Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Experimental Validation of a Module Cell Cracking Model

The What's Cracking app can predict how changes in crystalline silicon photovoltaic (PV) module materials, design, and mounting affect its susceptibility for cell fracture under uniform loading. This work has experimentally validated the app. A set of commercial crystalline silicon PV modules was obtained for this study. The modules were uniformly loaded at three different mounting points, and their subsequent cell fractures were recorded. A large sample size allowed for the development of an experimental statistical model for cell fracture. Here, the comparison of the experiment to predictions from the app is in excellent agreement. Both experimental and modeling results also elucidate how moving the module mounting points toward the center of the module increases the probability of cell fracture.

14 SOLAR ENERGY↗

Reduced-Order Structure-Preserving Model for Parallel-Connected Three-Phase Grid-Tied Inverters

Next-generation power networks will contain large numbers of grid-connected inverters satisfying a significant fraction of system load. Since each inverter model has a relatively large number of dynamic states, it is impractical to analyze complex system models where the full dynamics of each inverter are retained. To address this challenge, we derive a reduced-order structure-preserving model for parallel-connected grid-tied three-phase inverters. Here, each inverter in the system is assumed to have a full-bridge topology, LCL filter at the point of common coupling, and the control architecture for each inverter includes a current controller, a power controller, and a phase-locked loop for grid synchronization. We outline a structure-preserving reduced-order inverter model with lumped parameters for the setting where the parallel inverters are each designed such that the filter components and controller gains scale linearly with the power rating. By structure preserving, we mean that the reduced-order three-phase inverter model is also composed of an LCL filter, a power controller, current controller, and PLL. We show that the system of parallel inverters can be modeled exactly as one aggregated inverter unit and this equivalent model has the same number of dynamical states as any individual inverter in the system. Numerical simulations validate the reduced-order model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of a Load-Alleviating Structure on the Landing Behavior of a Reentry-Capsule Model

Model tests have been made to determine the landing-impact characteristics of a parachute-supported reentry capsule that had a compliable metal structure as a load-alleviating device. A 1/6-scale dynamic model having compliable aluminum-alloy legs designed to give a low onset rate of acceleration on impact was tested at flight-path angles of 90 degrees ( vertical ) and 35 deg, at a vertical velocity of 30 ft/sec ( full scale), and at contact attitudes of 0 deg and +/-30 deg. Landings were made on concrete, sand, and water. The maximum acceleration encountered was approximately 35g and the maximum onset rate was 2,000 g/sec. on concrete a t the 55 deg flight-path, f30 contact-attitude conditions; therefore, load-alleviating devices on the canister end of the model would be required. To evaluate the scaling characteristics of compliable metal structures, models were tested with 1/4.1-scale and full-scale aluminum-alloy legs. The maximum vertical accelerations and strokes obtained from tests of the 1/4.1-scale and full-scale legs were the same within the recording accuracy of the equipment. Acceleration time histories for the 90 degree flight-path, 0 deg contact-attitude condition were computed and are in good agreement with the experimental results.

Hoffman, Edward L.↗

Material Model Testing in the DYNA3D Code: Material Models 1 through 5

This report is the first volume in an effort to study the material model implementations in DYNA3D, using the latest developmental version of the code. Input files were derived from a template supplied by Jerry Lin to perform an equation-of-state study. Most of the simulations use 10 cubes, each 1 cm on a side with a density of 8.03 (steel). Each of the cubes tests a different aspect of the material model. The first three cubes are testing normal stresses and normal strains (uniaxial stresses and strains) placed on the cube parallel to the x-axis, y-axis and z-axis, respectively. The x (or y or z) = 1 face of the cube is moved along the x-axis (or y-axis or z-axis) to test the model, while the opposite side remains in the x (or y or z) = 0 plane. For some of the tests, the nodes are free to move perpendicular to the applied strain to allow the cross-sectional area of the cube to change in response to being placed under pressure or tension (to test Poisson’s Ratio), while in others the nodes are frozen to eliminate dynamic effects resulting from the code. The cube is placed in tension along the axis being tested and then released, followed by a cycle of compression and release. This tension/compression cycle is repeated 3 more times. The additional cycles allow for the model to be tested under different loads. For these calculations, the amount by which the cube is stretched and compressed is varied from cycle to cycle to allow testing of model features. Cubes number 4 and 5 are intended to test xy shear stresses/strains. This is done by sliding one face of the cube in its plane parallel to the axis of interest. For example, for cube 4, the upper face of the cube is slid in the y=1 plane in a direction parallel to the x-axis (so there are no changes in the y and z coordinates of the points in the plane) and then returned to its starting position. This preserves the volume of the cube, so there is no change in density or pressure. The cycle is repeated 8 times. For cube 5, the plane of the cube satisfying x=1 is slid in this plane in a direction parallel to the y-axis and then returned to its starting position. This preserves the volume of the cube, so there is no change in density or pressure. The cycle is repeated 8 times. Cubes number 6 through 9 repeat these tests for yz shear stresses/strains (Cubes 6 and 7) and zx shear stresses and strains (Cubes 8 and 9). For reasons discussed in the next paragraph, it is unclear if these tests represent a state of pure shear stress and shear strain in the code. Application of shear stresses and strains should not, in general, result in the appearance of normal stresses and strains in Cubes 4 - 9. In the infinitesimal limit, this result might be obtained. However, DYNA3D is a finite deformation code and in the real deformations used in the code, this result is not achieved and the individual components of the normal stresses and strains are non-zero during the cycling. However, the sums of the normal strains are zero in these tests and, except in the case of thermally dependent models, so are the sums of the normal stresses. Cube 10 tests the response of the material model to a hydrostatic loading of the cube. The load curve used for the first three tests is used again and applied to each of the 8 nodes in a manner causing the cube to be either compressed or expanded. This compression/tension cycle is repeated 4 times. The additional cycles allow for the model to be tested under different loads. The amount by which the cube is stretched and compressed is varied from cycle to cycle to allow testing of model features. This document will discuss the testing of Material Models 1 through 5. Relevant results from the test cubes will be discussed. A discussion of the results from all 10 test cubes will be presented only if necessary.

36 MATERIALS SCIENCE↗

Improving the accuracy of energy baseline models for commercial buildings with occupancy data

More than 80% of energy is consumed during operation phase of a building's life cycle, so energy efficiency retrofit for existing buildings is considered a promising way to reduce energy use in buildings. The investment strategies of retrofit depend on the ability to quantify energy savings by “measurement and verification” (M&V), which compares actual energy consumption to how much energy would have been used without retrofit (called the “baseline” of energy use). Although numerous models exist for predicting baseline of energy use, a critical limitation is that occupancy has not been included as a variable. However, occupancy rate is essential for energy consumption and was emphasized by previous studies. This study develops a new baseline model which is built upon the Lawrence Berkeley National Laboratory (LBNL) model but includes the use of building occupancy data. The study also proposes metrics to quantify the accuracy of prediction and the impacts of variables. However, the results show that including occupancy data does not significantly improve the accuracy of the baseline model, especially for HVAC load. The reasons are discussed further. In addition, sensitivity analysis is conducted to show the influence of parameters in baseline models. To conclude, the results from this study can help us understand the influence of occupancy on energy use, improve energy baseline prediction by including the occupancy factor, reduce risks of M&V and facilitate investment strategies of energy efficiency retrofit.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Battery Equivalent Model for Residential HVAC

Flexible loads, especially heating, ventilation, and air-conditioning (HVAC) systems can be used to provide a battery-like service to the power grid by varying their demand up and down over a baseline. Recent work has reported that the round-trip efficiency for providing grid services with HVAC systems can be close to 1. Inspired by this promising result, in this work, we rigorously develop a battery equivalent model (BEM) for residential HVAC systems. Relying only on typically available data, the proposed BEM will bridge the observability and controllability gaps between utility companies and customers. The proposed BEM will enable the utility companies to manage the flexible HVAC devices as easy as charging/discharging the conventional energy storage devices. Validated physics-based models are used to train the BEM, whose prediction accuracy is illustrated through a simulation study.

Dong, Jin↗

CD8 + lymphocyte control of SIV infection during antiretroviral therapy

CD8 + lymphocytes play an important role in suppressing in vivo viral replication in HIV infection. However, both the extent to which and the mechanisms by which CD8 + lymphocytes contribute to viral control are not completely understood. A recent experiment depleted CD8 + lymphocytes in simian immunodeficiency virus (SIV)-infected rhesus macaques (RMs) on antiretroviral treatment (ART) to study the role of CD8 + lymphocytes. CD8 + lymphocytes depletion resulted in temporary plasma viremia in all studied RMs. Viral control was restored when CD8 + lymphocytes repopulated. We developed a viral dynamic model to fit the viral load (VL) data from the CD8 depletion experiment. We explicitly modeled the dynamics of the latent reservoir and the SIV-specific effector cell population including their exhaustion and their potential cytolytic and noncytolytic functions. We found that the latent reservoir significantly contributes to the size of the peak VL after CD8 depletion, while drug efficacy plays a lesser role. Our model suggests that the overall CD8 + lymphocyte cytolytic killing rate is dynamically changing depending on the levels of antigen-induced effector cell activation and exhaustion. Based on estimated parameters, our model suggests that before ART or without ART the overall CD8 cytolytic killing rate is small due to exhaustion. However, after the start of ART, the overall CD8 cytolytic killing rate increases due to an expansion of SIV-specific CD8 effector cells. Further, we estimate that the cytolytic killing rate can be significantly larger than the cytopathic death rate in some animals during the second phase of ART-induced viral decay. Lastly, our model provides a new explanation for the puzzling findings by Klatt et al. and Wong et al. that CD8 depletion done immediately before ART has no noticeable effect on the first phase viral decay slope seen after ART initiation Overall, by incorporating effector cells and their exhaustion, our model can explain the effects of CD8 depletion on VL during ART, reveals a detailed dynamic role of CD8 + lymphocytes in controlling viral infection, and provides a unified explanation for CD8 depletion experimental data.

59 BASIC BIOLOGICAL SCIENCES↗

Bearing tester fit analysis

A NASTRAN model of the Bearing Tester was developed to determine the fit of its components while in use. The model was executed for three loading conditions involving appropriate thermal and pressure loading throughout: rotation (30,000 rpm), rotation with 5000 lb axial shaft loading, and rotation with 2000 lb lateral shaft loading. A 30 deg slice of the Bearing Tester was modeled with solid isoparametric elements (CIHEX). Five more slices were generated to form a 180 deg symmetrical half. Each component was modeled separately for two reasons: (1) in the heat transfer version each component required covering with appropriate heat transfer coefficient elements, and (2) for the displacement version each component required independent radial expansion with respect to adjacent components. The components are connected at fastener and bearing locations axially and/or tangentially. Differences in radial displacements of adjacent cylindrical surfaces were calculated and added to those differences calculated for 180 deg opposite locations to determine the diametric change.

Source record↗

The Use of a Block Diagram Simulation Language for Rapid Model Prototyping

The research performed this summer was a continuation of work performed during the 1995 NASA/ASEE Summer Fellowship. The focus of the work was to expand previously generated predictive models for liquid oxygen (LOX) loading into the external fuel tank of the shuttle. The models which were developed using a block diagram simulation language known as VisSim, were evaluated on numerous shuttle flights and found to well in most cases. Once the models were refined and validated, the predictive methods were integrated into the existing Rockwell software propulsion advisory tool (PAT). Although time was not sufficient to completely integrate the models developed into PAT, the ability to predict flows and pressures in the orbiter section and graphically display the results was accomplished.

Whitlow, Johnathan E.↗

Damage Simulation in Non-Crimp Fabric Composite Plates Subjected to Impact Loads

Progressive failure analysis (PFA) of non-crimp fabric (NCF) composite laminates subjected to low velocity impact loads was performed using the COmplete STress Reduction (COSTR) damage model implemented through VUMAT and UMAT41 user subroutines in the frame works of the commercial finite element programs ABAQUS/Explicit and LS-DYNA, respectively. To validate the model, low velocity experiments were conducted and detailed correlations between the predictions and measurements for both intra-laminar and inter-laminar failures were made. The developed material and damage model predicts the peak impact load and duration very close with the experimental results. Also, the simulation results of delamination damage between the ply interfaces, in-plane matrix damages and fiber damages were all in good agreement with the measurements from the non-destructive evaluation data.

Satyanarayana, Arunkumar↗

Precise Comparisons of Bottom-Pressure and Altimetric Ocean Tides

A new set of pelagic tide determinations is constructed from seafloor pressure measurements obtained at 151 sites in the deep ocean. To maximize precision of estimated tides, only stations with long time series are used; median time series length is 567 days. Geographical coverage is considerably improved by use of the international tsunami network, but coverage in the Indian Ocean and South Pacific is still weak. As a tool for assessing global ocean tide models, the data set is considerably more reliable than older data sets : the root-mean-square difference with a recent altimetric tide model is approximately 5 mm for the M2 constituent. Precision is sufficiently high to allow secondary effects in altimetric and bottom-pressure tide differences to be studied. The atmospheric tide in bottom pressure is clearly detected at the S1, S2, and T2 frequencies. The altimetric tide model is improved if satellite altimetry is corrected for crustal loading by the atmospheric tide. Models of the solid body tide can also be constrained. The free corenutation effect in the K1 Love number is easily detected, but the overall estimates are not as accurate as a recent determination with very long baseline interferometry.

tides↗

A Preliminary Study of a Novel Heat Pump Integrated Underground Thermal Energy Storage for Shaping Electric Demand of Buildings

A Dual-Purpose Underground Thermal Battery (DPUTB) innovatively integrates a ground heat exchanger with underground thermal energy storage. The DPUTB can be integrated with an Electric-Driven Heat Pump (EDHP) to enable more flexible electric load for meeting the thermal demands of a building (e.g., space cooling and space heating). A one-dimensional numerical model of the DPUTB is developed and validated against measured performance data of a small-scale DPUTB prototype. The validated DPUTB model is integrated with a heat pump model and a building energy simulation model to predict the load shifting performance and energy consumption of an integrated EDHP and DPUTB system. Preliminary simulation results indicate that the integrated system can flatten the electric load profile of a typical residential building and reduce the electric demand during peak hours by 37% on a typical summer day. In addition, the integrated EDHP and DPUTB system also reduces the daily power consumption of the building by 11% compared with a conventional residential space heating and cooling system.

Liu, Xiaobing↗

Charge transport model in nanodielectric composites based on quantum tunneling mechanism and dual-level traps

Charge transport properties in nanodielectrics present different tendencies for different loading concentrations. The exact mechanisms that are responsible for charge transport in nanodielectrics are not detailed, especially for high loading concentration. A charge transport model in nanodielectrics has been proposed based on quantum tunneling mechanism and dual-level traps. In the model, the thermally assisted hopping (TAH) process for the shallow traps and the tunnelling process for the deep traps are considered. For different loading concentrations, the dominant charge transport mechanisms are different. The quantum tunneling mechanism plays a major role in determining the charge conduction in nanodielectrics with high loading concentrations. While for low loading concentrations, the thermal hopping mechanism will dominate the charge conduction process. The model can explain the observed conductivity property in nanodielectrics with different loading concentrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine Learning of Commercial and Residential Load Components in Northwestern United States

The impacts of weather attributes on commercial and residential electricity demands and their components in the northwestern United States were examined. Two machine learning methods, regression tree (RT), and random forest (RF), were integrated and compared. Both RT and RF models provide reliable prediction of commercial cooling load. RF models particularly yield higher accuracy with reduced overfitting.

Zhou, Huifen↗

Integrating External Resources with a Task-Based Programming Model

Accessing external resources (e.g., loading input data, checkpointing snapshots, and out-of-core processing) can have a significant impact on the performance of supercomputer applications. However, no existing programming systems for high-performance computing directly manage and optimize these external accesses. As a result, users must explicitly manage external accesses alongside their computation at the application level, which can result in both correctness and performance issues. We address this limitation by introducing Iris, a task-based programming model with semantics for external resources. Iris allows applications to describe their access requirements to external resources and the relationship of those accesses to the computation. Iris incorporates external I/O into a deferred execution model, reschedules external I/O to overlap I/O with computation, and reduces external I/O when possible. We evaluate Iris on three microbenchmarks representative of important workloads in HPC and a full combustion simulation, S3D. We demonstrate that the Iris implementation of S3D reduces the external I/O overhead by up to 20×, compared to the Legion and the Fortran implementations.

97 MATHEMATICS AND COMPUTING↗

Constrained model calibration of grain structure dependent spall dynamics in shock-loaded tantalum

Here, we perform a gas gun experiment by shock loading tantalum samples of varying grain structures to assess the suitability of a numerical model for simulating spall behavior. The observed differences in spall strength, as well spallation and re-compression history, are not captured in uncalibrated hydrodynamic simulations. An optimization is performed on the Johnson spall model to determine the best parameters that fit the observed trends. Linear stability analysis is employed to motivate bounds on those parameters. Herein, optimized simulations agree well with the experimental results, reproducing pullback depth and recompression timescales across the different samples tested. Further, the observed pullback time of the single crystal sample was found to imply, via the stability analysis, a percolation threshold in good agreement with the theoretical value for a body centered cubic lattice. Therefore, the combined linear stability and percolation analysis shows promise and may be applied to other materials with diverse microstructures. Collectively, the findings demonstrate that the model is suitable for reproducing spall-induced free surface behavior across various microstructures, but also points to caution in using model coefficients for uncalibrated microstructures.

58 GEOSCIENCES↗

High Strain Rate Response of Adhesively Bonded Fiber-Reinforced Composite Joints – A Computational Study to Guide Experimental Design

Adhesively bonded carbon fiber-reinforced epoxy composite laminates are widely used in aerospace applications. During a high energy impact event, these laminates are often subjected to high strain rate loading. However, the influence of high strain rate loading on the response of these composite joints is not well understood. Computational finite element (FE) modeling and simulations are conducted to guide the design of high strain rate experiments. Two different experimental designs based on split Hopkinson bar were numerically modeled to simulate Mode I and Mode II types loading in the composite. In addition, the computational approach adopted in this study helps in understanding the high strain rate response of adhesively bonded composite joints subjected to nominally Mode I and Mode II loading. The modeling approach consists of a ply-level 3D FE model, a progressive damage constitutive model for the composite material behavior and a cohesive tie-break contact element for interlaminar delamination.

Ravindran, Suraj↗