Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CONDUCTING MEDIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Machine-Learning-Guided Insights into Solid-Electrolyte Interphase Conductivity: Are Amorphous Lithium Fluorophosphates the Key?

Despite decades of study, the identity of the dominant Li + -conducting phase within the inorganic SEI of Li-ion batteries remains unresolved. While the mosaic model describes LiF/Li 2 O/Li 2 CO 3 nanocrystallites within a disordered matrix, these crystalline phases inherently offer limited ionic conductivity. Growing evidence suggests that interfaces, grain boundaries, and amorphous phases may instead host the primary fast-ion pathways. Using diffusion-based generative structure prediction and machine-learning interatomic potentials (MLIPs), we investigate lithium difluorophosphate (LiPO 2 F 2 ), a key mixed-anion decomposition product of phosphorus- and fluorine-containing electrolytes. We identify a stable crystalline polymorph and demonstrate that the amorphous counterpart is conductive, with projected room-temperature σ ≈ 0.18 mS cm –1 and E a ≈ 0.40 eV. Here, this enhancement stems from structural disorder flattening the Li site-energy landscape and a low formation energy for Li-interstitial defects, which supplies additional mobile carriers. We propose amorphous mixed-anion Li-P-O-F phases as a promising conducting medium in the SEI, offering a specific target for engineering improved battery interfaces.

Zhong, Peichen [University of California, Berkeley

Yttrium Contenting Compositionally Complex Medium-Entropy Li-Garnet Electrolyte with Improved Ionic Conductivity

The compositionally complex medium/high-entropy design concept can greatly expand the categories and affect the properties of the materials. With such a designing concept, a medium-entropy Li-garnet electrolyte with appropriate yttrium content (formula Li 6.6 La 3 ZrNb 0.3 Ta 0.3 Hf 0.3 Y 0.1 O 12 ) shows a record-high ionic conductivity of ∼5.7 × 10 –4 S/cm, the highest reported for any single-site substituted high/medium-entropy Li-garnet. The assembled Li metal symmetric cells also show stable long-term cycling (0.1 mA/cm 2 for over 200 h). Neutron powder diffraction and Rietveld refinement results indicate that a competing conduction mechanism between (1) occupancy on high mobility of 96h sites and (2) the associated site vacancies and the bond length requires an appropriate content of Y for enhanced ionic conductivity. Li-ion hopping through the bottleneck can also contribute to the conductivity. Finally, density functional theory and Born–Oppenheimer molecular dynamics simulations also indicate the high mobility and number of hopping transitions of Li ions, contributing to the high ionic conductivity.

Li-garnet

Impact of Cyber Threat Awareness on Driver Response to an Unexpected Vehicle Cyberattack

Here, the integration of advanced cyber-physical systems in heavy vehicles introduces new vulnerabilities by expanding the possibility of cyberattacks. The objective of this study is to evaluate (1) how threat awareness influences driver response to an unexpected cyberattack, (2) how the provision of a basic cyberattack response protocol influences driver performance, and (3) how professionally trained versus standard drivers compare in their responses to a cyberattack. An on-road driving study (N = 50) was conducted using a medium heavy-duty vehicle. Participants were divided into three groups: Control, which remained unaware of any potential cyberattack; Aware, which was informed about the potential cyberattack; and Aware + Protocol, which received the same warning as the Aware group with the addition of a basic cyberattack response protocol. An instrument cluster cyberattack was executed at the same location for all participants. The findings highlight the essential role of awareness and response protocol in enhancing driver response to an unexpected vehicle cyberattack. The Aware + Protocol group had the highest stop rate (100%) and the shortest stopping distances (224 m for standard drivers and 254 m for professionals), compared to the Control group (828 and 520 m, respectively). Aware + Protocol also had the fastest reaction time, averaging 7.53 s, versus 16.12 s (Aware) and 30.29 s (Control). These results emphasize that awareness alone is insufficient. Providing drivers with clear, actionable protocols significantly improves their ability to react quickly and safely to cyberattacks, enhancing overall road safety.

Cybersecurity

Rheology and engine performance of very low sulfur fuel oil blended with 10% fast pyrolysis and hydrothermal liquefaction oils in a 2-stroke crosshead engine

The performance and emissions for a downscaled single-cylinder 2-stroke crosshead engine were determined for a very low sulfur fuel oil (VLSFO) when blended with 10 wt.% fast pyrolysis (FP) or hydrothermal liquefaction (HTL) bio-intermediates. The FP and HTL oils were derived from biomass and were observed to contain lower molecular weight (MW) hydrocarbons than neat VLSFO (which was evaluated as a baseline comparison). The addition of either biofuel reduced the overall viscosity of the VLSFO. Aging tests at 50, 90, and 120°C showed that the dynamic viscosity of VLSFO increased with exposure time up to two weeks. Similar trends were observed for the FP and HTL blends, but a pronounced spike in viscosity occurred for these fuels during the early period of exposure. None of the viscosity increases exceeded the operational limits of fuel system pumps. Engine performance studies were conducted under low, medium and high load operational settings. The relative performance of the test fuels was highly dependent on operating condition. In general, the engine results for the three test fuels were similar, but modest improvements in brake thermal efficiency and brake specific fuel consumption were observed, which may be attributed to the heightened reactivity of low molecular weight fraction of the FP and HTL oils.

09 BIOMASS FUELS

Total Cost of Ownership Reduction Using Passive Pre-Chamber Ignition in Natural Gas Engines

Spark plug durability is a factor affecting the total cost of ownership (TCO) of spark-ignited natural gas engines, with some heavy-duty platforms requiring plug replacement after only 750 hours of operation. The high ignition energy demand under lean or diluted conditions accelerates electrode wear, shortening plug life and increasing maintenance frequency. This work evaluates passive pre-chamber (PC) ignition operating at lowered spark energies as a strategy to reduce spark energy requirements and extend plug durability, thereby lowering TCO. Experiments were conducted on a medium-duty Cummins 6.7L ISB engine at 1600 RPM and 50% load under varying exhaust gas recirculation (EGR) dilution levels (0–40%). Two passive pre-chambers with 1.1 mm and 1.6 mm nozzle diameters were compared with conventional spark ignition (SI). SI was operated with a fixed coil dwell of 4 ms (~90 mJ), while the PC configuration was tested across 2–4 ms dwell times (~30–90 mJ). Cylinder pressure analysis revealed that PC ignition sustained stable combustion at significantly lower spark energies than SI, with improved combustion stability at ~30 mJ compared with SI at ~90 mJ. The PC system also extended the dilution tolerance beyond that achievable with SI, while delivering up to ~2% higher indicated thermal efficiency and reducing the COV by nearly 90% at 30% EGR. A TCO analysis was conducted to assess the economic benefit of adopting a passive PC system operating at reduced spark energies compared to SI. It was found that adopting a passive PC system could reduce TCO by approximately $11,000 per engine over a five-year operational period, primarily due to fuel savings, extended spark plug life, and reduced maintenance frequency. These projections were weighed against the additional hardware cost of the pre-chamber, yielding a rapid estimated return on investment of ~300 operating hours. Therefore, this work motivates continued research and development of passive PC technology and its commercial adoption in natural gas engines used in transportation applications.

Dhotre, Akash [University of Minnesota]

Thermal conductivity of 3D-printed block-copolymer-inspired structures

This study primarily focuses on examining the impact that geometric structure has on thermal conductivity of multi-phase constructs in different 3D-printed poly(lactic acid), PLA, samples. The investigated structures are inspired by morphologies formed by diblock copolymers: lamellae, hexagonally packed cylinders, and gyroid. This research also investigates how volume percentage and material combination influence the thermal conductivity of these structures. Further, the samples can be tailored to simulate various thermal management structures observed in practical applications, such as thermal interface materials in electronic devices. Thermal conductivity ratio is controlled using air, the least conductive material at 0.026 W/(m K), PLA at 0.136 W/(m K), and thermal paste at 5.11 W/(m K). Different models were tested against thermal conductivity measurements in order to capture the effect of material type (PLA-Air versus PLA-Thermal Paste), volume percentage, structure, and orientation. Simple, effective medium models were good predictions of thermal conductivity in lamellar structures, but it was necessary to develop models for conduction through cylindrical and gyroid structures. Finally, all results were normalized to find a universal model that is independent of structure and material. This approach provides a simple method to predict how to reduce or enhance transport properties and heat management capabilities of 3D printed objects.

36 MATERIALS SCIENCE

ThermoPI—an Online Tool to Calculate Heat Transfer Through Foam Insulation

Thermal insulation materials with ultra-low effective thermal conductivity are crucial for a multitude of applications. Over the years, a significant amount of experimental work has been dedicated to creating new insulation materials with low thermal conductivity. Similarly, substantial efforts have been made to enhance the theoretical understanding of thermal transport mechanisms in thermal insulation materials and to push the boundaries of lower thermal conductivity. However, ample room remains for enhancing the thermal resistivity of closed-cell foam insulations. To aid in the development of ultra-low effective thermal conductivity foam insulations, Oak Ridge National Laboratory has introduced a unique online tool, ThermoPI. This tool calculates not only the effective thermal conductivity but also the thermal conductivity components for porous materials, including gases, solids, and radiative, based on the materials’ structural information (e.g., porosity, pore size, gas species, pressure, solid species, pore geometry, and temperature).This tool collected and improved the existing theoretical models for thermal insulation materials’ gas, solid, and radiative thermal conductivity. These improved models have been validated with experimental data. Effective medium theory and sound velocity softening effects are considered for solid thermal conductivity. The built-in solid materials include polystyrene, polyurethane, polyethylene, and silica. Users are allowed to input new solid materials that are not built inside the tool. For gas thermal conductivity, the subcontinuum Knudsen effect is considered. In addition to several built-in gases, users can input new gases. For solid and radiative thermal conductivity calculations, several models are available to select, and the tool can determine the best model to choose based on the materials that users input. Users are also allowed to change selections manually. In addition, the tool can also calculate the effect of interfacial resistance on the overall thermal conductivity of layered materials. This work will elaborate on the tool and discuss how it can guide the development of new insulation products.

Shrestha, Som [ORNL] (ORCID:0000000183993797)

An Extension Industrial Assessment Center in Eastern Great Lakes Region

The extension IAC at CWRU is funded for 3 years to conduct 10 assessments of small and medium-sized manufacturing facilities each year in Eastern Great Lakes region. Total 30 assessments was proposed in the SOPO but due to the Covid-19 pandemic, the IAC program was suspended for 1.5 years. A total of 20 assessments was contracted to the extension IAC at CWRU which have been successfully accomplished. In the proposal, we proposed to train 18 students in the extension IAC program, and actually we selected and trained 19 students even though the IAC project was suspended during half of its project period.

42 ENGINEERING

Performance Enhancement of Medium Temperature Baked Nb SRF Cavity by Surface Contamination Removal

Medium-temperature (mid-T) baking, typically conducted at 300 350 C, enhances the quality factor of niobium (Nb) superconducting radio frequency cavities. However, surface contamination introduced during vacuum furnace baking can limit the cavity performance. To investigate this effect, a 1.3 GHz single-cell Nb cavity underwent mid-T baking, followed by a chemical treatment to remove the surface contaminants. Post-treatment measurements revealed a significant improvement in both the quality factor and the quench field.

Chouhan, Vijay [Fermilab]

Ab Initio Simulation of Medium-Range Ordering in Ionic Glass Electrolytes LiSiPON and LiNaSiPON

Ionic glasses can exhibit a unique combination of optical transparency, electronic resistivity, ionic conductivity, and mechanical ductility. The origin of the relatively high ionic conductivity and ductility is poorly understood. Recently, these ionic glasses were found to have medium-range ordering (MRO) similar to that of metallic glasses. This MRO significantly impacts the properties of metallic glasses and is also expected to significantly impact the properties of ionic glasses. Here, this work used ab initio molecular dynamics (AIMD) simulations to study the effect of ionic glass composition on the MRO. The AIMD models showed that the degree of MRO increased as the temperature of the LiSiPON ionic glass decreased. The modeling also showed that the MRO is suppressed when 50% of Li is substituted with Na. This work lays the foundation for using AIMD to identify clear structure–property relationships in ionic glasses, allowing their properties to be optimized.

Osetsky, Yuri N. [Oak Ridge National Laboratory (O

Influence of Inorganic Carbon Sources on Low-pH Succinic Acid Production by Issatchenkia orientalis : Process Insights and Kinetic Analysis

Bio-based succinic acid (SA) production has attracted significant interest; however, the relationship between fermentation conditions and SA biosynthesis remains insufficiently understood, particularly under low-pH operation. In this study, an engineered, acid-tolerant, nonmodel yeast, Issatchenkia orientalis , was employed to investigate the role of inorganic carbon supplementation in SA production from glucose. Because regulation of gas-phase CO 2 during fermentation is challenging due to low solubility and off-gas losses, liquid-phase inorganic carbon sources, carbonic acid (H 2 CO 3 ) and sodium carbonate (Na 2 CO 3 ), were evaluated as indirect CO 2 donors. Fermentations were conducted in a corn steep liquor-based medium under acidic conditions. Shake-flask experiments demonstrated that H 2 CO 3 supplementation increased SA production, achieving a maximum titer of 8.9 g/L and a yield of 0.46 g/g glucose. Kinetic analysis of bench-scale fermentations showed that the SA formation was well described by the Luedeking–Piret model, indicating mixed growth-associated product formation with a substantial nongrowth-associated contribution under carbonic acid supplementation. Guided by these kinetic insights, a two-stage fed-batch fermentation strategy was implemented, resulting in an SA titer of 30 g/L and a yield of 0.57 g/g glucose within 115 h. Overall, this work provides process-relevant insights into integrating inorganic carbon utilization with low-pH fermentation to inform more sustainable SA biomanufacturing.

fed-batch fermentation

Unraveling the Origin of Glassy Thermal Transport in Medium-Entropy Semiconductors: From Nanoscale Phase Segregation to Atomic-Scale Lattice Distortion

Thermoelectric (TE) materials can directly and reversibly convert heat into electricity, offering a promising pathway for reshaping the global energy landscape. The performance of thermoelectric materials is evaluated using the figure of merit, zT = S 2 σT/κ, which can be optimized by improving Seebeck coefficient (S) and electrical conductivity (σ) while suppressing the thermal conductivity (κ) at the operating temperature (T). Here, we introduce a medium-entropy metal chalcogenide that exhibits phonon-glass electron-crystal behavior. The conventional perspective hypothesizes that the suppression of thermal transport arises solely from disordered atomic occupation, which enhances alloy scattering mechanisms for phonon transport. However, emerging evidence suggests the presence of structural and chemical inhomogeneity at multiple length scales in entropy-engineered materials, a phenomenon that has rarely been investigated in detail.

Liu, Yukun [Northwestern Univ]

A buffering heat exchanger/thermal energy storage system for desalination applications

A buffering heat exchanger/thermal energy storage (BHXTES) system was designed using a fast-response phase-change material/graphite foam (PCM/GF) medium for desalination and potentially other industrial applications. Unlike a store-now-and-use-later TES system, this study focused on developing a dynamically balanced, continuously used, system that optimized three functions. A lab-scale prototype was designed and fabricated with a PureTemp 151/GF storage medium. The experimental data showed excellent thermal performance repeatability indicating minimal effects of PCM expansion and contraction on the GF as well as negligible PCM redistribution effects. The experimental data also served as a validation of the numerical model of the BHXTES system, after which optimization of the BHXTES system was conducted through numerical simulations for both PureTemp 151/GF and solar salt/GF as the storage medium. The results show that, with a Therminol 55 heat transfer fluid, continuous operation of the system can be realized with a solar energy source through cycles of 8-h changing for desalination and energy storage with the supplied heat followed by 16-h discharging for desalination with the stored energy. As a result, the working fluid outlet temperatures are generally in the ranges of approximately 128–160 °C for a PureTemp 151/GF medium and 198–220 °C for a solar salt/GF medium.

Buffering

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Amorphous ZrCl 4 -Based Superionic Conductor as a Cost-Effective Solid Electrolyte for Batteries

Developing highly conductive and cost-effective solid electrolytes is essential for the commercialization of all-solid-state batteries (ASSBs). Zr-based halide electrolytes hold great promise due to their low estimated cost and high oxidation stability. However, the ionic conductivities of most of them are not high enough to enable moderate- and high-rate cycling of ASSBs. Here, fast ion transport is achieved in a group of cost-effective ZrCl 4 -based electrolytes via a design strategy to create highly disordered amorphous structures. Amorphous Li 0.8 ZrCl 4 (SO 4 ) 0.4 , with a low estimated cost of $21 kg –1 , achieves an ionic conductivity of 1.86 mS cm –1 at 25 °C. It also shows a high oxidation limit of 4.5 V vs Li/Li + and good compatibility with high-voltage cathodes, as demonstrated by the stable cycling of ASSBs (73.7% capacity retention after 1000 cycles at 1 C). Synchrotron X-ray diffraction, pair distribution function analysis, and electrochemical impedance spectroscopy reveal that the outstanding conductivity of these amorphous electrolytes is closely related to their short-range and medium-range ordering, revealing new insights for designing high-performance, cost-effective solid electrolytes.

Zhang, Guangxing [Georgia Institute of Technology,

Structural origin of disorder-induced ion conduction in NaFePO 4 cathode materials

Diffusion in NaFePO 4 can be enhanced through amorphization. Based on computations using DFT and machine learning potentials, we ascribe this phenomenon to the formation of less constrained Na-ion environments upon disordering. Most modern battery technologies depend on solid-state crystalline cathode materials. However, some of these materials are constrained by the low ionic conductivity of their most stable phases. An example of this is maricite (NaFePO 4 ). Interestingly, experiments have shown that maricite can improve its rate capability through disordering (amorphization). However, experimental characterization of amorphous cathode materials remains a major challenge, hindering a clear understanding of the structural origin of the disorder-induced improvement in sodium-ion mobility. To address this, we here employ molecular dynamics simulations by first training a machine learning potential for NaFePO 4 based on the atomic cluster expansion approach and a batch active learning potential parameterization scheme. This potential is then applied to explore the structural and dynamical properties of NaFePO 4 glasses as cathode materials. Specifically, we investigate the effect of glass structure on sodium-ion diffusion, revealing the relative influences of short-range and medium-range order features. We find significant heterogeneity in sodium-ion diffusivity in the glass, with fast-conducting ions residing in less constrained atomic environments with fewer P and Fe neighbors. These more mobile ions are also surrounded by larger ring-type structures. Overall, the results and developed approach present promising avenues for developing high-performance glassy cathodes for next-generation batteries.

Christensen, Rasmus

Evolution of radiative thermal instability in a confined medium

Thermally bistable fluid tends to self-organize into clouds of hot and cold material, which are internally uniform and separated by thin conduction fronts. The evolution of these clouds has been studied for isobaric systems, but when pressure is instead treated as a dynamical quantity and allowed to evolve self-consistently, fundamentally different dynamics appear. Such a treatment is necessary in some laboratory plasmas, whose volume is constrained but whose pressure can vary. Here, solutions are derived for the evolution of clouds, accounting for pressure variation and interactions between conduction fronts. Additional stable configurations and secondary instabilities are derived, which may be relevant to fusion plasmas and to the study of photoionized plasma in the laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY