and 3: The mass flowrate calibration of high accuracy fuel flowmeters

A facility for the precise calibration of mass fuel flowmeters and turbine flowmeters located at AMETEK Aerospace Products Inc., Wilmington, Massachusetts is described. This facility is referred to as the Test and Calibration System (TACS). It is believed to be the most accurate test facility available for the calibration of jet engine fuel density measurement. The product of the volumetric flow rate measurement and the density measurement, results in a true mass flow rate determination. A dual-turbine flowmeter was designed during this program. The dual-turbine flowmeter was calibrated on the TACS to show the characteristics of this type of flowmeter. An angular momentum flowmeter was also calibrated on the TACS to demonstrate the accuracy of a true mass flowmeter having a 'state-of-the-art' design accuracy.

Craft, D. William↗

Flowmeter evaluation for on-orbit operations

Various flowmetering concepts were flow tested to characterize the relative capabilities and limitations for on-orbit fluid-transfer operations. Performance results and basic operating principles of each flowmetering concept tested are summarized, and basic considerations required to select the best flowmeter(s) for fluid system application are discussed. Concepts tested were clamp-on ultrasonic, area averaging ultrasonic, offset ultrasonic, coriolis mass, vortex shedding, universal venturi tube, turbine, bearingless turbine, turbine/turbine differential-pressure hybrid, dragbody, and dragbody/turbine hybrid flowmeters. Fluid system flowmeter selection considerations discussed are flowmeter performance, fluid operating conditions, systems operating environments, flowmeter packaging, flowmeter maintenance, and flowmeter technology. No one flowmetering concept tested was shown to be best for all on-orbit fluid systems.

Baird, R. S.↗

SPC-2918 Rev 0 MARVEL Test Loop Flowmeters

This specification contains the requirements for the design, manufacture, testing, and delivery of magnetic flowmeters to be installed on the MARVEL Primary Coolant Apparatus Test (PCAT) system. The PCAT system is a heated test loop which will be used to simulate the coolant system of a proposed sodium or NaK cooled microreactor. The system has four identical cooling loops. Installation of flowmeters on all four loops is anticipated at this time, however, the number of flowmeters may be reduced by the Project. Note that the number of flowmeters described herein is not a commitment to a particular number of procured units. The number of flowmeter units procured shall be identified on the purchase order. The MARVEL reactor is still under design, so the PCAT flowmeter design may not be directly transferrable to the reactor. It is intended that the design and development effort for the PCAT flowmeters be leveraged to the extent practical for the reactor flowmeter design.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Application of CFD to Explain Anomalous Stall Behavior of the SSME Flowmeter

The Space Shuttle Main Engine (SSME) Fuel Flowmeter is located in the duct between the low and high pressure fuel turbopumps. In the flowmeter the rotation rate of a 4-blade rotor positioned downstream of two flow straighteners is employed to measure the engine fuel flow rate and thereby control the engine mixture ratio via the engine controller. Hence, inaccurate operation of the flowmeter could have serious consequences for SSME engine operation and performance, forcing, for example, tanking of extra fuel to allow for inaccurate flowmeter measurement. Since the current flight flowmeter configuration was incorporated into the SSME in the early eighties, some anomalies in flowmeter behavior have been observed. The initial flowmeter incorporated an "egg crate" design for the two flow straighteners which turn the duct flow to make it more uniform and parallel after it has come out of the 90 degree bend just upstream of the flowmeter.

Ascoli, E.↗

Unsteady Phenomena During Operation of the SSME Fuel Flowmeter

This report describes a part of the analysis carried in support of the SSME (Space Shuttle Main Engine) Fuel Flowmeter redesign, addressing an intensely researched phenomenon known as "shifting" of the flowmeter constant value. It consists of a sudden change in the flowmeter indication, which occurs simultaneously with the onset of an oscillatory variation of the rotor speed. The change in the flowmeter indications does not correspond to a real change in the volumetric flow through the device. Several causes have been investigated in detail, in the past, without conclusive evidence towards a cause of this phenomenon. The present analysis addresses the flow physics through the flowmeter by assembling results from 3-D CFD (computational fluid dynamics) calculations, airfoil C(sub D)/C(sub L) performance curves and mass moment of inertia characteristics of the rotor into a synergistic calculation which simulates the unsteady regime of the flowmeter operation. The results show that the 4-bladed rotor interacts with the periodic flow pattern created behind the flow straightener upstream in a manner that generates a steady, periodic fluctuation in the rotor's speed. The amplitude of this fluctuation is significantly smaller than the 0.5% of mean speed threshold which constitutes a flight operational limit. When manufacturing errors occur, however, the fluctuations are amplified and can generate a significant apparent change in the flowmeter indication. Two types of possible fabrication errors-which can occur even for parts fabricated within the accepted tolerances for the blade airfoil-are presented, together with their effect on the flowmeter operation.

Marcu, Bogdan↗

High Accuracy Fuel Flowmeter, Phase 1

Technology related to aircraft fuel mass - flowmeters was reviewed to determine what flowmeter types could provide 0.25%-of-point accuracy over a 50 to one range in flowrates. Three types were selected and were further analyzed to determine what problem areas prevented them from meeting the high accuracy requirement, and what the further development needs were for each. A dual-turbine volumetric flowmeter with densi-viscometer and microprocessor compensation was selected for its relative simplicity and fast response time. An angular momentum type with a motor-driven, spring-restrained turbine and viscosity shroud was selected for its direct mass-flow output. This concept also employed a turbine for fast response and a microcomputer for accurate viscosity compensation. The third concept employed a vortex precession volumetric flowmeter and was selected for its unobtrusive design. Like the turbine flowmeter, it uses a densi-viscometer and microprocessor for density correction and accurate viscosity compensation.

Mayer, C.↗

Support of gas flowmeter upgrade

A project history review, literature review, and vendor search were conducted to identify a flowmeter that would improve the accuracy of gaseous flow measurements in the White Sands Test Facility (WSTF) Calibration Laboratory and the Hydrogen High Flow Facility. Both facilities currently use sonic flow nozzles to measure flowrates. The flow nozzle pressure drops combined with corresponding pressure and temperature measurements have been estimated to produce uncertainties in flowrate measurements of 2 to 5 percent. This study investigated the state of flowmeter technology to make recommendations that would reduce those uncertainties. Most flowmeters measure velocity and volume, therefore mass flow measurement must be calculated based on additional pressures and temperature measurement which contribute to the error. The two exceptions are thermal dispersion meters and Coriolis mass flowmeters. The thermal dispersion meters are accurate to 1 to 5 percent. The Coriolis meters are significantly more accurate, at least for liquids. For gases, there is evidence they may be accurate to within 0.5 percent or better of the flowrate, but there may be limitations due to inappropriate velocity, pressure, Mach number and vibration disturbances. In this report, a comparison of flowmeters is presented. Candidate Coriolis meters and a methodology to qualify the meter with tests both at WSTF and Southwest Research Institute are recommended and outlined.

Waugaman, Dennis↗

Application of CFD to Explain Anomalous Stall Behavior of the SSME Flowmeter

Anomalous behavior manifested in the apparent SSME fuel flowmeter constant which relates the rotor speed to the engine flowrate has been shown to be the result of wakes of the upstream hexagonal web flow straightener periodically stalling the rotor blades, thereby changing the lift on the blades and the rotation speed of the rotor. Moreover, an unsteady, two-dimensional computational fluid dynamics model of the flowmeter has shown this wake-induced stall disappearing as the straightener-rotor distance is doubled, in accord with the existing SSME flowmeter database for the previous "egg crate" flowmeter. These observations have led to a new flowmeter design which has been shown in three-dimensional CFD computations (consistent with both the previous two-dimensional analyses and with existing correlations for airfoil stall) to be much less susceptible to stalling instabilities.

Ascoli, E.↗

Data Oscillation Resolution of Propellant Flowmeter Used in FASTRAC Engine Testing

The Stennis Space Centers' horizontal test facility, Marshall Space Flight Centers' propulsion test article and the X-34 flight vehicle are designed with V-cone flowmeters for measurement of both RP-1 and LOX flow-rates for Fastrac engine testing. Delta pressure transducer data from these flowmeters are used to calibrate the RP-1 and LOX mixture ratio in the Fastrac engine. Data from the V-Cone flowmeter delta pressure transducers have excessive oscillation. The delta pressure oscillations have caused flowrate data fluctuations that interfered with making the accurate readings necessary to calibrate the RP-1 and LOX mixture ratio required for Fastrac engine operation. The objective of this report is to document the flowmeter data oscillation problem and the method used to obtain more reliable flowmeter data.

Heflin, J.↗

Testing and Comparative Evaluation of Space Shuttle Main Engine Flowmeter Bearings

This paper provides a summary of testing of Space Shuttle Main Engine (SSME) flowmeter bearings and cage material. These tests were con&cM over a several month period in 2004 at the Marshall Space Flight Center. The test program's primary objective was to compare the performance of bearings using the existing cage material and bearings using a proposed replacement cage material. In order to meet the test objectives for this program, a flowmeter test rig was designed and fabricated to measure both breakaway and running torque for a flowmeter assembly. Other test parameters,,such as motor current and shaft speed, were also recorded and provide a means of comparing bearing performance. The flowmeter and bearings were tested in liquid hydrogen to simulate the flowmeter's operating environment as closely as possible. Based on the results from this testing, the bearings with the existing cage material are equivalent to the bearings with the proposed replacement cage material. No major differences exist between the old and new cage materials. Therefore, the new cage material is a suitable replacement for the existing cage material.

Hissam, Andy↗

The NASA High Accuracy Fuel Flowmeter (HAFF) Development Program

The high accuracy fuel flowmeter development program is described. A flightworthy meter that measures mass flowrate of aircraft fuels to within + or - 0.25% of reading over a 50:1 range of flow is developed. A study of measurement techniques to achieve this goal yielded three candidates: (1) a dual turbine flowmeter with density and viscosity compensation; (2) an angular momentum flowmeter with a motor-driven, spring-restrained turbine and viscosity shroud; and (3) a vortex precission flowmeter with density and viscosity compensation. An experimental study of each technique was completed and the first two candidates were selected for prototype development.

Hobart, H. F.↗

High accuracy fuel flowmeter

All three flowmeter concepts (vortex, dual turbine, and angular momentum) were subjected to experimental and analytical investigation to determine the potential portotype performance. The three concepts were subjected to a comprehensive rating. Eight parameters of performance were evaluated on a zero-to-ten scale, weighted, and summed. The relative ratings of the vortex, dual turbine, and angular momentum flowmeters are 0.71, 1.00, and 0.95, respectively. The dual turbine flowmeter concept was selected as the primary candidate and the angular momentum flowmeter as the secondary candidate for prototype development and evaluation.

Source record↗

Rotor Re-Design for the SSME Fuel Flowmeter

The present report describes the process of redesigning a new rotor for the SSME Fuel Flowmeter. The new design addresses the specific requirement of a lower rotor speed which would allow the SSME operation at 1 15% rated power level without reaching a blade excitation by the wakes behind the hexagonal flow straightener upstream at frequencies close to the blade natural frequency. A series of calculations combining fleet flowmeters test data, airfoil fluid dynamics and CFD simulations of flow patterns behind the flowmeter's hexagonal straightener has led to a blade twist design alpha = alpha (radius) targeting a kf constant of 0.8256. The kf constant relates the fuel volume flow to the flowmeter rotor speed, for this particular value 17685 GPM at 3650 RPM. Based on this angle distribution, two actual blade designs were developed. A first design using the same blade airfoil as the original design targeted the new kf value only. A second design using a variable blade chord length and airfoil relative thickness targeted simultaneously the new kf value and an optimum blade design destined to provide smooth and stable operation and a significant increase in the blade natural frequency associated with the first bending mode, such that a comfortable margin could be obtained at 115% RPL. The second design is a result of a concurrent engineering process, during which several iterations were made in order to achieve a targeted blade natural frequency associated with the first bending mode of 1300 Hz. Water flow tests preliminary results indicate a kf value of 0.8179 for the f-irst design, which is within 1% of the target value. The second design rotor shows a natural frequency associated with the first bending mode of 1308 Hz, and a water-flow calibration constant of kf 0.8169.

Marcu, Bogdan↗

High Temperature Sodium Submersible Flowmeter Design and Analysis

This work details the design and analysis of a permanent magnet flowmeter designed to be submerged in a pool type sodium fast reactor environment. Recently developed Samarium Cobalt rare earth magnets were utilized that have demonstrated resilience to temperature and neutron flux up to 550 °C and 10 18 n/cm 2 , respectively. This paper will discuss the theory, design, calibration and uncertainty quantification of the flowmeter. The flowmeter was calibrated over a flowrate range of 11.4 - 90.9 LPM at temperatures of 220 and 400 °C, yielding an uncertainty in calibration of 2-3.6%. Here, a finite element model was developed and validated experimentally, yielding <; 3.2% error.

47 OTHER INSTRUMENTATION↗

Calibration technique for electromagnetic flowmeters

Thermal calorimetric method is used to calibrate electromagnetic flowmeters for liquid alkali metals. The electromagnetic flowmeter is placed in the liquid metal flow system in series with a thermal calorimeter. Therefore, the calculated flow rate through the calorimeter can be compared directly with the respective electromagnetic flowmeter reading.

Sawochka, S. G.↗

Use of small turbine-type flowmeters to measure flow in large pipes

Measurement of mass flow in large pipes using small turbine-type flowmeters is discussed. Experiments for determining accuracy of flowmeter and applicability to various types of flow measurement are reported. Illustration of turbine flowmeter and calibration curve are included.

Minkin, H. L.↗

Low flow vortex shedding flowmeter for hypergolics/all media

A family of vortex shedding flowmeters for flow measurement of hypergols that requires a long term operation without removal from system lines was further developed. A family of vortex shedding flowmeters without moving parts was designed. The test loop to evaluate the meters for the Freon flow, which simulates the hypergolic fluids, was modified and reconstructed. Preliminary results were obtained on the output frequency characteristics of an 1/2 inch flowmeter as a function of the flow rate.

Thinh, Ngo↗