Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnet test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A methodology to compute the critical current limit in Nb3Sn magnets

Numerous experiments have shown that the loads applied to Nb3Sn strands and cables can reduce their critical current. Experiments, performed on uniaxially loaded strands, allowed to define clear laws to describe the evolution of the critical surface as a function of the applied current, field, temperature and strain. It is, however, still unclear how these laws can be applied to superconducting magnets. The present paper proposes a methodology to estimate the critical current and temperature margin reduction on superconducting magnets due to stress on the superconducting material. The methodology is tested on the MQXF magnets, a quadrupole developed for the High Luminosity LHC project, and successfully validated by comparing computed strain with data from strain gauge measurements. Overall, results suggested that, because of the stresses arising in winding during assembly, cool-down and powering, the current limit of the magnet is lower than the expected short sample limit, and that the most critical region does not coincide with the peak field location.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SPC-2918 Rev 0 MARVEL Test Loop Flowmeters

This specification contains the requirements for the design, manufacture, testing, and delivery of magnetic flowmeters to be installed on the MARVEL Primary Coolant Apparatus Test (PCAT) system. The PCAT system is a heated test loop which will be used to simulate the coolant system of a proposed sodium or NaK cooled microreactor. The system has four identical cooling loops. Installation of flowmeters on all four loops is anticipated at this time, however, the number of flowmeters may be reduced by the Project. Note that the number of flowmeters described herein is not a commitment to a particular number of procured units. The number of flowmeter units procured shall be identified on the purchase order. The MARVEL reactor is still under design, so the PCAT flowmeter design may not be directly transferrable to the reactor. It is intended that the design and development effort for the PCAT flowmeters be leveraged to the extent practical for the reactor flowmeter design.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Fabrication and Testing of 18-mm-Period, 0.5-m-Long Nb 3 Sn Superconducting Undulator

The Advanced Photon Source at Argonne National Laboratory, in collaboration with FNAL and LBNL, is developing a Nb 3 Sn superconducting undulator with the goal of installing this device on the APS storage ring and providing APS users with the novel radiation source. A series of short, similar to ~ 8-cm-long, 18-mm-period undulator prototype magnets have been designed, fabricated, and tested. The same design was scaled to fabricate a 0.5-m-long undulator prototype. Tests of this prototype showed that the designed peak magnetic field of 1.2 T at 850 A was successfully achieved. It represents at least a 20% improvement in comparison with a NbTi SCU having the same period and magnetic gap. Test results and lessons learned from the design process are reported here.

43 PARTICLE ACCELERATORS↗

Analysis and Experimental Testing of a New Type of Variable Stiffness Magnetic Spring with a Linear Stroke Length

In this paper a new type of variable stiffness magnetic spring is proposed. The magnetic spring is composed of radially magnetized outer rotor magnets coupled with axially magnetized inner cylindrical magnets. It is shown that this magnet arrangement creates a highly linear stroke length. By rotating the inner magnetic rotor, the stiffness of the spring can be adjusted. The force as a function of stroke length and torque required to adjust the stiffness were computed using finite element analysis and then verified using an experimental test setup.

16 TIDAL AND WAVE POWER↗

Hydrothermal Growth of Magnetically Frustrated Crystals: Lanthanide Stannate Pyrochlores as a Prototype

One important test bed system for frustrated magnetism is the pyrochlore lattice with the formula A2B2O7 in the cubic space group Fd3(-)m. Both the A and B sites occupy crystallographic trigonal sites and both sites possess a tetrahedral relationship with the other similar metal ion sites. These symmetry relationships generate a 3 D frustrated structure. In frustrated magnetic systems, typically a trivalent lanthanide ion occupies the A site and a magnetically silent tetravalent ion (Ti, Zr, Sn, etc.) occupies the B site. A classical problem related to the crystal growth of these compounds is sample quality. As refractory oxides, the traditional synthesis and crystal growth techniques require high temperatures, which creates two problems that are quite common and endemic to the pyrochlores. One is oxide lattice defects and the other is A/B site disorder. Both issues often occur in the same crystals at the same time and can have a significant impact on the study of physical properties. A hydrothermal approach can be applied to this problem. The relatively low crystal growth temperatures (600-720˚C) greatly minimize nonstoichiometry, lattice defects and A/B site disorder. The reduction of these pervasive imperfections significantly increases the quality of the observed physical property data. This talk will focus on the lanthanide stannates Ln2Sn2O7 as a prototype test bed of these systems. The stannates are among the few building blocks that can stabilize the pyrochlore structure type for all the lanthanides and they serve as an excellent proving ground for a wide range of physical properties. The synthesis and crystal growth of the lanthanide stannates will be reviewed, along with a discussion of some of the physical properties that result from the frustrated magnetic states of these low defect crystals.

Hydrothermal, crystal growth↗

Demonstration of improved laser preheat with a cryogenically cooled magnetized liner inertial fusion platform

We report on progress implementing and testing cryogenically cooled platforms for Magnetized Liner Inertial Fusion (MagLIF) experiments. Two cryogenically cooled experimental platforms were developed: an integrated platform fielded on the Z pulsed power generator that combines magnetization, laser preheat, and pulsed-power-driven fuel compression and a laser-only platform in a separate chamber that enables measurements of the laser preheat energy using shadowgraphy measurements. The laser-only experiments suggest that ~89% ± 10% of the incident energy is coupled to the fuel in cooled targets across the energy range tested, significantly higher than previous warm experiments that achieved at most 67% coupling and in line with simulation predictions. The laser preheat configuration was applied to a cryogenically cooled integrated experiment that used a novel cryostat configuration that cooled the MagLIF liner from both ends. Furthermore, the integrated experiment, z3576, coupled 2.32 ± 0.25 kJ preheat energy to the fuel, the highest to-date, demonstrated excellent temperature control and nominal current delivery, and produced one of the highest pressure stagnations as determined by a Bayesian analysis of the data.

47 OTHER INSTRUMENTATION↗

Design of a Scavenging Pyrrole Additive for High Voltage Lithium-Ion Batteries

We report 1-(dimethylamino) pyrrole (PyDMA) as an electrolyte additive for high voltage lithium-ion batteries based on LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622)//Graphite with an upper cutoff voltage of 4.4 V. Density Functional Theory (DFT) modeling indicates that the unique structure of PyDMA could be effective in preventing the hydrolysis of LiPF 6 in a carbonate electrolyte, mitigating issues related to HF formation. The calculations also indicated that the additive would oxidize at lower potentials than typical electrolyte solvents, which could lead to protective films at the cathode surface. These expectations were tested using Nuclear Magnetic Resonance (NMR) and extensive electrochemical characterization. NMR studies confirmed the superb dehydrating capability of PyDMA, which successfully prevents HF formation even at high water content. Addition of 0.5 wt% PyDMA resulted in improved capacity retention in full-cells, and also in lower levels of transition metal dissolution from the cathode. Incremental capacity (dQ/dV) analysis indicates that benefits of PyDMA at low concentration (0.5–1 wt%) are associated with decreased rates of Li + -trapping reactions, and that higher concentrations of the additive can lead to isolation of cathode domains. Furthermore, our study indicates that PyDMA could be a promising electrolyte additive for high voltage lithium-ion batteries at a low concentration.

25 ENERGY STORAGE↗

The Role of Strong Magnetic Fields in Stabilizing Highly Luminous Thin Disks

Abstract We present and analyze a set of three-dimensional, global, general relativistic radiation magnetohydrodynamic simulations of thin, radiation-pressure-dominated accretion disks surrounding a nonrotating, stellar-mass black hole. The simulations are initialized using the Shakura–Sunyaev model with a mass accretion rate of M ̇ = 3 L Edd / c 2 (corresponding to L = 0.17 L Edd ). Our previous work demonstrated that such disks are thermally unstable when accretion is driven by an α -viscosity. In the present work, we test the hypothesis that strong magnetic fields can both drive accretion through magnetorotational instability and restore stability to such disks. We test four initial magnetic field configurations: (1) a zero-net-flux case with a single, radially extended set of magnetic field loops (dipole), (2) a zero-net-flux case with two radially extended sets of magnetic field loops of opposite polarity stacked vertically (quadrupole), (3) a zero-net-flux case with multiple radially concentric rings of alternating polarity (multiloop), and (4) a net-flux, vertical magnetic field configuration (vertical). In all cases, the fields are initially weak, with a gas-to-magnetic pressure ratio ≳100. Based on the results of these simulations, we find that the dipole and multiloop configurations remain thermally unstable like their α -viscosity counterpart, in our case collapsing vertically on the local thermal timescale and never fully recovering. The vertical case, on the other hand, stabilizes and remains so for the duration of our tests (many thermal timescales). The quadrupole case is intermediate, showing signs of both stability and instability. The key stabilizing factor is the ability of specific field configurations to build up and sustain strong, P mag ≳ 0.5 P tot , toroidal fields near the midplane of the disk. We discuss the reasons why certain configurations are able to do this effectively and others are not. We then compare our stable simulations to the standard Shakura–Sunyaev disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

Search for the chiral magnetic effect in Au+Au collisions at $\sqrt{s_{NN}}$ = 27 GeV with the STAR forward event plane detectors

A decisive experimental test of the Chiral Magnetic Effect (CME) is considered one of the major scientific goals at the Relativistic Heavy-Ion Collider (RHIC) towards understanding the nontrivial topological fluctuations of the Quantum Chromodynamics vacuum. In heavy-ion collisions, the CME is expected to result in a charge separation phenomenon across the reaction plane, whose strength could be strongly energy dependent. The previous CME searches have been focused on top RHIC energy collisions. In this Letter, we present a low energy search for the CME in Au+Au collisions at $\sqrt{s_{NN}}$ = 27 GeV. We measure elliptic flow scaled charge-dependent correlators relative to the event planes that are defined at both mid-rapidity |η| < 1.0 and at forward rapidity 2.1 < |η| < 5.1. We compare the results based on the directed flow plane ( $Ψ$ 1 ) at forward rapidity and the elliptic flow plane ( $Ψ$ 2 ) at both central and forward rapidity. The CME scenario is expected to result in a larger correlation relative to $Ψ$ 1 than to $Ψ$ 2 , while a flow driven background scenario would lead to a consistent result for both event planes. In 10-50% centrality, results using three different event planes are found to be consistent within experimental uncertainties, suggesting a flow driven background scenario dominating the measurement. We obtain an upper limit on the deviation from a flow driven background scenario at the 95% confidence level. This work opens up a possible road map towards future CME search with the high statistics data from the RHIC Beam Energy Scan Phase-II.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic Measurements and Alignment Results of LQXFA/B Cold Mass Assemblies at Fermilab

MQXFA production series quadrupole magnets are being built for the Hi-Lumi (HL) LHC upgrade by the U.S. Accelerator Upgrade Project (US-HL-LHC AUP). These magnets are being placed in pairs, as a cold mass, within cryostats at Fermilab, and are being tested to assess alignment and magnetic performance at Fermilab's horizontal test stand facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis position, and for magnet variations in positioning and local field profile. Here this paper describes the results of the magnetic and alignment measurements which characterize the first LQXFA/B assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monolayer CrCl 3 as an Ideal Test Bed for the Universality Classes of 2D Magnetism

The monolayer halides CrX 3 (X=Cl, Br, I) attract significant attention for realizing 2D magnets with genuine long-range order (LRO), challenging the Mermin-Wagner theorem. In this work, we show that monolayer CrCl 3 has the unique benefit of exhibiting tunable magnetic anisotropy upon applying a compressive strain. This opens the possibility to use CrCl 3 for producing and studying both ferromagnetic and antiferromagnetic 2D Ising-type LRO as well as the Berezinskii-Kosterlitz-Thouless (BKT) regime of 2D magnetism with quasi-LRO. Using state-of-the-art density functional theory, we explain how realistic compressive strain could be used to tune the monolayer's magnetic properties so that it could exhibit any of these phases. Building on large-scale quantum Monte Carlo simulations, we compute the phase diagram of strained CrCl 3 , as well as the magnon spectrum with spin-wave theory. Our results highlight the eminent suitability of monolayer CrCl 3 to achieve very high BKT transition temperatures, around 50 K, due to their singular dependence on the weak easy-plane anisotropy of the material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systematic evaluation of magnetic sensitivities of anisotropic magnetoresistive sensors at liquid helium temperature for superconducting cavities

Trapped magnetic flux in bulk superconductors reduces the quality factor Q in superconducting radio-frequency (SRF) cavities. However, the mechanisms underlying flux trapping and radio-frequency loss are not well understood. Detailed observation of the magnetic distributions is important for understanding such phenomena. Magnetic field mapping is useful for observing the magnetic field distribution around SRF cavities. Measuring the change in the magnetic field around the cavity elucidates the flux trapping behavior. Anisotropic magnetoresistive (AMR) sensors are inexpensive and small devices that can detect magnetic flux density. The magnetic sensitivities of AMR sensors need to be evaluated at liquid helium temperature for the magnetic field mapping of SRF cavities. In this study, a test stand was constructed to calibrate the magnetic sensitivities of AMR sensors in liquid helium, and 110 AMR sensors were tested using this stand. The magnetic sensitivities were evaluated systematically. A solenoid coil was used to control the uniform external magnetic field and to measure the magnetic sensitivity at low temperatures. All AMR sensors exhibited suitable sensitivities to the magnetic field around the SRF cavity. The variation in these sensitivities in all AMR sensors was ~1%. Further, the AMR sensors were found to have sufficient sensitivity for mapping the magnetic field around the exterior surface of the SRF cavity.

43 PARTICLE ACCELERATORS↗

Geometric concepts for stellarator permanent magnet arrays

The development of stellarators that use permanent magnet arrays to shape their confining magnetic fields has been a topic of recent interest, but the requirements for how such magnets must be shaped, manufactured, and assembled remain to be determined. To address these open questions, we have performed a study of geometric concepts for magnet arrays with the aid of the newly developed MAGPIE code. A proposed experiment similar to the National Compact Stellarator Experiment (NCSX) is used as a test case. Two classes of magnet geometry are explored: curved bricks that conform to a regular grid in cylindrical coordinates, and hexahedra that conform to the toroidal plasma geometry. In addition, we test constraints on the magnet polarization. While magnet configurations constrained to be polarized normally to a toroidal surface around the plasma are unable to meet the required magnetic field parameters when subject to physical limitations on the strength of present-day magnets, configurations with unconstrained polarizations are shown to satisfy the physics requirements for a targeted plasma.

stellarator, permanent magnet, optimization↗

A Computational Procedure for Assessing I$_{c}(\varepsilon$) in Nb$_{3}$Sn/Bi-2212 Hybrid Magnets

The critical current of superconductors is commonly measured by testing unloaded wires under an external magnetic field. While stressed by intense Lorentz forces, the existing HTS/LTS superconductors are prone to a reduction in critical current before reaching their structural mechanical limit. Here, in this work, the magnetic and mechanical analysis of the FNAL 4-layer Bi-2212/Nb$_{3}$Sn hybrid dipole magnet is reported, aimed at predicting the critical current degradation for both the superconductors during powering at 16T. All the Rutherford cables in the coils of the hybrid magnet were modeled at the strand level in Ansys APDL with the heterogeneous cable model. Utilizing this detailed geometry, it was possible to evaluate the effects of strain on the critical current degradation for both the Nb$_{3}$Sn and Bi-2212 superconductors under the intense Lorentz forces. The analysis presented in this paper integrates strain-dependent critical current laws, with parameters derived from experimental data, to simulate the hybrid magnet's performance for all possible current-powering configurations. The proposed methodology enables a detailed assessment of conductor integrity and I$_{C}(\varepsilon$) reduction in existing hybrid magnet designs, providing a versatile and rigorous framework for optimizing future high-field hybrid magnets.

D'Agliano, A. [Lawrence Berkeley National Laborato↗

Cold Spray Cobalt Magnetostrictive Electromagnetic Acoustic Transducers for High Temperature Structure Monitoring

The Department of Energy’s Advanced Sensors and Instrumentation program seeks to develop and qualify advanced sensors for the nuclear industry. Reliable high temperature and high radiation sensors for detection and characterization of structural flaws in pipes, vessels, and structurally critical components is a weakness for both conventional light water reactors with coolant T-hot approaching 350oC, and for advanced reactors with T-hot temperatures in excess of 500 to 800oC. Magnetostrictive Electromagnetic Acoustic Transducers using a cold spray cobalt coating have been proposed as a sensor design that can withstand these kinds of temperatures and radiation levels to serve as online sensors to detect flaws before cracks, pits, or erosion/corrosion flaws progress to through-wall failures. This report tests cold spray cobalt as part of a magnetostrictive EMAT for high temperature service. Cobalt is known to have strong magnetostrictive properties however the effect of cold spray application is not well studied. This program was surprised to discover that cold sprayed cobalt exhibited little or no magnetostrictive behavior until it was thermally annealed. Following annealing to 650oC however, cold spray cobalt did exhibit a magnetostrictive response. Work to date prior to this milestone report publication showed that magnetostrictive EMAT was successfully tested to 400oC with an alnico permanent magnet. The program plans to extend testing with an electromagnet to higher temperatures. This follow-on work will be reported under subsequent publications or as a revision to this report.

Glass, Samuel W.↗

Test Results of Fast Decaying Current-Induced AC Losses in SHMS Superconducting Magnets at Jefferson Lab

The 11 GeV Super High Momentum Spectrometer (SHMS) of Hall C, part of the recent 12 GeV accelerator Upgrade at Jefferson Lab, was successfully commissioned in 2017. Fast current discharges of the SHMS Q2, Q3 quadrupoles and dipole superconducting magnets experienced some level of operational difficulty, during commissioning and normal operation. Measurements and analyses demonstrate that the fast current discharge leads to substantial AC losses in the conductor and subsequently triggers a quench-back effect. The details of the measurements and analyses have been reported previously. This paper focuses on the test results of the magnets using a reduced value of the protection dump resistor for each magnet to lower the current decay rate. Finally, the test results confirmed that the reduced dump resistances eliminated the quench-back effect for the SHMS Q2, Q3 and Dipole magnets, thus improving their cryogenic operability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗