Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data-acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Exploring MDSplus data-acquisition software and custom devices

MDSplus is a software tool designed for data acquisition, storage, and analysis of complex scientific experiments. Over the years, MDSplus has primarily been used for data management for fusion experiments. This paper demonstrates that MDSplus can be used for a much wider variety of systems and experiments. We present a step-by-step tutorial describing how to create a simple experiment, manage the data, and analyze it using MDSplus and Python. To this end, a custom example device was developed to be used as the data source. This device was built on an open-source electronic hardware platform, and it consists of a microcontroller and two sensors. Finally, we read data from these sensors, store it in MDSplus, and use JupyterLab to visualize and process it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring MDSplus data-acquisition software and custom devices

MDSplus is a software tool designed for data acquisition, storage, and analysis of complex scientific experiments. Over the years, MDSplus has primarily been used for data management for fusion experiments. This paper demonstrates that MDSplus can be used for a much wider variety of systems and experiments. We present a step-by-step tutorial describing how to create a simple experiment, manage the data, and analyze it using MDSplus and Python. To this end, a custom example device was developed to be used as the data source. This device was built on an opensource electronic hardware platform, and it consists of a microcontroller and two sensors. We read data from these sensors, store it in MDSplus, and use JupyterLab to visualize and process it. This project and code demo are available on the GitHub site at this URL: https://github.com/santorofer/MDSplusAndCustomeDevices

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preface to the Special Issue on Signal Processing, Data Acquisition and Front-end Systems for Radiation Detection and Measurements

This special issue of the Journal of Signal Processing Systems focuses on advancement of signal processing and data-acquisition for radiation detection and measurements. The seven articles included cover diverse topics within the scope of radiation detection ranging from understanding of fundamental fission process, instrumentation, and application of radiation interaction (e.g., tomography and imaging). The articles focus on signal processing for fission spectrometer, neutron and gamma-ray computed tomography and artificial intelligence methods, dynamic neutron imaging system, pulse-pileup correction in x-ray spectroscopy and calibration methods in radiation measurement.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Gaussian processes for autonomous data acquisition at large-scale synchrotron and neutron facilities

The execution and analysis of complex experiments are challenged by the vast dimensionality of the underlying parameter spaces. Although an increase in data-acquisition rates should allow broader querying of the parameter space, the complexity of experiments and the subtle dependence of the model function on input parameters remains daunting owing to the sheer number of variables. New strategies for autonomous data acquisition are being developed, with one promising direction being the use of Gaussian process regression (GPR). GPR is a quick, non-parametric and robust approximation and uncertainty quantification method that can be applied directly to autonomous data acquisition. We review GPR-driven autonomous experimentation and illustrate its functionality using real-world examples from large experimental facilities in the USA and France. We introduce the basics of a GPR-driven autonomous loop with a focus on Gaussian processes, and then shift the focus to the infrastructure that needs to be built around GPR to create a closed loop. Finally, the case studies we discuss show that Gaussian-process-based autonomous data acquisition is a widely applicable method that can facilitate the optimal use of instruments and facilities by enabling the efficient acquisition of high-value datasets.

36 MATERIALS SCIENCE↗

The ScIDEP muon radiography project at the Egyptian Pyramid of Khafre

The ScIDEP Collaboration is constructing muon telescopes based on scintillator technology to investigate the internal structure of the Egyptian Pyramid of Khafre at Giza near Cairo using cosmic-ray muons. The collaboration aims to scan the pyramid from multiple viewpoints, both inside the king’s burial chamber that is located centrally at the base of the pyramid, and outside of the pyramid, to potentially identify any new internal structures. An overview of the project is presented, including the development of the data-acquisition system, the simulation framework, and very first detector studies.

47 OTHER INSTRUMENTATION↗

Correcting impedance measurements for background parasitics to characterize circuit components in cryogenic environments

Predictable circuit response is a critical prerequisite for accurate electronic measurements. Here, we describe a powerful yet straightforward experimental method and analysis model that utilizes an affordable LCR meter in conjunction with an in situ parasitic-impedance background-correction procedure to measure the temperature-dependent impedance (magnitude and phase) of up to ten individual passive circuit elements in a single cryostat run. We show how the model unambiguously identified a ∼20× drop in capacitance for 22 μF 5XR multilayer ceramic capacitors cooled from 300 K to 360 mK in an environment with a parasitic capacitance of ∼300 pF. The same experimental procedure, based on a simple two-wire measurement, was also used to measure 10 and 22 pF thin-film capacitors and 100 MΩ thick-film resistors. The results showed that the resistor values increased by up to an order of magnitude when the devices were cooled from 300 K to 360 mK. Most importantly, we showed that the simple data-acquisition method, coupled with our analysis model, enabled the measurement of component parasitics, and effectively extended the accuracy of a commercial LCR meter beyond its manufacturer-guaranteed values for a wide range of measurement frequencies. We also showed that, in the current configuration, our simple approach is limited to a capacitance accuracy of ∼10 pF.

Carpenter, R. J. [Santa Clara Univ., Santa Clara, ↗

X-ray fluorescence microscopy methods for biological tissues

Abstract Synchrotron-based X-ray fluorescence microscopy is a flexible tool for identifying the distribution of trace elements in biological specimens across a broad range of sample sizes. The technique is not particularly limited by sample type and can be performed on ancient fossils, fixed or fresh tissue specimens, and in some cases even live tissue and live cells can be studied. The technique can also be expanded to provide chemical specificity to elemental maps, either at individual points of interest in a map or across a large field of view. While virtually any sample type can be characterized with X-ray fluorescence microscopy, common biological sample preparation methods (often borrowed from other fields, such as histology) can lead to unforeseen pitfalls, resulting in altered element distributions and concentrations. A general overview of sample preparation and data-acquisition methods for X-ray fluorescence microscopy is presented, along with outlining the general approach for applying this technique to a new field of investigation for prospective new users. Considerations for improving data acquisition and quality are reviewed as well as the effects of sample preparation, with a particular focus on soft tissues. The effects of common sample pretreatment steps as well as the underlying factors that govern which, and to what extent, specific elements are likely to be altered are reviewed along with common artifacts observed in X-ray fluorescence microscopy data.

Pushie, M. Jake (ORCID:0000000174945427)↗

Development of a Data Overflow Protection System for Super-Kamiokande to Maximize Data from Nearby Supernovae

Neutrinos from very nearby supernovae, such as Betelgeuse, are expected to generate more than ten million events over 10 s in Super-Kamokande (SK). At such large event rates, the buffers of the SK analog-to-digital conversion board (QBEE) will overflow, causing random loss of data that are critical for understanding the dynamics of the supernova explosion mechanism. In order to solve this problem, two new data-acquisition (DAQ) modules were developed to aid in the observation of very nearby supernovae. The first of these, the SN module, is designed to save only the number of hit photomultiplier tubes during a supernova burst and the second, the Veto module, prescales the high-rate neutrino events to prevent the QBEE from overflowing based on information from the SN module. In the event of a very nearby supernova, these modules allow SK to reconstruct the time evolution of the neutrino event rate from beginning to end using both QBEE and SN module data. This paper presents the development and testing of these modules together with an analysis of supernova-like data generated with a flashing laser diode. We demonstrate that the Veto module successfully prevents DAQ overflows for Betelgeuse-like supernovae as well as the long-term stability of the new modules. During normal running the Veto module is found to issue DAQ vetos a few times per month resulting in a total dead-time less than 1 ms, and does not influence ordinary operations. Additionally, using simulation data we find that supernovae closer than 800 pc will trigger the Veto module, resulting in a prescaling of the observed neutrino data.

F20 Instrumentation and technique↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

artdaq

The artdaq toolkit is a data-acquisition framework designed for high-energy physics experiments. It provides a flexible, reliable backbone for data transfers and has several locations where users can perform custom analysis tasks using the art framework.

Flumerfelt, EricL. [Fermi National Accelerator Lab↗

otsdaq

otsdaq is a Ready-to-Use data-acquisition (DAQ) solution aimed at scaling down to test-beam, detector development, and other rapid-deployment scenarios; and scaling up through the development cycle to fullscale production and operation. otsdaq uses the artdaq DAQ framework under-the-hood, providing flexibility and scalability to meet evolving DAQ needs. otsdaq provides a library of supported front-end boards and firmware modules which implement a custom UDP protocol. Additionally, an integrated Run Control GUI and readout software are provided, preconfigured to communicate with otsdaq firmware.

Rivera, Ryan [Fermi National Accelerator Laborator↗

Pulse-burst spontaneous Raman thermometry of unsteady wave phenomena in a shock tube

A high-speed temperature diagnostic based on spontaneous Raman scattering (SRS) was demonstrated using a pulse-burst laser. The technique was first benchmarked in near-adiabatic H 2 -air flames at a data-acquisition rate of 5 kHz using an integrated pulse energy of 1.0 J per realization. Both the measurement precision and accuracy in the flame were within 3% of adiabatic predictions. Furthermore, this technique was then evaluated in a challenging free-piston shock tube environment operated at a shock Mach number of 3.5. SRS thermometry resolved the temperature in post-incident and post-reflected shock flows at a repetition rate of 3 kHz and clearly showed cooling associated with driver expansion waves. Collectively, this Letter represents a major advancement for SRS in impulsive facilities, which had previously been limited to steady state regions or single-shot acquisition.

47 OTHER INSTRUMENTATION↗

Verification of Spent Fuel Inside Dry Storage Casks by Cask Top Fast Neutron Mapping (FY2023 Mid-Year Report)

This project is developing a prototype scanner array verification system for detection of missing fuel assemblies in spent-fuel storage casks. The prototype consists of six fast-neutron scintillator detectors mounted to a linear actuator frame that is placed on the top of a spent fuel cask to scan across all fuel assembly positions. The scanner array was assembled and tested at LLNL in FY2022. A field test schedule has been requested at the Idaho National Laboratory (INL) Cask Farm site for FY2023. Note that the Cask Farm contractor determines this scheduling and not INL directly. Further system automation will be designed and implemented with the goal of obtaining a level of system operation that meets IAEA needs. This includes integration of the scanner array and data-acquisition control software into a single interface for operator use. In addition, commercial operators and the IAEA may have special requirements for portability, shipping, lifting, and installation. Prior to the Field Test at INL, the system will be operated at LLNL to exercise lifting procedure and linear actuators, monitor stability of detector energy and pulse-shape discrimination calibration, and test system software integration efforts. Following the Field Test, we will present results and discuss the technology with the IAEA. We will incorporate additional improvements to the system based on lessons learned from the field test and feedback from the IAEA. If successful, the technology can be transferred to the IAEA or other stakeholders for assessment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Practical and Optimal Sequential Bayesian Experimental Design for Complex Systems Incorporating Human Experimenter Preferences (Final Scientific/Technical Report)

Experiments are indispensable for developing models of complex systems. Carefully designed experiments can provide substantial savings for these expensive data-acquisition opportunities. However, designs based on heuristics are often suboptimal for systems with multiphysics, nonlinear dynamics, and uncertain and noisy environments. Optimal experimental design, while leveraging predictive models, seeks to systematically quantify and maximize the value of experiments. In this project, we focused on the design of multiple experiments, where current approaches are largely suboptimal: batch-design does not adapt to new data acquired during the experiment campaign (no feedback), and greedy/myopic design ignores future dynamics and consequences (no lookahead). We developed the mathematical framework and computational methods for sequential optimal experimental design (sOED) for complex systems. We enabled tractable model-based sOED in a rigorous manner through novel algorithms based on reinforcement learning, and investigated the effects of human experimenters on the design process. Our methods are fully Bayesian, able to quantify and update uncertainty in a principled manner. The traits aimed by our approach—mathematical rigor and optimality, human effects and uncertainty quantification, computational practicality—are crucial for elevating the standards of artificial intelligence (AI) to support decision-making in scientific domains, and contribute toward trust and realistic adoption of AI in experimental design practice.

97 MATHEMATICS AND COMPUTING↗

Design and Performance of a Smartphone-based Cosmic Ray Observatory

This dissertation examines the feasibility of appropriating the global network of smartphones as an observatory for ultra-high-energy cosmic rays. An application and cloud-based data-acquisition system are first proposed for such an observatory, in which heterogenous devices self-calibrate and server feedback optimizes individual device triggers. Methods of monitoring and manually controlling this network are also examined. Detection efficiencies for cosmic muons, MeV-scale gamma rays, and 120 GeV protons are then measured for this trigger, with which a Monte Carlo pixel model is fine-tuned. Extending this model to cosmic ray showers, the effective area of the observatory for super-GZK primaries is shown to equal that of the Pierre Auger Observatory with a global participation rate under 0.1%, far below initial estimates presented in Ref. [83]. A vastly improved sensitivity to photons and more precise modeling of electrons are primarily responsible for this discrepancy, though more refined models of the combinatorial background may yet lead to more stringent requirements.

Swaney, Jeff↗

Data Storage for HEP Experiments in the Era of High-Performance Computing

As particle physics experiments push their limits on both the energy and the intensity frontiers, the amount and complexity of the produced data are also expected to increase accordingly. With such large data volumes, next-generation efforts like the HL-LHC and DUNE will rely even more on both high-throughput (HTC) and high-performance (HPC) computing clusters. Full utilization of HPC resources requires scalable and efficient data-handling and I/O. For the last few decades, ROOT has been used by most HEP experiments to store data. However, other storage technologies like HDF5 may perform better in HPC environments. Initial explorations with HDF5 have begun using ATLAS, CMS and DUNE data; the DUNE experiment has also adopted HDF5 for its data-acquisition system. This paper presents the future outlook of the HEP computing and the role of HPC, and a summary of ongoing and future works to use HDF5 as a possible data storage technology for the HEP experiments to use in HPC environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗