Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A High Temperature Gas Reactor Integrated Energy System Using Energy Storage as a Buffer for Hydrogen Production

Analysis of an integrated energy system producing hydrogen in a high temperature steam electrolysis system via steam provided by a sensible heat thermal energy storage system charged by a high temperature gas reactor. Preliminary results over a continuous discharge cycle and single charging cycle shows minimal reactor impact despite 25% electrical power load change. Hydrogen production is held constant with steam provided by the thermal energy storage system.

08 HYDROGEN↗

Energy Saving Analysis Using Energy Intensity Usage and Specific Energy Consumption Methods

This study presents the energy saving analysis reached through employing the energy intensity usage and specific energy consumption method. The energy analyses conducted in this study are used for implementing a new technology. However, they are additionally used to evaluate the latest concepts, techniques, processes, and uses for technologies, which are aimed at improvement of energy savings. This study shows the correlation between energy consumption, potential energy savings, and the impact of the energy assessment in different industrial sectors. The correlation is found by using two indicators: (1) the energy intensity usage (EIU) and (2) the specific energy consumption (SEC). The data analysis in this study considers the assessments for 67 industries from 2015 to 2019 and classifies those assessments using the Standard Industrial Classification (SIC) code. The results show that energy savings and energy consumption are linearly related. Also, the energy assessment improves energy performance in a more significant way for smaller companies than for larger industries. Furthermore, these results can be extrapolated by identifying the potential benefits of the energy management system (EMS) implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of fertilization on the dynamics of energy use in wheat

Plant energy use is fundamental to plant survival and growth. However, we still lack effective means to quantify plant energy use strategies. This study introduced a concept quantifying the light level at which photochemical and non-photochemical energy use in plants are in equilibrium — the photochemical compensation point (PCCP) which can be determined with chlorophyll fluorescence measurements. We used winter wheat as a test case to explore the dynamics of PCCP and its physiological and biochemical regulations. Winter wheat PCCP decreased significantly across growth stages from jointing to grain filling. Long-term nitrogen and phosphate (NP) fertilization significantly increased PCCP, whereas potassium (K) and manure (M) fertilizer supplementation had negligible effects. PCCP exhibited significant positive correlations with leaf thickness, leaf P and sulfur (S), and stomatal conductance (gs) across all growth stages. All manure-amended treatments exhibited positive correlations of PCCP with leaf N, P, K and gs, and negative correlations with leaf calcium (Ca). Random forest analysis revealed that gs was the most significant predictor of PCCP variation, followed by leaf P, iWUE, and leaf thickness across all treatments. We suggest that plant energy use strategies are strongly coupled with plant water use strategies and nutrient availability through a complex interplay of effects on physiological and biochemical traits.

energy allocation↗

DESI 2024: Constraints on physics-focused aspects of dark energy using DESI DR1 BAO data

Baryon acoustic oscillation data from the first year of the Dark Energy Spectroscopic Instrument (DESI) provide near percent-level precision of cosmic distances in seven bins over the redshift range z=0.1–4.2. Here, this paper is the follow-up to the original DESI BAO cosmology paper [A. G. Adame et al. (DESI Collaboration), arXiv:2404.03002], which considered the conventional w 0 w a cold dark matter (CDM) model. We use the novel DESI data, together with other cosmic probes, to constrain the background expansion history using some well-motivated physical classes of dark energy. In particular, we explore three physics-focused behaviors of dark energy from the equation of state and energy density perspectives: the thawing class (matching many simple quintessence potentials), emergent class (where dark energy comes into being recently, as in phase transition models), and mirage class [where phenomenologically the distance to cosmic microwave background (CMB) last scattering is close to that from a cosmological constant Λ despite dark energy dynamics]. All three classes fit the data at least as well as Λ ⁢CDM, and indeed can improve on it by Δ⁢χ 2 ≈ –5 to –17 for the combination of DESI BAO with CMB and supernova data while having one more parameter. The mirage class does essentially as well as w 0 ⁢w a CDM and exhibits moderate to strong Bayesian evidence preference with respect to Λ⁢ CDM. These classes of dynamical behaviors highlight worthwhile avenues for further exploration into the nature of dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Reducing Energy Use and Making Energy More Efficient in the Native Village of Kiana (Final Technical Report)

The goal of the Remote Alaska Community Energy Efficiency (RACEE) Competition was to advance the implementation of affordable, resilient, and clean energy-efficient solutions for remote Alaska communities. RACEE assisted Kiana with its unique challenges, mostly the remote nature of their location paired with the harsh temperatures and isolated electrical grid resulting in high energy costs. In addition to the assistance from DOE, the Alaska Energy Authority (AEA) provided direct technical assistance to RACEE recipients throughout their projects. Before Kiana started work, AEA conducted energy audits in public buildings and facilities to identify which energy measures would be most effective for the community’s energy goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Energy Use and Making Energy More Efficient in Noorvik (Final Technical Report)

Final technical report for Remote Alaska Communities Energy Efficiency (RACEE)-funded project for the City of Noorvik. The community reduced per capita energy usage by 18% from 2010 levels by participating in the three phase project that included goal setting, technical assistance, and implementation funding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Visualizing urban microclimate and quantifying its impact on building energy use in San Francisco

© 2019 Association for Computing Machinery. Weather data at nearby airports are usually used in building energy simulation to estimate energy use in buildings or evaluate building design or retrofit options. However, due to urbanization and geography characteristics, local weather conditions can differ significantly from those at airports. This study presents the visualization of 10-year hourly weather data measured at 27 sites in San Francisco, aiming to provide insights into the urban microclimate and urban heat island effect in San Francisco and how they evolve during the recent decade. The 10-year weather data are used in building energy simulations to investigate its influence on energy use and electrical peak demand, which informs the city's policy making on building energy efficiency and resilience. The visualization feature is implemented in CityBES, an open web-based data and computing platform for urban building energy research.

Hong, T↗

A measured energy use, solar production, and building air leakage dataset for a zero energy commercial building

This paper provides an open dataset of measured energy use, solar energy production, and building air leakage data from a 328 m 2 (3,531 ft 2 ) all-electric, zero energy commercial building in Virginia, USA. Over two years of energy use data were collected at 1-hour intervals using circuit-level energy monitors. Over six years of solar energy production data were measured at 1-hour resolution by 56 microinverters (presented as daily and monthly data in this dataset). The building air leakage data was measured post-construction per ASTM-E779 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization and the United States Army Corps (USACE) Building Enclosure Testing procedure; both pressurization and depressurization results are provided. The architectural and engineering (AE) documents are provided to aid researchers and practitioners in reliable modeling of building performance. The paper describes the data collection methods, cleaning, and convergence with weather data. This dataset can be employed to predict, benchmark, and calibrate operational outcomes in zero energy commercial buildings.

14 SOLAR ENERGY↗

Optimizing Energy Use in Pulp & Paper with DOE’s Energy Intensive Industries Resources

The U.S. pulp and paper industry is the third-largest energy consumer in manufacturing, accounting for roughly 10% of sector energy use. Improving energy efficiency reduces operating costs and strengthens competitiveness. To support this effort, the U.S. Department of Energy (DOE), through Oak Ridge National Laboratory (ORNL), launched the Energy Intensive Industries (EII) Initiative. A two-year pilot across 45 industrial sites identified more than 4 trillion Btu/year in potential energy savings. This presentation outlines plans for a follow-up technical assistance program tailored to pulp and paper mills. Available resources include a cost-savings scoping tool, implementation planning guidance, and technical support for applying advanced methods such as Pinch Analysis for integrated process-utilities optimization. The session introduces key Pinch Analysis principles and highlights case studies demonstrating measurable improvements. ORNL also seeks industry feedback on barriers to efficiency improvements, including technology gaps and resource needs. DOE’s broader objective is to accelerate productivity and economic competitiveness across U.S. energy-intensive industries.

Kamath, Dipti [ORNL] (ORCID:0000000278739994)↗

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

Sensitivity of occupant comfort models to humidity and their effect on cooling energy use

Residential building energy consumption in the United States has decreased steadily during the last several decades largely because of advances in building codes as well as voluntary efficiency and labeling programs, which have resulted in the reduction in building sensible loads. Building latent loads have not decreased by the same amount, and field and analytical research studies have concluded that high-efficiency, low-load homes often have elevated indoor humidity levels, possibly leading to occupant discomfort. There are discrepancies in the literature on occupant comfort as it relates to indoor humidity and recommended upper humidity limits. The choice of humidity limit could potentially change results and conclusions on the energy impacts of a new air conditioner or dehumidifier technology, changing ventilation rates, or an improved building envelope. In this study, we use building simulations to explore the impact of humidity control on cooling energy use in efficient residential buildings for different humidity limits. We look at limits based on humidity ratio (or dew point temperature), wet-bulb temperature, relative humidity, and constant slope lines based on the popular comfort models of both Fanger and Gagge. We quantify the additional energy use required to control humidity below these limits. We look at the sensitivity of the results to different temperature and humidity set points, occupant internal gains, moisture buffering levels, evaporator airflow rates, and dehumidifier energy factors. High-efficiency home predicted energy savings are more sensitive to the assumed humidity limit and cooling and dehumidification set points than the other parameters investigated in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Manufacturing Thermal Energy Use in 2014

The first data set estimates thermal energy use (i.e., fuels combusted for process heating, boilers, and combined heat and power/cogeneration) by end use, temperature, county, and facility employment size class for all U.S. manufacturing industries in 2014. The estimation methodology builds off of prior estimates of industrial energy use (https://dx.doi.org/10.7799/1481899, https://dx.doi.org/10.7799/1461488). The second data set estimates hourly heat load (as a fraction of annual energy used for heat) using hourly observations of industrial boiler and combined heat and power/cogeneration heat load from EPA's Air Markets Program Data (https://ampd.epa.gov/ampd/), weekly operating hours in 2014 from Census Quarterly Survey of Plant Capacity Utilization (https://www.census.gov/programs-surveys/qpc/data.html), and annual production hours reported by assessments conducted by Industrial Assessment Centers (https://iac.university/).

14 SOLAR ENERGY↗