Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Assessments of advanced reactor heat supply to high temperature industrial unit operations: Heat Engines and Heat Pumps

In this report, the feasibility of employing Advanced Nuclear Reactors to supply the necessary high-quality heat to Industrial Processes is investigated. As a first step, the most relevant industrial applications that could benefit from this coupling were identified. Four industries including petroleum refining (distillation, catalyst regeneration, hydro-steam cracking), chemical polymers, steel manufacturing (metals annealing/soaking) and cement manufacturing (calcination of limestone and dolomite industries) were considered. An overview of the heat duties, i.e., the temperatures and thermal powers required by representative plants of the different processes, was provided. Secondly, the thermodynamic conditions of the steam produced by representative designs of Advanced Reactor concepts (Liquid Metal Fast Breeder Reactors, Molten Salt Reactors, and High Temperature Gas-cooled Reactors) were summarized. The comparison between the requirements of the industrial processes and the capabilities of the candidate nuclear power plants showed that only a few processes could benefit from the coupling. Although Advanced Reactors operate at higher temperatures than Light Water Reactors, the thermodynamic conditions of the generated steam flow rates are generally not suitable for the selected applications. At the same time, data indicate that most of the processes can be suitably supplied if the temperature of steam is elevated to 900 °C. One possible solution to boost the quality of the steam from the nuclear island involves the use of a heat pump. Based on a technology similar to that found in refrigerators and air conditioners, heat pumps extract heat from a source, elevate its temperature and transfer it to where it is needed. A simple numerical example illustrating the viability of this method is described. Specifically, the energy conversion cycle of a conventional Pressurized Water Reactor was extended to incorporate a compressor to raise the heating value of the steam produced by the reactor. Two reference configurations, i.e., one where the industrial process coupled to the nuclear power plant exhausts saturated liquid and the other where it exhausts saturated steam, were considered. The thermal efficiencies achievable by increasing the heating value of the reactor steam in this way are significantly greater than by direct electric heating.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Defining the Mechanism of Proton Pumping in Heme-Copper Oxidases

During this award, progress was made in two distinct areas of science, one was within the context of bioinorganic chemistry and another in the context of biomimetic, small molecule chemistry. The overarching goals of this work was to understand the fundamental mechanistic drivers for biological reactions specifically, proton transfer reactions. In the biochemical sphere, this goal was investigated through investigation of the bacterial proton pump, ubiquinol oxidase (UbO). Further work in the bioinorganic space was completed in collaboration with the Bandarian group on a novel natural peptide product. While in the biomimetic space, this work was explored through a computational collaborative study with the Riordan group relating to proton coupled electron transfers in iron complexes as relating to the heme active site in proton pumping enzymes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stabilizing the Grid and Reducing Utility Bills Through Price-Responsive Controls for Heat Pump Water Heaters

The electricity grid is facing increasing challenges in cost-effectively balancing supply and demand. These challenges are exacerbated by increased penetration of photovoltaics, which causes mid-day overproduction, and electrification of gas appliances, which increases peak-period electricity demand. Decarbonization requires shifting building loads from fossil-intensive high-cost times to renewable-intensive low-cost times while maintaining quality of service to occupants. Utilities and ISO’s are investigating new ways of incentivizing this load shifting. One promising method is the use of Highly Dynamic Prices (HDPs). HDPs feature continuously changing prices that reflect real-time grid generation and distribution costs and capacity constraints, and thus incentivize consumers to shift their loads. California’s CPUC CalFUSE proposal and Hawaii’s recent changes demonstrate that electricity tariffs are moving towards this model. For this to work however, loads must have the capability to respond to these prices. Heat pump water heaters (HPWHs) are an ideal device for this purpose because their storage tanks decouple delivery of domestic hot water from electricity consumption. The storage enables control strategies that consume midday solar power to increase the energy stored in the tank, then provide evening peak domestic hot water services using the stored energy. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls for many flexible loads - including HPWHs - in response to HDP. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of the on-board controller in a residential, integrated HPWH . The price-responsive controls a) shift load in ways that consume additional midday solar power to help stabilize the grid and reduce overall emissions, b) ensure that occupants receive equal or better hot water delivery service, and c) minimize the operating cost for each home in the fleet. On the grid level, the resulting shift will reduce utility operating costs and emissions, and can avoid expensive system capacity expansions. The control approach is customized to each home based on typical hot water consumption patterns. HPWH controllers, whether on the device or remotely, will receive a schedule of CTA-2045-B signals or set temperature adjustments customized to the current HDP price schedule and home. Simulation results for a fleet of 148 HPWHs on a summer day in Berkeley, California show cost savings of 29% and high price electricity consumption reductions of 80%, while maintaining full quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conceptual Design of a Pumped Water Capsule for TREAT

This study performed mechanical design, thermal hydraulic, and fuel performance investigations to determine whether an existing large water capsule design could be modified to create forced convection boundary conditions on nuclear fuel specimens in the Transient Reactor Test facility. This concept was found to be viable and offers several advantages compared to a static water environment for a variety of transient power shape categories. The pumped capsule is not foreseen to be superior to a past concept for a larger water loop, but the pumped capsule approach is recommended for further engineering and deployment based on its high cost-to-value ratio primarily as a stop gap capability until a larger water loop can be realized.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermoelectric heat pump water heater priced for mass market deployment with 30% energy savings

This project, a Cooperative Research and Development Agreement (CRADA) partnership between A. O. Smith and Oak Ridge National Laboratory (ORNL), was initiated to develop a heat pump water heater (HPWH) based on thermoelectric (TE) heat pump technology capable of seeing widespread market adoption by having a one-year payback versus electric resistance options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pump Development for Fusion-Based Neutron Generators

Tritium usage in fusion-based neutron generators is low for each pulse. This requires the deuterium/tritium mixture to be evacuated and recycled during downtime or to remove the helium buildup. Because of the pressure ranges and to minimize space, turbomolecular pumps are being considered for the tritium recirculation pumps. Two main types were initially considered: Agilent TwisTorr and Osaka TG-MR.

Angelette, Lucas M. [Savannah River National Labor↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) (Final Report)

This report is a final deliverable for project 81966: Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) Commercial heat pump water heater (CHPWH) systems can significantly improve the energy efficiency of service water heating (SWH), aka domestic hot water (DHW), in commercial and multifamily buildings but have not yet achieved widespread adoption due to pricing, complexity, and perceived risk factors. The goal of this project – Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial HPWHs (Scaling Up) – was to demonstrate and validate a holistic systems approach for CHPWHs that de-risks the technology, creating a reliable, cost-effective, and repeatable approach to CHPWH deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deployable UHV Pump

This project presents an external motorized actuation system for a deployable ultra-high vacuum (UHV) pump, enabling internal motion without compromising vacuum conditions. All active components remain external due to environmental and space constraints. A motor-driven mechanical feedthrough transfers motion into the pump, supported by a modular, adjustable mounting system that maintains alignment and integrates with existing hardware. CAD modeling and iterative design were used to refine geometry and ensure proper fit. The final design reliably transfers motion while maintaining alignment and structural integrity. Its adjustability improves installation and maintenance, demonstrating a practical solution for actuation in UHV systems.

Remington, Austin [Northern Illinois U.]↗

Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

Experimental performance analysis of a dual source heat pump integrated with thermal energy storage

To mitigate disturbances to the electric grid resulting from the growing penetration of intermittent and decentralized renewable generation, a dual-source (air source and ground source) heat pump (DSHP) integrated with thermal energy storage (TES) was developed. The DSHP can use either ambient air or the shallow subsurface of the ground to provide space heating or space cooling to the building as the conventional heat pump and produce hot/cold water for charging TES. Using dual sources (air and ground) can reduce the required size of the expensive ground heat exchangers while retaining high energy efficiency. During the off-peak period, the DSHP cools/heats the TES with low-cost electricity or overproduced renewable power. The stored cooling/heating energy in the TES is released during peak hours of the electric grid to meet the thermal demands of the building without consuming electricity to run the DSHP. A 2-ton (7 kW) prototype DSHP was developed and integrated with a 50-gallon (189 L) TES tank filled with a phase change material. Field tests were conducted to characterize the performance of the integrated system operating in various operation modes.

Wang, Lingshi↗

A solar-pumped fluorescence model for line-by-line emission intensities in the B–X, A–X, AND X–X band systems of {sup 12}C{sup 14}N

We present a new quantitative model for detailed solar-pumped fluorescent emission of the main isotopologue of CN. The derived fluorescence efficiencies permit estimation and interpretation of ro-vibrational infrared line intensities of CN in exospheres exposed to solar (or stellar) radiation. Our g-factors are applicable to astronomical observations of CN extending from infrared to optical wavelengths, and we compare them with previous calculations in the literature. The new model enables extraction of rotational temperature, column abundance, and production rate from astronomical observations of CN in the inner coma of comets. Our model accounts for excitation and de-excitation of rotational levels in the ground vibrational state by collisions, solar excitation to the A{sup 2}Π{sub i} and B{sup 2}Σ{sup +} electronically excited states followed by cascade to ro-vibrational levels of X{sup 2}Σ{sup +}, and direct solar infrared pumping of ro-vibrational levels in the X{sup 2}Σ{sup +} state. The model uses advanced solar spectra acquired at high spectral resolution at the relevant infrared and optical wavelengths and considers the heliocentric radial velocity of the comet (the Swings effect) when assessing the exciting solar flux for a given transition. We present model predictions for the variation of fluorescence rates with rotational temperature and heliocentric radial velocity. Furthermore, we test our fluorescence model by comparing predicted and measured line-by-line intensities for X{sup 2}Σ{sup +} (1–0) in comet C/2014 Q2 (Lovejoy), thereby identifying multiple emission lines observed at IR wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗

ALMA Multiple-transition Molecular Line Observations of the Ultraluminous Infrared Galaxy IRAS 20551–4250: Different HCN, HCO{sup +}, and HNC Excitation, and Implications for Infrared Radiative Pumping

We present our ALMA multi-transition molecular line observational results for the ultraluminous infrared galaxy IRAS 20551−4250, which is known to contain a luminous buried active galactic nucleus and shows detectable vibrationally excited (v {sub 2} = 1f) HCN and HNC emission lines. The rotational J = 1–0, 4–3, and 8–7 of HCN, HCO{sup +}, and HNC emission lines were clearly detected at a vibrational ground level (v = 0). Vibrationally excited (v {sub 2} = 1f) J = 4–3 emission lines were detected for HCN and HNC, but not for HCO{sup +}. Their observed flux ratios further support our previously obtained suggestion, based on J = 3–2 data, that (1) infrared radiative pumping plays a role in rotational excitation at v = 0, at least for HCN and HNC, and (2) HCN abundance is higher than HCO{sup +} and HNC. The flux measurements of the isotopologue H{sup 13}CN, H{sup 13}CO{sup +}, and HN{sup 13}C J = 3–2 emission lines support the higher HCN abundance scenario. Based on modeling with collisional excitation, we constrain the physical properties of these line-emitting molecular gases, but find that higher HNC rotational excitation than HCN and HCO{sup +} is difficult to explain, due to the higher effective critical density of HNC. We consider the effects of infrared radiative pumping using the available 5–30 μm infrared spectrum and find that our observational results are well-explained if the radiation source is located at 30–100 pc from the molecular gas. The simultaneously covered very bright CO J = 3–2 emission line displays a broad emission wing, which we interpret as being due to molecular outflow activity with the estimated rate of ∼150 M{sub ⊙} yr{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and characterization of an ice-selecting pumped counterflow virtual impactor (IS-PCVI) to study ice crystal residuals

Separation of particles that play a role in cloud activation and ice nucleation from interstitial aerosols has become necessary to further understand aerosol-cloud interactions. The pumped counterflow virtual impactor (PCVI), which uses a vacuum pump to accelerate the particles and increase their momentum, provides an accessible option for dynamic and inertial separation of cloud elements. However, the use of a traditional PCVI to extract large cloud hydrometeors is difficult mainly due to its small cut-size diameters (< 5 µm). Here, for the first time we describe a development of an ice-selecting PCVI (IS-PCVI) to separate ice in controlled mixed-phase cloud system based on the particle inertia with the cut-off diameter ≥ 10 µm. We also present its laboratory application demonstrating the use of the impactor under a wide range of temperature and humidity conditions. The computational fluid dynamics simulations were initially carried out to guide the design of the IS-PCVI. After fabrication, a series of validation laboratory experiments were performed coupled with the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) expansion cloud simulation chamber. In the AIDA chamber, test aerosol particles were exposed to the ice supersaturation conditions (i.e., RH ice > 100 %), where a mixture of droplets and ice crystals was formed during the expansion experiment. In parallel, the flow conditions of the IS-PCVI were actively controlled, such that it separated ice crystals from a mixture of ice crystals and cloud droplets, which were of diameter ≥ 10 µm. These large ice crystals were passed through the heated evaporation section to remove the water content. Afterwards, the residuals were characterized with a suite of online and offline instruments downstream of the IS-PCVI. These results were used to assess the optimized operating parameters of the device in terms of (1) the critical cut-size diameter, (2) the transmission efficiency and (3) the counterflow-to-input flow ratio. Particle losses were characterized by comparing the residual number concentration to the rejected interstitial particle number concentration. Overall results suggest that the IS-PCVI enables inertial separation of particles with a volume-equivalent particle size in the range of ~&thinsp;10–30 µm in diameter with small inadvertent intrusion (~ &thinsp;5 %) of unwanted particles.

54 ENVIRONMENTAL SCIENCES↗

Fine-particle filter prevents damage to vacuum pumps

A filter system for mechanical pumps is designed with a baffle assembly that rotates in a circulating oil bath which traps destructive particles. This prevents severe damage to the pump and is serviceable for long periods before it requires cleaning.

Harlamert, P., Jr.↗

Closed loop operation eliminates need for auxiliary gas in high pressure pumping station

Closed loop system for a liquid nitrogen high pressure pump feeds back gaseous nitrogen generated by heat leak into the reservoir to maintain the pressure in the storage tank. This safer, more efficient system eliminates the need for auxiliary gas to maintain the tank pressure and can be used on relatively high cryogenic pumping systems.

Landy, D. G.↗