Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “directional heat flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Regional earth-atmosphere energy balance estimates based on assimilations with a GCM

The Oort and Vonder Haar (1976) column-budget technique is presently used to evaluate the physical consistency and accuracy of regional earth-atmosphere energy balance estimates for (1) atmospheric budget terms, (2) net radiation at the top of the atmosphere, and (3) time tendency and flux divergence of energy, for Special Observing Periods of the FGGE year. It is found that, during winter, the midlatitude oceans supply large quantities of energy to the overlying atmosphere, which then transports the energy to the continental heat-sinks; the energy flows in the opposite direction during summer.

Alexander, Michael A.↗

Curie isotherm surfaces inferred from high-altitude magnetic anomaly data

Two-dimensional Curie depth models along two sections across the western United States are derived using an equivalent layer magnetization model derived from Magsat data, and the results are used to constrain finite element thermal models developed by Mayhew and Majer (1980). Regional heat flow variations predicted by the models compare favorably with those inferred from direct measurements. The methodology is applied to upward-continued aeromagnetic data, and the results are found to be in good agreement with previous Curie depth estimates and average measured heat flow.

Mayhew, M. A.↗

Significance of the Direct Excitation Mechanism for High-Frequency Response of Premixed Flames to Flow Oscillations

Premixed flames are sensitive to flow disturbances, which can arise from acoustic or vortical fluctuations. For transverse instabilities, it is known that a dominant mechanism for flame response is “injector coupling,” whereby pressure oscillations associated with transverse waves excite axial flow disturbances. These axial flow disturbances then excite heat release oscillations. The objective of this paper is to consider another mechanism—the direct sensitivity of the unsteady heat release to transverse acoustic waves—and to compare its significance relative to the induced axial disturbances, in a linear framework. The rate at which the flame adds energy to the disturbance field is quantified using the Rayleigh criterion and evaluated over a range of control parameters, such as flame length and swirl number. The results show that radial modes induce heat release fluctuations that always add energy to the acoustic field, whereas heat release fluctuations induced by mixed radial-azimuthal modes can add or remove energy. These amplification rates are then compared to the flame response from induced axial fluctuations. For combustor-centered flames, these results show that the direct excitation mechanism has negligible amplification rates relative to the induced axial mechanism for radial modes. For transverse modes, the fact that the nozzle is located at a pressure node indicates that negligible induced axial velocity disturbances are excited; as such, the direct mechanism dominates. As a result, for flames that are not centered on pressure nodes, the direct mechanism for mixed modes dominates for certain nozzle locations and flame angles.

42 ENGINEERING↗

Plume-Free Stream Interaction Heating Effects During Orion Crew Module Reentry

During reentry of the Orion Crew Module (CM), vehicle attitude control will be performed by firing reaction control system (RCS) thrusters. Simulation of RCS plumes and their interaction with the oncoming flow has been difficult for the analysis community due to the large scarf angles of the RCS thrusters and the unsteady nature of the Orion capsule backshell environments. The model for the aerothermal database has thus relied on wind tunnel test data to capture the heating effects of thruster plume interactions with the freestream. These data are only valid for the continuum flow regime of the reentry trajectory. A Direct Simulation Monte Carlo (DSMC) analysis was performed to study the vehicle heating effects that result from the RCS thruster plume interaction with the oncoming freestream flow at high altitudes during Orion CM reentry. The study was performed with the DSMC Analysis Code (DAC). The inflow boundary conditions for the jets were obtained from Data Parallel Line Relaxation (DPLR) computational fluid dynamics (CFD) solutions. Simulations were performed for the roll, yaw, pitch-up and pitch-down jets at altitudes of 105 km, 125 km and 160 km as well as vacuum conditions. For comparison purposes (see Figure 1), the freestream conditions were based on previous DAC simulations performed without active RCS to populate the aerodynamic database for the Orion CM. Other inputs to the analysis included a constant Orbital reentry velocity of 7.5 km/s and angle of attack of 160 degrees. The results of the study showed that the interaction effects decrease quickly with increasing altitude. Also, jets with highly scarfed nozzles cause more severe heating compared to the nozzles with lower scarf angles. The difficulty of performing these simulations was based on the maximum number density and the ratio of number densities between the freestream and the plume for each simulation. The lowest altitude solutions required a substantial amount of computational resources (up to 1800 processors) to simulate approximately 2 billion molecules for the refined (adapted) solutions.

Marichalar, J.↗

A multi-dimensional dataset for two-phase instability in low pressure natural circulation based on direct transient local measurement

Thermal hydraulic instability can challenge the control and the safety of nuclear reactors. This experimental research captures and investigates the instability in a low-pressure (1–10 atmospheres) natural circulation loop with an adiabatic chimney installed above the heated section. Direct transient local measurement of two-phase flow is performed at multiple axial locations along the flow channel with thermocouples and conductivity probes traversed by customized high-precision mechanisms. Based on the periodicity of oscillations, a post-processing method is proposed to align the data captured non-simultaneously to reconstruct the instability behavior in one representative period. The averaging operation over multiple oscillation cycles is performed to reduce the random errors. Cyclic phenomena are clearly demonstrated by the post-processed data, and rapid void fraction change induced by the flashing is observed to be significant in the driving mechanism for low pressure oscillations. Parametric effects of inlet subcooling, heat flux, inlet flow restriction and system pressure are studied within the experiment range, and qualitative results are explained and compared with existing literature. The ratio between the oscillation period and the travelling time of the fluid particle through the test section is compared with the theoretical value for the density wave oscillation. The new dataset contains directly measured transient multi-dimensional two-phase data along the flow channel for natural circulation under density wave oscillations. The generated dataset is valuable for the validation of system analysis codes and CFD codes in the simulation of natural circulation phenomena and dynamic two-phase flow.

42 ENGINEERING↗

Investigation of Flux Spreading in a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on increasing the operating temperatures to accommodate high efficiency power cycles and thermochemical processes. Inert solid particles as heat transfer media enable solar receivers to operate above 700 degrees Celsius resulting in increased system thermal efficiency compared to the conventional molten salt based CSP system. An open-cavity falling-particle solar receiver that can efficiently heat particles by direct heating from concentrated solar radiation faces challenges with large particle losses from wind and unable to support thermochemical reactions. A light-trapping, planar cavity reiver (LTPCR) where particles are indirectly heated can significantly minimize the particle losses during the operation, support thermochemical reactions, and offer scalability potential. The LTPCR features an array of vertical planar receiver/absorber panels arranged within a cavity configuration. Concentrated solar radiation from heliostats is focused onto the receiver walls, where heat is indirectly transferred to solid particles flowing inside the receiver channels. Heat transfer occurs through direct contact between the receiver panel walls and particles, and can be enhanced by fluidizing particles with air. This fluidization increases particle-wall contact and extends particle residence time, maximizing heat transfer efficiency. The unique vertical planar receiver structure originated from a near-blackbody tubular light absorber, effectively distributing the incoming solar beam spread across the panel walls and trapping light. This flux spreading effect, driven by cosine projection, converts high incident solar flux into a lower, more uniform heat flux on the panel walls. This redistribution enhances heat transfer efficiency between particle-wall or reaction gases-wall, while preventing localized overheating of the receiver panel. Indirect planar cavity solar receivers completely separate solid particles from the ambient environment that can greatly reduce the thermal losses in heated particles resulting in high efficiency at high temperatures above 700 degrees Celsius. This design ensures no particle losses to the environment during the operation while open-cavity designs can experience significant particle losses from wind. An experimental investigation was conducted to observe flux spreading on the receiver panel wall. A lab-scale prototype planar receiver, fabricated using Haynes 230 alloy, was tested under direct concentrated solar radiation using the high-flux solar furnace (HFSF) facility at NREL. The experiment was performed under normal peak radiative heat fluxes ranging from 800 to 1900 kW/m2. A temperature distribution on the panel wall was measured using a thermal imaging camera (FLIR A 6600). To prevent overheating at the receiver front tip, prism-shaped heat shields (Zircar UNIFROM C1) were placed in front of the receiver, and their influence on flux spreading was also studied. Absorbed flux distribution on the panel wall was modeled using SolTrace. The total solar power and flux distributions delivered from HFSF were determined based on the heliostat mirror optical properties, direct normal irradiance (DNI) on the on-sun testing days, peak flux measurement during the on-sun testing, and shutter/attenuator settings Due to the large incident angles of the solar beam on the panel wall, the angular optical properties of Haynes 230 alloy and Zircar heat shields were incorporated into the model. This flux distribution model was then integrated into a computational fluid dynamics (CFD) simulation to predict the receiver panel wall temperature, which was compared with the experimental measurements. Both prediction and measurements identified a temperature hotspot at the backside of the panel, indicating that the incident solar beam can fully reach to the rear of the receiver. The heat shields positioned at the front of the receiver effectively reduced the excessive temperature rise at the receiver front tip. Overall, the temperature was well distributed over the panel wall, with a minor hotspot at the back of the receiver. The model slightly overpredicted the temperature, possibly due to discrepancies in optical properties of the panel and an underprediction of thermal loss in the receiver. The advancement of the particle LTPCR offers a viable alternative to open-cavity receivers by addressing particle loss issues. Additionally, it presents a pathway for enabling solar thermochemical processes, extending CSP technology beyond power generation to fuel and chemical production.

14 SOLAR ENERGY↗

Efficient Thermal Energy Storage with Radial Flow in Packed Beds

Thermal energy storage (TES) is a way to store excess heat in order to generate power later. These types of systems are valuable in the solar industry, where power production can still occur when sunlight is not available. This not only increases system flexibility, it drives down the cost of electricity. One option to store thermal energy is with a packed bed where the storage media resides in a cylindrical container. Flow from one end of the cylinder to the other deposits or recovers heat (axial flow). While a promising technology in terms of energy storage, it exhibits a high pressure drop that lowers overall system efficiency. This project seeks to flow the heat transfer fluid through the storage media in the radial direction. This system offers the potential to retain reasonable thermal performance while substantially lowering the pressure drop. The overall goal was to assess the performance of radial flow experimentally and numerically. Three main designs were considered in this work. The first system utilized a central pipe and four receiving pipes near the wall. The second system utilized a central pipe and an annulus with holes near the wall. The last approach considered segmenting the bed so only select zones would receive flow in the radial direction. In a high-aspect ratio system, the hole patterns in the piping are important for ensuring even flow into the bed, and a major design effort was testing holes patterns to promote even flow. The four pipe system was shown to be not feasible, as preferential flow paths occur that do not allow even and full heating of the packed bed. The annular system can lead to even flow, but the results show this is better accomplished through larger piping instead of considering variations in the hole pattern along the axial length of the pipe. Segmenting the bed can lead to similar exergetic performance when compared to axial or radial flow. However, the pressure drop in the segmented design is likely too high for practical implementation. A baseline commercial design showed exergetic efficiencies for axial, radial, and radial segments of 81.6%, 82.8%, and 80.2%, respectively. Pressure drop for the axial and radial results were 2.36 psi and 2.45 psi, respectively, with segments being nearly an order of magnitude higher. At these large scales, the aspect ratio of the system is important. From a baseline of 0.64, an aspect ratio of 0.32 for radial flow showed an exergetic efficiency of 86% but a pressure drop of 5.39 psi. All of these results provide new insights into packed bed thermal energy storage with radial flow. Competing effects must be considered when designing a radial system, and results show a radial design can show strong thermal results at the expense of system efficiencies from pressure drop. The COMSOL models used in this analysis are available to the public and other researchers. Public benefits include a potential increase in the efficiency of packed bed thermal energy storage. Higher efficiency in storage promotes green energy technologies while reducing costs.

14 SOLAR ENERGY↗

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale↗

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale↗

Numerical marching techniques for fluid flows with heat transfer

The finite difference formulation and method of solution is presented for a wide variety of fluid flow problems with associated heat transfer. Only a few direct results from these formulations are given as examples, since the book is intended primarily to serve a discussion of the techniques and as a starting point for further investigations; however, the formulations are sufficiently complete that a workable computer program may be written from them. In the appendixes a number of topics are discussed which are of interest with respect to the finite difference equations presented. These include a very rapid method for solving certain sets of linear algebraic equations, a discussion of numerical stability, the inherent error in flow rate for confined flow problems, and a method for obtaining high accuracy with a relatively small number of mesh points.

Hornbeck, R. W.↗

Heat transfer and pressure drop in blade cooling channels with turbulence promoters

Repeated rib roughness elements have been used in advanced turbine cooling designs to enhance the internal heat transfer. Often the ribs are perpendicular to the main flow direction so that they have an angle-of-attack of 90 deg. The objective of the project was to investigate the effect of rib angle-of-attack on the pressure drop and the average heat transfer coefficients in a square duct with two opposite rib-roughned walls for Reynolds number varied from 8000 to 80,000. The rib height-to-equivalent diameter ratio (e/D) was kept at a constant value of 0.063, the rib pitch-to-height ratio (P/e) was varied from 10 to 20, and the rib angle-of-attack (alpha) was varied from 90 deg to 60 deg to 45 deg to 30 deg respectively. Two types of entrance conditions were examined, namely, long duct and sudden contraction. The heat transfer coefficient distribution on the smooth side wall and the rough side wall at the entrance and the fully developed regions were measured. Thermal performance comparison indicated that the pumping power requirement for the rib with an oblique angle to the flow (alpha = 45 deg to 30 deg) was about 20 to 50 percent lower than the rib with a 90 deg angle to the flow for a given heat transfer duty.

Han, J. C.↗

Testing Bearing Balls For Ignition In Liquid Oxygen

Inexpensive, safe apparatus built to test cooling by, ignition in, and nucleate boiling to film boiling of liquid oxygen flowing around ball bearings. Provides for heating of bearing specimens, direct observations, and measurements of temperatures and temperature distributions by thermocouples and infrared sensors. Used to evaluate suitability of various materials and surface treatments for ball bearings in high-pressure liquid-oxygen turbopumps. Ball rests in fixture while liquid oxygen flows around it. Flow reversed so observer or infrared sensor can view phenomena on trailing or leading side of ball.

Wagner, William R.↗

Experimental Investigation of Flow Orientation Effects on Cryogenic Flow Boiling

Cryogenic flow boiling physics is of paramount importance for future cryogenic space applications employing Cryogenic Fluid Management (CFM) technologies. This experimental study investigates the two-phase flow and heat transfer performance of LN 2 flow boiling across five distinct flow orientations: vertical upflow, vertical downflow, horizontal flow, 45° inclined upflow, and 45° inclined downflow. The study employed the steady- state heating method within a circular heated tube featuring an 8.5-mm inner diameter and a 680-mm heated length. High-speed video recordings were utilized to capture two-phase flow patterns and interfacial behaviors across various flow orientations. The experiments covered a wide range of operating conditions, including mass velocities ranging from 351.80 to 1572.77 kg/m 2 s and inlet pressures from 297.14 to 1032.97 kPa, primarily with near-saturated inlet subcooling. Distinct two-phase flow patterns and regime transitions were identified for each flow orientation. Symmetrical flow patterns were evident in vertical orientations, whereas non-vertical orientations exhibited asymmetric flow stratifications, primarily influenced by the buoyancy force in a terrestrial gravity environment. Bubble dynamic parameters were quantified, and bubble collision and dispersion phenomena were visualized. Analyzing heat transfer performance based on local flow boiling curves and variations in heat transfer coefficients (HTCs), it was observed that vertical upflow demonstrated the most enhanced heat transfer performance, while vertical downflow exhibited the lowest. As mass velocity exceeded 830 kg/ m 2 s, the differences in heat transfer among orientations became less distinct, emphasizing the role of flow inertia in mitigating the influence of flow orientation. A direct comparison of microgravity HTC data from a recent study by the authors against the 1-𝘨 e HTC data indicated enhanced heat transfer performance in microgravity for flow orientation configurations in terrestrial gravity. However, this enhancement progressively diminished as the heat flux increased. Distinct HTC trends were observed as mass velocity increased for different flow orientations and gravity levels.

Cryogens↗

Turbulent Rotating Rayleigh–Bénard Convection

Rotation with thermally induced buoyancy governs many astrophysical and geophysical processes in the atmosphere, ocean, sun, and Earth's liquid-metal outer core. Rotating Rayleigh–Bénard convection (RRBC) is an experimental system that has features of rotation and buoyancy, where a container of height H and temperature difference Δ between its bottom and top is rotated about its vertical axis with angular velocity Ω. The strength of buoyancy is reflected in the Rayleigh number (~ H 3 Δ) and that of the Coriolis force in the Ekman and Rossby numbers (~Ω -1 ). Rotation suppresses the convective onset, introduces instabilities, changes the velocity boundary layers, modifies the shape of thermal structures from plumes to vortical columns, affects the large-scale circulation, and can decrease or enhance global heat transport depending on buoyant and Coriolis forcing. RRBC is an extremely rich system, with features directly comparable to geophysical and astrophysical phenomena. Here we review RRBC studies, suggest a unifying heat transport scaling approach for the transition between rotation-dominated and buoyancy-dominated regimes in RRBC, and discuss non-Oberbeck–Boussinesq and centrifugal effects.

42 ENGINEERING↗

Quick calculation method for fluid flow through duct systems

Conditions for subsonic compressible flow through duct systems are quickly and easily calculated using compact series of curves showing dimensionless parametric functions of Mach number and specific heat ratio. Method is directly applicable to analysis and design of compressible flow systems in industrial fields or processes.

Scott, L. R., Jr.↗

Age alters the cardiovascular response to direct passive heating

During direct passive heating in young men, a dramatic increase in skin blood flow is achieved by a rise in cardiac output (Qc) and redistribution of flow from the splanchnic and renal vascular beds. To examine the effect of age on these responses, seven young (Y; 23 +/- 1 yr) and seven older (O; 70 +/- 3 yr) men were passively heated with water-perfused suits to their individual limit of thermal tolerance. Measurements included heart rate (HR), Qc (by acetylene rebreathing), central venous pressure (via peripherally inserted central catheter), blood pressures (by brachial auscultation), skin blood flow (from increases in forearm blood flow by venous occlusion plethysmography), splanchnic blood flow (by indocyanine green clearance), renal blood flow (by p-aminohippurate clearance), and esophageal and mean skin temperatures. Qc was significantly lower in the older than in the young men (11.1 +/- 0.7 and 7.4 +/- 0.2 l/min in Y and O, respectively, at the limit of thermal tolerance; P < 0. 05), despite similar increases in esophageal and mean skin temperatures and time to reach the limit of thermal tolerance. A lower stroke volume (99 +/- 7 and 68 +/- 4 ml/beat in Y and O, respectively, P < 0.05), most likely due to an attenuated increase in inotropic function during heating, was the primary factor for the lower Qc observed in the older men. Increases in HR were similar in the young and older men; however, when expressed as a percentage of maximal HR, the older men relied on a greater proportion of their chronotropic reserve to obtain the same HR response (62 +/- 3 and 75 +/- 4% maximal HR in Y and O, respectively, P < 0.05). Furthermore, the older men redistributed less blood flow from the combined splanchnic and renal circulations at the limit of thermal tolerance (960 +/- 80 and 720 +/- 100 ml/min in Y and O, respectively, P < 0. 05). As a result of these combined attenuated responses, the older men had a significantly lower increase in total blood flow directed to the skin.

Clinical Trial↗

High speed butt joining of 1” thick 2139-T8

Thick plate (=1”) butt joining of Al alloys is challenging due to high tool forces, uneven material flow, and heat distribution in the through-thickness direction. Tool design and welding parameters used for executing thick plate butt joining have remained mostly static over the past decade. Reported welding speeds that produce viable joint strength (mostly on 6xxx alloys) typically range below 100 mm/min (4inches /min). Researchers at Pacific Northwest National Laboratory (PNNL) in association with Ground Vehicle Systems Center (US Army GVSC) have been working to demonstrate greater joining efficiency at higher welding speeds in a 1” thick AA2139-T8 plate. Using innovative tool features and effective force and temperature control a joint efficiency of 80% was demonstrated at a welding speed of 7 inches /min (178mm/min).

Das, Hrishikesh↗

New Facility to Study Unsteady Wake Effects on Turbine Airfoil Heat Transfer

A significant portion of the SSME aerothermal loads program is directed at the heat transfer effects of the unsteady flows, particularly wakes, that occur naturally in turbomachinery. Although these phenomena occur in all turbomachines, we feel they will be more severe in the SSME turbines because of the high heat transfer associated with the very high Reynolds numbers over the SSME airfoils.

Simoneau, R. J.↗