Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIZE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Insights Into the Size-Resolved Dust Emission From Field Measurements in the Moroccan Sahara

The particle size distribution (PSD) of mineral dust has a strong effect on the impacts of dust on climate. However, our understanding of the emitted dust PSD, including its variability and the fraction of super-coarse dust (diameter >10 µm), remains limited. Here, we provide new insights into the size-resolved dust emission process based on a field campaign performed in the Moroccan Sahara in September 2019 in the context of the FRontiers in dust minerAloGical coMposition and its Effects upoN climaTe (FRAGMENT) project. The obtained dust concentration and diffusive flux PSDs show significant dependencies upon the friction velocity (u*), wind direction and type of event (regular events versus haboob events). For instance, the number fraction of sub-micrometre particles increases with u*, along with a large decrease in the mass fraction of super-coarse dust. We identify dry deposition, which is modulated by u* and fetch length, as a potential cause for this PSD variability. Using a resistance model constrained with field observations to estimate the dry deposition flux and thereby also the emitted dust flux, we show that deposition could represent up to ∼90 % of the emission of super-coarse particles (>10 µm) and up to ∼65 % of the emission of particles as small as ∼5 µm in diameter. Importantly, removing the deposition component significantly reduces the variability with u* in the PSD of the emitted dust flux compared with the diffusive flux, particularly for super-coarse dust. The differences between regular and haboob event concentration and diffusive flux PSDs are suspected to result from a smaller and variable dust source fetch during the haboob events, and/or an increased resistance of soil aggregates to fragmentation associated with the observed increase in relative humidity along the haboob outflow. Finally, compared to the invariant emitted dust flux PSD estimated based on brittle fragmentation theory, we obtain a substantially higher proportion of super-micrometre particles in the dust flux. Overall, our results suggest that dry deposition needs to be adequately considered to estimate the emitted PSD, even in studies limited to the fine and coarse size ranges (<10 µm).

particle size distribution↗

Humans to Mars, but How Many? Using Training Requirements Modeling to Inform Crew Size

Missions to Mars will differ from previous human spaceflight missions in that the onboard crew of astronauts will be required to operate in an Earth-independent manner due to the long communication delays. Without a systematic, repeatable process to determine the number and composition of crew necessary to successfully accomplish these missions, NASA increases the risk that crew sizes may be too small to meet primary mission objectives under nominal conditions and, more consequentially, that crewmembers may not have the expertise needed to successfully respond to unforeseen failures without the real-time expertise of the Mission Control Central (MCC) team NASA currently relies upon. The NASA Engineering and Safety Center (NESC) is developing a methodology for assessing the trade space of factors that affect the number of crew for future missions. This methodology includes the consideration of results from three human performance models developed using the Improved Performance Research and Integration Tool (IMPRINT) modeling platform as well as a custom-built model on expertise trained within the crew. The IMPRINT results will be presented in the modeling and simulation sub-tag. Here we present results of a model based on NASA’s crew qualification and responsibility matrix (CQRM), a tool used to identify the crew qualifications for each area of responsibility (operation, system, and payload) for a mission. The model outputs an optimized allocation of training assignments along with a flight-assigned CQRM that can be used to consider the expertise that can be trained within a crew of a given size. We discuss the CQRM model result implications on the trade space for Mars mission crew size.

Mars↗

Humans to Mars, but How Many? Using Training Requirements Modeling to Inform Crew Size

Missions to Mars will differ from previous human spaceflight missions in that the onboard crew of astronauts will be required to operate in an Earth-independent manner due to the long communication delays. Without a systematic, repeatable process to determine the number and composition of crew necessary to successfully accomplish these missions, NASA increases the risk that crew sizes may be too small to meet primary mission objectives under nominal conditions and, more consequentially, that crewmembers may not have the expertise needed to successfully respond to unforeseen failures without the real-time expertise of the Mission Control Central (MCC) team NASA currently relies upon. The NASA Engineering and Safety Center (NESC) is developing a methodology for assessing the trade space of factors that affect the number of crew for future missions. This methodology includes the consideration of results from three human performance models developed using the Improved Performance Research and Integration Tool (IMPRINT) modeling platform as well as a custom-built model on expertise trained within the crew. The IMPRINT results will be presented in the modeling and simulation sub-tag. Here we present results of a model based on NASA’s crew qualification and responsibility matrix (CQRM), a tool used to identify the crew qualifications for each area of responsibility (operation, system, and payload) for a mission. The model outputs an optimized allocation of training assignments along with a flight-assigned CQRM that can be used to consider the expertise that can be trained within a crew of a given size. We discuss the CQRM model result implications on the trade space for Mars mission crew size.

Mars↗

Size-dependent Strain in Epitaxial (001)Gadolinium-doped Ceria Nanoislands

We report size-dependent strain in epitaxial gadolinium doped ceria nanoislands, which was determined by synchrotron x-ray diffraction. Reciprocal space sections of symmetric, (004) and asymmetric, (224) reflections are approximated by a model assuming size-dependent strain of the islands using real-space size distribution obtained by atomic force microscopy. We show that the islands smaller than 40 nm are subjected to a high level of lateral tensile strain and normal compression. The lateral to normal strain ratio determined from the reciprocal map analysis suggests that lateral tension is the primary stress generator, possibly due to oxygen vacancy ordering on the island-substrate interface.

36 MATERIALS SCIENCE↗

Size effects on thermo-mechanical performance of U-10Mo monolithic fuel plates

Monolithic fuel is a fuel form that is considered for the conversion of high performance research reactors. This plate-type fuel consists of a high density U-Mo fuel in monolithic form that is sandwiched between zirconium diffusion barriers, and encapsulated in an aluminum cladding. To date, large number of plates have been irradiated with satisfactory perforamce. The program is now moving into the qualification phase, a predecessor to the timely conversion of the target reactors. It must be shown that the fuel system meets the safety standards and performs well in reactor. The requirement to satisfactory irradiation performance under normal operating conditions is primarily demonstrated by a successful testing. Since each reactor employs distinct fuel plate geometries for various consideration with unique plate design features and attributes, a single “generic” plate geometry capturing all of the extremities is not achievable. Furthermore, testing all these geometric and irradiation parameters on a large size plate is not practical. Therefore, a smaller, “down-scaled” versions of fuel plates, are often employed for experimental purposes. This limitation consequently requires much more cautious performance evaluations, as thermal and mechanical response of a plate with certain geometry may not be representative for a plate with a different geometry. To investigate if plate size has any effects on irradiation performance, the plates with various geometric dimensions were parametrically evaluated. In particular, length and width of the plates were varied between the bounding values. Temperature, deformation, stress values were comparatively evaluated. The results have indicated that effects of geometric ratios and plate size variations in length and width directions are insignificant. However, wider plates could become more prone to a warping-type deformation, if there are nonlinearities.

42 ENGINEERING↗

Size effects on thermo-mechanical performance of U-10Mo monolithic fuel plates

Monolithic fuel is a fuel form that is considered for the conversion of high performance research reactors. This plate-type fuel consists of a high density U-Mo fuel in monolithic form that is sandwiched between zirconium diffusion barriers, and encapsulated in an aluminum cladding. To date, large number of plates have been irradiated with satisfactory perforamce. The program is now moving into the qualification phase, a predecessor to the timely conversion of the target reactors. It must be shown that the fuel system meets the safety standards and performs well in reactor. The requirement to satisfactory irradiation performance under normal operating conditions is primarily demonstrated by a successful testing. Since each reactor employs distinct fuel plate geometries for various consideration with unique plate design features and attributes, a single “generic” plate geometry capturing all of the extremities is not achievable. Furthermore, testing all these geometric and irradiation parameters on a large size plate is not practical. Therefore, a smaller, “down-scaled” versions of fuel plates, are often employed for experimental purposes. This limitation consequently requires much more cautious performance evaluations, as thermal and mechanical response of a plate with certain geometry may not be representative for a plate with a different geometry. To investigate if plate size has any effects on irradiation performance, the plates with various geometric dimensions were parametrically evaluated. In particular, length and width of the plates were varied between the bounding values. Temperature, deformation, stress values were comparatively evaluated. The results have indicated that effects of geometric ratios and plate size variations in length and width directions are insignificant. However, wider plates could become more prone to a warping-type deformation, if there are nonlinearities.

42 ENGINEERING↗

Particle Size Analysis and Distribution

Scanning Electron Microscope (SEM) is a instrument used for examining samples at magnifications from 32 X to 500,000 X (for our instrument). The SEM is attached with an electron gun and is directed onto the sample. The sample then produces an image where it is read on the monitor. The electron gun is positioned at the top because it needs to shoot at the sample that is being tested. The electrons are then shot in a downward motion traveling through several lenses, such as the condenser lens for a more precise reading. Once the samples have been read by the instrument, it will show a picture that has a certain number of particles. Particle size distribution have many uses that are essential to life habits (health) or even conventional use for example construction. Here are just a few examples of how particle size analysis and distribution are being used even today. This Standard Reference Material (SRM) is primarily intended for use in the calibration of equipment used to measure particle size distributions (PSD) in the 9 μm to 30 μm range. A unit of SRM 1984 consists of a single bottle containing approximately 14 g of tungsten carbide/cobalt powder. Certified values: The PSD values at five mass percentiles were measured by scanning electron microscopy (SEM) and laser light scattering (LLS). The NIST certified PSD values by SEM are listed. These certified values were determined by the measurement of over 10 000 individual particles from three bottles. Comparing the certified NIST SRM 1984 tungsten carbide/cobalt powder with our results are almost identical. This is great because more accurate work can be done and proves that our laboratory is able to reproduce NIST results. In conclusion, the scanning electron microscope is used to capture the sampled element and display it to be counted. Without the use of particle distribution, it would be a difficult time to get necessities such as medicine, asthma pumps, constructing materials, or as simple as ink. Overall, our study is an experimental comparison of the techniques we have in house, which are LLS and SEM (combined with the NIH ImageJ software) using the NIST SRM-1984 as a common, well characterized sample so that we have an idea of how the results from the techniques compare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prediction for Pressure Differential Across HEPA Filter Media Based on Media Characteristics and Particle Size Distribution

A new method for predicting the pressure drop across High Efficiency Particulate Air (HEPA) filter media is proposed based upon mass deposited onto the filter and known physical characteristics of the filter media. Detailed are the methods used in conjunction with current filter loading models to predict the pressure drop, as well as tests conducted to validate the methods. The benefit of a prediction model for practical use lies in the manufacturing and service life of nuclear grade HEPA filters. HEPA filters for use in nuclear facilities have a prescribed expiration date and a maximum allowable operating pressure drop. Therefore, the ability to predict the pressure drop across a filter and relate it to an expected length of service time can enable a reduction in wasted filters. This will allow for more informed decisions to be made based upon the dictated life cycle of the filters. Also, understanding and predicting how the pressure drop of HEPA filter media behaves as a function of physical characteristics and loaded mass can assist in future design and manufacturing of filter media. Currently, most existing pressure drop models are either computationally based or analytical methods relying on data gathered during tests. Neither are practical for prediction; the computational methods are difficult to implement, and the current analytical methods are more useful as tools for analysis. The current analytical model developed by Bergman et al. is based upon the pressure drop from each media fiber and modeling the deposited particles as newly formed fibers. Using Bergman's model and the media properties, air properties, and known aerosol particle size distribution, a pressure drop curve as a function of loaded mass can be created. This curve implies initial loading in the depth of the filter media with a transition to pure surface loading on the filter face, and a sensitivity to an evolving particle size distribution as mass continues to load onto the filter. To implement the predictive model, knowledge of the mean filter fiber diameter and porosity of the filter media is required. Traditionally, the mean fiber diameter is calculated as an effective diameter from prior media testing, however, in this study a Scanning Electron Microscope (SEM) technique is used to acquire this variable. Validation of the predictive model is provided by flat sheet media tests under a controlled environment with a measured particle size distribution of the challenge aerosol and shows reasonable preliminary agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Observation of Weak Counterion Size Dependence of Thermoelectric Transport in Ion Exchange Doped Conducting Polymers Across a Wide Range of Conductivities

Conducting polymers are of interest for a broad range of applications from bioelectronics to thermoelectrics. The factors that govern their complex charge transport physics include the structural disorder present in these highly doped polymer films and the Coulombic interactions between the electronic charge carriers and the dopant counterions. Previous studies have shown that at low doping levels carriers are strongly trapped in the vicinity of the counterions, while at high doping levels charge transport is not limited by Coulombic trapping, which manifests itself in the conductivity being independent of the size of the dopant counterion. Here a recently developed ion exchange doping method is used to investigate the ion size dependence of a semicrystalline polythiophene–based model system across a wide range of conductivities. It is found that the regime in which the charge and thermoelectric transport is not or only weakly dependent on ion size, extends to surprisingly low conductivities. This surprising observation is explained by a heterogeneous doping that involves doping of the amorphous domains to high doping levels first before doping of the ordered, crystalline domains occurs. The study provides new insights into how the thermoelectric physics of conducting polymers evolves as a function of doping level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method to estimate uncertainty associated with parcel size in coarse discrete particle simulation

Coarse grained particle methods significantly reduce the computation cost of large‐scale fluidized bed simulation by lumping many real particles into a computation parcel. This research provides a method to estimate the errors associated with parcel size in large‐scale fluidized bed simulations. This uncertainty is first quantified in small scale domains by comparing results of discrete particle method with that employing coarse parcels of different sizes. Then, this uncertainty is correlated with parcel size and simulation domains consisting of a simple homogeneous cooling system and more complex bubbling and circulating fluidized beds. These correlations allow us to accurately estimate the uncertainty in large‐scale fluidized beds based solely on data obtained in smaller systems. The ability to estimate model‐related uncertainty in larger systems makes this method relevant for industrial applications. © 2018 American Institute of Chemical Engineers AIChE J , 64: 2340–2350, 2018

Lu, Liqiang↗

Luminescent Gold Nanoparticles with Size-Independent Emission

Size-independent emission has been widely observed for ultrasmall thiolated gold nanoparticles (AuNPs) but our understanding of the photoluminescence mechanisms of noble metals on the nanoscale has remained limited. In this paper, we report how the emission wavelength of a AuNP and the local binding geometry of a thiolate ligand (glutathione) on the AuNP are correlated, as these AuNPs emit at different wavelengths in spite of their identical size (ca. 2.5 nm). By using circular dichroism, X-ray absorption, and fluorescence spectroscopy, we found that a high Au–S coordination number (CN) and a high surface coverage resulted in strong Au I –ligand charge transfer, a chiral conformation, and 600 nm emission, whereas a low Au–S CN and a low surface coverage led to weak charge transfer, an achiral conformation, and 810 nm emission. These two size-independent emissions can be integrated into one single 2.5 nm AuNP by fine-tuning of the surface coverage; a ratiometric pH response was then observed owing to strong energy transfer between two emission centers, opening up new possibilities for the design of ultrasmall ratiometric pH nanoindicators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Evolution on Electrode–Supported Ptn Clusters: Ensemble of Hydride States Governs the Size Dependent Reactivity

We report the size-dependent activity and stability of supported Pt1,4,7,8 for electrocatalytic hydrogen evolution reaction, and show that clusters outperform polycrystalline Pt in activity, with sizedependent stability. To understand the size effects, we use DFT calculations to study the structural fluxionality under varying potentials. We show that the clusters can reshape under H coverage and populate an ensemble of states with diverse stoichiometry, structure, and thus reactivity. Both experiment and theory suggest that electrocatalytic species are hydridic states of the clusters (~2 H/Pt). An ensemble-based kinetic model reproduces the experimental activity trend and reveals the role of metastable states. Furthermore, the stability trend is rationalized by chemical bonding analysis. Our joint study demonstrates the potential- and adsorbate-coverage-dependent fluxionality of subnano clusters of different sizes and offers a systematic modeling strategy to tackle the complexities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neurosensory and Sinus Evolution as Tyrannosauroid Dinosaurs Developed Giant Size: Insight from the Endocranial Anatomy of Bistahieversor sealeyi

Tyrannosaurus rex and other tyrannosaurid dinosaurs were apex predators during the latest Cretaceous, which combined giant size and advanced neurosensory systems. Computed tomography (CT) data have shown that tyrannosaurids had a trademark system of a large brain, large olfactory bulbs, elongate cochlear ducts, and expansive endocranial sinuses surrounding the brain and sense organs. Older, smaller tyrannosauroid relatives of tyrannosaurids developed some, but not all, of these features, raising the hypothesis that tyrannosaurid-style brains evolved before the enlarged tyrannosaurid-style sinuses, which might have developed only with large body size. This has been difficult to test, however, because little is known about the brains and sinuses of the first large-bodied tyrannosauroids, which evolved prior to Tyrannosauridae. Here we present the first CT data for one of these species, Bistahieversor sealeyi from New Mexico. Bistahieversor had a nearly identical brain and sinus system as tyrannosaurids like Tyrannosaurus, including a large brain, large olfactory bulbs, reduced cerebral hemispheres, and optic lobes, a small tab-like flocculus, long and straight cochlear ducts, and voluminous sinuses that include a supraocciptal recess, subcondyar sinus, and an anterior tympanic recess that exits the braincase via a prootic fossa. When characters are plotted onto tyrannosauroid phylogeny, there is a two-stage sequence in which features of the tyrannosaurid-style brain evolved first (in smaller, nontyrannosaurid species like Timurlengia), followed by features of the tyrannosaurid-style sinuses (in the first large-bodied nontyrannosaurid tyrannosauroids like Bistahieversor). This suggests that the signature tyrannosaurid sinus system evolved in concert with large size, whereas the brain did not.

59 BASIC BIOLOGICAL SCIENCES↗

High-moisture pelleting of corn stover using pilot- and commercial-scale systems: Impact of moisture content, L / D ratio and hammer mill screen size on pellet quality and energy consumption

Here, high-moisture pelleting of corn stover was tested in pilot- and commercial-scale systems. For the pilot-scale study, a 6.35 mm screen size hammer mill ground corn stover was reconditioned to moisture between 14 and 29.6% (w.b.), and 5, 7 and 9 L/D ratio pellet die were used. At 29% corn stover moisture content and L/D ratios of 5 and 9, the bulk density and durability of the pellets were ≤450 kg/m 3 and <90% and >540 kg/m 3 and >90%, respectively. Increasing the feedstock moisture and L/D ratio increased the pelleting energy. Increasing the hammer mill screen size to 11.11 mm reduced the bulk density but not the durability. The response surface models adequately described the pelleting process (R 2 ≥ 0.88), and analysis of variance showed a strong interaction between the process variables and pellet properties. Commercial-scale testing of high-moisture pelleting using 6.35 mm ground corn stover bales in the moisture range 24–26% (w.b.) produced pellets with a density of >675 kg/m 3 and durability of >98%, whereas increasing the hammer mill screen size to 11.11 mm reduced the bulk density by about 100 kg/m 3 but not the durability. The energy consumption of the commercial-scale unit operations for the high-moisture pelleting process was in the range 98–124 kW h/ton, which is 64–72% less energy than conventional pelleting that requires energy about 350 kW h/ton for biomass drying from 30% (w.b.) to 10% (w.b.) moisture content before pelleting. Pellets produced using high-moisture pelleting met International Organization for Standardization and Pellets Fuel Institute international standards. Published 2023. This article is a U.S. Government work and is in the public domain in the USA.

09 BIOMASS FUELS↗

Electrochemical and Optical Spectroscopic Probing of Transition–Sized Au 130 (SR) 50 Nanoclusters

Ultrasmall metal nanoclusters (NCs) exhibit a quantized conduction band, hence, a distinct HOMO-LUMO gap (E g ). Such a quantized electronic structure gives rise to multiple discrete peaks in the optical absorption spectrum of the NCs. As the size grows to 130 gold atoms (Au 130 protected by ligands), electrical charging and optical behaviors seem to show certain metal-like features (hence, transition-sizes). To probe such behaviors, especially the potential ligand effect, we have devised the synthesis of Au 130 NCs protected by phenylethanethiolate and naphthalenethiolate, respectively, with the former having a nonconjugated separation between the aromatic molecular group and the metal core while the latter being in direct bonding. A careful comparison of these two Au 130 nanoclusters with the earlier reported analogues is carried out, including the structurally characterized Au 130 (pMBT) 50 and the aqueous counterpart. While all of these nanoclusters possess the same 80 free electron counts in the core, some notable differences in electrochemical and optical properties are found, which are attributed to the ligand effects. The obtained insights may stimulate further interest in the transition-sized nanoclusters and also promote their applications in optics, energy conversion, and biomedicine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Competing Grain Boundary and Interior Deformation Mechanisms with Varying Sizes

In typical coarse-grained alloys, the dominant plastic deformations are dislocation gliding or climbing, and material strengths can be tuned by dislocation interactions with grain boundaries, precipitates, solid solutions, and other defects. With the reduction of grain size, the increase of material strengths follows the classic Hall-Petch relationship up to nano-grained materials. Even at room temperatures, nano-grained materials exhibit strength softening, or called the inverse Hall-Petch effect, as grain boundary processes take over as the dominant deformation mechanisms. On the other hand, at elevated temperatures, grain boundary processes compete with grain interior deformation mechanisms over a wide range of the applied stress and grain sizes. This book chapter reviews and compares the rate equation model and the microstructure-based finite element simulations. The latter explicitly accounts for the grain boundary sliding, grain boundary diffusion and migration, as well as the grain interior dislocation creep. Therefore the explicit finite element method has clear advantages in problems where microstructural heterogeneities play a critical role, such as in the gradient microstructure in shot peening or weldment. Furthermore, combined with the Hall-Petch effect and its breakdown, the above competing processes help construct deformation mechanism maps by extending from the classic Frost-Ashby type to the ones with the dependence of grain size.

Zhang, Wei↗

Effects of finite material size on axion-magnon conversion

Magnetic materials are particularly favorable targets for detecting axions interacting with electrons because the collective excitation of electron spins, the magnon, can be excited through the axion-magnon conversion process. It is often assumed that only the zero-momentum uniformly precessing magnetostatic (Kittel) mode of the magnon is excited. This is justified if the de Broglie wavelength of the axion is much longer than the size of the target magnetic material. However, if the de Broglie wavelength is shorter, finite-momentum magnon modes can also be excited. We systematically analyze the target material size dependence of the axion-magnon conversion rate. We discuss the importance of these effects in the detection of relativistic axions as well as in the detection of axion dark matter of relatively heavy mass with large material size.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of tumor size and location on efficacy and safety of US- and CT- guided percutaneous microwave ablation in renal cell carcinomas

Purpose: To evaluate the effect of size and central location of the tumor on safety and efficacy of percutaneous CEUS- and CT-guided MWA in biopsy-proven renal cell carcinomas (RCCs). Materials and methods: In this IRB-approved retrospective study, 69 biopsy-proven renal tumors in 56 patients, who underwent MWA in our institution from January 2013 to March 2017, were evaluated. Data collection included demographics, tumor characteristics, procedural protocols, and follow-up visits within 6 months post procedure. Primary outcomes were assessed by technical success (TS), local tumor progression (LTP), and complications. The Kaplan–Meier analysis was used for survival rate. Results: Overall technical success was achieved for all 69 lesions (92.8% primary TS, 100% overall). Median nephrometry score was 8 (4–11) and median tumor size was 2.5 cm (0.8–7). Five lesions which required second ablation had significantly higher median tumor size 4 cm (P = 0.039) with the same nephrometry score. Renal function remained stable with no significant change in eGFR before or after ablation. The LTP rate was 5.8%. The most recurrent tumors were clear cell (50%) followed by papillary tumors (25%). The complication rate was 5.8% with minor complications (hematoma and pain) and no major issues. There was no significant association between nephrometry score and technical success, recurrence, or complication rates. Overall and tumor-specific survival rates were 96.7% and 100% at 11.9 months. Conclusions: Image-guided MWA appears to be a safe and effective treatment regardless of nephrometry score and tumor location with high technical success, low recurrence, and complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗