Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AGR 5 6 7 Capsule 1”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Initial Observations from AGR 5/6/7 Capsule 1

The fourth and final irradiation experiment in the Advanced Reactor Technologies (ART) Advanced Gas Reactor (AGR) fuel development and qualification program is designated as AGR-5/6/7. Data collected from the fabrication, irradiation, and post-irradiation examination (PIE) of this tristructural isotropic (TRISO) fuel are intended to serve as the primary data set for the qualification of this fuel for use in high-temperature gas-cooled reactors (INL 2021, Collin 2018b). However, data collected from the three preceding irradiations (i.e., AGR-1, AGR-2, and AGR-3/4) may also be used to supplement data collected from AGR-5/6/7. All components of the AGR-5/6/7 fuel (i.e., UCO kernels, TRISO coatings, and fuel compacts) were produced on an engineering scale at BWXT (Lynchburg, Virginia USA) according to the fuel specification (Marshall 2017). This fuel was irradiated in the northeast flux trap (NEFT) at the Advanced Test Reactor (ATR) at Idaho national Laboratory (INL) from February 16, 2018 to July 22, 2020 (Pham et al. 2021). Measurements in the fission product monitoring system (FPMS) indicated unexpected and significant numbers of failures of TRISO particles in Capsule 1 near the end of the sixth irradiation cycle (ATR Cycle 166A). In the fourth cycle (ATR Cycle 164B) and beyond, the sweep gas flow became very low (presumably from degradation of the capsule gas outlet line via an unidentified mechanism), and the program deliberately isolated Capsule 1 from gas flow periodically. In later cycles, attempts to reestablish any kind of flow in Capsule 1 were unsuccessful. With little or no flow through Capsule 1, FPMS measurements and enumerations of failed particles in Capsule 1 were difficult or impossible as was the ability to control the helium/neon gas mixture used for temperature control. Gas flows and fission gas activity in the effluent gas from the other AGR-5/6/7 capsules were also impacted by the Capsule 1 gas flow issues and the large increase in fission gas released from the Capsule 1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Capsule Leach Station Hardware Qualification - Phase 1

Procedural changes to this document shall be logged and justified using the EQP Change Log below. Typographical errors do not need to be logged, but do require the Lead Engineers initials and date. Each entry shall be numbered (i.e., CN #1) for identification in the left-hand margin of the table. Each entry may include individual or groups of related procedural changes. Changes to the EQP shall made by pen and ink and/or addition of additional pages depending on the extent of the change.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR 5/6/7 Data Qualification Report for ATR Cycles 162B through 168A

This report provides the qualification status of experimental data for the Advanced Gas Reactor (AGR) 5/6/7 fuel irradiation. AGR-5/6/7 was conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) in support of development and qualification of tri-structural isotropic (TRISO) low-enriched fuel for use in high temperature gas-cooled reactors. The objectives of the AGR-5/6/7 experiments are to: (i) irradiate reference-design fuel particles to support fuel qualification, (ii) establish operating margins for the fuel beyond normal operating conditions, and (iii) provide irradiated-fuel performance data and irradiated-fuel samples for post-irradiation examination (PIE) and safety testing. The test train contains five separate capsules that were independently controlled and monitored. Each capsule contains multiple 12.51-mm-long compacts filled with low enriched uranium carbide/oxide (UCO) TRISO fuel particles. The primary objective of the AGR-5/6 test (Capsules 1, 2, 4, and 5) is to verify successful performance of the reference-design fuel under normal operating conditions. The AGR-7 test (Capsule 3) was designed to explore fuel performance at higher temperatures to demonstrate the capability of the fuel to withstand conditions beyond normal operating conditions in support of plant design and licensing. AGR 5/6/7 will also provide irradiated-fuel performance data on fission-gas release from failed particles during irradiation. The AGR-5/6/7 capsules were irradiated in the ATR northeast flux trap location. The experiment began on February 16, 2018 and ended on July 22, 2020, spanning nine ATR cycles over two and a half years. Thus, the AGR-5/6/7 fuel compacts were irradiated for a total of 360.9 effective full power days. The AGR 5/6/7 experiment was able to remain in the reactor core during all three Powered Axial Locator Mechanism (PALM) cycles (163A, 165A, and 167A) without overheating its fuel compacts. This report includes irradiation monitoring data from nine ATR Cycles: 162B, 163A, 164A, 164B, 165A, 166A, 166B, 167A, and 168A, as stored in the Nuclear Data Management and Analysis System (NDMAS). During irradiation, data records consisted of instantaneous measurements recorded every minute and provided by text files automatically every 2 hours. The AGR 5/6/7 data streams addressed in this report include thermocouple (TC) temperatures, sweep gas data (flow rates [capsule inlet, outlet, and downstream at detector], pressure, and moisture content), and Fission Product Monitoring System (FPMS) data (release rates and release to birth rate ratios [R/Bs]) for each of the five capsules. A total of 94,989,908 TC temperature and sweep gas data records were received and processed by NDMAS for AGR 5/6/7 irradiation. Of these records, 41,593,387 (or 43.7% of the total) met data collection and accuracy requirements and are labeled as Qualified. A total of 57,746,693 TC temperature readings were captured from 54 installed TCs. Among them, 10,034,676 TC temperature records (only 17.4%) were Qualified and 47,701,371 TC temperatures (or 82.6%) are Failed due to 48 TC failures (63.5%) and due to missing values (19.1%). To assess performance of the operational TCs, analysis of daily correlations between TCs found no evidence of virtual junction failure for any TCs. Analyses on control charts of TC temperature differences revealed trending in TC readings for TC2, 4, 5, and 13 in Capsule 3, but there is no conclusive indication of TC drift failure that caused those trends. Therefore, TC control charts are not used to disqualify TC data, but only for users’ consideration. For sweep gas flow rates, a total of 31,519,747 gas flow records (84.4%) are Qualified for use for AGR-5/6/7 experiment; 5,723,468 gas flow records (15.4%) are Failed due mostly to missing values; and 74,641 high sweep gas flow rates (0.2 %) are Trend. A large number of Failed missing TC temperature and gas flow values were caused by an error in the data output script that outputted a ‘NULL’ value when values were unchanged. This problem was fixed during the outage of Cycle 166B, which led to a substantially decreased number of missing values during the last three cycles. Nonetheless, a large amount of non-missing data remained because of the high data acquisition frequency (1-minute) and still provided sufficient data to effectively monitor the experiment as designed. For FPMS data, NDMAS received and processed fission product release and R/B data for nine ATR cycles, when ATR core reached full power during AGR 5/6/7 irradiation. These data consist of 110,388 release rate records and 110,388 R/B records for the twelve radionuclides (Kr 85m, Kr 87, Kr 88, Kr 89, Kr 90, Xe 131m, Xe 133, Xe 135, Xe 135m, Xe 137, Xe 138, and Xe 139) for each of the five capsules. Equivalent numbers of uncertainty records associated the release rates and R/B values were provided. To date, qualification status of the FPMS data stored in the NDMAS dat

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗