Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Optical study of charge exchange collisions between He+ and CO2.

Helium ions were produced in an electron bombardment ion source and directed into a gas cell containing carbon dioxide. A Wien filter placed between the ion source and the gas cell insured that only singly charged helium ions reached the cell. The spectrum obtained for the bombardment of carbon dioxide with the helium ions at 1200 eV is shown in a graph. Prominent features of the lower spectrum are two atomic lines at 3889 and 4471 A.

Coplan, M. A.↗

Arcing in space structures in low Earth orbit

This report describes results of an experimental and theoretical program to investigate arcing of structures containing dielectric and conducting materials when they are biased negatively with respect to a plasma. An argon ion source generated Ar(+) ions of directed energy 20 to 40 eV and density approximately 10(exp 7) cm(exp -3) that impinged upon samples containing a dielectric material on top of a negatively biased Kovar plate. Arcing events were studied for bias voltages between -300 and -1000V with respect to the ion beam. The samples were Dow Corning 93-500 adhesive on Kovar, fused silica cover slips bonded on Kovar, and silicon solar cells mounted on Kovar. Measurements of discharge current, Kovar plate voltage, and radiation from the arc versus time were carried out. Microsecond duration exposure images and optical spectra in the 0.24 to 0.40 micron band were also acquired during arcing events. Arcing events were found to be associated with exposed adhesive and means were found to eliminate arcing altogether. The charging of a silica cover plate and the fields around the plate were calculated using a particle-in-cell code. Models were developed to explain the ignition of the arc and the physical processes occurring during the discharge.

Upschulte, B. L.↗

First Results From the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14,2005. The GCMS was part of the instrument complement on the Probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns. The mass spectrometer employed five electron impact ion sources with available electron energies of either 70 or 25 eV. Three ion sources served as detectors for the GC columns and two were dedicated to direct atmosphere sampling and ACP gas sampling, respectively. The GCMS gas inlet was heated to prevent condensation, and served to evaporate surface constituents after impact.

Niemann, Hasso B.↗

International Space Station Major Constituent Analyzer On-orbit Performance

The Major Constituent Analyzer (MCA) is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic change-out, including the ORU 02 analyzer and the ORU 08 Verification Gas Assembly. The most recent ORU 02 and ORU 08 assemblies are operating nominally. For ORU 02, the ion source filaments and ion pump lifetime continue to be key determinants of MCA performance. Additionally, testing is underway to evaluate the capacity of the MCA to analyze ammonia. Finally, plans are being made to bring the second MCA on ISS to an operational configuration.

Gardner, Ben D.↗

International Space Station Major Constituent Analyzer On-Orbit Performance

The Major Constituent Analyzer (MCA) is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic change-out, including the ORU 02 analyzer and the ORU 08 Verification Gas Assembly. The most recent ORU 02 and ORU 08 assemblies in the LAB MCA are operating nominally. For ORU 02, the ion source filaments and ion pump lifetime continue to be key determinants of MCA performance. Finally, the Node 3 MCA is being brought to an operational configuration.

Gardner, Ben D.↗

Numerical Investigation of Ion Transport in the MOMA Ion Mass Spectrometer

The Mars Organic Molecule Analyzer (MOMA) is a miniature ion trap mass spectrometer designed for the upcoming ExoMars Rover mission. The spectrometer uses laser desorption to ionize a Martian soil sample within an instrument internal clean zone maintained at ambient Martian pressure. A high-speed aperture valve transiently opens to allow ionized constituents, along with the ambient gas, to enter a vacuum cavity containing a linear ion trap mass spectrometer. The ambient clean zone and the vacuum cavity are connected via a few centimeter long aperture valve ion guide tube. In this paper, we present results from a recently completed numerical investigation of ion transport from the ion source across the ion guide. Specifically, we focus on collisional coupling between ions and the neutral molecules flowing into the vacuum cavity. The simulation domain contains the ambient region, and we consider the variation in ion conductance with ambient pressure. We also analyze the impact of a fixed potential bias applied to the aperture valve. Simulations are performed with a two-dimensional axisymmetric PIC / DSMC code Starfish. Numerical results are compared to experimental data.

Breida, Lubos↗

Miniaturized high-resolution mass/charge spectrograph /design study/

Use of a double-focusing mass/charge spectrograph weighing less than 25 pounds is feasible for solar wind experiments. Instrument has a parallel-plate energy filter between the ion source and the double focusing units which alleviates the problem of designing an ion source of small energy spread.

Taylor, L. H.↗

Measurement of mass distribution of chemical species in aerosol particles

Aerosols may be generated through the nebulizing of solutions and the evaporation of their solvent, leaving the dry solute particles. Attention is presently given to a method for the direct determination of the masses of chemical species in individual aerosol particles on a continuous, real-time basis, using mass spectrometry. After the aerosol particles are introduced into the ion source of a quadrupole mass spectrometer, the particles impinge on a hot rhenium filament in the mass spectrometer's ion source. The resulting vapor plume is ionized by electron bombardment, and a pulse of ions is generated by each particle. The intensities of different masses in the ion pulses can then be measured by the mass spectrometer.

Sinha, M. P.↗

A neutral-atmosphere composition experiment for the Atmosphere Explorer-C, -D, and -E.

The neutral-atmosphere composition experiment instrumentation is designed to obtain in-situ measurements of neutral thermosphere composition from Atmosphere Explorer-C, -D, and -E. The system is based on previously flown OGO-6 and San Marco-3 composition instruments. The mass-spectrometer sensor includes a gold-plated thermalizing chamber and ion source, a hyperbolic rod quadrupole analyzer, and an off-axis electron multiplier. Automatic ion-source sensitivity control and pulse-counting techniques provide density measurement capability from approximately 125 to 1000 km altitude. The normal operating mode includes measurement at all masses in the range of 1 to 44 amu, with emphasis on hydrogen, helium, oxygen, nitrogen, and argon.

Pelz, D. T.↗

Molecular beam facility for studying mass spectrometer performance

An apparatus which produces neutral gas beams in the velocity range from thermal to 6 km/s makes possible studies simulating the motion of instruments through tenuous atmospheres. Use of the apparatus in studying the response of an open-source mass spectrometer is examined. Experiments performed include responses when the instrument is in a normal mode of operation, when the ion source potentials are adjusted to reject striking gas particles, when the beam is restricted so that portions of the ion source are struck, and when the beam strikes at angles other than normal incidence. Results indicate specular radiation of particles out of the source and stagnation ratios close to unity for normal operation. Retarding potential studies dropped the sensitivity by a factor of about 10, and as angles of attack are varied, the effect was found to depend upon beam velocity and the way the ions are initially accelerated.

Ballenthin, J. O.↗

Investigation of International Space Station Major Constituent Analyzer Anomalous ORU 02 Performance

The Major Constituent Analyzer (MCA) is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. In 2011, two MCA ORU 02 analyzer assemblies experienced premature on-orbit failures. These failures were determined to be the result of off-nominal ion source filament performance. Recent product improvements to ORU 02 designed to improve the lifetime of the ion pump also constrained the allowable tuning criteria for the ion source filaments. This presentation describes the filament failures as well as the corrective actions implemented to preclude such failures in the future.

Gardner, Ben D.↗

Survey of ion plating sources

Based on the type of evaporation source, gaseous media and mode of transport, the following is discussed: resistance, electron beam, sputtering, reactive and ion beam evaporation. Ionization efficiencies and ion energies in the glow discharge determine the percentage of atoms which are ionized under typical ion plating conditions. The plating flux consists of a small number of energetic ions and a large number of energetic neutrals. The energy distribution ranges from thermal energies up to a maximum energy of the discharge. The various reaction mechanisms which contribute to the exceptionally strong adherence - formation of a graded sustrate/coating interface are not fully understood, however the controlling factors are evaluated. The influence of process variables on the nucleation and growth characteristics are illustrated in terms of morphological changes which affect the mechanical and tribological properties of the coating.

Spalvins, T.↗

DE-2 mass spectrometer observations relevant to the Shuttle glow

A comparison of satellite mass spectrometer data from Dynamics Explorer-2 and Atmosphere Explorer-C and -D provides new evidence supporting the hypothesis that NO2 is the source of the observed continuum glow near ram-facing surfaces of the Space Shuttle. Surface reactions of thermospheric N and O in mass spectrometer ion sources produce NO and NO2 in amounts highly dependent on surface temperature and composition, with direct exposure of ion source surfaces to rammed gas a necessary condition for the production of large amounts of NO2. Initial orbit data indicate that a period of surface conditioning is necessary before these odd nitrogen molecules can be produced efficiently.

Engebretson, M. J.↗

Molecular beam simulation of planetary atmospheric entry - Some recent results.

Progress is reported in the development of molecular beam techniques to simulate entry into planetary atmospheres. Molecular beam sources for producing fast beams containing CO2 and atomic oxygen are discussed. Results pertinent to the design and calibration of a mass spectrometer ion source for measurement of the Martian atmosphere during the free molecule portion of the entry trajectory are also presented. The shortcomings and advantages of this simulation technique are discussed, and it is demonstrated that even with certain inadequacies much information useful to the ion source design was obtained. Particularly, it is shown that an open-cavity configuration retains sensitivity to atomic oxygen, provides reasonable signal enhancement from the stagnation effect, is not highly sensitive to pitch and yaw effects, and presents no unforeseen problems in measuring CO2 or atomic oxygen.

French, J. B.↗

Segmented Ion Engine Plume Characteristics

Preliminary evaluation of the segmented ion thruster (SIT) ion beam characteristics was performed by measuring the two dimensional ion current density distribution at four axial locations downstream from the thruster. Current density profiles were measured with the concurrent operation of multiple ion sources. Preliminary assessments regarding symmetry of the plume, characterization of plume development as a function of axial position, and the interactions of multiple simultaneously operating ion sources were conducted. A numerical integration scheme was applied to the acquired data to determine the total beam current. A qualitative analysis of the downstream development of the ion beam was conducted. Most of the data acquired so far has been on somewhat of a trial basis and extensive testing is scheduled to resume in August 1994.

ion↗

Atomic oxygen-metal surface studies as applied to mass spectrometer measurements of upper planetary atmospheres

The problem of atomic oxygen loss in mass spectrometer ion sources can be reduced to an understanding of the possible surface interactions between oxygen atoms and the metal surface of the ion source. Results are presented for an experimental study in which an atomic oxygen beam apparatus and a mass spectrometer were used to measure the oxygen atom reflection, recombination, general surface reaction, and occlusion probabilities on six different engineering surfaces as a function of atomic oxygen exposure. The materials studied are gold, Nichrome V, aluminum, titanium, silver, and platinum. The variation in measured reflection probability seems to occur with metals that form oxides, Nichrome V being stable in terms of reflection stability. Recombination is observed an all surfaces except aluminum and platinum. Variation in the complete set of measurements in a single experiment is the result of varying surface conditions.

Sjolander, G. W.↗

The open-source neutral-mass spectrometer on Atmosphere Explorer-C, -D, and -E.

The open-source mass spectrometer will be used to obtain the number densities of the neutral atmospheric gases in the mass range 1 to 48 amu at the satellite location. The ion source has been designed to allow gas particles to enter the ionizing region with the minimum practicable number of prior collisions with surfaces. This design minimizes the loss of atomic oxygen and other reactive species due to reactions with the walls of the ion source. The principal features of the open-source spectrometer and the laboratory calibration system are discussed.

Nier, A. O.↗