Engineering PapersSearch

SEARCH · Engineering Papers

Results for “FIRE PREVENTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Detecting Anomalies for Fire Prevention in Distribution Systems: Challenges and Analytical Techniques

Electric utilities in California have historically been linked to up to 10% of wildfires. To mitigate this risk, Southern California Edison has invested significantly in wildfire prevention strategies, including undergrounding cables and enhancing equipment inspections. This article explores a novel approach to fire prevention by detecting anomalies in the distribution system that may indicate potential fire hazards. The focus is on identifying arcing conditions through high-resolution point-on-wave (POW) measurements. Arcing, a precursor to fires, is challenging to detect due to its subtle transients and complex system topology. The article discusses the use of advanced signal processing and machine learning techniques, such as spectral correlation function and discrete wavelet transform, to extract features from POW data and accurately identify arcing events. The study demonstrates a high accuracy rate in detecting arcing, paving the way for improved fire prevention measures in electric distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION

Review on Preprocessing Strategies, Deactivation, Thermal Safety, and Future Perspectives in Lithium-Ion Battery Recycling

The rapid growth in the use of lithium-ion batteries (LIBs) in electric vehicles, consumer electronics, and renewable energy storage has made effective end-of-life management essential. Recycling LIBs is critical not only for resource recovery and environmental protection but also for ensuring safety and economic viability. This review focuses on the preprocessing technologies that precede typical recovery processes, including disassembly, sorting, discharging, electrolyte removal, dismantling, thermal treatment, separation, and flotation. These steps play a foundational role in determining the efficiency, safety, and environmental impact of LIB recycling. LIBs pose substantial fire and explosion risks due to residual charge, flammable electrolytes, and reactive materials. The conditions and successive progression of the exothermic reactions which lead to thermal runaway has been discussed. It also explores secure deactivation techniques such as external circuit discharge, saline immersion, and thermomechanical methods, alongside fire prevention strategies including the use of flame retardants, elimination of oxidants, and reduction of heat generation and accumulation. Challenges and future directions are outlined, highlighting the need for standardized designs, automation, and safer, more sustainable recycling infrastructure. Furthermore, this review is distinguished by its focused analysis of preprocessing and deactivation steps, with particular attention to the thermal safety engineering aspects of LIB recycling.

Battery deactivation

SAVY O-ring characterization for lifetime extension

Los Alamos National Laboratory and Nuclear Filter Technology, Inc. developed the SAVY-4000 nuclear material storage container, named after the designers Stone, Anderson, Viers, and Yarbro. The SAVY 4000 meets the requirements of Department of Energy (DOE) M 441.1-1,2 Nuclear Material Packaging Manual, to protect workers who handle nuclear materials against radiation exposures resulting from the leakage of stored materials. The SAVY-4000 is an innovative and creative design: it can be opened and closed in a few seconds without using torque wrenches and instead only a tire iron or equivalent prying tool; has a built-in, fire-rated filter that prevents the build-up of hydrogen gas yet retains 99.97% of plutonium particulates at 200 ACCM rated flow; and prevents the release of stored materials upon a 12- foot drop.

42 ENGINEERING

Automated Fire Detection for Industrial Settings with Pretrained Convolutional Networks

Early fire detection in industrial environments is critical to preventing equipment damage, personal injury, and operational disruptions. Traditional smoke detectors, while effective, often experience delays due to the time required for smoke to reach sensors, allowing fires to spread. Manual fire watch operations and human surveillance of camera feeds are resource-intensive and prone to human error. To address these challenges, this paper explores the application of convolutional neural networks for automated fire detection, specifically in industrial settings. By leveraging 11 different pre-trained machine vision models from TensorFlow and enhancing them with transfer learning on a custom-built industrial fire dataset, we optimized fire detection performance. Here, we analyzed each machine vision model architecture in terms of its depth, width, and input image resolution, considering both resource requirements and detection accuracy. We further explored the option of combining multiple models into an ensemble classifier to evaluate whether the performance improvements could justify the much greater computational complexity and other practical impacts. A cost-benefit analysis is presented to evaluate the trade-offs between performance and computational expense. Our findings identify that EfficientNetV2L, specifically tailored for industrial applications, provides the optimal balance between costs involved in training and using the model versus the overall fire detection performance. Additionally, we present a qualitative analysis of model performance using the technique of gradient-based class activation mapping to provide explainability by visualizing model decisions.

artificial intelligence

Fire weather compromises forestation-reliant climate mitigation pathways

Forestation can contribute to climate change mitigation. However, increasing frequency and intensity of climate extremes are posed to have profound impact on forests and consequently on the mitigation potential of forestation efforts. In this perspective, we critically assess forestation-reliant climate mitigation scenarios from five different integrated assessment models (IAMs) by showcasing the spatially explicit exposure of forests to fire weather and the simulated increase in global annual burned area. We provide a detailed description of the feedback from climate change to forest carbon uptake in IAMs. Few IAMs are currently accounting for feedback mechanisms like loss from fire disturbance. Consequently, many forestation areas proposed by IAM scenarios will be exposed to fire-promoting weather conditions and without costly prevention measures might be object to frequent burning. We conclude that the actual climate mitigation portfolio in IAM scenarios is subject to substantial uncertainty and that the risk of overly optimistic estimates of negative emission potential of forestation should be avoided. As a way forward we propose how to integrate more detailed climate information when modeling climate mitigation pathways heavily relying on forestation.

54 ENVIRONMENTAL SCIENCES

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION

Surfactant templated biogenic nanoporous silica thermal insulation composite

Carbon-sequestration biogenic insulation materials offer a promising solution for sustainable and energy-efficient buildings. However, minimizing energy-intensive manufacturing processes and ensuring a uniform microstructure are essential to achieve widespread application. In this work, we introduce cetyltrimethylammonium bromide (CTAB) surfactant as both synthesis and dispersion template for nanoporous silica to create biogenic straw-based thermal insulation composites. As the amount of nanoporous silica increases to 72 wt%, the elastic insulation composite dried using the solvent exchange method exhibits a density of 0.058 g cm –3 , a thermal conductivity of 30.3 mW m –1 K –1 and a flexural modulus of 3.96 MPa, while demonstrating materials circularity and fire retardance. The use of CTAB surfactant effectively captures nanoporous silica, preventing its loss during manufacturing and enhancing the homogeneity and dispersion of the silica within the composite. In addition, the results show that the ethanol solvent exchange drying at ambient conditions provides the optimum thermal insulation performance with less energy consumption compared to freeze-drying.

36 MATERIALS SCIENCE

Near-Complete Sampling of Forest Structure from High-Density Drone Lidar Demonstrated by Ray Tracing

Drone lidar has the potential to provide detailed measurements of vertical forest structure throughout large areas, but a systematic evaluation of unsampled forest structure in comparison to independent reference data has not been performed. Here, we used ray tracing on a high-resolution voxel grid to quantify sampling variation in a temperate mountain forest in the southwest Czech Republic. We decoupled the impact of pulse density and scan-angle range on the likelihood of generating a return using spatially and temporally coincident TLS data. We show three ways that a return can fail to be generated in the presence of vegetation: first, voxels could be searched without producing a return, even when vegetation is present; second, voxels could be shadowed (occluded) by other material in the beam path, preventing a pulse from searching a given voxel; and third, some voxels were unsearched because no pulse was fired in that direction. We found that all three types existed, and that the proportion of each of them varied with pulse density and scan-angle range throughout the canopy height profile. Across the entire data set, 98.1% of voxels known to contain vegetation from a combination of coincident drone lidar and TLS data were searched by high-density drone lidar, and 81.8% of voxels that were occupied by vegetation generated at least one return. By decoupling the impacts of pulse density and scan angle range, we found that sampling completeness was more sensitive to pulse density than to scan-angle range. There are important differences in the causes of sampling variation that change with pulse density, scan-angle range, and canopy height. Our findings demonstrate the value of ray tracing to quantifying sampling completeness in drone lidar.

47 OTHER INSTRUMENTATION

NFPA Distributed Energy Resources Safety Training (DERST) For Emergency Responders

The National Fire Protection Association, with support from the Department of Energy, executed a multi-year initiative to develop, enhance, and disseminate Distributed Energy Resources Safety Training (DERST) tools for U.S. emergency responders. As Distributed Energy Resources (DER)—such as solar photovoltaics, battery energy storage systems (ESS), electric vehicles (EVs), and associated infrastructure—become increasingly prevalent, the NFPA identified a critical need for up-to-date standardized, accessible, and effective safety training tailored for the fire service and related public safety professionals. The project delivered a comprehensive suite of educational resources to improve responders’ abilities to safely manage DER-related incidents. This included: • Revised Modular Training Courses: Updated classroom-based DER safety courses, now modular and accessible nationwide through fire academies and the North American Fire Training Directors (NAFTD) network. • Live Burn Testing & Research: A full-scale controlled burn of a DER-equipped residential structure provided real-world data and insights, forming the basis for updated best practices. • A Gamified Simulation Tool – Firefighters Incident Response Simulation Tool (FIRST): A first-of-its-kind, multiplayer, scenario-based simulation using the Unreal Engine 5.0 to train responders in a realistic virtual, multi-DER incident environment. • Field Familiarization Software Tools & Prop Guide: Digital DER field familiarization evolutions software guide and a prop development manual to support field-based DER training exercises, enhancing responders' hands-on familiarity with DER infrastructure and collaboration on virtual incident responses. • National Dissemination Strategy: Strategic partnerships with NAFTD, Vector Solutions, and others enabled wide-scale distribution, with over 5,000 departments accessing resources and 1,100+ departments adopting the simulator in the first seven months. Also provided a web portal for easy access to all training and simulation programs developed under this grant for the U.S. responder community. Key findings from the project—particularly from the burn test—led to paradigm shifts in fire response tactics. For example, traditional approaches to garage fires may be hazardous if DERs are present, due to explosive off gassing and thermal runaway risks. The new training emphasizes scene assessment, stand-off approaches, thermal imaging verification, and careful post-incident cooling of DER components to prevent reignition. This initiative has had a significant national impact, raising awareness, enhancing preparedness, and supporting safer DER incident response practices. Significant engagement from the media, public safety organizations, and PBS coverage has further amplified the reach and adoption of NFPA’s DER safety training, tools, and simulations.

14 SOLAR ENERGY

Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation

The University of Kentucky (UKy) project titled “Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation”, DE-FE0031757, was conducted from 8/15/2019 to 8/14/2024 in two Budget Periods. Other participants included PPL Corporation and Black Dragon Double Boiler. The overall goal was to investigate the proposed self-cleaning technology to achieve ash fouling free air preheater operation in a coal-fired power plant, especially during deep cycling. All project deliverables, milestones, and success criteria were met. UKy obtained the following scientific findings. • Temporary and periodic high temperature of heating elements (450 ~ 500 °F) can prevent ash accumulation and maintain air preheater free of clogging. • The ash samples analysis and unit operation provide solid evidence of ABS formed during low load with SCR ammonia slip being the major cause of ash accumulation, and air preheater clogging can be prevented by raising the heating element temperature up to 450 °F~ 500 °F at which ABS is decomposed. • In-situ self-cleaning can be controlled by monitoring temperature and/or presetting fixed number of cleanings per day. Both approaches in pilot testing show positive results for maintaining an ash free state for the air preheater. • Temperature criteria (cold end or gas outlet temperature) for entering self-cleaning service is critical to balance the number of cleaning cycles with maintaining the ash level. • Temperature criteria (cold end or gas outlet temperature) for exiting self-cleaning service is critical to balance the duration of the cleaning cycles with maintaining the ash level.

01 COAL, LIGNITE, AND PEAT

Success Path Method: Conformance with Safety Management Systems

All industrial facilities deal with safety hazards such as equipment failures, chemical and toxic releases, and fires and explosions just to name a few. A disciplined framework for managing the integrity of operating systems and processes that handle hazardous substances by applying good design principles, engineering, and operating practices is called process safety. The goal of such framewoks is to prevent the release of energy or material that could cause harm to people or damage to equipment and/or environment. Process safety covers all aspects of facility operation also including design, maintenance, and human and organizational factors that could possibly have effect on process safety. As it will be seen from the discussion below, process safety is just one of the pieces of the much bigger matter, a safety culture. Many industries have long recognized the importance of safety culture in their day-to-day operation. Although the definition of safety culture can slightly differ from organization to organization, in general, a safety culture is how things are done to demonstrate a commitment to safety by everyone involved. An organization acquires safety culture over time as the product of individual and group values, actions, and behaviors toward overall safety. It is important to note that safety culture should not be viewed as some static state that an organization wants to reach. It is more like a constantly evolving level of “how things are done when nobody is watching.” Safety culture is an inherent characteristic of an organization, it is always present, but the level can range on a continuum from undesirable to desirable or more commonly used, from negative to positive. An example for an undesirable, negative safety culture would be a company in which accidents resulting in harm (physical and/or emotional) of its employees, equipment or surrounding environment and community occur frequently. At the other end of the spectrum would be a company in which such accidents are rare or do not occur at all (desired or positive safety culture). Every company/industry exists somewhere within this spectrum.

42 ENGINEERING

Exploring the Performance and Reliability of Screen-Printable Fire-Through Copper Paste on PERC Solar Cells

In this work, we present the performance and reliability of a fire-through copper (Cu) paste which has been screen printed on c-Si solar cell with passivated emitter rear contact (PERC). The Cu paste is fired through silicon nitride (SiN) anti-reflection coating at a peak temperature of 630 degrees C . SEM images of the Cu paste show a Cu core with ~200 nm oxide shell around the particles. This conductive oxide layer acts as a diffusion barrier between Cu and Si and prevents the degradation of cell performance during accelerated aging conditions. An efficiency of 19.250% has been achieved with Voc=654mV,FF= 76.68%, Jsc=38.40 m.A/cm 2 for champion PERC cells. Accelerated testing of the PERC mini-modules in damp heat chamber with 85 degrees C and 85% humidity have demonstrated that the devices are operational even after 1,500 hours. Devices with screen printed Ag contacts on the front side have been studied in parallel to the Cu contacts for comparison.

copper

Economic Analysis of Condition-Monitoring-Based Predictive Maintenance in Power Plants under Market Elasticity

Condition-monitoring-based predictive maintenance can increase the power plant availability by preventing forced outages. However, the actual on-stream time depends on market elasticity and dynamics, which are affected by cost and penetration of other power generation technologies. This paper develops a systematic approach for the economic analysis of investment in condition monitoring technologies with due consideration of market elasticity. Focus is on corrosion monitoring in coal-fired power plants (CFFPs) since corrosion in high-temperature coal-fired boilers is a leading cause of equipment failure. Investment in sensor networks for measuring corrosion and operating conditions like metal temperature and concentrations of O 2 and SO 2 is investigated. The unscented Kalman filter is used to estimate corrosion in the waterwall section of the boiler under multiple sensor networks. Electricity produced by CFPPs in the future in the U.S. due to changes in availability under market elasticity is studied. Sensitivity of the incremental net present value to factors like the number, type, and cost of sensors is analyzed.

Electrochemistry

Quantitative Risk Assessment for Fuel Cell Electric Bus Hydrogen Storage and Refueling Facility

It is necessary to understand the safety implications and risk mitigation options for fuel cell electric bus fleet deployment, especially for related facilities responsible for operations such as production, storage, compression, and dispensing of hydrogen for use by the buses. In this report, we present a quantitative risk assessment for a potential fuel cell electric bus fleet that was motivated by efforts to improve resilience at the Portland International Airport but can be applicable to a range of hydrogen case studies and use cases. We estimated risk for a facility that produces, stores, compresses, and dispenses hydrogen for the fleet of buses, with a focus on individual risk to people in terms of annual frequency of fatality. We considered the frequency of hydrogen leaks that could result in harmful physical outcomes like jet fires or explosions, and the consequences of those outcomes for people. We created customized fault trees to calculate the frequencies of different sizes of leaks and event sequence diagrams to calculate ignition probabilities for the various leak sizes. We also leveraged the HyRAM+ toolkit to use these inputs to calculate overall risk for the facility, which we separated into one section responsible for producing, storing, and compressing hydrogen, and one section responsible for dispensing the hydrogen to the buses. We found that the dispensing area seemed to have a higher risk than the production/storage/compression area of the facility, largely because of the inclusion of a component with a high leak frequency (the heat exchanger used to cool the hydrogen before entering the vehicle, to prevent overheating and expansion of hydrogen in the onboard tank). For the example production and refueling facility we evaluated and the data we used for the analysis, the leak frequency had a larger impact on the risk differences between the two sections on the facility, compared to the physical outcome consequence, which was slightly different due to the varying fuel conditions, but not substantially different. Actions can be taken to prevent these hazards (e.g., lowering leak frequencies in system components) or to mitigate the consequences if they do occur (e.g., installing barriers to protect people if ignition events occur). The choice of which actions to take depends not only on safety considerations but also on space, time, staffing, feasibility, and financial constraints. Therefore, the quantitative risk assessment approach can help understand relative risk contributions from different components, leak sizes, consequences, and human actions, to prioritize risk reduction strategies and balance these parameters. The outcomes of this report may be useful for a variety of stakeholders working in the hydrogen, transportation, vehicle, and aviation sector, including those responsible for aspects like facility design, operations, and regulations. There is not a single value of risk that determines whether a hypothetical system is “safe” or not. The insights about risk mitigations may be leveraged, and the quantitative risk assessment approach can be applied to other case studies to understand risk priorities and contributions specific to different FCEB and hydrogen facility uses.

08 HYDROGEN

HERO CarbonSAFE Phase 2 Project in the Columbia River Basalt Group

The Hermiston, Oregon Basalt CarbonSAFE Phase II project (HERO CarbonSAFE) seeks to accelerate the deployment of commercial carbon dioxide (CO2) storage projects in basaltic rocks. Basalt CO2 storage has several advantages to conventional saline storage reservoirs including 1. The potential for rapid mineralization of CO2, 2. Associated decreases in pressure and CO2 migration risks, 3. Reduced long-term monitoring requirements with respect to plume tracking, 4. Widespread geographic distribution and, 5. Large storage potential due to thickness, porosity, and CO2 interactions with basalt. And for locations such as the Pacific Northwest, Hawaii, Iceland, India and Japan, basalts may offer the only economically feasible option for local CO2 storage. However, there are limited field-scale assessments of CO2 storage in basalt, and current carbon capture utilization and storage (CCUS) permitting and regulatory frameworks were developed for conventional saline reservoirs. HERO CarbonSAFE is designed to address research gaps and uncertainties associated with basalt storage. Specifically, the project will assess the feasibility of CO2 injection in the deep layered basalts, long-term storage (mineralization), practical approaches for large-scale implementation (50+ million metric tons of CO2 over 30 years), lithology-specific risks, and the technoeconomic potential for CO2 storage in basalts. The HERO CarbonSAFE project will assess feasibility of developing a commercial-scale (50+ million metric tons of CO2) geological storage complex within the Columbia River Basalt Group (CRBG), a layered continental flood basalt complex that underlies Calpine’s natural gas-fired Hermiston Power Project (HPP) in Hermiston, OR (Figure 1). Under this 2-year CarbonSAFE Phase II project, the HERO team will conduct a data acquisition campaign that includes drilling a stratigraphic well to a total depth of ~1,500 m into the thick layered basalts proximal to HPP. A comprehensive well logging and hydrologic testing program will be augmented with new core collected from flow zones and sealing units, and comprehensive laboratory testing to help refine the kinetic rates of mineralization. The newly acquired information will be integrated with existing data from regional wells to correlate basalt injection zone properties to develop storage hub/commercial-scale models. Using these models, the project team will evaluate injection scenarios to define the technical and economic potential for storing a minimum of 50 million metric tons of CO2 over a 30-year period, along with a robust sensitivity analysis on key parameters governing reservoir viability for sustainable injection over a commercial project lifetime. Specific technical objectives of HERO are: (1) assessing the reservoir response of a series of stacked layered reservoir flowtop sequences occurring in this area of the CRBG to commercial-scale injection volumes; (2) extending prior efforts by the project team to characterize the deep layered basalts encountered in regional studies, to leverage prior investments by U.S. Department of Energy’s (DOE) Carbon Storage program; (3) leveraging DOE’s mineralization characterization efforts to advance model parametrization for commercial scale injection of CO2 in basalts; (4) conducting risk assessments associated with scaling up to commercial storage hub injection goals, while validating DOE’s National Risk Assessment Partnership (NRAP) tools, to identify potential constraints that would prevent the CRBG from serving as a commercial-scale storage complex; (5) developing mitigation plans to address identified risks; (6) developing a commercial-scale injection and monitoring, verification and accounting (MVA) strategy; (7) utilizing computational models to define and minimize, if possible, the Area of Review (AoR) under Class VI regulations; and (8) developing a robust CO2 management strategy for CRBG that also considers a regional source/sink approach that is responsive to stakeholder needs and industrial demand. Specific institutional objectives are: (1) identifying and developing plans to mitigate the nontechnical challenges associated with the build-out of a commercial-scale storage complex within the CRBG with integrated CO2 sources; (2) implementing the community outreach plan; (3) conducting regulatory research, including a survey of issues related to pore space ownership, MVA and long-term assurance of mineralization-based storage, to support an eventual application for a UIC Class VI permit; (4) advancing the project’s plan for CO2 liability management; and (5) continuing to refine and update the project’s economic model. The final objective is the preparation of a comprehensive Site Characterization Plan that draws upon the technical and institutional feasibility assessments to prepare the project for future commercialization efforts.

58 GEOSCIENCES