Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “robotics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Hopper on wheels: evolving the hopping robot concept

This paper describes the evolution of our concept of hopping robot for planetary exploration, that combines coarse long range mobility achieved by hopping, with short range wheeled mobility for precision target acquisition.

planetary exploration planetary robots nanorover h↗

Health Cars Robotics: A Progress Report

This paper describes the approach followed in the design of a service robot for health care applications. This paper describes the architecture of the subsystem, the features of the manipulator arm, and the operator interface.

service robot robotics manipulator armoperator int↗

Test and Validation of the Mars Science Laboratory Robotic Arm

The Mars Science Laboratory Robotic Arm (RA) is a key component for achieving the primary scientific goals of the mission. The RA supports sample acquisition by precisely positioning a scoop above loose regolith or accurately preloading a percussive drill on Martian rocks or rover-mounted organic check materials. It assists sample processing by orienting a sample processing unit called CHIMRA through a series of gravity-relative orientations and sample delivery by positioning the sample portion door above an instrument inlet or the observation tray. In addition the RA facilitates contact science by accurately positioning the dust removal tool, Alpha Particle X-Ray Spectrometer (APXS) and the Mars Hand Lens Imager (MAHLI) relative to surface targets. In order to fulfill these seemingly disparate science objectives the RA must satisfy a variety of accuracy and performance requirements. This paper describes the necessary arm requirement specification and the test campaign to demonstrate these requirements were satisfied.

manipulation↗

Firing Room Remote Application Software Development & Swamp Works Laboratory Robot Software Development

The National Aeronautics and Space Administration (NASA) is creating a way to send humans beyond low Earth orbit, and later to Mars. Kennedy Space Center (KSC) is working to make this possible by developing a Spaceport Command and Control System (SCCS) which will allow the launch of Space Launch System (SLS). This paper's focus is on the work performed by the author in her first and second part of the internship as a remote application software developer. During the first part of her internship, the author worked on the SCCS's software application layer by assisting multiple ground subsystems teams including Launch Accessories (LACC) and Environmental Control System (ECS) on the design, development, integration, and testing of remote control software applications. Then, on the second part of the internship, the author worked on the development of robot software at the Swamp Works Laboratory which is a research and technology development group which focuses on inventing new technology to help future In-Situ Resource Utilization (ISRU) missions.

Gazebo (Robot simulator)↗

Robotic Refueling Mission-3 An Overview

Robotic Refueling Mission-3 (RRM3) is an external payload on the International Space Station (ISS) to demonstrate the techniques for storing and transferring a cryogenic fuel on orbit. RRM3 was designed and built at the National Aeronautics and Space Administration/Goddard Space Flight Center (NASA/GSFC). Initial testing was performed at GSFC using liquid nitrogen and liquid argon. Final testing and flight fill of methane was performed at the NASA Kennedy Space Center (KSC) to take advantage of KSC's facilities and expertise for handling a combustible cryogen.

Robotic Transfer↗

A Fault-Tolerant Intelligent Robotic Control System

This research project involves development of path planning and graphical user interface software at an operator workstation and a manipulator control system which translates the commands from the user workstation to control the robot arm.

path↗

Innovation in Space Robotics

Overview of NASA's strategy for developing space robotics technology, including examples of tech transfer and open source. Presentation also includes summary of different ways to work with NASA.

space robotics↗

Demoing the Modified TALON Robot

A technician at Idaho National Laboratory demonstrates the modified TALON robot.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robotics

Mark Buckner wants to help machines see objects the way humans do, and he's also mentoring the next generation of scientists and engineers through FIRST Robotics.

42 ENGINEERING↗

Optimizing Perovskite Thin‐Film Parameter Spaces with Machine Learning‐Guided Robotic Platform for High‐Performance Perovskite Solar Cells

Abstract Simultaneously optimizing the processing parameters of functional thin films remains a challenge. The design and utilization of a fully automated platform called SPINBOT is presented for the engineering of solution‐processed functional thin films. The SPINBOT is capable of performing experiments with high sampling variability through the unsupervised processing of hundreds of substrates with exceptional experimental control. Through the iterative optimization process enabled by the Bayesian optimization (BO) algorithm, the SPINBOT explores an intricate parameter space, continuously improving the quality and reproducibility of the produced thin films. This machine learning (ML)‐guided reliable SPINBOT platform enables the acceleration of the optimization process of perovskite solar cells via a simple photoluminescence characterization of films. As a result, this study arrives at an optimal film that, when processed into a solar cell in an ambient atmosphere, immediately yields a champion power conversion efficiency (PCE) of 21.6% with satisfactory performance reproducibility. The unsealed devices retain 90% of their initial efficiency after 1100 h of continuous operation at 60–65 °C under metal‐halide lamps. It is anticipated that the integration of robotic platforms with the intelligent algorithm will facilitate the widespread adoption of effective autonomous experimentation to address the evolving needs and constraints within the materials science research community.

14 SOLAR ENERGY↗

Dynamic analysis of fully constrained Cable-Driven Parallel Robots for automated prefabricated component installation

This paper presents a dynamic analysis and validation framework to assess a fully constrained six-anchor Cable-Driven Parallel Robot (CDPR) for automated installation of prefabricated facade components. Compared with conventional eight-anchor systems, the six-anchor configuration simplifies setup and reduces cost, but it also reduces control authority, shrinks the wrench-feasible workspace, and tightens orientation limits. Consequently, it is unclear a priori whether dynamically feasible trajectories exist to move the end effector from pickup to the facade. A constrained trajectory optimization is formulated to enforce the system dynamics, cable-tension bounds, and pose/velocity limits, and the framework is evaluated in simulation at three levels: (i) an idealized reference model, (ii) a lab-scale prototype model incorporating measured anchor misalignments and identified damping, and (iii) a full-scale three-story building model with load decomposition for structural feasibility checks. Across these scenarios, the analysis shows that optimal, constraint-satisfying trajectories exist that move the end effector from pickup to installation while maintaining a near-plumb, level orientation at the final pose. Collectively, this multi-scale dynamic analysis and validation framework supports the deployment readiness of the six-anchor CDPR and provides a prototype-based sensitivity case study of how measured anchor placement deviations affect feasibility.

CDPR↗

3D Curves With a Prescribed Curvature and Torsion for a Flying Robot

The objective of this paper is to generate a desired flight path to be followed by an flying robot. A curve with discontinuous curvature and torsion is not appropriate for smooth motions for any vehicle architecture. Three different classes of curves are presented. First, constant curvature and torsion followed by a linear variation versus the curvilinear abscissa then a quadratic variation. Finally, the problem of maneuvers between two trim helices of different curvature and torsion is tackled with.

42 ENGINEERING↗

Performance of a Motion Tracking System During Cyberknife Robotic Radiosurgery

Cyberknife (Accuracy Inc., Ca) is a robotic radio-surgery system that includes a compact 6 MV linac delivering up to 800 cGy per minute, and an automate arm to aim at any part of the body from any angle. An essential tool is the guidance system based on x-ray imaging cameras located on supports around the patient. A Cyberknife system has been operational at the Vicenza (Italy) Hospital for years and is mainly employed for treating benign and malignant tumors, and Arterior-Venous Malformations. In radiation therapy, delivery of high doses to targets that move with respiration is challenging because of possible spatial inaccuracies. The purpose of this work was to estimate the accuracy of the prediction algorithm used to compensate for system latency in a real-time respiratory tracking system. We have analyzed respiratory signals of 30 patients who had lung or liver Cyberknife treatments. The 'Synchrony'(Accuracy Inc.) motion tracking system we use is based on the correlation between the position of LED markers, detected in real time, and the position of internal markers, sampled through x-ray imaging. The position of the external LED signals, though read in real time, must be predicted to compensate for a few hundred ms time lag in the feedback loop that redirects the beam to the current target position. The respiratory signals were described by employing their frequency power spectrum, as recently proposed by other authors. Prediction errors above 1.5 mm, lasting for periods longer than 5 seconds were observed for irregular breathers. These episodes correlate to the presence of a bimodal distribution in the power spectral density, and of very low frequencies contribution. A more refined approach would include a personalized choice of the prediction algorithm based on the very first minutes of treatment. Patient training aimed at reducing breathing irregularities might also result in improved spatial accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗