Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOOSTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Changes in serum-neutralizing antibody potency and breadth post-SARS-CoV-2 mRNA vaccine boost

A better understanding of the durability and breadth of serum-neutralizing antibody responses against multiple severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants elicited by COVID-19 vaccines is crucial in addressing the current pandemic. In this study, we quantified the decay of serum neutralization antibodies (nAbs) after second and third doses of the original COVID-19 mRNA vaccine. Using an authentic virus-neutralization assay, we found that decay half-lives of WA1- and Delta-nAbs were both ~60 days after second and third vaccine dose. Unexpectedly, the durability of serum antibodies that neutralize three different Omicron subvariants (BA.1.1, BA.5, BA.2.12.1) was substantially better, with half-lives of ≥6 months. A booster dose of the original COVID-19 vaccine was also found to broaden antibody responses against SARS-CoV and four other sarbecoviruses, in addition to multiple SARS-CoV-2 strains. These findings suggest that repeated vaccinations with the COVID-19 vaccine may confer a degree of protection against future spillover of sarbecoviruses from animal reservoirs.

59 BASIC BIOLOGICAL SCIENCES↗

Pulse superimposition calculational methodology for estimating the subcriticality level of nuclear fuel assemblies.

One of the most reliable experimental methods for measuring the subcriticality level of a nuclear fuel assembly is the Sjoestrand method applied to the reaction rate generated from a pulsed neutron source. This study developed a new analytical methodology simulating the Sjoestrand method, which allows comparing the experimental and analytical reaction rates and the obtained subcriticality levels. In this methodology, the reaction rate is calculated due to a single neutron pulse using MCNP/MCNPX computer code or any other neutron transport code that explicitly simulates the delayed fission neutrons. The calculation simulates a single neutron pulse over a long time period until the delayed neutron contribution to the reaction rate is vanished. The obtained reaction rate is then superimposed to itself, with respect to the time, to simulate the repeated pulse operation until the asymptotic level of the reaction rate, set by the delayed neutrons, is achieved. The superimposition of the pulse to itself was calculated by a simple C computer program. A parallel version of the C program is used due to the large amount of data being processed, e.g., by the Message Passing Interface (MPI). The analytical results of this new calculation methodology have shown an excellent agreement with the experimental data available from the YALINA-Booster facility of Belarus. This methodology can be used to calculate Bell and Glasstone spatial correction factor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A state of the art current-septum dipole magnet

Here, the acceleration process of charged particle beams often requires the use of few acceleration stages to provide the beam with the desired energy. The extraction of the beam from one acceleration stage and the injection to the next, both require a special type of magnet which comes under the name septum magnet. Such a magnet generates a strong field in one region and a very low field in another region with the two regions separated by a very thin material (septum). The septum thickness of such a magnet should be as thin as possible to reduce the strength of other devices, like kickers, which are involved in the extraction or injection processes. A thin septum is also advantageous during the slow beam extraction process to reduce the beam losses at the septum. One of the methods which in theory can generate very large differences in field strength in adjacent field regions separated by a thin septum, is the use of two thin parallel current sheets of infinite dimensions. In practice we use other devices that can approximate such an abrupt change of the magnetic field within the septum thickness. In this paper we describe such a device, the DC current septum, we present results from the study of its electromagnetic properties, and we discuss a method to minimize the magnetic field in the region which requires a very small magnetic field. We also provide some results from the experimental measurements of the magnetic field generated by the D6 current septum magnet which is installed in the experimental beam line of the NASA’s Space Radiation Laboratory (NSRL) facility [1],[2] at Brookhaven National Laboratory (BNL). This septum magnet is part of the beam’s extraction system from the AGS-Booster into the NSRL beam line for material and biological studies.

43 PARTICLE ACCELERATORS↗

Space-charge effects in ionization beam profile monitors

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. At high beam intensities, the space-charge forces make the measured IPM profiles significantly different from those of the beams. We analyze dynamics of the secondaries in IPMs and develop an effective algorithm to reconstruct the beam sizes from the measured IPM profiles. Efficiency of the developed theory is illustrated in application to the Fermilab 8 GeV proton Booster IPMs.

43 PARTICLE ACCELERATORS↗

The scintillation light detection system of ICARUS-T600: Hardware implementation and early results

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is taking data with the Fermilab Booster Neutrino Beam-line (BNB) in the Short Baseline Neutrino (SBN) program to search for a possible LSND-like sterile neutrino signal. A light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs) deployed behind the TPC wire chambers, has been realized to detect vacuum ultraviolet (VUV) photons produced by ionizing particles in LAr. This system is fundamental for the detector operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the TPC is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the beam spill gates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronic set-up for the scintillation light detection system of ICARUS-SBN at Fermilab

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible sterile neutrino signal with the Booster Neutrino Beam (BNB). We discuss a light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs), which has been realized to detect vacuum ultraviolet (VUV) photons produced after the passage of ionizing particles in LAr. High performance electronics allows recording of the PMT signals and provides a fast discrimination for the exploitation of the scintillation light for trigger purposes. This system is fundamental for the TPC operation, contributing to the trigger system and for the 3D reconstruction of events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal evaluation of uranium silicide miniplates irradiated at high heat flux

The Gas Test Loop (GTL)-1 irradiation experiment was conducted in the Advanced Test Reactor (ATR) to assess corrosion performance of proposed booster fuel at heat flux levels ~30% above the design operating condition. Sixteen miniplates fabricated from 25% enriched, high-density (4.8 g U/cm3) U3Si2/Al dispersion fuel with 6061 aluminum cladding were subjected to peak beginning of cycle (BOC) heat fluxes ranging from 411 to 593 W/cm2. No adverse impacts to the miniplates were observed at these high heat flux levels. A detailed finite element model was constructed to calculate temperatures and heat flux for an as-run cycle average effective ATR south lobe power of 25.4 MW(t). Miniplate heat flux levels and fuel, cladding, hydroxide, and coolant–hydroxide interface temperatures were calculated using the average hydroxide thickness on each miniplate measured during post-irradiation examination. The purpose of this study was to obtain a best estimate of the as-run experiment temperatures to aid in establishing acceptable heat flux levels and designing fuel qualification experiments for this fuel type.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The NOvA experiment at FNAL, status and perspectives

The NO$\nu$A experiment is a new long baseline neutrino experiment designed to measure $\theta_{13}$ through the appear- ance of $\nu_e$ in a $\nu_\mu$ beam, at an off-axis angle of 14 mrad. The NO$\nu$A experiment has constructed and instrumented their near detector and has begun taking data in a surface location that places the detector in both the Neutrinos at the Main Injector (NuMI) neutrino beam and booster neutrino beam at Fermilab. This location provides significant neutrino fluxes for studies of both $\nu_{e}$ and $\nu_\mu$ interactions and for understanding of the detector response to both types of interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Dark Matter Searches by Measuring the Nucleon Axial Form Factor: Perspectives from MicroBooNE

The MicroBooNE neutrino experiment at Fermilab is constructing a liquid-argon time-projection chamber for the Booster Neutrino Beam to study neutrino oscillations and interactions with nucleons and nuclei, starting in 2014. We describe the experiment and focus on its unique abilities to measure cross sections at low values of $Q^2$. In particular, the neutral-current elastic scattering cross section is especially interesting, as it is sensitive to the contribution of the strange sea quark spin to the angular-momentum of the nucleon, $\Delta s$. Implications for dark-matter searches are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of three-dimensional inclusive muon-neutrino charged-current cross sections on argon with the MicroBooNE detector

We report the measurement of the triple-differential cross section d 3 σ/dE vis d cos(θ μ )dP μ for inclusive muon-neutrino charged-current scattering on argon. This measurement utilizes data from 6.4 x 10 20 protons on target of exposure collected using the MicroBooNE liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam with a mean neutrino energy of approximately 0.8 GeV. The mapping from reconstructed kinematics to truth quantities is validated within uncertainties by comparing the distribution of reconstructed hadronic energy in data to that of the model prediction in different muon scattering angle bins after applying a conditional constraint from the muon momentum distribution in data. The success of this validation provides confidence that the energy transfer in the MicroBooNE detector is well-modeled within simulation uncertainties, enabling a reliable unfolding to a triple-differential cross section defined at the nominal neutrino flux over muon momentum, muon scattering angle, and visible neutrino energy. This validation not only supports accurate cross-section extraction, but also establishes a critical foundation for tuning interaction models used in future neutrino oscillation measurements. The unfolded measurement covers an extensive phase space, providing a wealth of information useful for future liquid argon time projection chamber experiments measuring neutrino oscillations. Comparisons against a number of commonly used model predictions are included and their performance in different parts of the available phase-space is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutralization escape by SARS-CoV-2 Omicron subvariant BA.2.86

The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) variant BA.2.86 has over 30 mutations in spike compared with BA.2 and XBB.1.5, which raised the possibility that BA.2.86 might evade neutralizing antibodies (NAbs) induced by vaccination or infection. In this study, we show that NAb titers are substantially lower to BA.2.86 compared with BA.2 but are similar or slightly higher than to other current circulating variants, including XBB.1.5, EG.5.1, and FL.1.5.1. Moreover, NAb titers against all these variants were higher in vaccinated individuals with a history of XBB.1.5 infection compared with vaccinated individuals with no history of XBB.1.5 infection, suggesting the potential utility of the monovalent XBB.1.5 mRNA boosters.

60 APPLIED LIFE SCIENCES↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A multi-phase, micro-dispersion reactor for the continuous production of methane gas hydrate

A continuous-jet hydrate reactor originally developed to generate a CO2 hydrate stream has been modified to continuously produce CH4 hydrate. The reactor has been tested in the Seafloor Process Simulator (SPS), a 72-L pressure vessel available at Oak Ridge National Laboratory. During experiments, the reactor was submerged in water inside the SPS and received water from the surrounding through a submersible pump and CH4 externally through a gas booster pump. Thermodynamic conditions in the hydrate stability regime were employed in the experiments. The reactor produced a continuous stream of CH4 hydrate, and based on pressure values and amount of gas injected, the conversion of gas to hydrate was estimated. A conversion of up to 70% was achieved using this reactor.

03 NATURAL GAS↗

Search for light sterile neutrinos with two neutrino beams at MicroBooNE

The existence of three distinct neutrino flavours, ν e , ν μ and ν τ , is a central tenet of the Standard Model of particle physics. Quantum-mechanical interference can allow a neutrino of one initial flavour to be detected sometime later as a different flavour, a process called neutrino oscillation. Several anomalous observations inconsistent with this three-flavour picture have motivated the hypothesis that an additional neutrino state exists, which does not interact directly with matter, termed as ‘sterile’ neutrino, ν s . This includes anomalous observations from the Liquid Scintillator Neutrino Detector (LSND)3 experiment and Mini-Booster Neutrino Experiment (MiniBooNE), consistent with ν μ → ν e transitions at a distance inconsistent with the three-neutrino picture. Here we use data obtained from the MicroBooNE liquid-argon time projection chamber in two accelerator neutrino beams to exclude the single light sterile neutrino interpretation of the LSND and MiniBooNE anomalies at the 95% confidence level (CL). Moreover, we rule out a notable portion of the parameter space that could explain the gallium anomaly. This is one of the first measurements to use two accelerator neutrino beams to break a degeneracy between ν e appearance and disappearance, which would otherwise weaken the sensitivity to the sterile neutrino hypothesis. We find no evidence for either ν μ → ν e flavour transitions or ν e disappearance that would indicate non-standard flavour oscillations. Our results indicate that previous anomalous observations consistent with ν μ → ν e transitions cannot be explained by introducing a single sterile neutrino state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]↗

Intense beam production of highly charged heavy ions by the superconducting electron cyclotron resonance ion source SECRAL (invited)

There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e {mu}A of O{sup 7+}, 505 e {mu}A of Xe{sup 20+}, 306 e {mu}A of Xe{sup 27+}, and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

43 PARTICLE ACCELERATORS↗

The SciBooNE Data Acquisition System

SciBooNE started in June 2007 primarily to study neutrino and anti-neutrino interactions in the energy region below 1 GeV. The SciBooNE detector is located in Booster Neutrino Beamline at Fermi National Accelerator Laboratory. The SciBooNE data aquisition system consists of the readout software and an event builder, which collects data from each detector component (SciBar detector, an electromagnetic calorimeter, Muon Range Detector and GPS). The typical DAQ readout time per trigger is 20 ms, which is fast enough to take every beam spill. The system is also very stable and the probability of missing a beam spill due to the readout time is less than 0.002 %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗