Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum electron devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Copper–Carbon Nanotube Composites Enabled by Electrospinning for Advanced Conductors

The power losses associated with the electrical resistance of copper (Cu) have generated considerable interest in the development of advanced conductors that incorporate carbon nanotubes (CNTs) into the Cu matrix—ultraconductive Cu (UCC) composites—to increase energy efficiency in various industrial and residential applications, ranging from electric power transmission and rotating machinery to electronic devices. To meet this demand, we describe an electrospinning-based polymer nanofiber templating strategy for the fabrication of UCC composites with electrical and mechanical performance exceeding that of Cu. Our approach involves electrospinning of polyvinylpyrrolidone (PVP)-based solutions containing CNTs into aligned PVP/CNT nanofibers onto Cu foil substrates, followed by vacuum-assisted thermal removal of organic solvent/polymer from the CNT matrix to achieve a uniformly distributed CNT layer on the Cu surface. Following additional Cu deposition, the Cu–CNT–Cu composites demonstrated similar electrical conductivity, higher current carrying capacity, and improved mechanical properties compared with those obtained from reference Cu. Importantly, after the heat treatment, Raman analysis of the CNT network displayed an increased metallic character that supports the enhanced electrical properties of the UCC composites. Thus, we believe that these performance characteristics together with the commercial viability of the present approach could open new possibilities in designing advanced conductors for a broad range of electrical systems and industrial applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulse Length Monitor for Breakdown Diagnostics in THz and Mm-Wave Accelerators

The development of novel high-gradient accelerating structures operating at THz frequencies is critical for future free-electron lasers and TeV scale linear colliders. To reach high energies with reasonable length requires high accelerating gradients of ~100 MV/m. The main limitation to reaching these high-energy gradients is the vacuum RF breakdown phenomenon, which disrupts normal accelerator operations. For stable operations and to understand the breakdown microscopic dynamics, a new device capable of detecting the breakdown occurrences is required. In this paper, we provide the design of a pulse length monitor based on an analog to digital converter for fast signal digitization without the need to use high-speed digitizers to be used in a commercial mm-wave heterodyne spectrometer.

43 PARTICLE ACCELERATORS↗

Physical vapor deposition simulator by graphical processor unit ray casting

This paper presents fast, accurate software for modeling physical vapor deposition systems over irregular surfaces. The model is implemented using graphics processing unit (GPU) ray casting. Applied models are viewed as a cross section of the area of interest. Given evaporation rate, time, and angular profiles in a vacuum system, an iterative time-step approach for calculating deposition profiles is calculated in the GPU architecture following a ballistic modeling approach. Thin-film technologies for the electronics industry will require evaporations on complex surfaces. Depending on the nature of the surface, a uniform thin film across the topology is wanted for various device parameters. The ray casting method is tested against various profiles. The code is freely distributed on GitHub (see https://github.com/adam-r-thomas/PVDS).

Engineering↗

Monitoring of the MU radar antenna pattern by Satellite Ohzora (EXOS-C)

As the first attempt among MST (mesosphere stratosphere troposphere) type radars, the MU (middle and upper atmosphere) radar features an active phased array system. Unlike the conventional large VHF radars, in which output power of a large vacuum tube is distributed to individual antenna elements, each of 475 solid state power amplifier feeds each antenna element. This system configuration enables very fast beam steering as well as various flexible operations by dividing the antenna into independent subarrays, because phase shift and signal division/combination are performed at a low signal level using electronic devices under control of a computer network. The antenna beam can be switched within 10 microsec to any direction within the zenith angle of 30 deg. Since a precise phase alignment of each element is crucial to realize the excellent performance of this system, careful calibration of the output phase of each power amplifier and antenna element was carried out. Among various aircraft which may be used for this purpose artificial satellites have an advantage of being able to make a long term monitoring with the same system. An antenna pattern monitoring system for the MU radar was developed using the scientific satellite OHZORA (EXOS-C). A receiver named MUM (MU radar antenna Monitor) on board the satellite measures a CW signal of 100 to 400 watts transmitted from the MU radar. The principle of the measurement and results are discussed.

Sato, T.↗

Carbon Nanotube Vacuum Gauges Utilizing Long, Dissipative Tubes

CNT Vacuum Gauges: a) have a broad range of pressure response from 760 - 10(exp -6) Torr. b) have current changes approx. 100's nA in high vacuum regime (10(exp -6) Torr) and sensitivity increases with power and substrate removal. c) have a negative dR/dT (TCR negative) where a thermal hopping energy E(sub a) was determined to be approx. 40 meV. d) have compatible fabrication requirements for their integration with micromachined structures. e) can be operated at low power (nW - micro-W). f) have an active device region footprint of < 10 sq microns. g) are non-intrusive due to small size and passive operation.

nanotube sensors↗

MHD-induced beta limits in the Large Helical Device

Using the extended-magnetohydrodynamics code, M3D-C1, we perform a systematic numerical study of the effect of externally applied heating on the achievable plasma beta in a ten field-period heliotron. Heat sources of varying intensity are applied to a vacuum magnetic field that is representative of the standard configuration of the Large Helical Device, with R 0 = 3.66 m, where R 0 is the radial position of the magnetic axis in vacuum. As the system is driven to a state that is unstable to low-n magnetohydrodynamic (MHD) modes, nonlinear mode interactions lead to the formation of chaotic magnetic fields. With sufficiently strong heating, a collapse of the electron temperature profile is observed. This demonstrates the necessity of simulating the self-consistent evolution of plasma profiles, without imposing assumptions on the structure of the magnetic field, to accurately determine transport properties in stellarator plasmas. It also highlights the value of these advanced simulation capabilities for accelerating the development of high-performance stellarator operating scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

(abstract) A Miniature, High-Sensitivity, Electron-Tunneling Accelerometer

A prototype low-noise accelerometer has been fabricated with an electron-tunneling transducer. By measuring the tunneling current between an electrode on the proof mass and a feedback-controlled monitor electrode, very small accelerations can be detected with high responsivity. This particular prototype (10x10x1.5 mm) was designed for underwater acoustic measurement from a few hertz to 1 kHz. The measured responsivity below the fundamental device resonance at 100 Hz is roughly 1500 volts per m/s(sup 2) with a measured noise spectral density of 10(sup -6) m/s(sup 2) per root hertz or less between 30 and 300 Hz. The noise floor is controlled primarily by 1/f noise in the tunneling current although the noise floor reaches the theoretical molecular-agitation limit at 100 hertz. The responsivity and directivity of the device were measured in a standard gradient-hydrophone calibrator; the noise floor was determined in a vacuum-ionization chamber assembled from commercial off-the-shelf components; and the detailed dynamics of the proof-mass motion were examined using a heterodyne laser interferometer that was scanned across the surface and synchronously detected with respect to the excitation.

accelerometer electron tunneling acoustic measurem↗

Kinetic equilibrium reconstructions of plasmas in the MAST database and preparation for reconstruction of the first plasmas in MAST upgrade

Reconstructions of plasma equilibria using magnetic sensors were routine during operation of the Mega Ampere Spherical Tokamak (MAST) device, but reconstructions using kinetic profiles were not. These are necessary for stability and disruption analysis of the MAST database, as well as for operation in the upgrade to the device, MAST-U. The three-dimensional (3D) code VALEN is used to determine eddy currents in the 3D vessel structures for vacuum coil test shots, which are then mapped to effective resistances in the two-dimensional vessel groupings in the EFIT equilibrium reconstruction code to be used in conjunction with nearby loop voltage measurements for estimated currents in the structures during reconstruction. Kinetic equilibrium reconstructions with EFIT, using all available magnetic sensors as well as Thomson scattering measurements of electron temperature and density, charge exchange recombination spectroscopy measurements of ion temperature, and internal magnetic field pitch angle measurements from a motional Stark effect (MSE) diagnostic are performed for a large database of MAST discharges. Excellent convergence errors are obtained for the portions of the discharges where the stored energy was not too low, and it is found that reconstructions performed with temperature and density measurements but without MSE data usually already match the pitch angle measurements well. A database of 275 kinetic equilibria is used to test the ideal MHD stability calculation capability for MAST. In conclusion, the necessary changes to conducting structure in VALEN, and diagnostic setup in EFIT have been completed for the upgrade from MAST to MAST-U, enabling kinetic reconstructions to commence from the first plasma discharges of the upgraded device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cleaning Carbon Nanotubes by Use of Mild Oxygen Plasmas

Experiments have shown that it is feasible to use oxygen radicals (specifically, monatomic oxygen) from mild oxygen plasmas to remove organic contaminants and chemical fabrication residues from the surfaces of carbon nanotubes (CNTs) and metal/CNT interfaces. A capability for such cleaning is essential to the manufacture of reproducible CNT-based electronic devices. The use of oxygen radicals to clean surfaces of other materials is fairly well established. However, previously, cleaning of CNTs and of graphite by use of oxygen plasmas had not been attempted because both of these forms of carbon were known to be vulnerable to destruction by oxygen plasmas. The key to success of the present technique is, apparently, to ensure that the plasma is mild . that is to say, that the kinetic and internal energies of the oxygen radicals in the plasma are as low as possible. The plasma oxygen-radical source used in the experiments was a commercial one marketed for use in removing hydrocarbons and other organic contaminants from vacuum systems and from electron microscopes and other objects placed inside vacuum systems. In use, the source is installed in a vacuum system and air is leaked into the system at such a rate as to maintain a background pressure of .0.56 torr (.75 Pa). In the source, oxygen from the air is decomposed into monatomic oxygen by radio-frequency excitation of a resonance of the O2 molecule (N2 is not affected). Hence, what is produced is a mild (non-energetic) oxygen plasma. The oxygen radicals are transported along with the air molecules in the flow created by the vacuum pump. In the experiments, exposure to the oxygen plasma in this system was shown to remove organic contaminants and chemical fabrication residues from several specimens. Many high-magnification scanning electron microscope (SEM) images of CNTs were taken before and after exposure to the oxygen plasma. As in the example shown in the figure, none of these images showed evidence of degradation of CNT structures.

Petkov, Mihail↗

Direct Visualization and Manipulation of Tunable Quantum Well State in Semiconducting Nb 2 SiTe 4

We report quantum well states (QWSs) can form at the surface or interfaces of materials with confinement potential. They have broad applications in electronic and optical devices such as high mobility electron transistor, photodetector, and quantum well laser. The properties of the QWSs are usually the key factors for the performance of the devices. However, direct visualization and manipulation of such states are, in general, challenging. In this work, by using angle-resolved photoemission spectroscopy (ARPES) and scanning tunneling microscopy/spectroscopy (STM/STS), we directly probe the QWSs generated on the vacuum interface of a narrow band gap semiconductor Nb 2 SiTe 4 . Interestingly, the position and splitting of QWSs could be easily manipulated via potassium (K) dosage onto the sample surface. Our results suggest Nb 2 SiTe 4 to be an intriguing semiconductor system to study and engineer the QWSs, which has great potential in device applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Localizing individual exciton on a quantum Hall antidot

Excitons are bond states of electron-hole pairs formed through Coulomb interaction. While excitonic phases have been widely studied in semiconductors and quantum Hall double-layers, prior works largely focus on bulk systems with large number of excitons, limiting their applications in quantum devices. Here, employing the approach of quantum Hall antidot with two spatially separated edge channels, we demonstrate a type of quantum Hall quasiparticle exciton which represents a quantum-coherent bound state of an electron and a hole situated on their corresponding edges coupled through intralayer tunneling and Coulomb interaction. This approach allows localization and electrical tuning of individual quantum Hall excitons. Quantum-coherent dynamics of exciton are observed in the gate-dependence of antidot conductance peaks near the electron-hole resonance, which signifies a quantum superposition of vacuum- and electron-hole pairing states. Modeling the electron-hole pair as a coupled two-level system, semi-quantitative understanding of experimental observations is achieved. This work opens avenues for creating quantum systems of multiple quantum Hall quasiparticles.

36 MATERIALS SCIENCE↗

Limiting current in a collisional crossed-field gap

Crossed-field devices are often used in pulsed power and high-power microwave applications. Previous studies derived closed-form solutions for the limiting current of a vacuum crossed-field system, corresponding to the maximum permissible current for laminar flow, below and above the Hull cutoff B H for magnetic insulation. We extend these studies by introducing collision frequency into the electron force law as a friction term to derive the limiting current in a collisional crossed-field gap. The resulting solution recovers the vacuum crossed-field case in the limit of no collisions and the collisional space-charge limited current with general initial velocity for magnetic field B → 0. In the limit of infinite collisions, we obtain a crossed-field equivalent to the Mott–Gurney law for the maximum current permissible in a collisional, nonmagnetic diode. When the collision frequency ν is less than the electron cyclotron frequency Ω, increasing initial velocity makes the critical current nonmonotonic with increasing ν with the critical current higher at B = B H for ν = Ω. As for a misaligned crossed-field gap where a component of the magnetic field was introduced parallel to the electric field across the gap, magnetic insulation is eliminated and the discontinuity at B = B H for limiting current observed in a vacuum crossed-field gap vanishes. As B → ∞, the limiting current approaches a constant that depends on the initial velocity and the collision frequency.

Breen, Lorin I.↗

Highly Efficient Multilayer Thermoelectric Devices

Multilayer thermoelectric devices now at the prototype stage of development exhibit a combination of desirable characteristics, including high figures of merit and high performance/cost ratios. These devices are capable of producing temperature differences of the order of 50 K in operation at or near room temperature. A solvent-free batch process for mass production of these state-of-the-art thermoelectric devices has also been developed. Like prior thermoelectric devices, the present ones have commercial potential mainly by virtue of their utility as means of controlled cooling (and/or, in some cases, heating) of sensors, integrated circuits, and temperature-critical components of scientific instruments. The advantages of thermoelectric devices for such uses include no need for circulating working fluids through or within the devices, generation of little if any noise, and high reliability. The disadvantages of prior thermoelectric devices include high power consumption and relatively low coefficients of performance. The present development program was undertaken in the hope of reducing the magnitudes of the aforementioned disadvantages and, especially, obtaining higher figures of merit for operation at and near room temperature. Accomplishments of the program thus far include development of an algorithm to estimate the heat extracted by, and the maximum temperature drop produced by, a thermoelectric device; solution of the problem of exchange of heat between a thermoelectric cooler and a water-cooled copper block; retrofitting of a vacuum chamber for depositing materials by sputtering; design of masks; and fabrication of multilayer thermoelectric devices of two different designs, denoted I and II. For both the I and II designs, the thicknesses of layers are of the order of nanometers. In devices of design I, nonconsecutive semiconductor layers are electrically connected in series. Devices of design II contain superlattices comprising alternating electron-acceptor (p)-doped and electron-donor (n)-doped, nanometer- thick semiconductor layers.

Boufelfel, Ali↗

Vacuum-Free, All-Solution, and All-Air Processed Organic Photovoltaics with over 11% Efficiency and Promoted Stability Using Layer-by-Layer Codoped Polymeric Electrodes

Nonfullerene organic photovoltaics (OPVs) have achieved a breakthrough in pushing the efficiency beyond 15%. Although this sheds light on OPV commercialization, the high cost associated with the scalable device fabrications remains a giant challenge. Herein, a vacuum-free, all-solution and all-air processed OPV is reported that yields 11.12% efficiency with a fill factor of 0.725, due to the usages of high-merit polymeric electrodes and modified active blends. The design principle toward the high-merit electrodes is to induce heavy acid doping into the matrices for a raised carrier concentration and mobility, make a large removal of insulating components in the whole matrices rather than surfaces, and restrain the formation of large-domain aggregates. A unique layer-by-layer doping is developed to enable the polymeric electrodes with record-high trade-offs between optical transmittance and electrical conductivity. Moreover, solvent vapor annealing is proposed to boost device efficiency and it has the advantages of finely adjusting the active blend morphology and raising the electron mobility. The resulting devices are highly efficient and most (≈91%) of the initial efficiency are maintained in 30 day storage. Finally, this work indicates bright future for making cost-effective all-solution processed OPVs in air.

14 SOLAR ENERGY↗

Cryogenic probe station for use in automated microwave and noise figure measurements

A cryogenic measurement system capable of performing on-wafer RF testing of semiconductor devices and circuits has been developed. This 'CryoProbe Station' can wafer-probe devices and circuits at cryogenic temperatures, thus eliminating the need for wire bonds. The system operates under vacuum created by a sorption pump. It uses an open cycle cooling system that can be cooled with either liquid nitrogen or liquid helium. Presently, it can reach temperatures, as low as 80 K and 37 K for each of the coolants, respectively. The temperature can be raised using a heater and it is stabilized to within 0.2 K by use of a temperature controller. The CryoProbe Station features a 1 by 2 inch stage that can hold large circuits and calibration standards simultaneously. The system is used with a Hewlett Packard 8510C Automatic Network Analyzer (ANA) to obtain S-parameter data over the frequency range 0.045-26.5 GHz. S-parameter data on HEMT (high electron mobility transistors) devices has been obtained with this station. With the use of DEEMBED software from NIST, detailed transmission line studies have been performed. Although the CryoProbe Station is designed for frequencies up to 26.5 GHz, useful transmission line data has been obtained for frequencies as high as 40 GHz. The CryoProbe station has also been used with the ATN noise figure measurement system to perform automatic, temperature dependent noise figure measurements.

Taub, Susan R.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

Surface Reactivity of Ag-Modified Ceria to Hydrogen: A Combined Experimental and Theoretical Investigation

We investigate the mechanism of H 2 activation on Ag-modified cerium oxide surfaces, of interest for different catalytic applications. The study is performed on thin epitaxial cerium oxide films, investigated by X-ray photoemission spectroscopy to assess the changes of both the Ag oxidation state and the concentration of Ce 3+ ions, O vacancies, and hydroxyl groups on the surface during thermal reduction cycles in vacuum and under hydrogen exposure. The results are interpreted using density functional theory calculations to model pristine and Ag-modified ceria surfaces. Although the reactivity of ceria toward H 2 oxidation improves when a fraction of Ce cations is substituted with Ag, the concentration of reduced Ce 3+ ions in Ag-modified ceria is found to be lower than in pure ceria under the same conditions. This behavior is observed even though the number of surface oxygen vacancies caused by the thermal treatment under hydrogen exposure is larger for the Ag-modified surface. These results are explained in terms of a change of the oxidation state of the surface Ag, which is able to acquire some of the extra surface electrons created by the oxygen vacancies and the adsorbed hydrogen atoms. Our findings provide new insights into the reactivity of Ag-modified ceria, which has been proposed as a promising alternative to platinum electrodes in electrochemical devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗