Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CFM Technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

Membrane-based Ionic Liquid Absorption System for Ultra-Efficient Dehumidification and Heating

The project team – comprising the University of Florida (UF), GTI Energy, and Modine Manufacturing – sought to develop a highly efficient heat-powered absorption cycle with combined dehumidification and heat pumping. This DOE-supported project advanced the technology from a TRL of 3 to 6, culminating in the development of a 1,000 CFM system. Key innovations implemented in the system addressed the low efficiency, size, cost, and reliability challenges of conventional absorption cycles. Specifically, the system was enabled by: (1) a semi-open cycle that allowed simultaneous dehumidification and heat recovery, (2) non-crystallizing ionic liquids (ILs) that enabled “double-effect” operation at elevated temperatures without the need for costly control equipment, (3) a compact membrane-based absorber that confined the IL and directly cooled it to achieve low dew points, and (4) a novel, highly integrated desorber–condenser assembly that reduced size, weight, and cost. The technology was developed with commercial HVAC applications in mind, particularly for separate sensible and latent cooling (SSLC), an innovation aimed at achieving independent and more efficient humidity control.

42 ENGINEERING↗

Numerical analysis of air dehumidification through electrospray-enhanced vortical flow cyclone separator

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air significantly below its dew point temperature. Here, this study numerically investigates air dehumidification achieved by electrostatic and dielectrophoresis forces in a converging duct and centrifugal principles in cyclone separators. An electrospray was employed to energize water droplets, which then captured water vapor via dielectrophoresis. A novelty of the present study is the inclusion of a cyclone separator positioned downstream of the electrospray. This combination increased the dehumidification efficiency and controlled the flow of the condensate. By integrating electrospray technology and applying an electric field, this study examines the impact of particle separation efficiency, pressure drops, and cyclone performance on air dehumidification. The control parameters for air dehumidification were investigated. Three cyclones were modelled for airflow rates of 5 cubic feet per minute [cfm] (0.0024 m 3 /s), 38 cfm (0.0179 m 3 /s), and 200 cfm (0.094 m 3 /s). The results indicated air dehumidification was up to 5.7 % under environmental conditions, similar to those used to validate the CFD model. The degree of air dehumidification was primarily influenced by the electric charge acquired by the water droplets, their flight trajectory, and the vorticity intensity within the cyclone. Air dehumidification could increase by up to 13 % by increasing the number of droplets injected into the air stream, the flight time, and the electrical charge. The breakdown electric field strength threshold near the electrospray was a limiting factor for further enhancing dehumidification performance. This study examines the optimization of an electro-assisted dehumidification system that includes cyclone-based droplet separation through numerical analysis. The results provide insights into the design of energy-efficient air treatment technologies.

42 ENGINEERING↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

Electrochemically Regenerated Solvent for Direct Air Capture with Co-generation of Hydrogen at Bench-scale

The goal of this final project report is to summarize the work conducted on project DE-FE0032125. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Institute for Decarbonization and Energy Advancement (UK IDEA) (Recipient) developed an intensified process to capture CO 2 from ambient conditions (415 ppm CO 2 ). The process combines low-temperature solvent-aided membrane capture with electrochemically-mediated solvent regeneration to simultaneously capture ambient CO 2 while regenerating the solvent. The technology employs only two primary units, a regenerator and an absorber/contactor, while generating high purity hydrogen as a co-product that can be sold, used for energy storage, or cost-saving depolarization of the direct air capture (DAC) system during the grid peak demand, allowing for flexible operation. Since the technology is powered directly by DC electricity, it can seamlessly tie in with power sources like solar cells without the need for AC/DC converters, therefore allowing for a remote operation to further mitigate greenhouse gas generation toward deploying a negative carbon emissions technology that is completely decoupled from the carbon emissions from the power source for the DAC unit. The completion of the project results in significant progress toward the Department of Energy’s (DOE’s) goal of advancing lab and bench-scale DAC systems to a sufficient maturity level that can justify their continued scale-up through the verification testing of the electrochemically regenerated solvent system for DAC with co-generation of hydrogen at bench-scale. The technology addressed the complexities of incumbent DAC systems by demonstrating at ambient conditions (1) low gas-side pressure-drop facile CO 2 capture via an intensified membrane absorber with in-situ regenerated hydroxide as capture solvent, (2) multi-functional electrochemical regenerator for hydroxide regeneration, CO 2 concentration and hydrogen production at less than 3 V, and (3) stable DAC performance including >90% capture with air influent at the CFM scale. The data from this project enables the completion of Techno-Economic Analysis (TEA) and Life Cycle Assessment (LCA). TEA and LCA demonstrate the potential of the proposed electrochemical solvent-based process to be a viable DAC option. The analysis did not identify any obvious concern for the bench-scale operation and no apparent barriers to implementing UK IDEA carbon capture and solvent regeneration system at a larger scale.

08 HYDROGEN↗

Long-lived zone-boundary magnons in an antiferromagnet

Antiferromagnetic (AFM) insulators exhibit many desirable features for spintronic applications such as fast dynamics in the THz range and robustness to fluctuating external fields. However, large damping typically associated with THz magnons presents a serious challenge for THz magnonic applications. Here, we report long-lived short-wavelength zone boundary magnons in the honeycomb AFM insulator CoTiO 3 , recently found to host topological magnons. We find that its zone-boundary THz magnons exhibit longer lifetimes than its zone-center magnons. This unusual momentum-dependent long magnon lifetime originates from several factors including the antiferromagnetic order, exchange anisotropy, a finite magnon gap, and magnon band dispersion. Our work suggests that magnon-magnon interaction may not be detrimental to magnon lifetimes and should be included in future searches for topological magnons.

42 ENGINEERING↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{cos θ}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Q ββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at ~4 bar and drift fields of 74 V cm –1 and 118 V cm –1 , respectively. Alpha decays from the 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

Adams, C. [Argonne National Laboratory; NVIDIA] (O↗