Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aberrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Determining the Coalescence of Hotspots into Uniform Detonation Fronts in High Explosives

Microwave Interferometry (MI) offers the advantage of a continuous time measurement of detonation front velocity from detonation initiation to disassembly, which is an important step to assure the quality of stockpile high explosives. However, the method is currently characterized by areas of poor signal strength, which lead to low confidence measurements. Experiments in inert materials were conducted to determine if reflective hot spots, pockets of plasma that form during detonation, are responsible due to varying hot spot concentrations. Instead, it was found that the copper tube used in a range of standard HE test configurations is the cause of the poor signal reception. Hot spots were represented by microwave reflective aluminum particles. The aluminum was mixed with Titanium Dioxide, a material electrically similar to the insensitive high explosive, triaminotrinitrobenzene (TATB), in volume percent fractions (VPFs) between 0 and 100% aluminum, in increments of 10%. Reflectivity was measured based on input and reflection received from a test apparatus with a layer representing undetonated explosive and another representing an approaching shockwave. The results showed no correlation between VPF and measured reflectivity test cases while enclosed in the standard copper tube. Upon further testing, each sample’s measured reflectivity independent of the copper enclosure did correlate with VPF. This revealed that the test enclosure currently used for MI measurements is causing poor MI signal reception, and new methods must be developed to account for this aberration in MI measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field Modeling, Symplectic Tracking, and Spin Decoherence for EDM and Muon $g\textrm{-}2$ Lattices

While the first particle accelerators were electrostatic machines, and several electrostatic storage rings were subsequently commissioned and operated, electrostatic storage rings pose a number of challenges. Unlike motion in the magnetic field, where particle energy remains constant, particle energy generally changes in electrostatic elements. Conservation of energy in an electrostatic element is, in practice, only approximate, and it requires careful and accurate design, manufacturing, installation, and operational use. Electrostatic deflectors require relatively high electrostatic fields, tend to introduce nonlinear aberrations of all orders, and are more challenging to manufacture than homogeneous magnetic dipoles. Accordingly, magnetic storage rings are overwhelmingly prevalent. The search for electric dipole moments (EDMs) of fundamental particles is of key importance in the study of C and CP violations and their sources. C and CP violations are part of the Sakharov conditions that explain the matter–antimatter asymmetry in the universe. Determining the source of CP violations would provide valuable empirical insight for beyond-Standard-Model physics. EDMs of fundamental particles have not to this date been experimentally observed. The search for fundamental particle EDMs has narrowed the target search region; however, an EDM signal is yet to be discovered. In 2008, Brookhaven National Laboratory (BNL) had proposed the frozen spin (FS) concept for the search of a deuteron EDM. The FS concept envisions launching deuterons through a storage ring with combined electrostatic and magnetic fields. The electrostatic and magnetic fields are in a proportion that would, without an EDM, freeze the deuteron’s spin along its momentum as the deuteron moves around the lattice. The radial electrostatic field would result in a torque on the spin vector, proportional to a deuteron EDM, rotating the spin vector out of the midplane.

43 PARTICLE ACCELERATORS↗

Riding the Electricity Market as an Energy Management Strategy: Savings from Real-Time Pricing

Dynamic pricing of electricity, in which retail prices facing customers are responsive to changes in the underlying wholesale markets, represents a step towards economic efficiency in that customers get exposed to some or all of the costs facing wholesale market players. But what do customers who opt for this greater exposure – available in the roughly 15 “de-regulated” states, as well as, to some extent, from some regulated utilities – get in return for their risks? The U.S. General Services Administration (GSA) took a retrospective eight-year look at what the savings would have been had they let the loads for which they purchase electricity in the Washington, DC area buy electricity on the real-time pricing (RTP) market – the dynamic pricing option with the highest risk – as opposed to the strategy they chose in actuality, which was fixing flat prices with 3rd-party providers. We found that opting for RTP for the eight years of the study (2005 through 2012) would have resulted in 17% savings, or almost a quarter of a billion dollars, relative to GSA’s actual prices from the 3rd-party suppliers. This is particularly astonishing given that GSA appeared to have timed the market well during the study period, consistently beating the standard offer products provided by the distribution utilities. The issue of budgetary predictability poses an obstacle for customers (especially government ones) considering RTP and, to a lesser extent, other dynamic pricing options. Indeed, GSA would have lost money with RTP in two of the eight years, one of them substantially. But the magnitude of the savings is indisputably compelling and, even if it may be somewhat aberrational due to high congestion in the DC market, begs consideration by large electricity users currently paying to “lock in” fixed flat prices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Numerical simulations of realistic grating compressors

Chirped pulse amplification (CPA), originally proposed by Strickland and Mourou, is a critical enabling technology for creating very short laser pulses with very high peak power. It consists of three optical components: a stretcher, an amplifier, and a compressor. An initial laser pulse of short duration and low energy content is first stretched out in time by the stretcher, resulting in a pulse with longer duration, low energy content, and very low peak power. The pulse is then amplified to increase its energy content without changing its duration in time. The amplified pulse is finally compressed in time in the compressor, resulting in a laser pulse with very short duration and very high peak power. The objective of this work is to develop numerical techniques that enable small-scale grating aberrations in the compressor to be analyzed through high performance computer simulations.

97 MATHEMATICS AND COMPUTING↗

DARMA-EMPIRE Integration and Performance Assessment – Interim Report

We begin by presenting an overview of the general philosophy that is guiding the novel DARMA developments, followed by a brief reminder about the background of this project. We finally present the FY19 design requirements. As the Exascale era arises, DARMA is uniquely positioned at the forefront of asychronous many-task (AMT) research and development (R&D) to explore emerging programming model paradigms for next-generation HPC applications at Sandia, across NNSA labs, and beyond. The DARMA project explores how to fundamentally shift the expression(PM) and execution(EM)of massively concurrent HPC scientific algorithms to be more asynchronous, resilient to executional aberrations in heterogeneous/unpredictable environments, and data-dependency conscious—thereby enabling an intelligent, dynamic, and self-aware runtime to guide execution.

97 MATHEMATICS AND COMPUTING↗

Radiation-induced Swelling and Microcracking in SiC Cladding for LWRs

After the Fukushima accident in 2011, SiC has attracted considerable attention as a potential material for fuel cladding that can offer increased accident tolerance in light water reactors (LWRs) compared to zircaloy cladding. Existing measurements on nuclear grade SiC/SiC composites made of high-purity, stoichiometric SiC have already shown very good radiation tolerance in various harsh environments. However, there are a number of challenges that need to be addressed before SiC composites can be successfully used in LWR technologies. One of them is irradiation-induced swelling, which can lead to development of significant stresses in the matrix, followed by microcracking and subsequent release of fission products. Models of irradiation-induced swelling had been largely empirical and therefore they cannot be used to predict the microstructural dependence of microcracking. Existing models are also limited by the lack of understanding of defects that form due to irradiation in the range of temperatures relevant to fuel cladding in LWRs (<1000°C). Many of the defects in this regime of temperature are too small to be detected with traditional transmission electron microscopy (TEM) techniques. In fact the defects observed in traditional TEM account only for 10-45% of the swelling measured in irradiated SiC. Here, we developed a multi-scale simulation methodology combined with state of the art experimental imaging techniques based on aberration corrected scanning transmission electron microscopy (STEM) to provide a scientific basis for predictive models of radiation swelling and microcracking in SiC. Specifically, we have developed a phase field fracture model that predicts microcrack initiation and growth in polycrystalline SiC. The model accounts for single crystal anisotropy, including anisotropy in the elastic constants and anisotropic surface energy. It also considers the reduced fracture strength of grain boundaries. The model was implemented using the MARMOT mesoscale nuclear materials tool. We have parameterized the model for SiC using molecular dynamics simulation results. The model has been verified using single crystal, bicrystal, and polycrystal examples. Swelling model has also been developed based on cluster dynamics simulations of defect evolution in SiC. We found that point defects and small defect clusters have a significant contribution to swelling. This finding is important because point defects and very small defect clusters are not visible in experiments (e.g., in TEM). Combined modeling and experiments can bring critical insights into how swelling depends on irradiation conditions and the microstructure. In situ nanoindentation tests and ex situ nanoindentation tests were performed on assynthesized 3C-SiC and 3C-SiC irradiated under different radiation conditions. Without radiation, bend contour movement and residual bend contours after indentation demonstrate some room temperature plastic flow and residual plastic deformation. Plastic deformation recovery is also observed on unirradiated samples during unloading. Radiation-induced embrittlement is demonstrated by differences in crack geometry in in situ tests, and is consistent with ex situ test results. Failure by single, straight, cracks indicates decreased fracture toughness due to irradiation in 3C-SiC. Future work includes coupling of the swelling and fracture models and development of a master equation that can be used in the BISON code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Focus Solenoid Design Considerations

Radiography utilizing intense relativistic electron beams requires a final focus magnet to produce a small beam spot on the x-ray conversion target. A solenoid magnet is generally used for the final focus magnet. This note addresses design considerations of the final focus solenoid that impact the spot size. The spot size on target is a function of the beam size entering the final focus magnet, the beam emittance and energy spread and spherical aberration inherent in a solenoid magnet. The present final focus solenoid designs for both Axis 1 and Axis 2 of the DARHT facility are evaluated. A new design is proposed for both Axis 1 and Axis 2.

43 PARTICLE ACCELERATORS↗

Report of the Basic Energy Sciences Workshop on the Future of Electron Sources, September 8-9, 2016

Electron sources represent an enabling technology for all cutting-edge applications of electron accelerators, two of the most notable ones being the X-ray free electron laser (FEL) and the electron microscope. FELs were enabled by the development of high-brightness electron sources, and they have changed the paradigm for a broad spectrum of scientific research. Electron microscopes have achieved sub-Å spatial resolution through the introduction of a cold field-emitter and aberration correction optics. Further development of these tools to atomic spatial and temporal resolutions is needed to advance atomic and molecular sciences to new levels of precision. Though the field of electron sources is quite mature, both revolutionary and evolutionary advances in electron sources are needed. On September 8-9, 2016, BES sponsored a Workshop on the Future of the Electron Source at SLAC National Accelerator Laboratory. The goal of the workshop was to define the electron source requirements for future XFELs, UED and UEM, and to identify future research and development (R&D) opportunities. More than sixty participants from U.S. national laboratories, academia, and international institutions attended the workshop. The workshop started with four plenary talks covering the status of electron sources, and highlighting the most urgent needs of future X-ray and electron scattering facilities. The talks made it evident that significant progress in electron sources will not only maximize the impact of current facilities, but also enable novel capabilities that can help maintain the U.S. leadership in X-ray and electron-based scattering instrumentation. Four breakout panels addressed the major technical areas of electron sources: (1) science and technology of electron generation, (2) continuous wave (CW) electron sources, (3) pulsed electron sources, and (4) exotic electron sources. Prior to the workshop, the panel co-chairs polled the panelists and other experts in the field and invited them to make recommendations on the most promising ways to advance the field of electron sources. During the workshop, each panel reviewed the proposals and novel ideas submitted. These summaries of the discussions on scientific needs and instrument requirements and their recommendations form the basis of this report.

43 PARTICLE ACCELERATORS↗

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗

Z-Petawatt Laser Highlights for FY21

We’re happy to report that the full-aperture upgrade project, started in FY18, is now complete and short-pulse target experiments are underway. The table below lists the present performance level of ZPW. Additional laser improvements are in progress to increase the laser energy and pulse contrast along with implementing a correction for achromatic aberrations to reduce the focused spot size and pulse width.

47 OTHER INSTRUMENTATION↗

Development of a Direct Neutral Density Diagnostic for Fusion Edge Plasmas

As magnetically confined plasmas progress towards ignition and long pulse experiments, measurement and control of the neutral density in the plasma edge has become a critical issue for stability, formation of transport barriers, and fueling. Recent experiments by our research group have demonstrated that is possible to use two-photon absorption laser induced fluorescence (TA-LIF) to directly measure the density of neutral hydrogen in helicon sources and in the HIT-SI3 spheromak. While those experiments validated key elements of a diagnostic system that would enable similar measurements in tokamak plasmas, they did not fully address the issue of performance optimization in the presence of intense background light at the fluorescence wavelength and they also identified a number of other issues that must be resolved before successful TALIF neutral density measurements in a tokamak are likely to be achieved. Additional specific concerns raised during design reviews with the leadership of the DIII-D tokamak facility included: the minimum detection threshold for this TALIF diagnostic (currently ~ 5 x 10 15 m -3 ) and the rate at which neutral density measurements could be obtained. Improving the system performance to reduce the minimum detection threshold and demonstrating a faster rate of density determination are required to advance this diagnostic to the level where it could be considered for implementation on a major tokamak facility in the USA. The key issues that will be addressed through additional technological development are: validation of a new, chromatic aberration-free, xenon calibration scheme; increasing the output power of the laser; and suppression of background emission at the fluorescence wavelength through optimization of the collection optics and gating of the photomultiplier detector with a goal of obtaining a minimum detection threshold of 5 x 10 14 m -3 . Another key technological development, so far only tested in helicon source experiments, is the validation of Doppler-free TALIF as a means of obtaining higher speed, calibrated, neutral density measurements in tokamak-like conditions at the full cadence of the pulsed TALIF laser. In this work, we propose to complete these technological advancements through installation and testing of our prototype TALIF system on the proto-MPEX experiment at Oak Ridge National Laboratory (ORNL). The proto-MPEX facility will provide plasma conditions similar to the edge plasma of a major tokamak experiment but with pulse lengths and pulse repetition rates ideally suited for extensive development of a TALIF neutral density diagnostic. Measurement of the absolute neutral density in the edge of a magnetically confined plasma is necessary for plasma density control; calculation of charge-exchange power losses; control of plasma-wall interactions; determination of the braking of plasma flow; determination of the fuel mixture in deuterium-tritium plasma; and understanding the dynamics of the divertor region in the plasma edge. In terms of potential impact on the worldwide fusion program, we note that in burning plasma experiments, such as ITER, a 100 mJ/pulse Doppler-free TALIF diagnostic should be capable of directly measuring the deuterium/tritium (D/T) isotope ratio in the outer 0.5 to 1.0 m of the plasma radius. The D/T ratio is a critically important parameter for the control and optimization of burning plasmas. Therefore, development of the diagnostic system proposed here is also relevant to long-term US participation in diagnostic development for large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current Status of Developing Ultrafast Mega-electron-volt Electron Microsope

Recent studies of ultrafast electron microscopy (UEM) techniques show the use of short bunches of relativistic electrons is promising for the development of a new instrument for imaging various materials. Compared to conventional electron microscopes, the main advantage of UEMs with the electron energy of a few MeV is the possibility to study thick samples. We will discuss the progress of UEM design to date, the principal challenges on the way to a high resolution, and possible methods for their mitigation including the design of low-aberration magnetic optics, RF and mechanical subsystems with high stability, and precise collimation of electrons scattered in the samples.

43 PARTICLE ACCELERATORS↗

Optimal gas cooling with minimal aero-opticaldistortion for next generation high-average-power lasers (Progress report, Year 2)

Next-generation lasers that combine high-peak-power ultrashort pulses with high repetition rates have the potential to efficiently deliver the high-average-power outputs required for inertial fusion energy generation, laser-based particle acceleration, and to generate compact secondary x- and 𝛾-ray radiation sources, among others. The combination of long gain length with high surface-to-volume ratio to remove residual heat makes gas-cooled multi-slab amplifier heads an inherently aperture- and average power scalable technology that enables this new class of solid-state lasers, and their thermal management becomes the most pressing technical challenge. As the index-of refraction depends on the gas density, heat removal from the slab surfaces unavoidably entails scattering of propagated light from regions of high temperature fluctuations. The requirement to maximize convective heat extraction from the gain medium under the constraint of minimum optical aberration of the beam renders amplifier slab cooling a technological challenge at the intersection of aero-optics, fluid-mechanics and heat transfer. The goal of this research is to leverage computational fluid dynamics and aero optics simulations of different levels of fidelity to devise a numerical modeling and optimization framework for gas-cooled multi-slab amplifiers. The project will be conducted in close collaboration with the Advanced Photon Technologies Group at Lawrence Livermore National Laboratory, where a gas-cooled test stand for laser materials and thermal management structures will be developed and installed. The final goal of the collaborative effort is to manufacture and benchmark a physical prototype of an numerically optimized amplifier head design. Measurement data on solid-state and thermo-optical distortions will be used for the validation of the numerical models. The key technical challenge in this multi-objective design problem is that of balancing optimal heat removal with minimal optical distortion. To facilitate computationally efficient design optimization and, at the same time, deepen our basic understanding of the interaction of light with turbulence, a complementary study that combines high and low-fidelity flow simulations and aero-optical models is proposed. Along the lines of these two objectives and solution strategies, the project is organized into two thrusts.

42 ENGINEERING↗

Towards resolving protein structures at the atomic scale using atom probe tomography

In the field of Structural Biology, Atom Probe Tomography (APT) is in the nascent stages of development wherein coarse-grained visuals of proteins have been captured. The characterization of organic samples or biomolecules through the technique is currently limited to the detection of a few dominant signatures. The problem of indecipherable characterization can inherently be traced back to multiple forms of technique-specific responses to organic samples and consequent triggers leading to organic-sample and sample-medium interactions. While it is possible for captured manifestations of protein reconstructions to seemingly appear intact from a basic visual purview, the parameter-protein associative responses throughout the structure as a direct consequence of the inherent workings of the technique (until harmonized with organic sample complexity and behavior) and field evaporation-based factors make non-aberrative atomic associations infeasible. The work focused on identifying and theorizing the (above stated and other) fundamental mechanisms that stronghold the study of intricate atomic to higher order associations in proteins through APT. Attempts at structure elucidation of the cryogenic sample under study, through indirect associations (and methods) based on other imaging techniques, further revealed the distinct and highly distortive nature at the atomic scale deterring structural tunability and thus characterization of APT based cryogenic samples under analysis. As a direct counter to the atomic scale characterization problem, by taking the experiment-specific uncertainties, and probable APT-centric organic sample-based variabilities into account, a basic result is extracted and presented. Through mass-spectrometric and computational analysis, specific individual amino acids (Sulfur-containing protein-bound amino acids) in proteins and aspects of protein structure (probable backbone fragments, partial sequence - partial backbone portions) have been identified and characterized. Under analysis considerations, a few of the simplest known and easily inferable segments that favor structural deteriorations in the reconstructions are stated. Additionally, to overcome technique-specific deterrents to the characterization of biomolecules in cryogenic sample medium, the development of a protein-labeling strategy tailored to APT is suggested.

59 BASIC BIOLOGICAL SCIENCES↗

Contactless Position Measurement System for Remote Alignment of Highly Reflective Objects

The Contactless Position Measurement System (CPMS) permits automatic alignment of highly-reflecting components that cannot or should not be touched by human hands, such as those used in SRF cavities. CPMS also has application during maintenance of fusion reactors, when the components in the reactor are radioactive. The length of time for which humans can handle the components in order to carry out maintenance or repairs is limited. We would like to measure the relative positions of such objects so we can bring them into alignment with motorized stages, thus eliminating the need for human contact. The CPMS is a computer vision system that measures the location of highly reflective components to within a fraction of a millimeter by finding the edges of silhouette images. This is done by placing a uniform, infrared backlight behind the components, and viewing each component with two low-aberration, infrared cameras. Each of these stereoscopic cameras are located within a coordinate system we set up with reference platforms, light sources, and survey cameras distributed around the perimeter of the string assembly room, or fusion reactor. We obtain stereoscopic silhouette images of each component, and we use these to determine the position of the component within our string assembly coordinate system. The CPMS combines the silhouette images with knowledge of the dimensions of the objects to obtain the relative positions of components in its field of view. These position measurements then allow us to mechanically maneuver the components into contact. Once we know where they are, we can move the components to where they are supposed to be with motorized stages or other mechanical means, check they are in the right place, and bolt them together. In Phase I, we built a prototype infrared backlights and cameras, tested it, wrote an analysis program to fit the images. At a range of 50 cm, we are able to measure the relative positions of two stainless steel flanges with an accuracy of 150 μm rms. The next steps are to test the analysis program with motorized stages, build a full-size prototype, and implement it in an cleanroom with SRF cavity assembly. This can be done in a cost effective way given the materials with which the system is designed. As Open Source Instruments achieved more in Phase I than anticipated, despite not receiving a Phase II SBIR grant, we hope to move forward with product development and sales with a testing partner.

43 PARTICLE ACCELERATORS↗

LITE-SM: A Light Sheet Illuminator Compatible with Super Resolution and Single Molecule Imaging

The LITE-SM (hereinafter referred to as the Tilt-SM) is a light sheet illumination system purpose-built for single molecule (SM) imaging. SM imaging is a fluorescence imaging technique where individual molecules can be tracked in living cells/tissues in real time allowing for unprecedented insights into the intracellular dynamics of these molecules. The innovative all-mirror optical design greatly reduces/eliminates the aberrations that plague lens-based designs. This iteration of the Tilt-SM has significantly better optical performance then its predecessor with over 10x increase in optical power at the sample, allowing for the use of much smaller and more cost-effective lasers then the original Phase 1 system. Excellent STORM imaging as well as SM tracking has been achieved, satisfying the key objectives of this study.

59 BASIC BIOLOGICAL SCIENCES↗

Electron Energy-Loss Spectroscopy and Differential Phase Contrast Imaging with Active Decision in Multimodal Electron Microscopy: Isotopic detection at the atomic scale

Isotopic engineering provides a powerful route to control phonon behavior in crystalline solids, enabling fundamental studies of lattice dynamics and heat transport at the atomic scale. Here, we directly visualize isotope-dependent phonon propagation in epitaxial Cr 2 O 3 using aberration-corrected scanning transmission electron microscopy (STEM) combined with monochromated, high-energy-resolution electron energy-loss spectroscopy (EELS). Guided by ab initio phonon calculations, we demonstrate that optical phonon modes above 70 meV are predominantly oxygen-derived and exhibit measurable redshifts upon substitution of natural 16 O by enriched 18 O. Spatially resolved vibrational spectrum imaging reveals isotope-enriched tracer layers within Cr 2 O 3 thin films, correlating isotope concentration with phonon intensity variations and vibrational energy shifts. At the nanometer and atomic scales, vibrational EELS mapping uncovers coherent phonon propagation across isotopic interfaces, consistent with theoretical phonon density of states and dispersion relations. These results establish vibrational EELS as a quantitative probe for isotope-dependent phonon transport in materials, opening new possibilities for studying energy dissipation and lattice dynamics.

36 MATERIALS SCIENCE↗

Viability of Miniature Discs in LFA-427

Miniature disc samples pose challenging measuring conditions for laser flash analysis. With reductions in signal from lower radiosity and lower half-rise times from low thicknesses, optimal selections of coatings and laser parameters are critical in a successful measurement. This report explains the methodology in successfully measuring two different material types—metals and ceramics—in proper coating selection, laser parameters, and post analysis for each material, as well as applying it to un-irradiated uranium samples of each type (U-metal, UO 2 ). This was done through a combination of analysis techniques combining automatic commercial methods (Neztech) and manual methods for correcting laser pulse impact aberrations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗