Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOS ALAMOS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

A liquid VI scintillator cell for fast-gated neutron imaging

Here, the design of a new fast-gated neutron imaging system for the National Ignition Facility with much stricter timing constraints than a previous system has prompted the search for a fast scintillator material that can be used in imaging. A novel imaging cell based on Liquid VI has recently been developed with Eljen Technology and characterized at the Special Technologies Laboratory and the Los Alamos Neutron Science Center. The results show superior timing characteristics and spatial resolution, and sufficient light production for the new system compared to fast plastic scintillators previously used in neutron imaging. While the primary application is in inertial confinement fusion diagnostics, the imaging cell can be used in any fast-gated imaging application where timing characteristics and spatial resolution are of concern.

47 OTHER INSTRUMENTATION↗

Gallium nitride (GaN) devices as a platform technology for radiation hard inertial confinement fusion diagnostics

Inertial Confinement Fusion (ICF) is undergoing more detailed research to increase neutron yield and will require high resolution imaging near the target. Neutron damage to diagnostics remains a serious issue in understanding and achieving ICF. We have demonstrated that Gallium Nitride (GaN) optoelectronic devices have exceptional neutron radiation hardness, by systematic testing of neutron radiation effects in GaN devices and materials with elevated neutron fluence levels and a broad neutron energy spectrum. During the 2013-2017 run cycles at Los Alamos Neutron Science Center (LANSCE), we irradiated various GaN materials and devices with fast and thermal plus resonance neutrons at several beamlines. This work presents a radiation hardness study for Aluminum Gallium Nitride and Gallium Nitride (AlGaN/GaN) deep UV LEDs irradiated at the LANSCE 4FP60R beamline. The fluence level was up to 2.4 × 10 13 neutrons/cm 2 for neutrons with energies greater than 0.1 MeV. The device performance was monitored in real time. After three years of irradiation studies, we found that the GaN devices maintained operation in the forward active region. The current and voltage relation (I-V curves) varied insignificantly in the linear region. Finally, our results demonstrate the radiation hardness needed for laser fusion diagnostics at least up to 10 17 neutron yield per shot, if the diagnostics is placed 1 m away from the target, where the neutron fluence per shot is approximately 8 × 10 11 n/cm 2 . The GaN devices can operate for multiple shots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One dimensional shock initiation of hot isostatically pressed composition B

Twelve one dimensional shock experiments have been carried out on the UK isostatically pressed Composition B (59.5% RDX, 39.5% TNT, 1% wax) comprising of seven sustained pulse experiments and three short shock experiments using the embedded gauge technique at the Los Alamos National Laboratory gas gun facility. The evolution of the reactive growth at and behind the shock front has been measured along with the run to detonation distance. Two low pressure experiments have also been carried out to obtain non-reactive equation of state data. These data have been used to create the Pop plot and Hugoniot states for the UK Comp B. The shock initiation behavior of the UK Comp B has been compared to that of the equivalent US composition. The reactive growth shows a feature that was observed in the US composition in which the wave profiles display a high level of pre-detonation noise. This was hypothesized to be due to a piezoelectric effect in the RDX crystals. The results of these experiments have shown that this effect may be localized in the ε phase at shock pressures in the region of 4.15 GPa and above.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling of direct-drive cylindrical implosion experiments with an Eulerian radiation-hydrodynamics code

Recent improvements to xRAGE, Los Alamos National Laboratory's Eulerian radiation-hydrodynamics code, have enabled the computation of laser-driven experiments relevant to inertial confinement fusion and high energy density physics. Here, previous directly driven cylindrical implosion experiments are modeled in order to benchmark xRAGE design simulations for future cylindrical implosion experiments, representing the first attempt to model such systems with an Eulerian code with adaptive mesh refinement. Simulations in 2D of transverse and axial cross-sections of the cylindrical target are performed, and the results are combined to form a 3D representation of the imploding cylinder. Synthetic radiographs are produced and analyzed from the simulation results, allowing for a direct comparison with experimentally measured quantities. The zeroth-order hydrodynamic trajectories of targets with no specified initial perturbation are well matched by the computations. Simulations of targets with a preimposed sinusoidal perturbation in the azimuthal direction show single-mode instability growth that is in agreement with the available data, but higher fidelity experimental measurements are required to enable more detailed comparisons. As a result, the mode growth observed in computations compares favorably with predictions of a linear theory for the ablative Rayleigh-Taylor instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonant ultrasound spectroscopy: The essential toolbox

Resonant Ultrasound Spectroscopy (RUS) is an ultrasound-based minimal-effort high-accuracy elastic modulus measurement technique. RUS as described here uses the mechanical resonances (normal modes of vibration or just modes) of rectangular parallelepiped or cylindrical specimens with a dimension of from a fraction of a millimeter to as large as will fit into the apparatus. Provided here is all that is needed so that the reader can construct and use a state-of-the-art RUS system. Included are links to open-source circuit diagrams, links to download Los Alamos National Laboratory open-source data acquisition software, links to request free analysis software, procedures for acquiring measurements, considerations on building transducers, 3-D printed stage designs, and a full mathematical explanation of how the analysis software extracts elastic moduli from resonances.

47 OTHER INSTRUMENTATION↗

Angular scattering of protons through ultrathin graphene foils: Application for time-of-flight instrumentation

Space plasma instruments often rely on ultrathin carbon foils for incident ion detection, time-of-flight (TOF) mass spectrometry, and ionization of energetic neutral atoms. Angular scattering and energy loss of ions or neutral atoms in the foil can degrade instrument performance, including sensitivity and mass resolution; thus, there is an ongoing effort to manufacture thinner foils. Using new 3-layer graphene foils manufactured at the Los Alamos National Laboratory, we demonstrate that these are the thinnest foils reported to date and discuss future testing required for application in space instrumentation. We characterize the angular scattering distribution for 3–30 keV protons through the foils, which is used as a proxy for the foil thickness. We show that these foils are ~2.5–4.5 times thinner than the state-of-the-art carbon foils and ~1.6 times thinner than other graphene foils described in the literature. We find that the inverse relationship between angular scattering and energy no longer holds, reaffirming that this may indicate a new domain of beam–foil interactions for ultrathin (few-layer) graphene foils.

47 OTHER INSTRUMENTATION↗

Fast strength model characterization using Bayesian statistics

A variety of flow stress models exist with new models constantly being developed. These models aim to approximate the strength of materials in a variety of regimes from quasistatic loading through shock scenarios. All models contain an array of parameters which need to be tuned to the material under study. Some models perform well under limited conditions, requiring adjustment of the parameters when venturing outside of those predefined ranges. Other models perform well over a wide range of conditions with a set of parameters, but may be outperformed by other models optimized on a tighter range of conditions. Recent research by Los Alamos demonstrated the ability to optimize the Johnson Cook (JC) model using a set of 3 plate-impact experiments on Aluminum. They utilized Bayesian statistics and emulation to determine optimal parameters for the model with a quantification of parameter uncertainty. We present an extension of this capability to incorporate velocimetry from plate-impact tests, stress-strain data from split Hopkinson pressure bar and quasistatic compression tests, plus profiles from Taylor cylinders in a unified fashion. Statistically robust comparisons of the performance and uncertainty of different realizations of the JC flow stress model were carried out based on calibration to several possible combinations of these three different experiment types.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Overdriven-detonation states produced by spherically diverging waves

A series of experiments are currently underway at the Detonation Science and Technology group, within Los Alamos National Laboratory, to study the overdriven-detonation states achievable in energetic materials as a result of detonation-wave interactions. A multi-component, energetic-material array was designed to study the amplification of velocity and pressure states produced by spherically diverging detonation waves in pentaerythritol tetranitrate (PETN) output charges. The unique geometry provides a low-jitter, highly controlled series of interactions between three independent-detonation inputs. Streak-camera imaging was performed on the output face of PETN pellets ranging in thickness from 2.5 – 10 mm to characterize the resulting breakout profile. Additionally, photonic Doppler velocimetry (PDV) measurements were collected at the output-pellet surface to determine simultaneity within the system. Detonation-wave velocities upwards of 16 mm/µs were measured, as compared to a steady-state detonation velocity of 7.9 mm/µs for the PETN pressing density investigated. Finally, additional experiments are being conducted to measure the pressure amplification generated at key areas of interaction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Equation of state for 304L stainless steel

Here, a new equation of state for 304L stainless steel has been constructed and entered in the Los Alamos National Laboratory SESAME database with material ID 4273. The equation of state is based on a multiphase approach. The solid and liquid phases were fitted to available experimental data for thermal expansion, heat capacity, and shock Hugoniot, as well as to data from density functional theory calculations of the cold curve and quantum molecular dynamics of the liquid regime. The electronic thermal contribution over the entire equation of state range is based on Tartarus (Green’s functions) average atom calculations. For this low-carbon stainless steel both the density functional and electronic thermal calculations are comprised of 19 wt% Cr, 10 wt% Ni, and the remainder Fe.

36 MATERIALS SCIENCE↗

Insight into the chemistry of TNT during shock compression through ultrafast absorption spectroscopies

Thin films of trinitrotoluene (TNT) were shock compressed using the ultrafast laser shock apparatus at Los Alamos National Laboratory. Visible (VIS) and mid-infrared (MIR) transient absorption spectroscopies were simultaneously performed to probe for electronic and vibrational changes during shock compression of TNT. Additionally, three shock pressures (16 GPa, 33 GPa, and 45 GPa) were selected to observe no reaction, incipient reaction, and strongly developed reactions for TNT within the experimental time scale of <250 ps. Negligible absorption changes in MIR or VIS absorptions were observed at 16 GPa. At 33 GPa, MIR absorptions in the 3000 cm -1 –4000 cm -1 range were observed to increase during the shock and continue to increase during the rarefaction, in contrast to the VIS absorption measurements, which increased during the shock and almost fully recovered during rarefaction. At 45 GPa, both VIS and MIR absorptions were strong and irreversible. The intense and spectrally broad MIR absorptions were attributed to short lived intermediates with strong, spectrally broad absorptions that dominate the spectral response. The MIR and VIS absorption changes observed at 33 GPa and 45 GPa were credited to shock induced chemistry, most likely including the formation of a very broad hydrogenic stretch feature. The results from these experiments are consistent with the chemical mechanisms that include O–H or N–H formation such as CH 3 oxidation or C–N homolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

Neutron radiation hardness of aluminum gallium nitride UV LEDs at various wavelengths

Radiation hard diagnostics are critical to the success of nuclear fusion at National Ignition Facility, Z, ITER, and prolonged space explorations. We have first demonstrated the exceptional proton radiation hardness of initial GaN devices and qualified their space flight and deployment for missions such as the Laser Interferometer Space Antenna and International Space Station. We have further conducted neutron radiation hardness experiments at Los Alamos Neutron Science Center by opening a new high fluence beam station. During 2014–2016, we irradiated multiple Aluminum Gallium Nitride (AlGaN) LEDs with a maximum fluence of 2.4 × 1013 neutrons/cm2 in 3 years and generated 54 161 current–voltage (I–V) scan traces. Our data processing program analyzes each and all I–V traces. In addition, we retrieved local temperature records to analyze and remove temperature effects in the outdoor environment. The I–V curve families of AlGaN UV LEDs with emitting wavelengths of 265, 275, and 310 nm were compared. The I–V curves of 265 nm AlGaN UV LEDs have the smallest deviations from the average value, while the I–V curves for 310 nm AlGaN LEDs showed the largest deviations from the average value. We have reached another important recommendation for the optimal use of multiple AlGaN optoelectronic devices or imaging arrays for inertially confined fusion diagnostics: Shorter wavelength devices at 265 nm exhibit more consistent radiation hardness performance than the 310 nm devices. Higher aluminum content LEDs or AlxGa1–xN devices with higher mole fraction x for generating shorter wavelengths have better radiation hardness for fusion diagnostics.

Sun, K. -X. (ORCID:0000000224659235)↗

Improved imaging using Mn He- α x rays at OMEGA EP

In this paper, we report on a crystal based x-ray imaging system fielded at the OMEGA EP laser facility. This new system has a pointing accuracy of +/100 μm, a temporal resolution down to 100 ps (depending on backlighter characteristics), variable magnification, and a spatial resolution of 21.9 µm at the object plane at a magnification of 15×. The system is designed to use a crystal along the crystal plane that satisfies the Bragg condition for the x ray of interest. The thin crystal is then bent into a spherical geometry and attached to a glass backing substrate to hold it in the diagnostic, and the x rays are imaged onto a charge coupled device. We report on data acquired with the new Los Alamos National Laboratory supplied spherical quartz crystal to image the Mn He-α 6.15 keV line emission.

Fiedler Kawaguchi, C. (ORCID:0000000175522370)↗

Modeling of tungsten filament in gas discharge in H - ion source

Sources of negative ions such as H - are essential elements of proton accelerators and tokamaks. They have limited lifetime. The replacement of an ion source is a costly process causing delays in the operation of the entire machine. The hot tungsten filament is the key element that limits the lifetime of the H - ion source at the Los Alamos Neutron Science Center (LANSCE) facility. An accurate model, which describes the filament physics and provides a reliable estimate on its lifetime, may significantly improve the operation of the facility. In this report we describe such a model, including a comprehensive list of relevant physical processes from first principles. The model can be used to describe different regimes of operation using diagnostics data as input parameters. It has been benchmarked against the data collected during the production cycle at LANSCE and shows good agreement with experimental data.

47 OTHER INSTRUMENTATION↗

Preface to the Proceedings of the 23rd Topical Conference on High-Temperature Plasma Diagnostics

Measurements of phenomena advance our understanding of the physical universe. As our understanding grows, more precise measurements are required, as are measurements of new quantities. Diagnosis of a plasma requires developing new instruments, also called diagnostics, as well as new ways to analyze, interpret, synthesize, and correlate their measurements. Further, as computing power increases and multi-physics codes improve their accuracy, more precise measurements are needed to guide future code developments and to validate predictions of these simulation codes. The Topical Conference on High-Temperature Plasma Diagnostics is focused on presenting and documenting the most recent advances in these instrumentation areas for plasmas. The 23rd occurrence of this biennial conference took place on December 14–17, 2020, and was hosted by Los Alamos National Laboratory. Originally scheduled for June 2020 in Santa Fe, New Mexico, the conference was postponed and then held virtually due to the global COVID-19 pandemic. Conference times were adjusted and presentations were scheduled to meet the needs of attendees in Europe, the USA, and Asia.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A mathematical framework for ejecta cloud dynamics with application to source models and piezoelectric mass measurements

We present a mathematical framework for describing the dynamical evolution of an ejecta cloud generated by a generic ejecta source model. We consider a piezoelectric sensor fielded in the path of an ejecta cloud, for experimental configurations in which the ejecta are created at a singly shocked planar surface and fly ballistically through vacuum to the stationary sensor. To do so, we introduce the concept of a time- and velocity-dependent ejecta “areal mass function.” We derive expressions for the analytic (“true”) accumulated ejecta areal mass at the sensor and the measured (“inferred”) value obtained via the standard method for analyzing piezoelectric voltages. In this way, we derive an exact expression and upper bound for the error imposed upon a piezoelectric ejecta mass measurement (in a perfect system) by the assumption of instantaneous creation, which is commonly required for momentum diagnostic analyses. This error term is zero for truly instantaneous source models; otherwise, the standard piezoelectric analysis is guaranteed to overestimate the true mass. When combined with a piezoelectric dataset, this framework provides a unique solution for the ejecta particle velocity distribution, subject to the assumptions inherent in the data analysis. The framework also leads to strong boundary conditions that any ejecta source model must satisfy in order to be consistent with apparently global properties of piezoelectric measurements from a wide range of experiments. We demonstrate this methodology by applying it to the Richtmyer–Meshkov instability+self-similar velocity distribution ejecta source model currently under development at Los Alamos National Laboratory.

97 MATHEMATICS AND COMPUTING↗

Bringing discrete-time Langevin splitting methods into agreement with thermodynamics

In light of the recently published complete set of statistically correct Grønbech–Jensen (GJ) methods for discrete-time thermodynamics, we revise a differential operator splitting method for the Langevin equation in order to comply with the basic GJ thermodynamic sampling features, namely, the Boltzmann distribution and Einstein diffusion, in linear systems. This revision, which is based on the introduction of time scaling along with flexibility of a discrete-time velocity attenuation parameter, provides a direct link between the ABO splitting formalism and the GJ methods. This link brings about the conclusion that any GJ method has at least weak second order accuracy in the applied time step. It further helps identify a novel half-step velocity, which simultaneously produces both correct kinetic statistics and correct transport measures for any of the statistically sound GJ methods. Explicit algorithmic expressions are given for the integration of the new half-step velocity into the GJ set of methods. Finally, numerical simulations, including quantum-based molecular dynamics (QMD) using the QMD suite Los Alamos Transferable Tight-Binding for Energetics, highlight the discussed properties of the algorithms as well as exhibit the direct application of robust, time-step-independent stochastic integrators to QMD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shock initiation of low density polymer bonded explosive LX-14: A study of two morphologies

A series of six shock initiation experiments have been carried out on low density LX-14 powder in order to simulate a shock insult on the heavily damage polymer bonded explosive, LX-14. Two distinct morphologies were studied (tap density molding powder and machined swarf), both at the same density of 0.942 g/cm 3 , or 50.1% theoretical maximum density. The purpose of these experiments was to provide data to help make an assessment of the effects that damage has on the material sensitivity to a planar shock. This was achieved primarily by providing shock sensitivity data in the form of a Pop plot, and also reactants equation of state data, which aids in the determination of input conditions for both the experiments performed in this work and also future experiments of this material type. The experiments were of a cut-back format, consisting of four sample heights on each shot and diagnosed with optical velocimetry. The experiments were carried out at the Technical Area 40 Chamber 9 gas gun facility at the Los Alamos National Laboratory, where the LX-14 targets were subjected to Al 6061 and Oxygen Free High Conductivity copper impactors launched to velocities up to 2.14 km/s. Time corrected reactive growth wave profiles are presented in this paper along with the derivation of the following Hugoniot parameters for this explosive, where the molding powder and machine swarf are represented by the following linear equations, respectively, U s = 1.64 (±0.64)u p + 2.25 (±0.49) and U s = 0.87 (±.0.60)u p + 4.08 (±0.49). The results show that the steady increase in shock sensitivity with increasing void fraction reaches an inflection point beyond which the shock sensitivity begins to decease. This inflection point lies between 65% and 50% of the theoretical maximum density of the LX-14. In both cases, the damaged LX-14 was not as sensitive as expected, with a relative shock sensitivity of the molding powder being less than the pressed LX-14, and the machined swarf having a shock sensitivity that is comparable to pressed LX-14.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗