Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Evaluation of an in vitro three-dimensional HepaRG spheroid model for genotoxicity testing using the high-throughput CometChip platform

Three-dimensional (3D) culture systems are increasingly being used for genotoxicity studies due to improved cell-to-cell interactions and tissue-like structures that are limited or lacking in 2D cultures. The present study optimized a 3D culture system using metabolically competent HepaRG cells for in vitro genotoxicity testing. 3D HepaRG spheroids, formed in 96- or 384-well ultra-low attachment plates, were exposed to various concentrations of 34 test articles, including 8 direct-acting and 11 indirect-acting genotoxicants/carcinogens as well as 15 compounds that show different genotoxic responses in vitro and in vivo. DNA damage was evaluated using the high-throughput CometChip assay with concurrent cytotoxicity assessment by the ATP assay in both 2D and 3D cultures. 3D HepaRG spheroids maintained a stable phenotype for up to 30 days with higher levels of albumin secretion, cytochrome P450 gene expression, and enzyme activities compared to 2D cultures. 3D spheroids also demonstrated a higher sensitivity than 2D cultures for detecting both direct- and indirect-acting genotoxicants/carcinogens, indicating a better prediction of in vivo genotoxicity responses. When DNA damage dose-response data were quantified using PROAST software, 3D spheroids generally had lower or similar benchmark dose values compared to 2D HepaRG cells and were more comparable with primary human hepatocytes. These results demonstrate that 3D models can be adapted to the CometChip technology for high-throughput genotoxicity testing and that 3D HepaRG spheroids may be used as a reliable and pragmatic in vitro approach to better support the hazard identification and risk assessment of potential human genotoxic carcinogens.

60 APPLIED LIFE SCIENCES↗

Higher Throughput, Lower Cost Processing of Flexible Perovskite Solar Cells by Photonic Curing

The objectives of this SETO project are to explore whether photonic curing can be used to perform annealing in perovskite solar cell (PSC) fabrication, and if so, whether it can enable high-throughput PSC manufacturing. The successful outcome of the project will reduce manufacturing cost towards realizing the SETO goal of the Levelized cost of electricity (LCOE) $0.03/kWh by 2030. The project is a collaboration between Hsu’s group at the University of Texas at Dallas (UTD) and NovaCentrix, an Austin TX based company that pioneered the PulseForge® photonic curing tools and has expertise in applying this technology to printed electronics. Thin-film synthesis typically involves a thermal annealing step to convert from precursors to final material phases, to obtain the desired crystalline phase, or to improve materials structural or electrical properties. However, thermal annealing typically requires high temperatures that are incompatible with inexpensive plastic substrates and annealing times lasting tens-to-hundreds of minutes, making it incompatible with roll-to-roll (R2R) manufacturing at a desirable web speed. Photonic curing uses a flash Xe lamp to deliver short (20 µs to 100 ms) but high intensity (up to 50 kW/cm 2 ) pulses of broadband light (200 – 1500 nm) to the sample. It has been successfully applied to sinter printed metal nanoparticle inks into conductive patterns. This project aimed to extend the applications of photonic curing to convert halide perovskite films and transparent metal oxide transport layers. Despite the interruption by COVID-19, we have achieved significant accomplishments to establish photonic curing as a viable technology for the high-throughput manufacturing of PSCs. (1) We demonstrated that photonic curing can convert both metal oxide transport layer and halide perovskite absorber in the PSCs and successfully made flexible PSCs on Corning Willow glass® (WG)/ indium tin oxide (ITO) substrates without any thermal annealing steps. These photonically cured devices achieve performance comparable to conventional thermally annealed devices but were fabricated with a total processing time reduced by six orders of magnitude. We also show that photonic curing can achieve desirable web speed (up to 26 m/min) and large-area uniformity. (2) By establishing photonic curing processing phase spaces for the perovskite, we show that the longer pulses are more forgiving in small variation in the photonic curing conditions, making it more suitable for R2R manufacturing. (3) Our results clearly illustrated the importance of improving mechanical and optical properties of transparent electrodes on flexible substrates. (4) We also performed fundamental studies that elucidate the interactions between perovskite absorber and metal oxide transport layer that can undermine the PSC stability. Five refereed journal papers in top journals (ACS Energy Letters, npj Flexible Electronics, ACS Applied Energy Materials, Materials Advances, and Frontiers in Energy Research), one conference proceeding (PVSC-47), six conference presentations (PVSC and Materials Research Society meetings), and a Ph.D. dissertation (Trey B. Daunis) were produced under this project. Energy Materials Corporation (EMC) has forecast that with a 1.5 m wide web moving at a web speed of 30 m/min, R2R processing of PSC could provide up to 4 GW/year for a single R2R assembly line. Replacing thermal annealing with photonic curing, as demonstrated by the accomplishments of this project, is necessary to realize such an energy production goal.

14 SOLAR ENERGY↗

High Throughput In-Line Coating Metrology Development for Solid Oxide Fuel Cell Manufacturing

Coatings play key roles in solid oxide fuel cell (SOFC) stack durability. For example, diffusion barrier coatings on Cr-containing interconnect and balance of plant (BOP) components protect electrodes from Cr poisoning over the long operational lifetimes (>10,000 hours) of the fuel cell stack. Common defects in coatings, such as cracks, pinholes, and porosity, result in a failure to protect the electrodes, resulting in shorter operational lifetime and thus higher cost. It is very unlikely, even in the best coating process, that all these defects can be mitigated, hence identifying critical defects in parts, and removing defective parts from production before they can damage the stack, becomes paramount. Furthermore, these quality control techniques must be operational in the production/assembly line (in-line), i.e., high throughput and non-destructive, and cost effective. Redox Power Systems, LLC (Redox) together with the National Renewable Energy Laboratory (NREL) developed much needed high throughput, in-line metrology techniques for protective coatings. The overall goal of the project is to lower cost while increasing robustness, reliability, and endurance of SOFC stacks. To accomplish this, we had several objectives, including: to identify key coating and substrate defects that lead to coating failure through the use of detailed characterization methods (e.g., microscopy, XRD, EDS, electrochemistry); to assess capabilities of in-line metrology techniques, e.g., optical profilometry (Redox) and thermography (NREL), to probe these defects, or evidence thereof; demonstrate long-term performance of “defect-free” protective coatings, as identified by in-line metrology, in solid oxide fuel cell (SOFC) stack operation. In the first part of this project, the ability to identify key defects expected to lead to coating and SOFC degradation using in-line metrology tools were evaluated. Coated interconnect samples with controlled defect types and populations were tested under conditions similar to SOFC operation, followed by detailed post-test analysis to reveal the defects responsible for observed degradation. In the second part of the project, the optimal in-line metrology techniques and methodologies were used to map the defect distribution in full-size interconnects with critical defects intentionally allowed to exist in some cases. These interconnects underwent SOFC testing for extended periods (up to ~3,000 hours) followed by post-test analysis to evaluate the effectiveness of in-line metrology techniques in mitigating MCO coating related degradation. Key accomplishments in this project included the following: Demonstrated ASR of < 0.05 ohm-cm 2 at 650 °C for 1,000 hours with low defect (determined by in-line metrology) interconnect samples (average ASR=37 milliohms-cm 2 after over 1,000 hours). Demonstrated that low defect coatings on interconnects (as screened using in-line metrology) have low volatilization of chromium at ~650 °C for 1,000 hours as detected using Cr-getter material (< 5 at% increase above baseline); 1022 hour duration tests under humidified, elevated temperature (750 °C rather than 650 °C) compared a base case against different coating thicknesses. Demonstrated capability to identify initial key defects of interest with in-line metrology techniques using up to 8 cm by 10 cm having coatings with and without intentional defects of interest using thermal imaging and optical profilometry. Correlated key defects identified using metrology techniques with observed coating performance (e.g., ASR and Cr volatility). Conducted several 4 cm by 4 cm cell tests using MCO-interconnects that were pre-screened using some of the metrology techniques developed in the project (e.g., optical profilometry). An analysis of ASR measurements were able to show that defect-free coatings resulted in the anticipated performance in the cell tests.

01 COAL, LIGNITE, AND PEAT↗

High-throughput native mass spectrometry as experimental validation for in silico drug design

In this project, we developed automated workflows for both experimental validation and computational prediction of protein-ligand interactions. The ultimate goal is to establish an integrated pipeline for high throughput design of inhibitors to enzymes relevant to all areas of biological research. Our experimental approach is based on native mass spectrometry (native MS), which measures accurate masses and quantify the relative abundance of protein-ligand complexes to define binding affinity. We set up an in-house built autosampler with highly flexible configurations to minimize the manual steps for high throughput native MS. In parallel, we also performed manual native MS to characterize the binding of substrates and inhibitors of SARS-Cov-2 nonstructural protein nsp10/16 in order to optimize the experimental parameters for future automation. On the computational side, we streamlined the pipeline to achieve minimal manual intervention for predicting enzyme inhibitors via simulation, using the same nsp10/16 system as an example. Using the native MS method we examined 8 top-ranked designed compounds, 2 of which showed weak binding of ~50 µM. The information from native MS experiment provided critical insights and the foundation for a fully integrated workflow for enzyme inhibitor design.

59 BASIC BIOLOGICAL SCIENCES↗

A Platform Technology for High-throughput Atomically Precise Manufacturing: Mechatronics at the Atomic Scale

The main objective of this project is to invent the necessary enabling technologies for high throughput atomically precise manufacturing (APM). APM is an emerging technology that refers to any manufacturing capability that enables fabrication of atomically precise structures, components, and devices under programmable control. APM will require positional assembly at the atomic and/or molecular scale, as well as at the nano and microscales using hierarchical assembly to create products ranging from nanoscale and quantum devices to macroscale systems and materials. This project builds on the expectation that commercial viability of APM will depend on a high level of parallelism to achieve the required throughput, a capability that currently does not exist. This project is the first attempt to address this key technological bottleneck.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High Throughput Source-less Plasma Deposition of Structured Silicon Anodes for Lithium-Ion Batteries

Amprius developed a manufacturing solution for silicon nanowire anode that relies on an inexpensive, high throughput, and high gas precursor utilization plasma deposition method that uses the anode foils as electrodes for plasma generation. The capacitively couple plasma (CCP) method is used in semiconductor and photovoltaic industry and Amprius modified existing high throughput equipment to use anode foils and to deposit amorphous silicon. The equipment was installed ahead of the program at Amprius site. The rest of the tasks included foil handling and process development. The equipment passed site acceptance tests (SAT) and the process parameter mapping was completed, indicating that the target process window limits produce output materials at the rate and with yield and specifications that meet the manufacturing target criteria. Amprius has hired supporting personnel to optimize processes and run the equipment. A parallel task verified the baseline performance of the silicon anode material, to be used as reference for the new manufacturing method.

25 ENERGY STORAGE↗

High Throughput Genome Releaser

In this study, we present the development of a High Throughput Genome Releaser, an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed for rapid, cost-effective, and efficient DNA extraction, optimized for subsequent PCR reactions. Our experimentation with various synthetic materials led us to select a particular type of plastic that mirrors the properties of glass cover slides, providing a smooth surface and effective compression capabilities. We engineered a 96-well device equipped with a 96-well plate and a top rod, operable both manually and automatically, which is compatible with widely used liquid-handling robot decks. This compatibility enhances ease of use in high-throughput PCR setups. Additionally, we developed software to support its automatic functions. The genome releaser facilitates the extraction of PCR-amplifiable genomic DNA from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells. This versatility could significantly advance biomanufacturing processes.

42 ENGINEERING↗

Characterization of Performance Degradation Mechanisms in Low-Cost High Throughput DI-O3 Layer for Passivated Contact Silicon Solar Cells

Characterization and mitigating performance limiting defects in Silicon (Si) PV is one of key areas to be addressed to improve PV hardware costs and energy yield in order to lower the levelized cost of energy (LCOE) of installed PV cost to $0.02/kWh. As Si PV cells efficiencies have surpassed 22% and approaching 23%, the recombination at the metal contacts have become the focus point to be addressed. Passivated contact technologies—having a heterojunction with a band-gap larger than silicon between the metal and silicon—have emerged as a great potential for future highand ultrahigh-efficiency solar cells, as it concurrently reduces recombination and increases carrier selectivity, by incorporating thin films within the contact structure. Passivated contact Si solar cell technologies use a wide variety of tunnel layers—playing a crucial role to passivate metal contacts and tunnel charge carriers—including stoichiometric silicon oxide (SiO 2 ) grown by thermal oxidation and Low-Pressure Chemical Vapor Deposition (LPCVD) technique and silicon oxide (SiO x ) by hot nitric acid. However, thorough investigations on understanding the failure and performance degradation mechanisms associated with tunnel layers are still limited to date. Unlocking those degradation characteristics in crucial tunnel layers could improve the reliability and energy yield of passivated contact Si solar cells. Besides, the technique of growing aforementioned tunneling layers are low throughput, and requires high temperature processes and/or a vacuum environment. In this project, we investigated the performance degradation mechanisms of a low-cost high-throughput ozonated oxide (DI-O 3 ) tunnel layer for the passivated contact Si solar cells.

14 SOLAR ENERGY↗

Micro-Mechanically Guided High-Throughput Alloy Design Exploration Towards Metastability-Induced H Embrittlement Resistance

We develop a high-throughput approach for studying H embrittlement (HE)-resistance in alloys, which is based on combinatorial compositional screening of metastability effects by in situ scanning electron microscopy H-analyses. The project objective included: (i) technique development of high-throughput screening (HTS) for HE-resistance, (ii) discovery of new metallic materials with superior HE-resistance, (iii) Multiscale verification of HE-resistance of the new alloys and H-barrier layers, from atomic scale to an engineering scale. The investigation focused on a model system that enables exploration of different metastable states in Fe-based complex-concentrated alloys. Composition spread islands with hundreds of varying compositions are fabricated on a single substrate using a combinatorial co-sputtering technique. To screen these alloys, we developed and employed a home-built SEM-based integrated analysis system capable of characterizing H-permeability, H-trapping, H-influence on mechanical properties, and other material properties, as well as atomistic to continuum simulations to study the underlying physics.

08 HYDROGEN↗

High Throughput Solvent-free Manufacturing of Battery Electrodes

The project goal is to develop and demonstrate an advanced solvent-free lithium-ion battery electrode process through proposed Advanced Dry Electrode Process (ADEP) equipment, which is expected to exhibit a better binder fibrillization and high throughput and suitable for high performance electrode manufacturing, and commonize the anode and cathode dry processing equipment, supply chain and operation for lithium-ion battery OEMs for replacing the solvent-based slurry casting. Our proposed approach will facilitate low-cost battery production by addressing the following gaps in present dry electrode processing: • Extend the dry electrode fabrication process to lithium-ion battery anode manufacturing • Increase the active material content for anodes and cathodes • Intensify the process through improved mixing, powder rheology and surface modifications • Enable processing of next-generation electrode materials that are not stable to solvent or ambient air exposure. The project objectives include the development of anode-compatible binder and binder fibrillization promoter for low irreversible capacity loss, low electrode binder content yet higher film mechanical strength, and the optimization of solvent-free anode and cathode process for low cost (>60% electrode cost reduction), high performance (10% increase in energy density without sacrificing cycle life) and high throughput to enable next generation lithium-ion battery electrode production. Solvent-free electrode manufacturing will also enable next-generation cell designs based on prelithiated anodes or solid-state electrolytes.

25 ENERGY STORAGE↗

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION↗

To have value, comparisons of high-throughput phenotyping methods need statistical tests of bias and variance

The gap between genomics and phenomics is narrowing. The rate at which it is narrowing, however, is being slowed by improper statistical comparison of methods. Quantification using Pearson’s correlation coefficient ( r ) is commonly used to assess method quality, but it is an often misleading statistic for this purpose as it is unable to provide information about the relative quality of two methods. Using r can both erroneously discount methods that are inherently more precise and validate methods that are less accurate. These errors occur because of logical flaws inherent in the use of r when comparing methods, not as a problem of limited sample size or the unavoidable possibility of a type I error. A popular alternative to using r is to measure the limits of agreement (LOA). However both r and LOA fail to identify which instrument is more or less variable than the other and can lead to incorrect conclusions about method quality. An alternative approach, comparing variances of methods, requires repeated measurements of the same subject, but avoids incorrect conclusions. Variance comparison is arguably the most important component of method validation and, thus, when repeated measurements are possible, variance comparison provides considerable value to these studies. Statistical tests to compare variances presented here are well established, easy to interpret and ubiquitously available. The widespread use of r has potentially led to numerous incorrect conclusions about method quality, hampering development, and the approach described here would be useful to advance high throughput phenotyping methods but can also extend into any branch of science. The adoption of the statistical techniques outlined in this paper will help speed the adoption of new high throughput phenotyping techniques by indicating when one should reject a new method, outright replace an old method or conditionally use a new method.

59 BASIC BIOLOGICAL SCIENCES↗

Robust High-Throughput Phenotyping with Deep Segmentation Enabled by a Web-Based Annotator

The abilities of plant biologists and breeders to characterize the genetic basis of physiological traits are limited by their abilities to obtain quantitative data representing precise details of trait variation, and particularly to collect this data at a high-throughput scale with low cost. Although deep learning methods have demonstrated unprecedented potential to automate plant phenotyping, these methods commonly rely on large training sets that can be time-consuming to generate. Intelligent algorithms have therefore been proposed to enhance the productivity of these annotations and reduce human efforts. We propose a high-throughput phenotyping system which features a Graphical User Interface (GUI) and a novel interactive segmentation algorithm: Semantic-Guided Interactive Object Segmentation (SGIOS). By providing a user-friendly interface and intelligent assistance with annotation, this system offers potential to streamline and accelerate the generation of training sets, reducing the effort required by the user. Our evaluation shows that our proposed SGIOS model requires fewer user inputs compared to the state-of-art models for interactive segmentation. As a case study of the use of the GUI applied for genetic discovery in plants, we present an example of results from a preliminary genome-wide association study (GWAS) of in planta regeneration in Populus trichocarpa (poplar). We further demonstrate that the inclusion of a semantic prior map with SGIOS can accelerate the training process for future GWAS, using a sample of a dataset extracted from a poplar GWAS of in vitro regeneration. The capabilities of our phenotyping system surpass those of unassisted humans to rapidly and precisely phenotype our traits of interest. The scalability of this system enables large-scale phenomic screens that would otherwise be time-prohibitive, thereby providing increased power for GWAS, mutant screens, and other studies relying on large sample sizes to characterize the genetic basis of trait variation. Our user-friendly system can be used by researchers lacking a computational background, thus helping to democratize the use of deep segmentation as a tool for plant phenotyping.

54 ENVIRONMENTAL SCIENCES↗

High-Throughput Field Plant Phenotyping: A Self-Supervised Sequential CNN Method to Segment Overlapping Plants

High-throughput plant phenotyping—the use of imaging and remote sensing to record plant growth dynamics—is becoming more widely used. The first step in this process is typically plant segmentation, which requires a well-labeled training dataset to enable accurate segmentation of overlapping plants. However, preparing such training data is both time and labor intensive. To solve this problem, we propose a plant image processing pipeline using a self-supervised sequential convolutional neural network method for in-field phenotyping systems. This first step uses plant pixels from greenhouse images to segment nonoverlapping in-field plants in an early growth stage and then applies the segmentation results from those early-stage images as training data for the separation of plants at later growth stages. The proposed pipeline is efficient and self-supervising in the sense that no human-labeled data are needed. We then combine this approach with functional principal components analysis to reveal the relationship between the growth dynamics of plants and genotypes. We show that the proposed pipeline can accurately separate the pixels of foreground plants and estimate their heights when foreground and background plants overlap and can thus be used to efficiently assess the impact of treatments and genotypes on plant growth in a field environment by computer vision techniques. This approach should be useful for answering important scientific questions in the area of high-throughput phenotyping.

59 BASIC BIOLOGICAL SCIENCES↗

Measuring Fiber Positioning Accuracy and Throughput with Fiber Dithering for the Dark Energy Spectroscopic Instrument

Highly multiplexed, fiber-fed spectroscopy is enabling surveys of millions of stars and galaxies. The performance of these surveys depends on accurately positioning fibers in the focal plane to capture target light. We describe a technique to measure the positioning accuracy of fibers by dithering fibers slightly around their ideal locations. This approach also enables measurement of the total system throughput and point-spread function delivered to the focal plane. We then apply this technique to observations from the Dark Energy Survey Instrument (DESI), and demonstrate that DESI positions fibers to within 0farcs08 of their targets (5% of a fiber diameter) and achieves a system throughput within about 7% of expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PSTN-054: Updated estimates of the Rubin system throughput and expected LSST image depth

This document presents updated estimates, as of May 2022, of the Rubin system throughput and compares them to throughput requirements from the LSST Science Requirements Document. In addition, it uses these estimates to forecast LSST's median single-visit and co-added image depths for the current (OpSim v2.0) baseline LSST cadence simulation: (23.8, 24.5, 24.0, 23.4, 22.7, 22.0) and (25.6, 26.9, 26.9, 26.4, 25.6, 24.8) in ugrizy, respectively. In addition, it uses these estimates to forecast LSST’s median single-visit and co-added image depths for the current baseline LSST cadence simulation. Estimated system performance relies on actual measurements of the performance of various system hardware components, and on simulations where measurements are still unavailable. The updated performance estimates meet all the relevant requirements from the LSST Science Requirements Document. As our knowledge of the as-buit system continues to improve, updates to these estimates will continue to be provided.

79 ASTRONOMY AND ASTROPHYSICS↗

Diolkos: Improving ethernet throughput through dynamic port selection

In large networked systems, a sudden increase in traffic could slowdown the network significantly, impacting network quality for multiple users. We present Diolkos, a system that leverages smart switches to dynamically re-reroute data flows in response to drops in performance. In contrast to other techniques, our tool predicts the future throughput at each port in a switch if a data flow were to be sent through it, and updates which port should be taken to maximize throughput. We use several techniques to predict network switch performance on a software defined network (SDN) mimicking topologies commonly found in datacenters. Experimentally, we demonstrate the effectiveness of choosing a port to send flows through based on predicted performance. We found that using a distributed predictive technique achieves a 24% improvement over using a traditional heuristic technique.

port selection, performance enhancement, Neural Ne↗

Optimal Decision Making in High-Throughput Virtual Screening Pipelines

ABSTRACT Effective selection of the potential candidates that meet certain conditions in a tremendously large search space has been one of the major concerns in many real-world applications. In addition to the nearly infinitely large search space, rigorous evaluation of a sample based on the reliable experimental or computational platform is often prohibitively expensive, making the screening problem more challenging. In such a case, constructing a high-throughput screening (HTS) pipeline that pre-sifts the samples expected to be potential candidates through the efficient earlier stages, results in a significant amount of savings in resources. However, to the best of our knowledge, despite many successful applications, no one has studied optimal pipeline design or optimal pipeline operations. In this study, we propose two optimization frameworks, applying to most (if not all) screening campaigns involving experimental or/and computational evaluations, for optimally determining the screening thresholds of an HTS pipeline. We validate the proposed frameworks on both analytic and practical scenarios. In particular, we consider the optimal computational campaign for the long non-coding RNA (lncRNA) classification as a practical example. To accomplish this, we built the high-throughput virtual screening (HTVS) pipeline for classifying the lncRNA. The simulation results demonstrate that the proposed frameworks significantly reduce the effective selection cost per potential candidate and make the HTS pipelines less sensitive to their structural variations. In addition to the validation, we provide insights on constructing a better HTS pipeline based on the simulation results.

97 MATHEMATICS AND COMPUTING↗