Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3-He detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]↗

Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications

High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.

36 MATERIALS SCIENCE↗

PSMC Upgrade Development Documentation and Functional Testing

The functional verification consists of verifying that the calibration (a.k.a. gain matching) is accurate and that there is no double pulsing or signal cross talk and interference. The calibration is shown to be satisfactory from the plateau plots on the right. The absence of double pulsing and cross talk can be seen in the time-interval diagram below. Both phenomena are manifested by spikes in the time interval distribution around 1µs to 5µs. No such spike is present.

3-He detector electronics↗

A New Search for Low-mass Dark Matter and an Examination and Reduction of the Uncertainty due to the Photoelectric Absorption Cross Section using a Cryogenic Silicon Detector with Single-charge Sensitivity

Many astrophysical observations point to the abundant existence of dark matter (DM) in the universe composed of particles beyond the Standard Model. However despite numerous experiments using different techniques, DM particles have yet to be directly observed. The Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB experiment will employ silicon and germanium crystal detectors operated at temperatures as low as 15~mK to probe DM interactions using phonon and ionization signals. Recently, R\&D; facilities have developed gram-sized high-voltage eV-scale (HVeV) silicon detectors that achieve single-electron-hole-pair resolution. By probing effective DM-electron interactions, these devices can be used for searches of low-mass DM candidates.This dissertation presents a DM search experiment known as HVeV Run~2 that employs a second-generation HVeV detector operated in an above-ground laboratory at Northwestern University (IL, USA). Energy spectra are obtained from a blind analysis with 0.39 and 1.2\,g-days of exposure with the detector biased at 60 and 100\,V, respectively. The 0.93~gram detector achieves a 3\,eV phonon energy resolution, corresponding to a world-leading charge resolution of 3\,\% of a single electron-hole pair for a detector bias of 100\,V. With charge carrier trapping and impact ionization effects incorporated into the DM signal models, the resulting exclusion limits are reported for inelastic DM-electron scattering for DM masses from 0.5--$10^{4}$\,MeV$/c^{2}$; in the mass range from 1.2--50\,eV$/c^{2}$ the limits for dark photon and axion-like particle absorption are reported.Several DM search experiments, including HVeV Run~2, are sensitive to low-mass DM candidates that rely on the temperature-dependent photoelectric absorption cross section of silicon. However discrepancies in the underlying literature data result in dominating systematic uncertainties on the DM exclusion limits. In order to reduce these systematic uncertainties, this dissertation presents a novel method of making a direct, low-temperature measurement of the photoelectric absorption cross section of silicon at energies near the band gap (1.2--2.8\,eV).

Wilson, Matthew James↗

Overview of Collaborative Research Between UNICAMP in Brazil and Fermilab in Cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N2) absorption of LAr scintillation light, known as quenching, necessitates N2 contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N2, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N2 contamination. Brazil State University of Campinas's (UNICAMP) contribution to LBNF focuses on developing argon purification and regeneration for DUNE FD-1 and FD-2. To that effect, they constructed a test facility to perform studies on LAr purification at a smaller scale, the Purification Liquid Argon Cryostat (PuLArC) with approximately 90 liters of LAr. One of the filtration materials was considered and tested Li-FAU molecular sieve. Value engineering on argon purification media was conducted, leading to the identification of Li-FAU zeolite's ability to effectively capture N2 impurities during LAr circulation. Testing at UNICAMP's PuLArC facility demonstrated that 1 kg of Li-FAU is capable of reducing N2 contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours of circulation. In October 2023, testing at the Iceberg cryostat in Fermilab's Noble Liquid Test Facility (NLTF), with approximately 2,625 liters of LAr, confirmed the efficacy of 3 kg of Li-FAU in reducing N2 contamination from ~ 5 ppm of injected N2 down to less than 1 ppm over 96-hour cycles, showcasing its potential for larger-scale LAr cryostats. Further tests are planned to validate Li-FAU's use as a possible alternative to Molecular Sieve 4A in LBNF-DUNE and related liquid argon experiments. This contribution will describe how the research was performed and present the test setups and results in detail. This advancement not only has the potential to enhance DUNE's precision but also to elevate liquid argon experiments globally, showcasing the power of international scientific collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of collaborative research between UNICAMP in Brazil and Fermilab in cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N$_2$) absorption of LAr scintillation light, known as quenching, necessitates N$_2$ contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N$_2$, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N$_2$ contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dopants, Isotope, Pressure and Lead Sequestration for Hybrid Perovskite Materials

Dopants, Isotope, Pressure and Lead Sequestration for Hybrid Perovskite Materials The soaring power conversion efficiency (PCE) of solution process-based organic-inorganic hybrid perovskites solar cells (PSCs) assures their membership in the competitive photovoltaic technologies. However, stability, toxicity and scalability are the three grand challenges that still impedes the market adoption of PSCs. Careful fundamental studies on how their fascinating optoelectronic properties is related to their structures may provide leads to these challenges and also spin off new applications. In this talk, I will present our recent study on the dopants, isotope and pressure effects on hybrid perovskite materials (HPMs). We discovered an interesting bipolar electron injection in LiCl-doped MAPbI 3 -based UV detectors that respond to the energy of UV photons in distinguished photocurrents polarity. We also investigated how the underline interaction between the mass of the cationic rotors and the inorganic lattice in HPMs by isotope effect. In-situ synchrotron X-ray and time-resolved photoluminescence revealed abnormal optoelectronic properties of HPMs by modulating their bond angles and bond lengths using high pressure techniques. Moreover, I will also discuss our new technology to sequestrate lead leakage on perovskite solar cells that can absorb >99% leaked Pb ions under severe device damge while without sacrificing the PCE under normal operational conditions.

Xu, Tao↗

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σ ¯ e is constrained for dark matter masses from 0.5 to 10 4 MeV / c 2 ; in the mass range from 1.2 to 50 eV / c 2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant g a e are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σ ¯ e = 8.7 × 10 - 34 cm 2 , ϵ = 3.3 × 10 - 14 , and g a e = 1.0 × 10 - 9 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of astrophysical neutrinos at prospective locations of dark matter detectors

We study the prospects for detection of solar, atmospheric neutrino, and diffuse supernova neutrino background (DSNB) fluxes at future large-scale dark matter detectors through both electron and nuclear recoils. We specifically examine how the detection prospects change for several prospective detector locations [Sanford Underground Research Facility (SURF), SNOlab, Gran Sasso, China Jinping Underground Laboratory (CJPL), and Kamioka] and improve upon the statistical methodologies used in previous studies. Because of its ability to measure lower neutrino energies than other locations, we find that the best prospects for the atmospheric neutrino flux are at the SURF location, while the prospects are weakest at CJPL because it is restricted to higher neutrino energies. On the contrary, the prospects for the DSNB are best at CJPL, due largely to the reduced atmospheric neutrino background at this location. Including full detector resolution and efficiency models, the CNO component of the solar flux is detectable via the electron recoil channel with exposures of ∼ 10 3 ton-yr for all locations. These results highlight the benefits for employing two detector locations, one at high and one at low latitude. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Heavy neutral leptons at beam dump experiments of future lepton colliders

A new beam dump experiment that utilizes the beam of future high energy electron-positron colliders could be an excellent avenue to search for dark sector particles due to its unprecedented high energy and intensity. We consider heavy neutral leptons (HNLs) as a specific example to demonstrate the sensitivity of searches for dark sector particles at future electron-positron collider beam dump experiments. This includes the study of the reach at the International Linear Collider (ILC), the Cool Copper Collider (C 3 ), and the Compact Linear Collider (CLIC). We comprehensively examine the HNL production and detector acceptance at these electron beam dump experiments. We show that these experiments will probe regions of HNL parameter space, not yet probed by past experiments, as well as by future approved experiments. Our study also motivates a more detailed analysis of heavy meson productions in high-energy electron-nucleon collisions in thick targets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Geant4 Simulation of Cherenkov Photons in Perovskite CsPbBr 3 Gamma-Ray Detectors

Perovskite materials have recently attracted significant attention for hard X-ray and gamma-ray detection. Cherenkov light generated by fast electrons due to gamma-ray interaction with the material can be used to provide fast timing information. Here, in this study, we report Geant4 simulation results of Cherenkov photon generation, transport, and detection within perovskite CsPbBr3. The Cherenkov photon yield, energy spectrum and temporal distribution are investigated under different gamma-ray energy deposition within CsPbBr3. CsPbBr 3 has a similar Cherenkov photon yield as of TlBr that has demonstrated fast-timing capability based on Cherenkov light. The effect of crystal volume, surface finish and SiPM photon detection efficiency on the Cherenkov detection is also discussed. This work provides insights into Cherenkov processes of CsPbBr3.

Cherenkov photon↗

Investigation of defects in melt and solution grown perovskite CsPbBr 3 single crystals

Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr 3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr 3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 10 11 to 1 × 10 16 cm –3 . Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 10 14 cm –3 . The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. Finally, for an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 10 11 cm –3 .

36 MATERIALS SCIENCE↗

Quantitative spatiotemporal density evolution of aluminum heated purely by monochromatic electrons

A spatially resolved air-wedge shearing interferometer and shadowgraph diagnostic provides measurements of electron density with a resolution of ∼40 μm. A ∼100-ns-long, monoenergetic electron bunch at 19.8 MeV and a current of 1.4 kA (8.5×1014 e−) heats 100-μm-thick aluminum (Al) foils in a 1-mm-spot to Te∼1 eV. A 5-ns-long, ∼60 mJ, frequency doubled Nd:YAG laser probes the dense Al plasma. Electron densities up to 1020cm−3 are resolved; the maximum resolvable density is limited by opacity, transmission, and spatial fringe density achievable with the detector. This diagnostic provides measurements of the total phase shift, transmission, and electron density. Several measurements at different time slices provide the ability to determine the velocity of the leading edge of the shadowgraph and compare it to the motion of different density shells. These measurements are also compared to radiation hydrodynamics simulations. A rough quantitative agreement is shown between the hydro simulations and the measurements; there are differences in the exact density distributions.

Coleman, J. E. (ORCID:0000000308873757)↗

Inorganic Halide Perovskitoid TlPbI 3 for Ionizing Radiation Detection

Room temperature semiconductor detector (RTSD) materials for γ-ray and X-ray radiation are in great demand for the nonproliferation of nuclear materials as well as for biomedical imaging applications. Halide perovskites have attracted great attention as emerging and promising RTSD materials. In this contribution, the material synthesis, purification, crystal growth, crystal structure, photoluminescence properties, ionizing radiation detection performance, and electronic structure of the inorganic halide perovskitoid compound TlPbI 3 are reported on. This compound crystallizes in the ABX 3 non-perovskite crystal structure with a high density of d = 6.488 g·cm –3 , has a wide bandgap of 2.25 eV, and melts congruently at a low temperature of 360 °C without phase transitions, which allows for facile growth of high quality crystals with few thermally-activated defects. High-quality TlPbI 3 single crystals of centimeter-size are grown using the vertical Bridgman method using purified raw materials. A high electrical resistivity of ≈10 12 Ω·cm is readily obtainable, and detectors made of TlPbI 3 single crystals are highly photoresponsive to Ag K α X-rays (22.4 keV), and detects 122 keV γ-rays from 57 Co radiation source. The electron mobility-lifetime product µ e τ e was estimated at 1.8 × 10 –5 cm 2 ·V –1 . A high relative static dielectric constant of 35.0 indicates strong capability in screening carrier scattering and charged defects in TlPbI 3 .

36 MATERIALS SCIENCE↗

Developing a GUI for the Robotic Test Stand

The introduction of this poster explains the technology behind DUNE’s far and near detectors and how passing neutrinos generate electrons that drift into a wire grid. I then explain how 3 ASICs manage signals received from electron interception. Next, the poster states how COLDATA chips are undergoing quality control by a Robotic Test Stand using a state machine. I further explained how earlier tests were done via a command line script and the necessity to implement a user-friendly Graphical User Interface with new features a command line can’t implement. For the implementation section, tools and methods for implementation are listed such as Python, tkinter, and GitHub as well as how multithreading and queue implementation was necessary for GUI functionality. Then, I elaborated on the GUIs new features. Finally, I explain how the GUI will be distributed across multiple institutions and future changes planned for the GUI. Photos of the RTS, far detector cave, diagram of anode assembly plane, COLDATA chips, set up tab, result tab, and legacy command line interface are shown.

Gutierrez Villanueva, Jaziel [DuPage Coll.]↗

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/\mu}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/\mu}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$\pi$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discriminator Threshold Study for Scint 1

During electronics testing at NSRL, the fluence/spill is recorded from the QC1 chamber. This chamber, which is a permanent fixture on the NSRL beamline, requires calibration from an external radiation detector that can measure ion flux directly. A 1.0 × 1.0 × 0.5 cm 3 scintillator is used at the testing location to calibrate all NSRL beams for electronic experiments. A calibration factor is derived by comparing the ions observed by the scintillator and QC1 during an exposure of at least 10 5 scintillator counts or total ions.

43 PARTICLE ACCELERATORS↗