DOE OSTI · 1822486
Improved imaging using Mn He- α x rays at OMEGA EP
Abstract
In this paper, we report on a crystal based x-ray imaging system fielded at the OMEGA EP laser facility. This new system has a pointing accuracy of +/100 μm, a temporal resolution down to 100 ps (depending on backlighter characteristics), variable magnification, and a spatial resolution of 21.9 µm at the object plane at a magnification of 15×. The system is designed to use a crystal along the crystal plane that satisfies the Bragg condition for the x ray of interest. The thin crystal is then bent into a spherical geometry and attached to a glass backing substrate to hold it in the diagnostic, and the x rays are imaged onto a charge coupled device. We report on data acquired with the new Los Alamos National Laboratory supplied spherical quartz crystal to image the Mn He-α 6.15 keV line emission.
Keep this discovery
Explore connections, maps & timelines
Fiedler Kawaguchi, C. (ORCID:0000000175522370), Flippo, K. A. (ORCID:0000000247525141), Rasmus, A. M., Tobias, B., Byvank, T., Di Stefano, C. A. (ORCID:0000000161663519), Merritt, E. C. (ORCID:0000000290260070), Doss, F. W. (ORCID:0000000307296257), Kelso, K. V., Vazirani, N. N., Stoeckl, C. (ORCID:0000000153755800), Bedzyk, M., Jungquist, R. (ORCID:0000000302690685), Mileham, C.. 2021-09-28. Improved imaging using Mn He- α x rays at OMEGA EP. https://doi.org/10.1063/5.0045704
Cite the original work for its findings. Save a collection to share your selection of sources.