Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Hydrogeology, chemical and microbial activity measurement through deep permafrost

Little is known about hydrogeochemical conditions beneath thick permafrost, particularly in fractured crystalline rock, due to difficulty in accessing this environment. The purpose of this investigation was to develop methods to obtain physical, chemical, and microbial information about the subpermafrost environment from a surface-drilled borehole. Using a U-tube, gas and water samples were collected, along with temperature, pressure, and hydraulic conductivity measurements, 420 m below ground surface, within a 535 m long, angled borehole at High Lake, Nunavut, Canada, in an area with 460-m-thick permafrost. Piezometric head was well above the base of the permafrost, near land surface. Initial water samples were contaminated with drill fluid, with later samples <40% drill fluid. The salinity of the non-drill fluid component was <20,000 mg/L, had a Ca/Na ratio above 1, with {delta}{sup 18}O values {approx}5{per_thousand} lower than the local surface water. The fluid isotopic composition was affected by the permafrost-formation process. Nonbacteriogenic CH{sub 4} was present and the sample location was within methane hydrate stability field. Sampling lines froze before uncontaminated samples from the subpermafrost environment could be obtained, yet the available time to obtain water samples was extended compared to previous studies. Temperature measurements collected from a distributed temperature sensor indicated that this issue can be overcome easily in the future. The lack of methanogenic CH{sub 4} is consistent with the high sulfate concentrations observed in cores. The combined surface-drilled borehole/U-tube approach can provide a large amount of physical, chemical, and microbial data from the subpermafrost environment with few, controllable, sources of contamination.

54 ENVIRONMENTAL SCIENCES↗

Fracture-matrix fluid exchange in oil-bearing unconventional mudstones

The poromechanical properties of unconventional reservoir materials are in large part dictated by their mineralogy. Since these properties govern the response to stress experienced during hydraulic fracturing, fluid production, and fluid injection, they play a central role in the formation of microcracks or bedding delaminations which ultimately dominate mass transport. In this work we study access to the porosity of end member unconventional reservoir materials, where the end members are predominantly dictated by carbonate content. Access to the porosity is quantified using state of the art 3D x-ray computed tomography coupled with physics informed data analytics. Xenon gas, which attenuates x-rays, provides a spatiotemporal map of access to the porosity. The accessible porosity is quantified over a range of net confining stress relevant to the manmade disturbances listed above. These experiments demonstrate that heavily carbonated mudstones are nearly impermeable at the core (~ cm) scale, while carbonate free analogues afford better access to the microstructure. Consistent with previous qualitative 2D radiographs, access to the interior of the clastic mudstones is first observed along planar microcracks, followed by slow penetration into the surrounding matrix. Physics informed data analytics of the 3D tomography measurements presented here show that these microcracks do not permit uniform access to the adjacent rock matrix. In addition, variation of the effective pressure elucidates the mechanisms that govern fracture/matrix fluid exchange. Under conditions consistent with hydrocarbon production fluid accumulates in the immediate vicinity of the nearest microcrack. While there is clear evidence that, as intended, part of this accumulation is from the more distant matrix, fluid is also squeezed out of the microcrack. The fluid build-up at the microcrack indicates that migration out of the rock is hindered by the coupled poroelastic response of the microcrack and adjacent rock matrix. We show that these mechanisms ultimately account for the meager oil recovery factors realized in practice. These insights have implications for making reservoir scale predictions based on core scale observations, and provide a basis for devising new asset development techniques to access more porosity, and enhance fluid extraction. Finally, these findings shed light on key features and mechanisms that govern shale storage capacity, with relevance to other important industrial processes, such as geologic CO 2 storage.

58 GEOSCIENCES↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Numerical Simulation of Bubble Formation in Co-Flowing Mercury

In this work, we present computational fluid dynamics (CFD) simulations of helium bubble formation and detachment at a submerged needle in stagnant and co-flowing mercury. Since mercury is opaque, visualization of internal gas bubbles was done with proton radiography (pRad) at the Los Alamos Neutron Science Center (LANSCE2). The acoustic waves emitted at the time of detachment and during subsequent oscillations of the bubble were recorded with a microphone. The Volume of Fluid (VOF) model was used to simulate the unsteady two-phase flow of gas injection in mercury. The VOF model is validated by comparing detailed bubble sizes and shapes at various stages of the bubble growth and detachment, with the experimental measurements at different gas flow rates and mercury velocities. The experimental and computational results show a two-stage bubble formation. The first stage involves growing bubble around the needle, and the second follows as the buoyancy overcomes wall adhesion. The comparison of predicted and measured bubble sizes and shapes at various stages of the bubble growth and detachment is in good agreement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Computational fluid dynamics study of pulverized coal combustion in blast furnace raceway

In this work, a numerical model is used to study the flow and coal combustion along the coal plume in a large-scale setting simulating the lance-blowpipe-tuyere-raceway region of a blast furnace. The model formulation is validated against the measurements in terms of burnout for both low and high volatile coals. The typical phenomena related to coal combustion along the coal plume are simulated and analyzed. The effects of some operational parameters on combustion behavior are also investigated. The results indicate that oxygen as a cooling gas gives a higher coal burnout than methane and air. The underlying mechanism of coal combustion is explored. It is shown that under the conditions examined, coal burnout strongly depends on the availability of oxygen and residence time. Moreover, the influences of two related issues, i.e. the treatment of volatile matter (VM) and geometric setting in modeling, are investigated. The results show that the predictions of final burnouts using three different VM treatments are just slightly different, but all comparable to the measurements. However, the influence of the geometric setting is not negligible when numerically examining the combustion of pulverized coal under blast furnace conditions.

01 COAL, LIGNITE, AND PEAT↗

Geothermal Fault Zone and Fluid Imaging through Joint Airborne ZTEM and Ground MT Data Inversion Analysis

This project has aimed to achieve detailed electrical resistivity resolution at geothermal reservoir scales by combining airborne natural electromagnetic (EM) field surveying (ZTEM) with ground magnetotelluric (MT) measurements to approximate an airborne MT geophysical method. MT alone is relatively expensive and may have permitting challenges in sensitive areas. Airborne ZTEM field data contains only the magnetic field, requires a background assumption, and has been limited to relatively high frequencies, thus suffering uniqueness problems. Based on proto-type 2D simulations, ZTEM ambiguities may be reduced through formal incorporation with possibly sparse ground MT soundings, which we pursued in full 3D for this project. The methodology was tested at the high-temperature Roosevelt Hot Springs geothermal system, Utah, which was considered advantageous given the near total exposure of crystalline reservoir rocks across the project area. ZTEM and ground MT survey data were acquired in 2017, subcontracted to outside parties with which we have worked in the past. These included 80 remote-referenced tensor MT soundings over the Mineral Mountains and adjacent Roosevelt Hot Spring producing geothermal system. These MT stations abut later coverage of a similar number of MT stations taken for the Utah FORGE project providing excellent total data aperture to re-solve structure beneath both project areas better than either set alone. The airborne ZTEM survey covered 704 line kilometers in E-W flight lines with a 250 m line spacing. Although this survey was timed during a maintenance-related shutdown of power production at the Roosevelt Hot Springs, other noise sources difficult to identify but including two high-voltage state-scale transmission lines compromised the ZTEM survey badly leading to unusable responses. Thus, with DOE management concurrence, the project proceeded to emphasize inversion and interpretation of the joint SubTER-FORGE MT data sets with regard to the Roosevelt Hot Springs reservoir recharge and to deep heat sources for both it and the Utah FORGE EGS project area. We also investigated the joint ZTEM-MT sampling concept with data sets from the Eleven Mile Canyon prospect area donated by the U.S. Navy (A. Sabin, PoC). Inversion of the SubTER-FORGE MT data using the HexMT 3D finite element algorithm reveals a large, low-resistivity anomaly extending sub-vertically through the depth range of the crust beneath the western Mineral Mountains. The steep conductive zone connects in the lower crust to a more tabular conductor characteristic of much of the Great Basin that generally is ascribed to current mafic magmatic underplating, hybridization and fluid release. The location of the resolved anomaly relative to the recent (0.5-0.8 Ma) eruptive centers of the Mineral Mountains implicates it as remnants of the magma body which fed these centers. This structure appears to be currently feeding heat and fluids upward into the Roosevelt Hot Springs hydrothermal system, as well as heat laterally to the FORGE project area. Separate and joint inversion models were carried out for the donated Eleven Mile Canyon MT-ZTEM data set to demonstrate concept. ZTEM only inversion showed two main alteration zones in the western portion of the project area known from geological mapping. Joint inversion including an E-W profile of MT soundings sharpened these features considerably. It also resolved in much greater detail the graben related normal faulting structure of the central project area which lies at depths exceeding the sensitivity of ZTEM alone. The sparse number of MT da-ta relative to the ZTEM required upweighting the former by a factor of several, but an exact procedure awaits future research. Our final impression is that sparse MT data can improve resolution of the subsurface over that of ZTEM alone. However, well sampled MT data are to be preferred and offer the simplicity of interpreting just one data type, and possess the superior resolution capability coming with the electric field everywhere, and from their high bandwidth.

15 GEOTHERMAL ENERGY↗

Taylor flow in intermediate diameter channels: Simulation and hydrodynamic models

The two-phase Taylor flow pattern has been studied extensively. However, limited information is available for flows in intermediate diameter channels (5 ≲ Bo ≲ 40, or 6mm ≲ D ≲ 27mm for ambient gas–water flows), as found in air-lift and bubble pumps. Previous investigations have primarily evaluated Taylor flow models in terms of overall pressure drop, which incorporates hydrostatic and multiple hydrodynamic components. Thus, individual sub-models and sources of error could not be directly assessed. Here in this investigation, volume-of-fluid (VOF) based Taylor flow simulations are performed over a wide range of laminar and turbulent conditions in the intermediate Bond number regime (5 < Bo < 20, 250 < N f < 1000, and 20 < Re j < 8100). Results are applied to individually evaluate hydrodynamic sub-models for bubble-region frictional pressure drop gradient (∇p f,b ), slug frictional pressure drop gradient (∇p f,s ), and flow transition pressure loss (Δp trans ). Based on these results, recommendations are provided for selection of hydrodynamic sub-models. These hydrodynamic closure models are integrated with kinematic flow models to yield a complete intermediate Bond number Taylor flow formulation for which all submodels were independently validated. The resulting model achieves improved accuracy for predicting experimental liquid flow rates compared with previous Taylor flow models (81% of cases within 50% of measured flows rates).

42 ENGINEERING↗

Long path-length experimental studies of longitudinal phenomena in intense beams

Intense charged particle beams are nonneutral plasmas as they can support a host of plasma waves and instabilities. The longitudinal physics, for a long beam, can often be reasonably described by a 1-D cold-fluid model with a geometry factor to account for the transverse effects. The plasma physics of such beams has been extensively studied theoretically and computationally for decades, but until recently, the only experimental measurements were carried out on relatively short linacs. This work reviews experimental studies over the past five years on the University of Maryland Electron Ring, investigating longitudinal phenomena over time scales of thousands of plasma periods, illustrating good agreement with simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthetic plasma edge diagnostics for EMC3-EIRENE, highlighted for Wendelstein 7-X

Interpretation of spectroscopic measurements in the edge region of high-temperature plasmas can be a challenge since line of sight integration effects make direct interpretation in terms of quantitative, local emission strengths often impossible. The EMC3-EIRENE code—a 3D fluid edge plasma and kinetic neutral gas transport code—is a suitable tool for full 3D reconstruction of such signals. A versatile synthetic diagnostic module has been developed recently which allows the realistic 3D setup of various plasma edge diagnostics to be captured. As a result, we highlight these capabilities with two examples for Wendelstein 7-X (W7-X): a visible camera for the analysis of recycling, and a coherent-imaging system for velocity measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Solubility of Tugarinovite (MoO 2 ) in H 2 O at Elevated Temperatures and Pressures

The solubility of tugarinovite (MoO 2 ) in pure water was investigated at temperatures between 400 and 800°C and at pressures ranging between 95 and 480 MPa by using in situ synchrotron X-ray fluorescence (SXRF) to separately analyze high temperature aqueous solutions in a hydrothermal diamond anvil cell (HDAC). The concentration of molybdenum in the fluid at 400 and 500°C was below detection; however, at temperatures between 600 and 800°C, the solubility of tugarinovite increased with increasing temperature by two orders of magnitude. The molybdenum concentration at 600°C and 800°C is 44 ppm and 658 ppm, respectively. The results complement the data of Kudrin (1985) and provide the first measurement of MoO 2 solubility at pressure and temperature conditions comparable to intrusion-related Mo deposit formation. The data are also relevant to the study of water chemistry and corrosion product transport in supercritical-water-cooled reactors, where Mo-bearing steel alloys interact with aqueous solutions at temperatures greater than 600°C. The application of in situ SXRF to solubility measurements of sparingly soluble minerals is recommended because it circumvents analytical uncertainties inherent in determinations obtained by quenching and weight loss measurements.

Saha, Pritam↗

Comparison of Experimental Measurements of Thermal Conductivity of Fe{sub 2}O{sub 3} Nanofluids Against Standard Theoretical Models and Artificial Neural Network Approach

In the present work, the practicability of Fe{sub 2}O{sub 3} nanofluids for heat transfer applications has been examined. Nanofluids performance, in terms of modulation of thermal conductivity, has been investigated with increasing concentration of Fe{sub 2}O{sub 3} nanoparticles in water and ethylene glycol base fluids at 10, 20, 30, 40, 50, 60 and 70 °C. Fe{sub 2}O{sub 3} nanoparticles have been synthesized using the wet chemical method and characterized using TEM, SEM, XRD and UV–Vis. The characterization results revealed a face-centered cubic structure having alpha phase and particle size in the range of 40-55 nm for the synthesized Fe{sub 2}O{sub 3} nanoparticles. Thermal conductivity measurement results show increases in thermal conductivity with the increase in concentration and temperature of nanofluids. 16.45 and 19.76% enhancement in thermal conductivity have been observed for Fe{sub 2}O{sub 3}–water and Fe{sub 2}O{sub 3}–ethylene glycol nanofluids of 2 vol.% at 70 °C compared to water and ethylene glycol base fluids at 10 °C, respectively. Results of the ANN approach are in good agreement with experimental results, and H–C model gives better predictions compared to other standard models. The study gives clear insights into improved heat transfer performance by material engineering.

36 MATERIALS SCIENCE↗

Shear-induced aggregation or disaggregation in edible oils: Models, computer simulation, and USAXS measurements

The effects of shear upon the aggregation of solid objects formed from solid triacylglycerols (TAGs) immersed in liquid TAG oils were modeled using Dissipative Particle Dynamics (DPD) and the predictions compared to experimental data using Ultra-Small Angle X-ray Scattering (USAXS). The solid components were represented by spheres interacting via attractive van der Waals forces and short range repulsive forces. A velocity was applied to the liquid particles nearest to the boundary, and Lees-Edwards boundary conditions were used to transmit this motion to non-boundary layers via dissipative interactions. The shear was created through the dissipative forces acting between liquid particles. Translational diffusion was simulated, and the Stokes-Einstein equation was used to relate DPD length and time scales to SI units for comparison with USAXS results. The SI values depended on how large the spherical particles were (250 nm vs. 25 nm). Aggregation was studied by (a) computing the Structure Function and (b) quantifying the number of pairs of solid spheres formed. Solid aggregation was found to be enhanced by low shear rates. As the shear rate was increased, a transition shear region was manifested in which aggregation was inhibited and shear banding was observed. Aggregation was inhibited, and eventually eliminated, by further increases in the shear rate. The magnitude of the transition region shear, $\dot{γ}_t$, depended on the size of the solid particles, which was confirmed experimentally.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge Fluctuations and Boundary Conditions of Biological Ion Channels: Effect on the Ionic Transition Rate

A self-consistent solution is derived for the Poisson-Nernst-Planck (PNP) equation, valid both inside a biological ion channel and in the adjacent bulk fluid. An iterative procedure is used to match the two solutions together at the channel mouth. Charge fluctuations at the mouth are modeled as shot noise flipping the height of the potential barrier at the selectivity site. The resultant estimates of the conductivity of the ion channel are in good agreement with Gramicidin experimental measurements and they reproduce the observed current saturation with increasing concentration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of the Number of Applied Current Meter Sensors on the Accuracy of Flow Rate Measurements across a Range of Hydroelectric Facilities Indicative of the Domestic Hydroelectric Fleet

The following paper represents the results of an investigation into the impact of the number and placement of Current Meter (CM) flow sensors on the accuracy to which they are capable of predicting the overall flow rate. Flow measurement accuracy is of particular importance in multiunit plants because it plays a pivotal role in determining the operational efficiency characteristics of each unit, allowing the operator to select the unit (or combination of units) which most efficiently meet demand. Several case studies have demonstrated that optimization of unit dispatch has the potential to increase plant efficiencies from between 1 to 4.4 percent [2] [3]. Unfortunately current industry standards do not have an established methodology to measure the flow rate through hydropower units with short converging intakes (SCI); the only direction provided is that CM sensors should be used. The most common application of CM is horizontally, along a trolley which is incrementally lowered across a measurement cross section. As such, the measurement resolution is defined horizontally and vertically by the number of CM and the number of measurement increments respectively. There has not been any published research on the role of resolution in either direction on the accuracy of flow measurement. The work below investigates the effectiveness of flow measurement in a SCI by performing a case study in which point velocity measurements were extracted from a physical plant and then used to calculate a series of reference flow distributions. These distributions were then used to perform sensitivity studies on the relation between the number of CM and the accuracy to which the flow rate was predicted. The following research uncovered that a minimum of 795 plants contain SCI, a quantity which represents roughly 12% of total domestic hydropower capacity. In regards to measurement accuracy, it was determined that accuracy ceases to increase considerably due to strict increases in vertical resolution beyond the application of 49 transects. Moreover the research uncovered that the application of 5 CM (when applied at 49 vertical transects) resulted in an average accuracy of 95.6% and the application of additional sensors resulted in a linear increase in accuracy up to 17 CM which had an average accuracy of 98.5%. Beyond 17 CM incremental increases in accuracy due to the addition of CM was found decrease exponentially. Future work that will be performed in this area will investigate the use of computational fluid dynamics to acquire a broader range of flow fields within SCI.

Flow Measurement↗

MRV Challenge 3: velocity and passive scalar comparison in a 3D turbulent flow

The third iteration of a magnetic resonance velocimetry (MRV) challenge comparison activity consisting of 3D flow measurements for a turbulent flow in a water channel moving past centrally positioned cubic obstacles is reported. In this challenge iteration, MRV measurements are coupled with either temperature or concentration measurements to extend the diagnostic utility. Five research teams from around the world conducted the measurements on a single shared apparatus. The water channel included partial elements along the channel sidewalls that varied in height and precluded easy optical accessibility. In addition to a turbulent mainstream flow, a secondary flow entered the channel between the second and third cubic elements from a square injector hole at the channel bottom wall. The injector jet interacts with the mainstream flow and mixes turbulently as it advects downstream. For the selected flow regime and water solutions used as working fluids, the mixing of the higher temperature or concentration through the secondary flow with the mainstream flow satisfies the same dynamics so that both temperature and concentration fields behave as passive scalars and can be directly compared. The measurements are explained in detail by each participating team, and the results are interpolated onto a common grid and compared using line profiles, contour plots, and isosurfaces.

Benson, Mike [ORNL] (ORCID:000000023210116X)↗

Synergistic smart fuel for in-pile nuclear reactor measurements

The thermo-acoustic fuel rod sensor developed in this research has demonstrated a novel technique for monitoring the temperature within the core of a nuclear reactor or the temperature of the surrounding heat-transfer fluid. It uses the heat from the nuclear fuel to generate sustained acoustic oscillations whose frequency will be indicative of the temperature. Converting a nuclear fuel rod into this type of thermo-acoustic sensor simply requires the insertion of a porous material (stack). This sensor has demonstrated a synergy with the elevated temperatures that exist within the nuclear reactor using materials that have only minimal susceptibility to high-energy particle fluxes. When the sensor is in operation, the sound waves radiated from the fuel rod resonator will propagate through the surrounding cooling fluid. The frequency of these oscillations is directly correlated with an effective temperature within the fuel rod resonator. This device is self-powered and is operational even in case of total loss of power of the reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Scaling Criteria for Modeling Condensation in Horizontal Tubes Using Reduced Pressure System and Simulant Fluid

Most of the currently operating nuclear power plants (NPPs), generation-II and III, are equipped with active safety systems, which raises concerns regarding those safety systems' operational reliability and the suitability of the accidents prevention measures. Following the severe accidents at nuclear power plants at Three Mile Island, Chernobyl, and recently in Fukushima some advance Pressurized Water Reactors (PWRs) have adopted passively cooled steam generator natural circulation system to remove the decay heat passively through the steam generator (SG). This is done by condensing steam from the steam generator inside a heat exchanger submerged in a tank of water or an air cooled system. The APR+ (Advanced Power Reactor Plus), which is currently being developed in South Korea, has adopted a Passive Auxiliary Feedwater System (PAFS), which removes the decay heat through the steam generator replacing the conventional active auxiliary feedwater system. The main part of the PAFS, in where the steam condenses, is the Passive Condensation Heat Exchanger (PCHX). The steam condenses under high pressure (7.4 MPa, 290 deg. C) in 8.4 m long horizontal tube, with 3 degrees inclination, with inner diameter of 44.8 mm and wall thickness of 3 mm. The PCHX consists of 4 bundles, each bundle has 60 condensation tubes. The performance of the PCHX performance should be evaluated. Condensation has been extensively studied; however, most previous experimental work was directed to low pressure (i.e., near atmospheric pressure) and small condensation tubes. Moreover, studies on the horizontal type heat exchanger are limited, since previous safety systems and experimentation work were directed to the vertical type heat exchangers. Due to the high construction cost of a full size high pressure condensation experiment, a reduced-size reduced-pressure condensation experiment is suggested to evaluate the heat removal performance of a condensation tube of the PAFS heat exchanger. A scaling methodology to be established to design a reduced-size reduced-pressure condensation experiment. This study attempts to develop a scaling criteria for the PAFS condensation system, and to apply it for modeling a high pressure water system by a low pressure Freon system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reynolds number effects on mixing due to topological chaos

Topological chaos has emerged as a powerful tool to investigate fluid mixing. While this theory can guarantee a lower bound on the stretching rate of certain material lines, it does not indicate what fraction of the fluid actually participates in this minimally mandated mixing. Indeed, the area in which effective mixing takes place depends on physical parameters such as the Reynolds number. To help clarify this dependency, we numerically simulate the effects of a batch stirring device on a 2D incompressible Newtonian fluid in the laminar regime. In particular, we calculate the finite time Lyapunov exponent (FTLE) field for three different stirring protocols, one topologically complex (pseudo-Anosov) and two simple (finite-order), over a range of viscosities. After extracting appropriate measures indicative of both the amount of mixing and the area of effective mixing from the FTLE field, we see a clearly defined Reynolds number range in which the relative efficacy of the pseudo-Anosov protocol over the finite-order protocols justifies the application of topological chaos. More unexpectedly, we see that while the measures of effective mixing area increase with increasing Reynolds number for the finite-order protocols, they actually exhibit non-monotonic behavior for the pseudo-Anosov protocol.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗