Magnetohydrodynamics in free surface liquid metal flow relevant to plasma-facing components

Abstract While flowing Liquid Metal (LM) Plasma-Facing Components (PFCs) represent a potentially transformative technology to enable long-pulse operation with high-power exhaust for fusion reactors, Magnetohydrodynamic (MHD) drag in the conducting LM will reduce the flow speed. Experiments have been completed in the linear open-channel LMX-U device [Hvasta et al 2018 Nucl. Fusion 58 01602] for validation of MHD drag calculations with either insulating or conducting walls, with codes similar to those used to design flowing LM PFCs for a Fusion Nuclear Science Facility [Kessel et al 2019 Fusion Sci. Technol . 75 886]. We observe that the average channel flow speed decreased with the use of conducting walls and the strength of the applied transverse magnetic field. The MHD drag from the retarding Lorentz force resulted in an increase of the LM depth in the channel that ‘piled up’ near the inlet, but not the outlet. As reproduced by OpenFOAM and ANSYS CFX calculations, the magnitude and characteristics of the pileup in the flow direction increased with the applied traverse magnetic field by up to 120%, as compared to the case without an applied magnetic field, corresponding to an average velocity reduction of ∼45%. Particle tracking measurements confirmed a predicted shear in the flow speed, with the surface velocity increasing by 300%, despite the 45% drop in the average bulk speed. The MHD effect makes the bulk flow laminarized but keeps surface waves aligned along the magnetic field lines due to the anisotropy of MHD drag. The 3D fringe field and high surface velocity generate ripples around the outlet region. It was also confirmed that the MHD drag strongly depends on the conductivity of the channel walls, magnetic field, and volumetric flow rate, in agreement with the simulations and a developed analytical model. These validated models are now available to begin to determine the conditions under which the ideal LM channel design of a constant flow speed and fluid depth could be attained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oscillating-flow loss test results in rectangular heat exchanger passages

Test results of oscillating flow losses in rectangular heat exchanger passages of various aspect ratios are given. This work was performed in support of the design of a free-piston Stirling engine (FPSE) for a dynamic space power conversion system. Oscillating flow loss testing was performed using an oscillating flow rig, which was based on a variable stroke and variable frequency linear drive motor. Tests were run over a range of oscillating flow parameters encompassing the flow regimes of the proposed engine design. Test results are presented in both tabular and graphical form and are compared against analytical predictions.

Wood, J. Gary↗

Stirling System Modeling for Space Nuclear Power Systems

A dynamic model of a high-power Stirling convertor has been developed for space nuclear power systems modeling. The model is based on the Component Test Power Convertor (CTPC), a 12.5-kWe free-piston Stirling convertor. The model includes the fluid heat source, the Stirling convertor, output power and heat rejection. The Stirling convertor model includes the Stirling cycle thermodynamics, heat flow, mechanical mass-spring damper systems, and the linear alternator. The model was validated against test data. Both nonlinear and linear versions of the model were developed. The linear version algebraically couples two separate linear dynamic models; one model of the Stirling cycle and one model of the thermal system, through the pressure factors. Future possible uses of the Stirling system dynamic model are discussed. A pair of commercially available 1-kWe Stirling convertors is being purchased by NASA Glenn Research Center. The specifications of those convertors may eventually be incorporated into the dynamic model and analysis compared to the convertor test data. Subsequent potential testing could include integrating the convertors into a pumped liquid metal hot-end interface. This test would provide more data for comparison to the dynamic model analysis.

Lewandowski, Edward J.↗

Stirling System Modeling for Space Nuclear Power Systems

A dynamic model of a high-power Stirling convertor has been developed for space nuclear power systems modeling. The model is based on the Component Test Power Convertor (CTPC), a 12.5-kWe free-piston Stirling convertor. The model includes the fluid heat source, the Stirling convertor, output power, and heat rejection. The Stirling convertor model includes the Stirling cycle thermodynamics, heat flow, mechanical mass-spring damper systems, and the linear alternator. The model was validated against test data. Both nonlinear and linear versions of the model were developed. The linear version algebraically couples two separate linear dynamic models; one model of the Stirling cycle and one model of the thermal system, through the pressure factors. Future possible uses of the Stirling system dynamic model are discussed. A pair of commercially available 1-kWe Stirling convertors is being purchased by NASA Glenn Research Center. The specifications of those convertors may eventually be incorporated into the dynamic model and analysis compared to the convertor test data. Subsequent potential testing could include integrating the convertors into a pumped liquid metal hot-end interface. This test would provide more data for comparison to the dynamic model analysis.

Lewandowski, Edward J.↗

Fuel Bonding and its Impact on Axial Gas Communication Behavior in Light-Water Reactor Fuel Rods

Axial gas communication concerns the flow along the axial axis of nuclear fuel rods during ramp and loss of coolant accident (LOCA) conditions. During power ramps, the higher linear heat generation rate may cause fuel-to-clad gap closure that may prevent transport of released fission gases to the plenum. Upon reduction in power the gas then can communicate to the plenum. This phenomenon has been experimentally observed by short power dips during ramp experiments completed at the Risø reactor. At higher burnups it is observed that the UO2 fuel and Zircaloy cladding forms a chemical bond. This bond results in complete closure of the gap. When these high burnup rods are subjected to a LOCA, the bond has implications on both the mechanical response (i.e., ballooning) of the cladding and subsequent fuel relocation and axial gas communication. In the LOCA scenario, gas communication is of interest in two different regimes: 1) pre-rupture communication from the plenum towards the lower pressure ballooning area and 2) the post-rupture depressurization of the plenum to the external system pressure. In both regimes the presence of a fuel-to-cladding bond will impact the rate of depressurization. In this work we present a fuel-to-clad bonding model that is coupled to an existing axial gas communication model framework in the BISON fuel performance code. The effect of considering the bond on fuel performance modeling predictions is presented through comparisons to existing experimental data. Experiments considered include several rods from the Halden IFA-650 test series. An evaluation on a full-length rod that explores the combined effect of plenum size and bonding status on axial gas communication behavior is also presented.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operating characteristics of the Russian D-55 thruster with anode layer

Performance measurements of a Russian engineering-model Thruster with Anode Layer (TAL) were obtained as part of a program to evaluate the operating characteristics of Russian Hall-thruster technology. The TAL model D-55 was designed to operate in the 1-2 kW power range on xenon. When received, the thruster had undergone only a few hours of acceptance testing by the manufacturer. Direct thrust measurements were obtained at a background pressure of 0.0003 Pa (2 x 10(exp -6) torr) at power levels ranging from 0.3 kW to 2.1 kW. At the nominal power level of 1.3 kW, a specific impulse level of 1600 s with a corresponding efficiency of 0.48 was attained. At all flow rates tested, the efficiency increased linearly with specific impulse until a maximum was reached, and then the efficiency leveled off. Increasing the anode flow rate shifted the efficiency upward, reaching 0.50 at 1850 s specific impulse. The thruster was equipped with inner and outer electromagnets which were isolated from the discharge and from each other. Variation of the magnetic field, obtained by changing the currents through the magnets, had little effect on performance, except at current levels below 70 percent of nominal. For a given operating condition, the performance was slightly affected by facility pressure. As the pressure was increased by a factor of thirty to 0.008 Pa (6 x 10(exp -5) torr), the current steadily increased by 4 percent, and the thrust increased by 2 percent. Performance comparisons were made with the Stationary Plasma Thruster, and the efficiency and specific impulse values were similar at power levels ranging from 0.9 kW to 1.5 kW. Endurance testing was not performed, and comparisons of lifetime were not made.

Sankovic, John M.↗

Pickup protons and water ions at Comet Halley - Comparisons with Giotto observations

The cometary ion pickup process along the sun-comet line at Comet Halley is investigated using a quasi-linear diffusion model including both pitch angle and energy diffusion, adiabatic compression, and convective motion with the solar wind flow. The model results are compared with energetic ion distributions observed by instruments on board the Giotto spacecraft. The observed power spectrum index of magnetic turbulence (gamma) is 2-2.5. The present simulation shows that when gamma was 2, the calculated proton distributions were much more isotropic than the observed ones. The numerical solutions of the quasi-linear diffusion equations show that the isotropization of the pickup ion distribution, particularly at the pickup velocity, is not complete even close to the bow shock. Given the observed turbulence level, quasi-linear theory yields pickup ion energy distributions that agree with the observed ones quite well and easily produces energetic ions with energies up to hundreds of keV.

Ye, G.↗

Effect of aspect ratio on the air forces and moments of harmonically oscillating thin rectangular wings in supersonic potential flow

This report treats the effect of aspect ratio on the air forces and moments of an oscillating flat rectangular wing in supersonic potential flow. The linearized velocity potential for the wing undergoing sinusoidal torsional oscillations simultaneously with sinusoidal vertical translations is derived in the form of a power series in terms of a frequency parameter. The series development is such that the differential equation for the velocity potential is satisfied to the required power of the frequency parameter considered and the linear boundary conditions are satisfied exactly. The method of solution can be utilized for other plan forms, that is, plan forms for which certain steady-state solutions are known.

Watkins, Charles E↗

SAM™ (System Advisor Model™) [SWR-16-02, SWR-10-13]

See the SAM™ website to build a desktop version of the National Laboratory of the Rockies' (NLR's) System Advisor Model™ (SAM). https://sam.nlr.gov/ The System Advisor Model™ (SAM™) is a free techno-economic software model that facilitates decision-making for people in the renewable energy industry: -Project managers and engineers -Policy analysts -Technology developers -Researchers SAM can model many types of renewable energy systems: -Photovoltaic systems, from small residential rooftop to large utility-scale systems -Battery storage with Lithium ion, lead acid, or flow batteries for front-of-meter or behind-the-meter applications -Concentrating Solar Power systems for electric power generation, including parabolic trough, power tower, and linear Fresnel -Industrial process heat from parabolic trough and linear Fresnel systems -Wind power, from individual turbines to large wind farms -Marine energy wave and tidal systems -Solar water heating -Fuel cells -Geothermal power generation -Biomass combustion for power generation -High concentration photovoltaic systems SAM's financial models are for the following types of projects: -Residential and commercial projects where the renewable energy system is on the customer side of the electric utility meter (behind the meter), and power from the system is used to reduce the customer's electricity bill. -Power purchase agreement (PPA) projects where the system is connected to the grid at an interconnection point, and the project earns revenue through power sales. The project may be owned and operated by a single owner or by a partnership involving a flip or leaseback arrangement. -Third party ownership where the system is installed on the customer's (host) property and owned by a separate entity (developer), and the host is compensated for power generated by the system through either a PPA or lease agreement. For a more detailed description of SAM, see Blair et al. (2018), System Advisor Model (SAM) General Description (Version 2017.9.5), NREL/TP-6A20-70414. https://www.nrel.gov/docs/fy18osti/70414.pdf

Ryberg, David↗

Experimental and analytical investigation of a fluidic power generator

A combined experimental and analytical investigation was performed to understand the various fluid processes associated with the conversion of flow energy into electric power in a fluidic generator. Experiments were performed under flight-simulated laboratory conditions and results were compared with those obtained in the free-flight conditions. It is concluded that the mean mass flow critically controlled the output of the fluidic generator. Cross-correlation of the outputs of transducer data indicate the presence of a standing wave in the tube; the mechanism of oscillation is an acoustic resonance tube phenomenon. A linearized model was constructed coupling the flow behavior of the jet, the jet-layer, the tube, the cavity, and the holes of the fluidic generator. The analytical results also show that the mode of the fluidic power generator is an acoustical resonance phenomenon with the frequency of operation given by f approx = a/4L, where f is the frequency of jet swallowing, a is the average speed of sound in the tube, and L is the length of the tube. Analytical results further indicated that oscillations in the fluidic generator are always damped and consequently there is a forcing of the system in operation.

Sarohia, V.↗

Optimal Network Topology for Node-Breaker Representations With AC Power Flow Constraints

It has been demonstrated that network topology optimization (NTO) may change the topology of power system networks, and consequently, provide additional flexibility to reduce network congestion and violations. Most NTO problems are formulated based on the bus-branch model in which it is challenging to represent a realistic picture of all substation configurations. In this paper, we explore advantages of substation reconfiguration modeling based on node-breaker representations for NTO problem with full nonlinear alternating current power flow. It also proposes a tailored solution algorithm to solve this nonconvex mixed-integer nonlinear programming through the outer approximation method. The proposed solution approach iterates between a mixed-integer linear programming and a nonlinear subproblem. Additional enhancements to further accelerate the iteration process are illustrated. Numerical case studies demonstrate the relative economic and operational impact of optimal network topology with node-breaker representations.

42 ENGINEERING↗

Additively manufactured electrodes for plasma and power-flow studies in high-power transmission lines on the 1-MA MAIZE facility

Power-flow studies on the 30-MA, 100-ns Z facility at Sandia National Laboratories have shown that plasmas in the facility’s magnetically insulated transmission lines (MITLs) and double post-hole convolute can result in a loss of current delivered to the load. To study power-flow physics on the 1-MA, 100-ns MAIZE facility at the University of Michigan, planar MITL loads and planar post-hole convolute loads have been developed that extend into the lines of sight for various imaging diagnostics on MAIZE. These loads use 3D-printed dielectric support structures lined with thin foils of either aluminum or stainless steel. Here, the metal foils serve as the current-carrying power-flow surfaces, which generate plasma during the current pulse. The foil thickness (50 µm) and widths (11.5–16 mm) are selected to ensure a sufficient linear current density (0.5–0.7 MA/cm) for plasma formation. Laser backlighting (532 nm) and visible-light self-emission imaging capture the overall plasma evolution in the anode–cathode gaps, including the gap closure velocities (1–4 cm/μs).

47 OTHER INSTRUMENTATION↗

In situ process diagnostics of silane plasma for device-quality a-Si:H deposition

Coherent anti-Stokes Raman spectroscopy (CARS) and mass spectrometry (MS) have been applied to in situ process diagnostics of a silane plasma for device-quality a-Si:H film deposition. Silane depletion was directly measured by CARS and is linearly dependent on RF power in the region of 4-12 W with a slope of 0.5 percent/mW-sq cm. The depletion is also dependent on SiH4 flow rate starting with a 50 percent depletion at a low flow rate of 5.6 sccm and asymptotically approaching an 8 percent depletion at a flow rate of 80 sccm. The mass spectral line signal intensity of disilane increases with RF power and shows an apparent transition at 6 W. Disilane formation in silane plasma, film deposition rate, and silane depletion ratio as a function of the RF power indicate that the film growth mechanism in the low-power region of 3.5-6.5 W is substantially different from that in the high-power region of 6.5-12 W.

Shing, Y. H.↗

Measurement of Screen-Size Effects on Intensity, Scale, and Spectrum of Turbulence in a Free Subsonic Jet

The results are reported of hot-wire anemometer measurements of the fluctuating longitudinal component of the turbulent velocities in the mean flow downstream of screens in an air jet. These measurements have been analyzed by well-established techniques to give the influence of tile screen mesh size on the turbulent intensity, scale, and the power-spectral-density. The results show a linear dependence of the intensity upon the screen mesh size for locations within the central core of the air jet. The spectral-density curves show that the screens redistribute the turbulent energy from the low frequencies (<1000 cps) to the high frequencies (>1000 cps). The effects of the screens are overwhelmed in the mixing region of the jet flow by the turbulence levels existing there. The large pressure drops occurring across the screens reduce the velocity of the jet as compared to the jet without screens by approximately one-third for the velocity and range of mesh sizes investigated and reported in this report. The turbulence scale is a linear function of distance from the nozzle exit and is somewhat greater than comparable jets without screens.

Howard, Charles D.↗

Reactor Simulator Testing

As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz. Keywords: fission, space power, nuclear, liquid metal, NaK.

Schoenfeld, Michael P.↗

Analysis of laminar flow between stationary and rotating disks with inflow

The laminar flow between a rotating and a stationary disk with inflow was analyzed. Solutions to the dimensionless governing equations are sought by expanding each of the velocity components in powers of inverse radius. The equations to leading order are those for the configuration with no inflow. The subsequent orders yield sets of linear ordinary differential equations. Solutions are obtained for the first two of these subsequent orders. The solutions indicate that inflow tends to increase the magnitude of the azimuthal velocity in the flow between the two disks and to decrease the torque on the rotating disk. For Prandtl number one, an energy integral is obtained which relates the temperature distribution to the velocity distribution for all Reynolds numbers and therefore eliminates the needs for separate solution of the energy equation.

Rohatgi, U.↗

Optimal PMU Restoration for Power System Observability Recovery After Massive Attacks

Cyber-physically resilient power system operation requires rapid recovery of situational awareness after disastrous scenarios such as massive cyber attacks. In this article, the concept of optimal sequential restoration of Phasor Measurement Units is introduced, aiming at rapid recovery of power system observability in post-attack scenarios. Additionally, the observability recovery problem is formulated as a Mixed Integer Linear Programming problem to maximize the cumulative observability level gained over time during the restoration process. Three alternative objective functions-maximizing the number of observable buses, the number of observable branches, and the total amount of observable power flow-are considered. The effectiveness of the proposed optimal strategy is verified by comparing it with heuristic approaches on the IEEE 57-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrothermal oscillations and the quasilinear theory of electron enthalpy fluctuations in magnetohydrodynamic generators and magnetoplasmadynamic arc thrusters

Flucturations in electron density and temperature coupled through OHM's Law are studied for MHD power generator and MPD arc thruster applications. The dispersion relation based on linear theory is derived, and the two limiting cases of infinite ionization rate and frozen flow are examined. The nonlinear effects of the frozen flow case are then studied in the quasilinear limit. Equations are derived for the amplitude of the fluctuation and its effect upon Ohm's Law and the electron temperature equation. Conditions under which a steady state can exist in the presence of the fluctuation are examined, and effective transport properties are determined.

Smith, J. M.↗