Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Deposit high purity Alumnium on Nb in support of conduction cooled SRF cavities

The project will demonstrate a potential manufacturing method that could result in a means to operate superconducting radio frequency (SRF) cavities without liquid cryogens. The technical approach sought to apply high-purity (99.999%) aluminum to cavity-grade niobium components via a new and proprietary electron-beam additive manufacturing technique contributed by PAVAC. High thermal conductivity of the aluminum could enable a cryocooler, which is a compact electrically powered refrigeration device, to extract sufficient heat for operating the cavity for a variety of applications. Trial coatings of niobium components were to be evaluated for metallurgy, mechanical bonding, and thermal and electrical conductivity using superconducting materials characterization facilities at Fermilab. The results of the characterization were intended to provide process feedback and optimization to PAVAC. During the project, PAVAC completed one set of samples. However, due to a business reorganization, PAVAC choose not to proceed toward a second set of samples using their proprietary approach. The PAVAC technical goal was replaced by a Fermilab goal to determine whether high-purity aluminum could be attached to niobium by a system of welded stud anchors and fasteners. The project pivoted to evaluations of trial stud welded anchors using infrastructure and expertise similar to that applied to the PAVAC applied coatings.

43 PARTICLE ACCELERATORS↗

Improved Performance of Cu(InGa)(SeS) 2 PV Modules Using the Reaction of Metal Precursors. Final Report

This project “Improved Performance of Cu(InGa)(SeS) 2 PV Modules using the Reaction of Metal Precursors” was a partnership led by the Institute of Energy Conversion (IEC) at the University of Delaware with Columbia University and the Molecular Foundry at the Lawrence Berkeley National Laboratory. The aim was to develop pathways to improve Cu(InGa)(SeS) 2 (CIGSS) thin film photovoltaic modules using processes compatible with low manufacturing cost. The CIGSS approach investigated was a two-step process including deposition of metal precursor films following by reaction in hydride gases utilizing IEC’s novel reactor. The process was similar to that under commercial development by the project’s industry partner Stion. When Stion went out of business mid-project the focus changed to a rapid thermal process considered more commercially viable. Approaches to improve the performance of solar cells using the reacted films focused on two material innovations. First, the overall Ga content was increased to increase the operating voltage, which is desirable for scale-up to commercial modules. Second, the processing and performance advantages arising from Ag alloying were investigated. Advanced characterization guided process and material development including control of relative composition gradients. Research on the formation of Cu-Ga-In metal precursors utilized sputtering deposition which is normally used in commercial applications. The work resulted in processes for deposition of precursor stacks with increased relative Ga content and effects of deposition parameters on morphology and phase composition were established. It was shown that the metal precursor films have comparable phase composition and morphology so subsequent reaction follows from the same starting point. The addition of Ag to the metal precursors gave more uniform morphology and improved adhesion of reacted films which enable higher reaction temperature for faster processing. A novel outcome was the discovery of a previously undocumented material phase in sputter-deposited and evaporated Ag-Cu-In-Ga thin films. Hydride gas reaction processes including time-temperature-concentration profiles were developed for different precursor compositions. This enables control of composition profiles to engineer through-film gradients for solar cell optimization with characterization and simulations used to correlate measured film composition profiles to measurements of devices. In particular, the gradient of sulfur at the front of the CIGSS film was found to be critical. The simulations guided process development leading to improved reproducibility of devices improved performance with higher Ga content and higher voltage. With Ag-alloyed precursors, the reaction pathways leading were determined. A significant finding was that Ag-alloying increases the reaction rate to completely convert precursor films to the final chalcopyrite which could enable reduced reaction time to benefit manufacturability. To maintain potential commercial viability, the process under investigation was refocused to a rapid thermal process that could potentially be incorporated into an in-line process for manufacturing. Precursors with different composition were capped with an extra selenium layer and reacted in hydrogen sulfide 5-15 minutes, compared to typically 2 hours in the previous multi-step batch process. Critical RTP parameters were identified to control the reaction. Further optimization would be needed for high efficiency solar cells but pathways to high quality devices with further optimization and improved heating uniformity were developed. The project also developed new optoelectronic characterization approaches with a focus on development and application of spatial- and time-resolved photoluminescence and a custom mapping photoluminescence microscope built. It was shown how critical electronic transport properties strongly depend on the chemical composition of the material and that a wide range of samples show inhomogeneity on a length scale larger than the grains in the films. Additionally, two-photon excitation capability was developed to distinguish bulk vs surface losses. The project advances the state-of-the -art for precursor reaction processes in several ways that could impact manufacturing. This includes validation of approaches to increase voltage and establishment of model-guided control to form optimal composition profiles. The application of process control approaches with knowledge of phase formation and reaction pathways can be critically valuable in designing a large-scale process.

14 SOLAR ENERGY↗

High Throughput Genome Releaser

In this study, we present the development of a High Throughput Genome Releaser, an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed for rapid, cost-effective, and efficient DNA extraction, optimized for subsequent PCR reactions. Our experimentation with various synthetic materials led us to select a particular type of plastic that mirrors the properties of glass cover slides, providing a smooth surface and effective compression capabilities. We engineered a 96-well device equipped with a 96-well plate and a top rod, operable both manually and automatically, which is compatible with widely used liquid-handling robot decks. This compatibility enhances ease of use in high-throughput PCR setups. Additionally, we developed software to support its automatic functions. The genome releaser facilitates the extraction of PCR-amplifiable genomic DNA from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells. This versatility could significantly advance biomanufacturing processes.

42 ENGINEERING↗

Development of an accelerator-based diagnostic for plasma-facing surfaces in magnetic confinement devices

The focus of this work was the development of the Accelerator-based In-situ Material Surveillance (AIMS) diagnostic. The understanding of plasma-material interaction processes in fusion devices has been greatly hampered by the lack of ability to measure the surface ~micron layers of solid surfaces that are in contact with and greatly modified by the boundary fusion plasma. AIMS was the first diagnostic developed and deployed that allowed non-destructive surface measurements with adequate spatial and time resolution. The deployment was primarily carried out on the Alcator C-Mod tokamak. AIMS diagnostic goal is to remotely generate isotopic concentration maps on a plasma shot-to-shot timescale that cover a large fraction of the plasma-facing surface inside of a magnetic fusion device without the need for vacuum breaks or physical access to the material surfaces. The diagnostic used a compact (~ 1 m), high-current (~ 1 milliamp) radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak. The tokamak magnetic fields were controlled – in between plasma shots – to steer the deuterons to material surfaces where the deuterons cause high-Q nuclear reactions with low-Z isotopes up to 5 microns into the material. The induced neutrons and gamma rays are measured with scintillation detectors; energy spectra analysis provides quantitative reconstruction of surface compositions. Experimental validation showed that low-Z isotopes such as deuterium and boron can be quantified on the material surfaces, and that magnetic steering provides access to different measurement locations. AIMS measurements of D retention on inner wall PFCs were acquired during diverted and limited plasma operations and during wall conditioning experiments om Alcator C-Mod. Intershot measurements demonstrate the local erosion and co-deposition of boron films on PFC surfaces with a constant D-B ratio. This is consistent with previous results suggesting that D co-=deposition with boron is insufficient to account for the net retention observed in Alcator C-Mod. Changes in deuterium concentration during boronization, electron cyclotron and glow cleanings were also measured. These initial results were limited to studying low-Z surface properties, because the Coulomb barrier precludes nuclear reactions between high-Z elements and the ~1 MeV AIMS deuteron beam. In order to measure the high-Z erosion of interest in Alcator C-Mod and future fusion devices, a new technique using deuteron-induced gamma emission and a low-Z depth marker was developed using implanted depth markers as a method of measuring bulk erosion and redeposition. This method is dubbed DEA: Depth marker Erosion with AIMS. DEA simulations and experiments were used to validate this technique, both in the laboratory and via experiments in the EAST tokamak. Based on these results, the DEA technique, using ion beam implanted depth markers as a reference to the surface in order to monitor surfaces for erosion and redeposition, is a viable option as a diagnostic, both in and ex situ. These markers show stability to temperature, the tokamak environment, and multiple probing beams. The ex-situ (eDEA) method, which uses resonances in the cross sections of gamma producing reactions to track the surface, was used to successfully measure erosion in samples that were exposed in the EAST tokamak. The in-situ (iDEA) method, which uses the gamma yield ratio to monitor changes to the surface, was used to differentiate between markers implanted to different depths. Both techniques were successfully simulated, and both presented unique challenges experimentally and in data analysis. In particular, the eDEA probing beam was found to have energy variations leading to initial experimental uncertainty, and the iDEA gamma spectra had conflicting gamma peaks which make data analysis difficult. However, the end result is a promising framework for a diagnostic technique that supplements the abilities of AIMS and expands the possibilities of surface diagnostics in fusion devices. While the results of this work are overwhelmingly encouraging for further development of AIMS in general, and the DEA technique specifically, several areas require significant development before this diagnostic is as robust and widely applicable as a surface diagnostic ought to be. Recommended future work includes the development of a cross section/yield measurement database, erosion tests with secondary verification of results using a fiducial mark from a focused ion beam, and acquiring a new accelerator with a more reliable high energy proton and deuterium beam The project resulted in 14 publications, including the PhD theses of three MIT graduate students, cited in the included bibliography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Localized Excitons in NbSe 2 -MoSe 2 Heterostructures

Neutral and charged excitons (trions) in atomically thin materials offer important capabilities for photonics, from ultrafast photodetectors to highly efficient light-emitting diodes and lasers. Recent studies of van der Waals (vdW) heterostructures comprised of dissimilar monolayer materials have uncovered a wealth of optical phenomena that are predominantly governed by interlayer interactions. Here, we examine the optical properties in NbSe 2 -MoSe 2 vdW hetero- structures, which provide an important model system to study metal–semiconductor interfaces, a common element in optoelectronics. Through low-temperature photoluminescence (PL) microscopy, we discover a sharp emission feature, L1, that is localized at the NbSe 2 -capped regions of MoSe 2 . L1 is observed at energies below the commonly studied MoSe 2 excitons and trions and exhibits temperature- and power-dependent PL consistent with exciton localization in a confining potential. This PL feature is robust, observed in a variety of samples fabricated with different stacking geometries and cleaning procedures. Using first-principles calculations, we reveal that the confinement potential required for exciton localization naturally arises from the in-plane band bending due to the changes in the electron affinity between pristine MoSe 2 and NbSe 2 -MoSe 2 heterostructure. Here, we discuss the implications of our studies for atomically thin optoelectronics devices with atomically sharp interfaces and tunable electronic structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High frequency alternating current chip nano calorimeter with laser heating

Heat capacity spectroscopy at frequencies up to 100 kHz is commonly performed by thermal effusivity measurements applying the 3ω-technique. Here we show that AC-calorimetry using a thin film chip sensor allows for the measurement of frequency dependent heat capacity in the thin film limit up to about 1 MHz. Using films thinner than the thermal length of the thermal wave (∼1 μm) at such frequencies is advantageous because it provides heat capacity alone and not in combination with other quantities like thermal conductivity, at least on a qualitative basis. The used calorimetric sensor and the sample are each less than 1 μm thick. For high frequency AC-calorimetry, high cooling rates at very small temperature differences are required. This is realized by minimizing the heated spot to the size of the on chip thermocouple (3 × 6 μm{sup 2}). A modulated laser beam shaped and positioned by a glass fiber is used as the heat source. The device was used to measure the complex heat capacity in the vicinity of the dynamic glass transition (structural relaxation) of poly(methyl methacrylate). Combining different calorimeters finally provides data between 10{sup −3} Hz and 10{sup 6} Hz. In this frequency range the dynamic glass transition shifts about 120 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond laser excitation of multiple spin waves and composition dependence of Gilbert damping in full-Heusler Co{sub 2}Fe{sub 1−x}Mn{sub x}Al films

Spin-wave dynamics in 30 nm thick Co{sub 2}Fe{sub 1−x}Mn{sub x}Al full-Heusler films is investigated using time-resolved magneto-optical polar Kerr spectroscopy under an external field perpendicular to films. Damon-Eshbach (DE) and the first-order perpendicular standing spin-wave (PSSW) modes are observed simultaneously in four samples with x = 0, 0.3, 0.7, and 1. The frequency of DE and PSSW modes does not apparently depend on composition x, but damping of DE mode significantly on x and reaches the minimum as x = 0.7. The efficient coherent excitation of DE spin wave exhibits the promising application of Co{sub 2}Fe{sub 0.3}Mn{sub 0.7}Al films in magnonic devices.

36 MATERIALS SCIENCE↗

GaAs buffer layer technique for vertical nanowire growth on Si substrate

Gold catalyzed vapor-liquid-solid method is widely applied to III–V nanowire (NW) growth on Si substrate. However, the easy oxidation of Si, possible Si contamination in the NWs, high defect density in the NWs, and high sensitivity of the NW morphology to growth conditions largely limit its controllability. In this work, we developed a buffer layer technique by introducing a GaAs thin film with predefined polarity as a template. It is found that samples grown on these buffer layers all have high vertical NW yields in general, due to the single-orientation of the buffer layers. Low temperature buffer with smoother surface leads to highest yield of vertical NWs, while high temperature (HT) buffer with better crystallinity results in perfect NW quality. The defect-free property we observed here is very promising for optoelectronic device applications based on GaAs NW. Moreover, the buffer layers can eliminate Si contamination by preventing Si-Au alloy formation and by increasing the thickness of the Si diffusion barrier, thus providing more flexibility to vertical NW growth. The buffer layer technique we demonstrated here could be easily extended to other III-V on Si system for electronic and photonic applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma jet printing for flexible substrates

Recent interest in flexible electronics and wearable devices has created a demand for fast and highly repeatable printing processes suitable for device manufacturing. Robust printing technology is critical for the integration of sensors and other devices on flexible substrates such as paper and textile. An atmospheric pressure plasma-based printing process has been developed to deposit different types of nanomaterials on flexible substrates. Multiwalled carbon nanotubes were deposited on paper to demonstrate site-selective deposition as well as direct printing without any type of patterning. Plasma-printed nanotubes were compared with non-plasma-printed samples under similar gas flow and other experimental conditions and found to be denser with higher conductivity. The utility of the nanotubes on the paper substrate as a biosensor and chemical sensor was demonstrated by the detection of dopamine, a neurotransmitter, and ammonia, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting (SC) circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in SC films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu–Shiba–Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

metal/substrate interlayer↗

Interaction between magnetic moments and itinerant carriers in $d^0$ ferromagnetic SiC

Elucidating the interaction between magnetic moments and itinerant carriers is an important step to spintronic applications. In this work, we investigate magnetic and transport properties in d0 ferromagnetic SiC single crystals prepared by postimplantation pulsed laser annealing. Magnetic moments are contributed by the p states of carbon atoms, but their magnetic circular dichroism is different from that in semi-insulating SiC samples. The anomalous Hall effect and negative magnetoresistance indicate the influence of d 0 spin order on free carriers. The ferromagnetism is relatively weak in N-implanted SiC compared with that in Al-implanted SiC after annealing. The results suggest that d 0 magnetic moments and itinerant carriers can interact with each other, which will facilitate the development of SiC spintronic devices with d 0 ferromagnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization and differentiation of aluminum powders used in improvised explosive devices – Part 1: Proof of concept of the utility of particle micromorphometry

Abstract Aluminum (Al) powders are commonly used in improvised explosive devices as metallic fuels, a component of explosive mixtures. These powders can be obtained readily from industrial‐scale and consumer products, and produced using unsophisticated “kitchen chemistry” techniques. This research demonstrates the potential of automated particle micromorphometry for comparisons between known source and questioned Al powders recovered from IEDs, as well as for insight into the method of Al powder manufacture. Al powder samples were obtained from legitimate manufacturers, and 56 samples were produced “in‐house” from Al‐containing spray paints and ball‐milled Al foils. Transmitted light microscope images of Al powder particles were acquired using an automated stage with automated z‐focus; 17 size and shape parameters were measured for all particles. Approximately 37,000–2,500,000 particles/sample were analyzed using an open‐source statistical package with customized code. Dimensionality reduction was required for processing the large datasets: eight of the 17 measured variables were selected based on inspection of the correlation matrix. Data from four subsamples from each of the 56 samples produced using “in‐house” methods were analyzed using ANOVA to assess the within‐ and between‐sample variation. High within‐sample variation was noted; however, ANOVA and post‐hoc Tukey's honestly significant difference (HSD) tests demonstrated that the between‐sample variation was substantially larger than the within‐sample variation. Each sample could be differentiated from all other samples in the test set. Future experiments will focus on ways to reduce the within‐sample variation, and additional statistical and microanalytical methods to classify sources and confidently constrain the method of Al powder manufacture.

Baldaino, JenaMarie↗

Time series power flow analysis for distribution connected PV generation

Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating potential PV impacts.

Broderick, Robert Joseph↗

Widefield three-dimensional microscopy with a quantum entanglement light source

Devices, systems and methods for widefield three-dimensional (3D) microscopy with a quantum entanglement light source are described. An example method includes generating a first set of photons and a second set of photons, wherein each of the photons in the first set is quantum entangled with a corresponding photon in the second set, directing the second set of photons toward a sample and simultaneously directing the first set of photons toward a first two-dimensional (2D) detector, detecting, from the sample, a plurality of photons at a second 2D detector, analyzing detections from the first and second 2D detectors to determine coincidence information, and determining one or more characteristics associated with at least a three-dimensional (3D) section of the sample based on collective detections at the first and the second 2D detectors.

Bond, Tiziana C.↗

High-Resolution Aerial Radiation Mapping for Nuclear Decontamination and Decommissioning - 17371

Unmanned aerial vehicles (UAVs) are now widely employed as part of numerous applications including defence, search and rescue as well as within scientific fields such as high-altitude atmospheric sampling and remote sensing, to name but a few. However, their application to the high-resolution detection of radiation anomalies (specifically as part of the routine monitoring on nuclear sites) has been less well explored. In this work, we present the results of the radiation monitoring via a lightweight aerial platform on an active nuclear site (Sellafield Ltd.); having already deployed the device in the Fukushima-contaminated region. The system employed was able to detect regions of elevated radiation at the sub-meter scale as well as attributing the species responsible. Such a system presents an extremely powerful tool where it is not desirable, nor practical, to send human operators. Results presented show that the platform is easily capable of operating within the challenging and confined settings of a site such as Sellafield (or other similar sites worldwide). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]↗