Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The Miniaturized Moessbauer Spectrometer MIMOS II of the Athena Payload for the 2003 MER Missions

A first-order requirement of spacecraft missions that land on Mars is instrumentation for in situ mineralogical analysis. Moessbauer Spectroscopy is a powerful tool for quantitative analysis of Fe-bearing materials. The Athena Moessbauer spectrometer MIMOS II on the martian surface will provide: (1) identification of iron-bearing phases (e.g., oxides, silicates, sulfides, sulfates, and carbonates), (2) quantitative measurement of the distribution of iron among its oxidation states (e.g., Fe(2+)/Fe(3+) ratio), and (3) quantitative measurement of the distribution of iron among iron-bearing phases (e.g., the relative proportions of iron in olivine, pyroxene, and magnetite in a basalt) in rocks and soils. Moessbauer data will also be highly complementary with chemical analyses from the APXS and the Mini-TES compositional data. Mars is a particularly good place to do Moessbauer mineralogy because its surface is iron rich (approx. 20% Fe as Fe2O3). Moessbauer spectrometers that are built with backscatter measurement geometry require no sample preparation, a factor important for in situ planetary measurements.

G Klingelhoefer↗

Quantitative Hydrocarbon Surface Analysis

The elimination of ozone depleting substances, such as carbon tetrachloride, has resulted in the use of new analytical techniques for cleanliness verification and contamination sampling. The last remaining application at Rocketdyne which required a replacement technique was the quantitative analysis of hydrocarbons by infrared spectrometry. This application, which previously utilized carbon tetrachloride, was successfully modified using the SOC-400, a compact portable FTIR manufactured by Surface Optics Corporation. This instrument can quantitatively measure and identify hydrocarbons from solvent flush of hardware as well as directly analyze the surface of metallic components without the use of ozone depleting chemicals. Several sampling accessories are utilized to perform analysis for various applications.

Douglas, Vonnie M.↗

Analysis of T4 phage proteins. I

T4 phage proteins radioisotopical examination, determining quantitative analysis and molecular weight by autoradiography

Cone, R.↗

Measurement of taskload in the analysis of aircrew performance

The objective of the study was to perform a quantitative analysis of a high workload portion of a full mission flight simulation in order to test the hypothesis that taskload area is a valid, objective measure of workload management. This methodology provides a tool for the researcher attempting to quantify the management of workload in a complex environment. The researcher can then produce a reliable quantitative evaluation of behavior related to workload management.

Laudeman, Irene V.↗

Analysis of spectra using correlation functions

A novel method is presented for the quantitative analysis of spectra based on the properties of the cross correlation between a real spectrum and either a numerical synthesis or laboratory simulation. A new goodness-of-fit criterion called the heteromorphic coefficient H is proposed that has the property of being zero when a fit is achieved and varying smoothly through zero as the iteration proceeds, providing a powerful tool for automatic or near-automatic analysis. It is also shown that H can be rendered substantially noise-immune, permitting the analysis of very weak spectra well below the apparent noise level and, as a byproduct, providing Doppler shift and radial velocity information with excellent precision. The technique is in regular use in the Atmospheric Trace Molecule Spectroscopy (ATMOS) project and operates in an interactive, realtime computing environment with turn-around times of a few seconds or less.

Beer, Reinhard↗

Multispectral analysis of ocean dumped materials

Remotely sensed data were collected in conjunction with sea-truth measurements in three experiments in the New York Bight. Pollution features of primary interest were ocean dumped materials, such as sewage sludge and acid waste. Sewage-sludge and acid-waste plumes, including plumes from sewage sludge dumped by the 'line-dump' and 'spot-dump' methods, were located, identified, and mapped. Previously developed quantitative analysis techniques for determining quantitative distributions of materials in sewage sludge dumps were evaluated, along with multispectral analysis techniques developed to identify ocean dumped materials. Results of these experiments and the associated data analysis investigations are presented and discussed.

Johnson, R. W.↗

An analysis of morphologic variation in simple lunar craters

Previous photogeologic classification of lunar craters have differentiated them into various morphologic types. In an attempt to identify the physical factors responsible for these morphologic variations, this study examined 44 fresh, simple lunar craters between 1.1 and 14 km in diameter on the maria. Photogeologic analysis was performed using Apollo stereo panoramic photography, while a quantitative analysis of cross-sectional shape was done using Fourier analysis. These analyses showed that the sample could not be split into two distinct types (flat- and round-floored) as had been done previously. The two crater types at best represent end-members of a distribution of morphologies. Some correlation was found between the degree of relative degradation and floor roundness, implying that flat floors are primary and round floors are degradational features. No difference was found between the average depth-to-diameter ratio of flat- and round-floored craters, indicating that the factor of two variation in depth-to-diameter ratio in this sample of fresh craters is a primary morphologic feature and that minor degradation of fresh craters has no significant effect on average crater depth.

Ravine, M. A.↗

Three-dimensional segmentation of luminal and adventitial borders in serial intravascular ultrasound images

Intravascular ultrasound (IVUS) provides exact anatomy of arteries, allowing accurate quantitative analysis. Automated segmentation of IVUS images is a prerequisite for routine quantitative analyses. We present a new three-dimensional (3D) segmentation technique, called active surface segmentation, which detects luminal and adventitial borders in IVUS pullback examinations of coronary arteries. The technique was validated against expert tracings by computing correlation coefficients (range 0.83-0.97) and William's index values (range 0.37-0.66). The technique was statistically accurate, robust to image artifacts, and capable of segmenting a large number of images rapidly. Active surface segmentation enabled geometrically accurate 3D reconstruction and visualization of coronary arteries and volumetric measurements.

NASA Discipline Cardiopulmonary↗

NASA standard: Trend analysis techniques

Descriptive and analytical techniques for NASA trend analysis applications are presented in this standard. Trend analysis is applicable in all organizational elements of NASA connected with, or supporting, developmental/operational programs. This document should be consulted for any data analysis activity requiring the identification or interpretation of trends. Trend analysis is neither a precise term nor a circumscribed methodology: it generally connotes quantitative analysis of time-series data. For NASA activities, the appropriate and applicable techniques include descriptive and graphical statistics, and the fitting or modeling of data by linear, quadratic, and exponential models. Usually, but not always, the data is time-series in nature. Concepts such as autocorrelation and techniques such as Box-Jenkins time-series analysis would only rarely apply and are not included in this document. The basic ideas needed for qualitative and quantitative assessment of trends along with relevant examples are presented.

Source record↗

Data analysis software for the autoradiographic enhancement process. Volumes 1, 2, and 3, and appendix

The computer software developed to set up a method for Wiener spectrum analysis of photographic films is presented. This method is used for the quantitative analysis of the autoradiographic enhancement process. The software requirements and design for the autoradiographic enhancement process are given along with the program listings and the users manual. A software description and program listings modification of the data analysis software are included.

Singh, S. P.↗

Modeling Payload Stowage Impacts on Fire Risks On-Board the International Space Station

The purpose of this presentation is to determine the risks of fire on-board the ISS due to non-standard stowage. ISS stowage is constantly being reexamined for optimality. Non-standard stowage involves stowing items outside of rack drawers, and fire risk is a key concern and is heavily mitigated. A Methodology is needed to account for fire risk due to non-standard stowage to capture the risk. The contents include: 1) Fire Risk Background; 2) General Assumptions; 3) Modeling Techniques; 4) Event Sequence Diagram (ESD); 5) Qualitative Fire Analysis; 6) Sample Qualitative Results for Fire Risk; 7) Qualitative Stowage Analysis; 8) Sample Qualitative Results for Non-Standard Stowage; and 9) Quantitative Analysis Basic Event Data.

Anton, Kellie e.↗

NASA standard: Trend analysis techniques

This Standard presents descriptive and analytical techniques for NASA trend analysis applications. Trend analysis is applicable in all organizational elements of NASA connected with, or supporting, developmental/operational programs. Use of this Standard is not mandatory; however, it should be consulted for any data analysis activity requiring the identification or interpretation of trends. Trend Analysis is neither a precise term nor a circumscribed methodology, but rather connotes, generally, quantitative analysis of time-series data. For NASA activities, the appropriate and applicable techniques include descriptive and graphical statistics, and the fitting or modeling of data by linear, quadratic, and exponential models. Usually, but not always, the data is time-series in nature. Concepts such as autocorrelation and techniques such as Box-Jenkins time-series analysis would only rarely apply and are not included in this Standard. The document presents the basic ideas needed for qualitative and quantitative assessment of trends, together with relevant examples. A list of references provides additional sources of information.

Source record↗

Practical Estimates of the Errors Associated with the Governing Shearography Equation

In a series of papers Hung pioneered the development of shearography, an optical NDE technique that detects gradients of surface displacements. Its utility for qualitative flaw characterization has been demonstrated, and while there is a need for using shearography in NDE for quantitative analysis, a large amount of the research has concentrated on the qualitative evaluation of structures and materials. The purpose of this paper is to begin building upon a foundation for the newly emerging quantitative shearography. We begin the analysis by considering the approximations leading to the governing shearography equation.

Fulton, J. P.↗

Preliminary results of SAR soil moisture experiment, November 1975

The experiment was performed using the Environmental Research Institute of Michigan's (ERIM) dual-frequency and dual-polarization side-looking SAR system on board a C-46 aircraft. For each frequency, horizontally polarized pulses were transmitted and both horizontally and vertically polarized return signals were recorded on the signal film simultaneously. The test sites were located in St. Charles, Missouri; Centralia, Missouri; and Lafayette, Indiana. Each test site was a 4.83 km by 8.05 km (3 mile by 5 mile) rectangular strip of terrain. Concurrent with SAR overflight, ground soil samples of 0-to-2.5 cm and 0-to-15 cm layers were collected for soil moisture estimation. The surface features were also noted. Hard-copy image films and the digital data produced via optical processing of the signal films are analyzed in this report to study the relationship of radar backscatter to the moisture content and the surface roughness. Many difficulties associated with processing and analysis of the SAR imagery are noted. In particular, major uncertainty in the quantitative analysis appeared due to the difficulty of quality reproduction of digital data from the signal films.

Choudhury, B. J.↗

Equatorial long waves in geostationary satellite observations and in a multichannel sea surface temperature analysis

Geostationary satellite observations of a zonally oriented sea surface temperature front in the eastern equatorial Pacific were made between 1975 and 1981. Long waves appeared along the front mainly during the summer and fall, except during 1976, the year of an El Nino. The waves have averaged periods of 25 days and wavelengths of 1000 km. At the end of 1981, the long waves also were detected in a new sea surface temperature analysis based on multichannel infrared measurements from a polar-orbiting satellite. This quantitative analysis may improve the ability to resolve low-frequency equatorial wave motions from satellite observations.

Legeckis, R.↗

Planetary and satellite x ray spectroscopy: A new window on solid-body composition by remote sensing

The rings and most of the satellites of the outer planets orbit within the radiation belts of their parent bodies. This is an environment with intense fluxes of energetic electrons. As a result, these objects are strong emitters of X-rays. The characteristic X-ray lines from these bodies depend on atomic composition, but they are not sensitive to how the material is arranged in compounds or mixtures. X-ray fluorescence spectral analysis has demonstrated its unique value in the laboratory as a qualitative and quantitative analysis tool. This technique has yet to be fully exploited in a planetary instrument for remote sensing. The characteristic X-ray emissions provide atomic relative abundances. These results are complementary to the molecular composition information obtained from IR, visible, and UV emission spectra. The atomic relative abundances are crucial to understanding the formation and evolution of these bodies. They are also crucial to the proper interpretation of the molecular composition results from the other sensors. The intensities of the characteristic X-ray emissions are sufficiently strong to be measured with an instrument of modest size. Recent developments in X-ray detector technologies and electronic miniaturization have made possible space-flight X-ray imaging and nonimaging spectrometers of high sensitivity and excellent energy resolution that are rugged enough to survive long-duration space missions. Depending on the application, such instruments are capable of resolving elemental abundances of elements from carbon through iron. At the same time, by measuring the bremsstrahlung intensity and energy spectrum, the characteristics of the source electron flux can be determined. We will discuss these concepts, including estimated source strengths, and will describe a small instrument capable of providing this unique channel of information for future planetary missions. We propose to build this instrument using innovative electronics packaging methods to minimize size and weight.

Chenette, D. L.↗

Supply and Resource Management to Progressively Enable EIMO

BACKGROUND: Current medical operations in Low Earth Orbit (LEO) allow for real-time audio-video communication with a flight surgeon at mission control, resupply, and medical evacuation to earth on the order of hours. As mission profiles change from LEO to the Moon, Mars, and beyond, medical risk as a contribution to overall mission risk is anticipated to rise substantially. Concurrently, due to the distance, the medical systems on board vehicles proposed for these mission types are expected to have reduced mass and volume allocation. Together, astronaut crews will be at a higher risk of major medical events, be required to perform a broader set of tasks, and have substantially reduced resources and support to do so. Earth Independent Medical Operations (EIMO) aims to identify and fill the gaps present in this progressively changing paradigm. OVERVIEW: Medical supplies, resources, and skills are central to spaceflight medical systems. Vehicles used for non-LEO missions are anticipated to be smaller and thus the medical system will also need to have reduced mass, volume, and power. Medical resources are another form of consumable and may need resupply or pre-deployment to meet crew needs. One particular concern is the degradation of medications which become less efficacious and potentially toxic with time, particularly given environmental conditions such as temperature, humidity, oxygen, and radiation which have not yet been fully studied. Supply and resource management in LEO is dependent on resupply, however the supply chain of transporting equipment does not yet have a clear infrastructure for missions beyond LEO. DISCUSSION: EIMO is intended to systemically identify and fill these gaps with forward-looking solutions. In mission monitoring of resources with technology like RFID, improving medical resource longevity, targeted resupply and careful pre-mission planning will be central to facilitate crew health and performance. One approach to optimizing resources is the Informing Mission Planning via Analysis of Complex Tradespaces (IMPACT) tool, which uses probabilistic risk assessment (PRA) to quantitatively predict medical risk and identify resources and skills that mitigate this risk. This evidence based, quantitative analysis prediction tool and several other approaches to meeting the challenge of supply and resource management are discussed.

Arian Anderson↗

A database system to support image algorithm evaluation

The design is given of an interactive image database system IMDB, which allows the user to create, retrieve, store, display, and manipulate images through the facility of a high-level, interactive image query (IQ) language. The query language IQ permits the user to define false color functions, pixel value transformations, overlay functions, zoom functions, and windows. The user manipulates the images through generic functions. The user can direct images to display devices for visual and qualitative analysis. Image histograms and pixel value distributions can also be computed to obtain a quantitative analysis of images.

Lien, Y. E.↗