Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An Analysis of Post Attack Impacts and Effects of Learning Parameters on Vulnerability Assessment of Power Grid

Due to the increasing number of heterogeneous devices connected to electric power grid, the attack surface increases the threat actors. Game theory and machine learning are being used to study the power system failures caused by external manipulation. Most of existing works in the literature focus on one-shot process of attacks and fail to show the dynamic evolution of the defense strategy. In this paper, we focus on an adversarial multistage sequential game between the adversaries of the smart electric power transmission and distribution system. We study the impact of exploration rate and convergence of the attack strategies (sequences of action that creates large scale blackout based on the system capacity) based on the reinforcement learning approach. We also illustrate how the learned attack actions disrupt the normal operation of the grid by creating transmission line outages, bus voltage violations, and generation loss. This simulation studies are conducted on IEEE 9 and 39 bus systems. The results show the improvement of the defense strategy through the learning process. The results also prove the feasibility of the learned attack actions by replicating the disturbances created in simulated power system.

attack impacts↗

Evaluating Interconnection Queue Impacts Using Hosting Capacity Analysis

The interconnection queue has been identified as a bottleneck in the efforts to shift the nations generation resources towards renewable sources and meet various state and federal goals. Efforts such as the interconnection innovation e-Xchange (i2X) are therefore trying to come up with ways in which the queue could be altered to make interconnection faster, cheaper, and fairer. This paper proposes using hosting capacity analysis methods to simulate the evolution of a power system as new resources are added. Modeling the interconnection process in this way enables simulation based study of various policy decisions for queue management and cost allocation. Sample results are presented to illustrate how some queue modifications might play out both in distribution and transmission systems.

Distributed Energy Resources, Interconnection↗

Simulation Analysis of Mode Hopping Impacts on OFDR Sensing Performance

This article examines the impacts of mode hopping on the sensing performance of optical frequency domain reflectometry (OFDR) and explores the potential for developing economical OFDR interrogators employing low-cost distributed feedback (DFB) lasers. By conducting numerical simulations, this study reveals that mode hopping has minimal effects on distance sensing measurements in free space due to the limited duration of beat interference signal at the incorrect frequency within the coherence length. Additionally, the simulations indicate that mode hopping only slightly affects the distributed strain sensing of OFDR, resulting in an error range of less than ±1µε when 100µε is applied to the sensing fiber. These findings highlight the potential of using low-cost DFB lasers with a 1-nm wavelength sweep range and a 1-MHz linewidth as tunable laser sources in OFDR while maintaining reliable and accurate sensing performance.

Wang, Qirui (ORCID:0000000336532984)↗

Simulator Data Analysis to Inform Digitalized Environment Impacts on Human Reliability

The U.S. Nuclear Regulatory Commission (NRC) has developed a human reliability analysis (HRA) method, termed the Integrated Human Event Analysis System for Event and Condition Assessment (IDHEAS-ECA), in order to estimate human error probabilities (HEPs) in risk-informed regulatory applications. To update the quantification part of IDHEAS-ECA, the NRC required human performance and error data from fully digitalized main control rooms (MCRs); therefore, it requested that Idaho National Laboratory (INL) revisit previous data collection studies and investigate how the following three factors impact human reliability: self-checking, peer-checking, and automation. The HRA data collection studies revisited were the Human Reliability Data Extraction (HuREX) project, developed by the Korea Atomic Energy Research Institute (KAERI), and the Simplified Human Error Experimental Program (SHEEP), developed by INL. HuREX is a representative HRA data collection study that collects human reliability data from full-scope simulators staffed by licensed operators. SHEEP, on the other hand, has been proposed to complement such full-scope studies by collecting data via simplified simulators staffed by non-licensed student operators. In the HuREX study, KAERI collected HRA data from fully digitalized MCRs for the Advanced Power Reactor (APR)–1400. The SHEEP data were obtained from simplified simulators that partially mimicked the features of digitalized MCRs. The present report mainly discusses how the impacts of the aforementioned three factors on human errors were derived from these two data collection studies.

99 GENERAL AND MISCELLANEOUS↗

The Atacama Cosmology Telescope: Mitigating the Impact of Extragalactic Foregrounds for the DR6 Cosmic Microwave Background Lensing Analysis

We investigate the impact and mitigation of extragalactic foregrounds for the cosmic microwave background (CMB) lensing power spectrum analysis of Atacama Cosmology Telescope (ACT) data release 6 (DR6) data. Two independent microwave sky simulations are used to test a range of mitigation strategies. We demonstrate that finding and then subtracting point sources, finding and then subtracting models of clusters, and using a profile bias-hardened lensing estimator together reduce the fractional biases to well below statistical uncertainties, with the inferred lensing amplitude, A lens , biased by less than 0.2σ. We also show that another method where a model for the cosmic infrared background (CIB) contribution is deprojected and high-frequency data from Planck is included has similar performance. Other frequency-cleaned options do not perform as well, either incurring a large noise cost or resulting in biased recovery of the lensing spectrum. In addition to these simulation-based tests, we also present null tests on the ACT DR6 data for sensitivity of our lensing spectrum estimation to differences in foreground levels between the two ACT frequencies used, while nulling the CMB lensing signal. These tests pass whether the nulling is performed at the map or bandpower level. The CIB-deprojected measurement performed on the DR6 data is consistent with our baseline measurement, implying that contamination from the CIB is unlikely to significantly bias the DR6 lensing spectrum. This collection of tests gives confidence that the ACT DR6 lensing measurements and cosmological constraints presented in companion papers to this work are robust to extragalactic foregrounds.

79 ASTRONOMY AND ASTROPHYSICS↗

Scenario-based analysis of electric vehicle adoption in the United States: Technology, infrastructure, and electricity pricing

This work investigates the impact of battery technology advancement, charging infrastructure development, and time-of-use (TOU) electricity pricing on vehicle adoption by 6 powertrain types in the United States through 2050. Using the Market Acceptance of Advanced Automotive Technologies (MA3T) model, we simulate 15 scenarios, examining individual cost factors and their combinations. We assess outcomes through market share, consumer surplus, and energy consumption. Results show that battery cost reductions are the strongest driver of EV adoption, increasing 2050 battery electric vehicle (BEV) share by 27 percentage points over baseline, raising annual consumer surplus by $511 per household, and reducing cumulative energy consumption by 16,610 trillion Btu. These gains are two to five times larger than those from other individual factors. Reducing home charging installation costs produces moderate impact, while TOU pricing alone yields only small gains, raising 2050 BEV market share by 1–2 percentage points. However, when cost factor improvements are combined, their effects are amplified beyond simple additivity. Pairing modest battery cost reductions with charging installation cost reductions and TOU pricing results in the largest 2050 BEV sales combined impact. The analysis demonstrates that moderate progress targeting multiple cost barriers may be more impactful than focusing on any single barrier.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Weather and Climate Extremes Impact on Power System Outage

This paper provides statistical analysis of the characteristics of power system outages to gain a better understanding of the impacts of the increasing severe weather conditions on the outages. 10-year historical power system outage data from the Bonneville Power Administration (BPA) were gathered together with co-located weather attributes and recorded extreme weather events in the service area, which are paired in comparable spatial and temporal scales, with a focus on each outage transmission line. Statistical frequency analysis and cross-tabular evaluation are performed to investigate the occurring frequency and duration of outages associated with extreme weather in this area of study. The study reveals that the weather-related outages can be mainly attributed to hail and thunderstorm events which correspond to up to 60% out of all failures in several transmission line types.

Ren, Huiying↗

Quantifying the Uncertainty of the Future Hydrological Impacts of Climate Change: Comparative Analysis of an Advanced Hierarchical Sensitivity in Humid and Semiarid Basins

Comparison and quantification of different uncertainties of future climate change involved in the modeling of a hydrological system are highly important for both hydrological modelers and policy-makers. However, few studies have accurately estimated the relative importance of different sources of uncertainty at different spatiotemporal scales. Here, a hierarchical sensitivity analysis framework (HSAF) incorporated with a variance-based global sensitivity analysis is developed to quantify the spatiotemporal contributions of different uncertainties in hydrological impacts of climate change in two different climatic (humid and semiarid) basins in China. The uncertainty sources include three emission scenarios (ESs), 20 global climate models (GCs), three hydrological models (HMs), and the associated sensitive hydrological parameters (PAs) screened and sampled by the Morris and Latin hypercube sampling methods, respectively. Further, the results indicate that the overall trend of uncertainty is PA > HM > GC > ES, but their uncertainties have discrepancies in projections of different hydrological variables. The HM uncertainty in annual and monthly discharge projections is generally larger than the PA uncertainty in the humid basin than semiarid basin. The PA has greater uncertainty in extreme hydrological event (annual peak discharge) projections than in annual discharge projections for both basins (particularly for the humid basin), but contributes larger uncertainty to annual and monthly discharge projections in the semiarid basin than humid basin. The GC contributes larger uncertainty in all the hydrological variables projections in the humid basin than semiarid basin, while the ES uncertainty is rather limited in both basins. Overall, our results suggest there is greater spatiotemporal variability of hydrological uncertainty in more arid regions.

54 ENVIRONMENTAL SCIENCES↗

Oppenheimer Study Center Solar Analysis

The thermal solar array on the roof of the Oppenheimer Study Center (03-0207) has been defunct and aging progressively worse for years. This study set out to investigate the current state of the abandoned solar array, its various connected systems, and the viability of replacing the array with modern PV panels. This will help offset the energy usage of the building and bring the building in line with upcoming LANL goals of electrification and net-zero emissions (Exec. Order 14057, Sec. 201-5). This study is intended to be a high level, over-the-shoulder, analysis of impact and feasibility, and shall not be considered as an approved design. Further detailed design and analysis will be necessary beyond the concept feasibility phase of this project.

14 SOLAR ENERGY↗

Machine learning-based analysis of COVID-19 pandemic impact on US research networks

Here in this study we explore how fallout from the changing public health policy around COVID-19 has changed how researchers access and process their science experiments. Using a combination of techniques from statistical analysis and machine learning, we conduct a retrospective analysis of historical network data for a period around the stay-at-home orders that took place in March 2020. Our analysis takes data from the entire ESnet infrastructure to explore DOE high-performance computing (HPC) resources at OLCF, ALCF, and NERSC, as well as User sites such as PNNL and JLAB. We look at detecting and quantifying changes in site activity using a combination of t-Distributed Stochastic Neighbor Embedding (t-SNE) and decision tree analysis. Our findings bring insights into the working patterns and impact on data volume movements, particularly during late-night hours and weekends.

97 MATHEMATICS AND COMPUTING↗

Hydropower Potential at Non-Powered Dams: A Multi-Criteria Decision Analysis Tool based on Grid, Community, Industry, and Environmental Impacts

Non-powered dams (NPDs) are dams that do not include hydraulic turbine (hydropower) equipment. Currently, there are more than 80,000 such dams in the United States, which provide a variety of non-energy benefits, including flood control, water supply, navigation, and recreation. Approximately 500 of these NPDs are identified as having the potential to add hydropower generation (totaling up to a capacity of more than 8200 MW). A large share of investment costs and environmental impacts of dam construction have already been incurred at these NPDs. Hence, adding power to the existing dam structure is hypothesized to be achieved at a lower cost, with less risk, and a shorter timeframe than the development required for new dam construction. The abundance of NPDs, the associated environmental favorability, and cost advantages, combined with the reliability, predictability, and dispatchability of hydropower, make NPDs a strong candidate in the nation’s renewable energy portfolio. To assess the NPD to hydropower conversion potential, in this study, we developed a GIS-based multi-criterial decision analysis tool, which allows users to rank these NPDs based on the grid, community, industry, and environmental impacts (i.e., GCIE impacts). This web-based interactive tool (developed using open-source Python and JavaScript) lets the user choose from a wide range of features to define each of the GCIE impact scores through a user-friendly graphical user interface. These features are related to dam operation, hydropower generation opportunity, power market economy, social vulnerability and risk, proximity to critical infrastructure and energy generating facilities, environmental concerns (air, water, and critical habitat), and exposure to natural hazards. The overall priority score of NPDs is calculated based on user-defined weights for each of the GCIE impact scores. Besides ranking NPDs, the tool can also be used to estimate the energy-storage feasibility (battery, hydrogen, and pump-storage hydropower) at each of the potential sites.

13 HYDRO ENERGY↗

H2FAST: Hydrogen Financial Analysis Scenario Tool [SWR 15-06]

The Hydrogen Financial Analysis Scenario Tool, H2FAST, provides a quick and convenient in-depth financial analysis for hydrogen and nonhydrogen systems and services. H2FAST is available as a downloadable Excel spreadsheet. The model uses a generally accepted accounting principles analysis framework and provides annual projections of income statements, cash flow statements, and balance sheets. H2FAST allows users to generate a side-by-side scenario analysis, where a base system can be tested by varying key operating or financing parameters. Detailed capital structure, taxation, and incentives are included. The model has built-in risk analysis allowing impact assessment of parameters bearing user-specified uncertainty ranges. Financial articulation is presented in graphical and tabular format for the user-specified analysis period. The model is self-documented, with embedded help functions and annotation of input parameters. Note: The model is also flexible for providing analysis for International Financial Reporting Standards by adjusting inputs for compliance with their rules. The H2FAST framework has been used for analysis of a variety of systems, e.g., retail hydrogen refueling stations with incentives analysis, ammonia production, methane pyrolysis, seasonal energy storage, hydrogen fleet operations, electric vehicle charging with time of use rate structures, combined heat and power systems, hydrogen production pathways, and hydrogen transmission and distribution. The example cases available for download are intended to demonstrate model functionality and should be populated with user-specific analysis values such as CapEx, OpEx, and capital structure.

Penev, Michael↗

PR100: Puerto Rico Grid Resilience and Transition to 100% Renewable Energy: Preventing and Responding to Extreme Events

This presentation discusses the aftermath of Hurricane Maria's landfall in Puerto Rico on September 20, 2017. Maria incapacitated Puerto Rico's power systems, leaving the entire island without electricity and access to fresh water. Some parts are still recovering years later. A resilient electric grid is vital to Puerto Rico's security, economy, and way of life.

demand impacts↗

Analysis of Warped April Tag Impacts on Detection and Pose Estimation

This report evaluates the impact of geometric deformation on an April Tag, particularly when warped due to attachment on a curved surface, on its detectability and pose estimation performance. A comparative analysis was conducted using a flat April Tag as a control under identical experimental conditions, which involved recording video sequences with varying viewing angles. For detectability, the warped tag exhibited consistent detection failures at viewing angles beyond 40° and complete failures beyond 60°, whereas the flat tag maintained reliable detection across all angles. For pose estimation, measured by pose jitter (variation in rotation and translation), differences between the warped and flat tags were minimal and statistically insignificant, indicating robust performance even for the deformed tag. These findings suggest that while geometric warping reduces an April Tag’s detectability, its pose estimation accuracy remains relatively unaffected under the tested conditions.

42 ENGINEERING↗