Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

T2SL Focal Planes for Compact Remote Sensing Instruments

In this presentation, we will report our recent efforts in achieving high performance in Antimonides type-II superlattice (T2SL) based infrared photodetectors using the barrier infrared detector (BIRD) architecture. The high operating temperature (HOT) BIRD focal plane arrays (FPAs) offer the same high performance, uniformity, operability, manufacturability, and affordability advantages as InSb. However, mid-wavelength infrared (MWIR) HOT-BIRD FPAs can operate at significantly higher temperatures (>150K) than InSb FPAs (typically 80K). Moreover, while InSb has a fixed cutoff wavelength (~5.4 µm), the HOT-BIRD offers a continuous adjustable cutoff wavelength, ranging from ~4 µm to >15 µm, and is therefore also suitable for long wavelength infrared (LWIR) as well. The LWIR detectors based on the BIRD architecture has also demonstrated significant operating temperature advantages over those based on traditional p-n junction designs. Two 6U SmalSat missions CIRAS (Cubesat Infrared Atmospheric Sounder) and HyTI (Hyperspectral Thermal Imager) are based on JPL’s T2SL BIRD focal plane arrays (FPAs). Based on III-V compound semiconductors, the BIRD FPAs offer a breakthrough solution for the realization of low cost (high yield), high-performance FPAs with excellent uniformity and pixel-to-pixel operability. We have also exploring the possibilities of implementing either metasurface resonator cavity or metasurface based flatlens to improve the signal-to-noise ratio of the detectors.

Ghuman, Parminder↗

Bunch mode specific rate corrections for PILATUS3 detectors

PILATUS X-ray detectors are in operation at many synchrotron beamlines around the world. This article reports on the characterization of the new PILATUS3 detector generation at high count rates. As for all counting detectors, the measured intensities have to be corrected for the dead-time of the counting mechanism at high photon fluxes. The large number of different bunch modes at these synchrotrons as well as the wide range of detector settings presents a challenge for providing accurate corrections. To avoid the intricate measurement of the count rate behaviour for every bunch mode, a Monte Carlo simulation of the counting mechanism has been implemented, which is able to predict the corrections for arbitrary bunch modes and a wide range of detector settings. This article compares the simulated results with experimental data acquired at different synchrotrons. It is found that the usage of bunch mode specific corrections based on this simulation improves the accuracy of the measured intensities by up to 40% for high photon rates and highly structured bunch modes. For less structured bunch modes, the instant retrigger technology of PILATUS3 detectors substantially reduces the dependency of the rate correction on the bunch mode. The acquired data also demonstrate that the instant retrigger technology allows for data acquisition up to 15 million photons per second per pixel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging Technique for High Precision Measurement of Detector Stability for the Ocean Color Instrument

One of the new projects by NASA to explore environmental change is the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) spacecraft. The primary instrument aboard the PACE spacecraft is the Ocean Color Instrument (OCI), an advanced optical spectrometer that will measure the color of the ocean from the ultraviolet to shortwave infrared range for the purpose of observing and monitoring ocean and coastal biology. As part of the optical alignment testing that must be completed before the instrument is built, the measurement stability of the detectors at space flight operating temperatures must be determined to ensure alignment is maintained. Therefore, this project focuses on the development of an imaging technique that adheres to testing requirements and can be used to determine the stability of the OCI detector. The movements of targets affixed to a high-precision stage were analyzed through an image processing program to test the ability of the imaging technique to detect very small (under 10 micrometers) movements. It was found that movements as small as half a pixel (~6 microns) and 1 pixel (~12 microns) were able to be accurately and consistently detected with this imaging technique. This project found that the designed image analysis technique fulfills testing and measurement requirements and will be an effective metrology technique for the OCI detector stability test.

Optics↗

Production-Ready CsPbBr3 Module Fabrication

The purpose of this SBIR was to work on evaluation, development, and testing of CsPbBr3 semiconductors for use in commercial gamma-ray detection. The overarching goal was to demonstrate the capability to fabricate functional detectors through resources available to H3D, Inc in pursuit of an alternative to CdZnTe for room-temperature semiconductor detectors. Throughout the project, CdZnTe crystals from Redlen were used as a control group to demonstrate whether the fabrication processes could produce reasonable results. The CdZnTe crystals were diced into roughly 6 mm x 6 mm x 4.5 mm pieces and electrodes were evaporated onto planar faces. In one case, pixels were patterned through a laser ablation method; in the other, a rudimentary pixel shadow-mask was fabricated, and the pixels were generated in the evaporation process. A 16 mm x 16 mm x 14 mm CsPbBr3 crystal was diced into four smaller crystals. These CsPbBr3 had electrodes applied in a similar way to the CdZnTe samples with a rudimentary mask used for pixels on the cathode. Tested CdZnTe pieces were found to generally function with reasonable, low-energy performance. CsPbBr3 crystals were found to be non-functional under forward bias with a large dark-current. A separate attempt, using reverse bias in a non-H3D, Inc test system, observed a dark current similar to previous observations, and some active pixels but no waveforms were observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Patient-Specific 3D Pretreatment and Potential 3D Online Dose Verification of Monte Carlo-Calculated IMRT Prostate Treatment Plans

Purpose: Fast and reliable comprehensive quality assurance tools are required to validate the safety and accuracy of complex intensity-modulated radiotherapy (IMRT) plans for prostate treatment. In this study, we evaluated the performance of the COMPASS system for both off-line and potential online procedures for the verification of IMRT treatment plans. Methods and Materials: COMPASS has a dedicated beam model and dose engine, it can reconstruct three-dimensional dose distributions on the patient anatomy based on measured fluences using either the MatriXX two-dimensional (2D) array (offline) or a 2D transmission detector (T2D) (online). For benchmarking the COMPASS dose calculation, various dose-volume indices were compared against Monte Carlo-calculated dose distributions for five prostate patient treatment plans. Gamma index evaluation and absolute point dose measurements were also performed in an inhomogeneous pelvis phantom using extended dose range films and ion chamber for five additional treatment plans. Results: MatriXX-based dose reconstruction showed excellent agreement with the ion chamber (<0.5%, except for one treatment plan, which showed 1.5%), film ({approx}100% pixels passing gamma criteria 3%/3 mm) and mean dose-volume indices (<2%). The T2D based dose reconstruction showed good agreement as well with ion chamber (<2%), film ({approx}99% pixels passing gamma criteria 3%/3 mm), and mean dose-volume indices (<5.5%). Conclusion: The COMPASS system qualifies for routine prostate IMRT pretreatment verification with the MatriXX detector and has the potential for on-line verification of treatment delivery using T2D.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transparent Ceramic Garnet Gamma-Ray Spectrometer With Directionality

We have developed a handheld γ -ray spectrometer based on 1024 pixels, 2.8mm×2.8mm×6 mm in size, of gadolinium–yttrium–gallium–aluminum garnet (GYGAG) ((Gd,Y,Ce) 3 (Ga,Al) 5 O 12 ) ceramic scintillator (total of 48-cm 3 detector volume) coupled to silicon photodiode (SiPD) arrays. The SiPD arrays and readout ASIC, originally developed for medical imaging applications, have been adapted for portability in a lightweight box with heatsink and thermoelectric cooling. Custom readout firmware for γ-ray spectroscopy has been implemented, and a system user interface was developed that runs on an Android tablet. Here, we have optimized the processing of the GYGAG(Ce), the pixel optical coupling, and electronics readout parameters to obtain single pixel energy resolution as good as R(662keV)=3.1 % full-width at half-maximum and full device resolution with singles events from all pixels summed of 4.5%. When Compton-summed events are included, full-energy peak efficiency increases by ~2× , and R(662keV)=4.7 % is obtained for the full device. The pixelated architecture is leveraged to locate point sources of radiological materials using Compton imaging and active masking techniques. Directional detection of a 1 mCi Cs-137 source at 10 m can be made to ±10° in ~2 s.

42 ENGINEERING↗

Evaluation and characterization of hybrid arrays

An Infrared Camera was built for astronomical observations and for testing arrays for satellite based work. The detectors are sensitive to mid infrared wavelengths. The camera was tested at the University of Arizona 61 and 90 inch telescopes and the NASA IRTF. These tests have demonstrated a sensitivity consistent with photon shot noise with an approximately 10% quantum efficiency for each pixel when the camera was used with a 1.6% spectral filter or when used with a Fabry-Perot having a resolving power of 2000. Initial measurements of read out noise, dark current, cross talk, and hysteresis were made. The detector chip in current use is a hybrid array manufactured by the Hughes Aircraft Company. Because part of the goal was to develop and advance technology, it was decided to work with a switched MOSFET array. This architecture is very promising, and the detector parameters will be quantified carefully.

Arens, J. F.↗

Development of a prototype Open-close positron emission tomography system

We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of {sup 18}F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of planar silicon pixel sensors with the RD53A readout chip for the Phase-2 Upgrade of the CMS Inner Tracker

The Large Hadron Collider at CERN will undergo an upgrade inorder to increase its luminosity to7.5 × 10$^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosityduring this High-Luminosity running phase, starting around 2029,means a higher rate of proton-proton interactions, hence a largerionizing dose and particle fluence for the detectors. The currenttracking system of the CMS experiment will be fully replaced inorder to cope with the new operating conditions. Prototype planarpixel sensors for the CMS Inner Tracker with square50 μm × 50 μm and rectangular100 μm × 25 μm pixels read out by theRD53A chip were characterized in the lab and at the DESY-II testbeamfacility in order to identify designs that meet the requirements ofCMS during the High-Luminosity running phase. A spatial resolutionof approximately 3.4 μm (2 μm) is obtained using themodules with 50 μm × 50 μm(100 μm × 25 μm) pixels at the optimalangle of incidence before irradiation. After irradiation to a 1 MeVneutron equivalent fluence ofΦ$_{eq}$ = 5.3 × 10$^{15}$ cm$^{-2}$, a resolution of9.4 μm is achieved at a bias voltage of 800 V using a modulewith 50 μm × 50 μm pixel size. All modulesretain a hit efficiency in excess of 99% after irradiation tofluences up to 2.1 × 10$^{16}$ cm$^{-2}$. Further studies ofthe electrical properties of the modules, especially crosstalk, arealso presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation methodology for characterizing the energy response function and resolving power of a digital Flat Panel Detector (FPD) assembly

The use of high-resolution, digital flat panel detectors (FPDs) makes quantitative assessments of radiographic and 3D tomographic representations feasible. However, the energy response function and spatial resolving power of the detector must be known. Here, we present a methodology for characterizing an FPD assembly using Monte Carlo simulations. The detector assembly modeled here was fielded in the 3-Ring Flash X-ray Imaging System designed and built at Lawrence Livermore National Laboratory (LLNL), which employs fifteen Carestream ® HPX-DR3543 FPDs enclosed in protective housings. Detailed Monte Carlo (MCNP6) simulations of an as-fielded detector assembly were performed to estimate its energy response function in terms of analog-to-digital unit (ADU) “counts” per pixel per incident x-ray as a function of energy up to ∼ 500 keV and its theoretical (idealized) resolving power. The practical resolving power of the FPD assembly in a realistic scenario was then estimated by simulating radiographic images of a variant of the United Kingdom (U.K.) “Kaleidoscope” resolution target.

Physics↗

Development of POTATO for 2S Module Grading for the CMS Phase-2 Outer Tracker Upgrade

Due to the High Luminosity-Large Hadron Collider (HL-LHC) upgrade, several detectors of the Compact Muon Solenoid (CMS) will need to be upgraded, specifically the new Outer Tracker detector that will be composed of 13,200 silicon modules. The Outer Tracker features two types of modules; the PS (pixel-strip) and the 2S (strip-strip) modules. With a large influx of production of modules, extensive testing is required to ensure they fulfill the performance requirements. This research introduces POTATO (Phase-II Outer Tracker Analyzer of Test Outputs), a specialized software developed in C++ to analyze, grade, and store results in a centralized database since module data will be collected from various international production facilities. The implementation of POTATO will facilitate the selection of the best performing modules for the Outer Tracker upgrade. This paper is focused on the implementation of the analysis of 2S Module results within POTATO.

43 PARTICLE ACCELERATORS↗

Excalibur: A Nonparametric, Hierarchical Wavelength Calibration Method for a Precision Spectrograph

Excalibur is a nonparametric, hierarchical framework for precision wavelength calibration of spectrographs. It is designed with the needs of extreme-precision radial-velocity (EPRV) instruments in mind, which require calibration or stabilization to better than 10{sup −4} pixels. Instruments vary along only a few dominant degrees of freedom, especially EPRV instruments that feature highly stabilized optical systems and detectors. Excalibur takes advantage of this property by using all calibration data to construct a low-dimensional representation of all accessible calibration states for an instrument. Excalibur also takes advantage of laser-frequency combs or etalons, which generate a dense set of stable calibration points. This density permits the use of a nonparametric wavelength solution that can adapt to any instrument or detector oddities better than parametric models, such as a polynomial. We demonstrate the success of this method with data from the Extreme Precision Spectrograph (EXPRES), which uses a laser-frequency comb. When wavelengths are assigned to laser comb lines using excalibur, the rms of the residuals is about one-fifth that of wavelengths assigned using polynomial fits to individual exposures. Radial-velocity measurements of HD 34411 show a reduction in rms scatter over a 10 month time baseline from 1.17 to 1.05 m s{sup −1}.

47 OTHER INSTRUMENTATION↗

The new MSFC Solar vector magnetograph. Center director's discretionary fund

The unique MSFC solar vector magnetograph allows measurements of all three components of the Sun's photospheric magnetic field over a wide field-of-view with spatial resolution determined by a 2.7 x 2.7 arc second pixel size. This system underwent extensive modifications to improve its sensitivity and temporal response. The modifications included replacing an SEC vidicon detector with a solid-state CCD camera; replacing the original digital logic circuitry with an electronic controller and a computer to provide complete, programmable control over the entire operation of the magnetograph; and installing a new polarimeter which consists of a single electro-optical modulator coupled with interchangeable waveplates mounted on a rotating assembly. The system is described and results of calibrations and tests are presented. Initial observations of solar magnetic fields with the new magnetograph are presented.

Hagyard, M. J.↗

Radiometric analyses of Landsat-4 digital image data

The results of analyses of the radiometric characteristics of digital image data produced by the Landsat 4 MSS and TM sensors are reviewed. The MSS analysis found high quality data comparable to the products of previous Landsats, except for a low-level coherent noise effect having a magnitude of about 0.5 counts in each band and a spatial period of about 3.6 pixels. The TM analysis found excellent spatial resolution, generally high data quality and expected scan-angle effects. Procedures for equalizing detector responses appear to be working as intended. Two low-amplitude artifacts also were discovered. The first is associated with the direction of scan (TM employs bidirectional scanning). The second, a very low employs bidirectional scanning). The second, a very low frequency level-shift artifact which produces image banding that is most pronounced in TM1, could be a serious problem for water-related applications or others where average signal levels are low. Correction procedures are under investigation.

Malila, W. A.↗

Evaluation of selected detector arrays for space applications

The development of a high density Schottky barrier Infrared Charged Coupled Device (IRCCD) type image sensor for earth observation was initiated. A dual band 512 pixel linear array was developed, which was capable of being butted end to end to make an arbitrarily long linear array. Measurement made on palladium silicide IRCCDs that were two-dimensional 63 x 32 pixel arrays were summarized. The test data on a 512 pixel linear array is also summarized.

Lowrance, J. L.↗

The prototype MOSAIC detector

The prototype of the MOSAIC (Mosaicked Optical Self-scanned Array Imaging Camera) system, a photon-counting detector designed for use in the far ultraviolet, is described. MOSAIC has a two-dimensional format of 2400 x 2400 pixels, and is easily expandable. Readout is accomplished electronically via charge-coupled devices, making possible remote observations. Preliminary results of computer simulations of the system are presented.

Weistrop, D.↗

Microchannel Plates for the UVCS and SUMER Instruments on the SOHO Satellite

The microchannel plates for the detectors in the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) and UVCS (Ultraviolet Coronograph Spectrometer) instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in late 1995 are described. A low resistance Z stack of microchannel plates (MCP's) is employed in a detector format of 27 mm x 10 mm using a multilayer cross delay line anode (XDL) with 1024 x 360 digitized pixels. The MCP stacks provide gains of greater than 2 x 10(exp 7) with good pulse height distributions (as low as 25% FWHM) under uniform flood illumination. Background rates of approx. 0.6 event cm(exp -2) sec(exp -1) are obtained for this configuration. Local counting rates up to about 800 events/pixel/sec have been achieved with little drop of the MCP gain. MCP preconditioning results are discussed, showing that some MCP stacks fail to have gain decreases when subjected to a high flux UV scrub. Also, although the bare MCP quantum efficiencies are close to those expected (10%), we found that the long wavelength response of KBr photocathodes could be substantially enhanced by the MCP scrubbing process. Flat field images are characterized by a low level of MCP fixed pattern noise and are stable. Preliminary calibration results for the instruments are shown.

Siegmund, O. H. W.↗

Design and Fabrication of a Two-Dimensional Superconducting Bolometer Array

Large format, two dimensional arrays of close-packed bolometers will enable submillimeter cameras and spectrometers to obtain images and spectra orders of magnitude faster than present instruments. The South Pole Imaging Fabry-Perot Interferometer (SPIFI) for the AST/RO observatory and the Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory will employ a large-format, two-dimensional, closepacked bolometer arrays. Both these instruments are imaging Fabry-Perot spectrometers operating at wavelengths between 100 micron and 700 micron. The array format is 16x32 pixels, using a 32-element multiplexer developed in part for this purpose. The low backgrounds achieved in spectroscopy require very sensitive detectors with NEPs of order 5x10(exp 18) W/square root of Hz. Superconducting detectors can be close-packed using the Pop-Up Detector (PUD) format, and SQUID multiplexers operating at the detector bas temperature can be intimately coupled to them. We have fabricated an engineering model array with this technology which features a very compact, modular approach for large format arrays.

Benford, Dominic↗