Contactless Calorimetry for Levitated Samples

Temperature and specific heat of hot sample measured with pyrometer in proposed experimental technique. Technique intended expecially for contactless calorimetry of such materials as undercooled molten alloys, samples of which must be levitated to prevent contamination and premature crystallization. Contactless calorimetry technique enables data to be taken over entire undercooling temperature range with only one sample. Technique proves valuable in study of undercooling because difference in specific heat between undercooled-liquid and crystalline phases at same temperature provides driving force to convert metastable undercooled phase to stable crystalline phase.

Lee, M. C.

Calorimetry, activity, and micro-FTIR analysis of CO chemisorption, titration, and oxidation on supported Pt

The value of in situ analysis on CO chemisorption, titration and oxidation over supported Pt catalysts using calorimetry, catalytic and micro-FTIR methods is illustrated using silica- and titania-supported samples. Isothermal CO-O and O2-CO titrations have not been widely used on metal surfaces and may be complicated if some oxide supports are reduced by CO titrant. However, they can illuminate the kinetics of CO oxidation on metal/oxide catalysts since during such titrations all O and CO coverages are scanned as a function of time. There are clear advantages in following the rates of the catalyzed CO oxidation via calorimetry and gc-ms simultaneously. At lower temperatures the evidence they provide is complementary. CO oxidation and its catalysis of CO oxidation have been extensively studied with hysteresis and oscillations apparent, and the present results suggest the benefits of a combined approach. Silica support porosity may be important in defining activity-temperature hysteresis. FTIR microspectroscopy reveals the chemical heterogeneity of the catalytic surfaces used; it is interesting that the evidence with regard to the dominant CO surface species and their reactivities with regard to surface oxygen for present oxide-supported Pt are different from those seen on graphite-supported Pt.

Sermon, Paul A.

Quantum Calorimetry

Your opponent's serve was almost perfect, but you vigorously returned it beyond his outstretched racquet to win the point. Now the tennis ball sits wedged in the chain-link fence around the court. What happened to the ball's kinetic energy? It has gone to heat the fence, of course, and you realize that if the fence were quite colder, you might be able to measure that heat and determine just how energetic your swing really was. Calorimetry has been a standard measurement technique since James Joule and Julius von Mayer independently concluded, about 150 years ago, that heat is a form of energy. But only in the past 15 years or so has calorimetry been applied, at millikelvin temperatures, to the measurement of the energy of individual photons and particles with exquisite sensitivity. In this article, we have tried to show that continuing research in low-temperature physics leads to a greater understanding of high-temperature astrophysics. Adaptations of the resulting spectrometers will be useful tool for fields of research beyond astrophysics.

Stahle, Caroline Kilbourne

Enhancing Battery Safety with Fractional Thermal Runaway Calorimetry

Effective thermal management systems, designed to handle the impacts of thermal runaway (TR) and to prevent cell-to-cell propagation, are key to safe operation of lithium-ion (Li-ion) battery assemblies. Critical factors for optimising these systems include the total energy released during a single cell TR event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A unique fractional thermal runaway calorimeter (FTRC), designed to characterise said critical factors, was utilised to examine the TR behaviour of Li-ion cells). Delegates will be provided with an in-depth discussion on what fractional thermal runaway calorimetry is and how it benefits the development of safe and optimised battery assemblies that protect against thermal runaway. Delegates will see calorimetry data associated with a variety of Li-ion cells. Data presented is relevant to any industry that utilises high-energy Li-ion cells in closed environments and has a need to focus on safety.

Walker, William

Development and Application of a Novel Calorimetry Technique for the Study of Lithium-Ion Cell Thermal Runaway

Lithium-ion battery technology is widely used and is attractive due to demonstrated specific energies in the 200-300 W-hr/kg range. The excellent, mass-efficient energy storage capability of lithium-ion batteries has led to their use on many aerospace platforms. However, lithium-ion batteries can exhibit thermal runaway behavior wherein stored electrochemical energy is released rapidly as a result of thermal or mechanical failure, electrochemical abuse, internal or external short circuiting. A single cell undergoing thermal runaway within a battery has the potential to induce thermal runaway in adjacent cells if heat dissipation is not properly managed and can result in a catastrophic failure of the battery. Designing batteries that are resistant to thermal runaway propagation requires an understanding of, not only, total energy yield but also the means by which that energy is liberated from the cell. While Accelerating Rate Calorimetry and other techniques provide total thermal runaway energy yield, they do not provide the fractional breakdown of energy liberated via conduction through the cell casing from that which is vented from the cell as hot gases and effluents. Such data are needed to inform battery thermal design and analysis. To measure the total energy yield, the fraction conducted through the cell casing, and the fraction lost due to gases and effluents, NASA developed Fractional Thermal Runaway Calorimetry (FTRC). Two calorimeters have been developed and demonstrated, the Small-format- and Large-format Fractional Thermal Runaway Calorimeters (S-FTRC and L-FTRC, respectively). The technique has been successfully applied to small- and large-format cells (2.4-3.5 Ah and >100 Ah capacity, respectively) and has given new insights into Li-ion cell thermal runaway. Development of the calorimeters is discussed and results from the initial thermal runaway testing campaigns are presented.

Lithium-Ion Cell

Animal calorimetry- its future

Animal and human calorimetry, human responses to cold skin and to high cortical temperature, human thermoregulator

CALORIMETRY

High Temperature Dielectric Properties and Differential Scanning Calorimetry of Lunar Simulants

To guide development of microwave process technology that could be used during in situ construction on the Moon, we measured the high-temperature basic dielectric properties (εʹ and εʺ) of 17 lunar simulants and related materials. In order to confidently use these data one needs to understand the data’s strengths and weaknesses. Therefore, a goal of this publication is to provide insights into the comparative effects of sample composition, pre-treatments, experimental variables, high temperatures, and other factors on the measured response. The dielectric measurements were performed using the cavity perturbation method over a temperature range between room temperature to 1000 °C, or higher, and provided the real and imaginary components of permittivity at six frequencies. The utility of the original values was limited by the varying density of the pellets used in the measurement. Therefore, all of the εʹ and εʺ measurements at the frequency of 2466 MHz have been scaled to a constant density, 1.75 g/cm 3 . Here the data are presented as graphs chosen to aid analysis within and across simulant groups. To gain additional insight into the processes happening at the elevated temperatures in the dielectric measurements, heat capacity data was obtained using differential scanning calorimetry (DSC) on several of the simulant materials. Our data show that over the frequency range 397 MHz – 2985 MHz a material’s behavior does not greatly change, as compared to the scale of differences observed between lunar mare and highland simulants at high temperatures. For example at 1000 °C, the mare simulant JSC-1A absorbs 10 times more power than the highland simulant NUW-LHT-5M. We observe that as melting temperatures are reached both permittivity and dielectric loss rise non-linearly, helping to explain thermal runaway during microware heating. Our data show that even less than a few weight % of many non-lunar minerals, and the use of mixtures in simulants can affect the dielectric behavior at higher temperatures. A comparison of our results with published dielectric data for Apollo samples and with remote sensing of the Moon supports the conclusion the simulants and lunar material at room temperature have very similar dielectric values.

Differential Scanning Calorimetry

Automatic calorimetry system monitors RF power

Calorimetry system monitors the average power dissipated in a high power RF transmitter. Sensors measure the change in temperature and the flow rate of the coolant, while a multiplier computes the power dissipated in the RF load.

Harness, B. W.