Abstract

Concentrating solar thermal power (CSP) technology development has recently focused on increasing the operating temperatures to accommodate high efficiency power cycles and thermochemical processes. Inert solid particles as heat transfer media enable solar receivers to operate above 700 degrees Celsius resulting in increased system thermal efficiency compared to the conventional molten salt based CSP system. An open-cavity falling-particle solar receiver that can efficiently heat particles by direct heating from concentrated solar radiation faces challenges with large particle losses from wind and unable to support thermochemical reactions. A light-trapping, planar cavity reiver (LTPCR) where particles are indirectly heated can significantly minimize the particle losses during the operation, support thermochemical reactions, and offer scalability potential. The LTPCR features an array of vertical planar receiver/absorber panels arranged within a cavity configuration. Concentrated solar radiation from heliostats is focused onto the receiver walls, where heat is indirectly transferred to solid particles flowing inside the receiver channels. Heat transfer occurs through direct contact between the receiver panel walls and particles, and can be enhanced by fluidizing particles with air. This fluidization increases particle-wall contact and extends particle residence time, maximizing heat transfer efficiency. The unique vertical planar receiver structure originated from a near-blackbody tubular light absorber, effectively distributing the incoming solar beam spread across the panel walls and trapping light. This flux spreading effect, driven by cosine projection, converts high incident solar flux into a lower, more uniform heat flux on the panel walls. This redistribution enhances heat transfer efficiency between particle-wall or reaction gases-wall, while preventing localized overheating of the receiver panel. Indirect planar cavity solar receivers completely separate solid particles from the ambient environment that can greatly reduce the thermal losses in heated particles resulting in high efficiency at high temperatures above 700 degrees Celsius. This design ensures no particle losses to the environment during the operation while open-cavity designs can experience significant particle losses from wind. An experimental investigation was conducted to observe flux spreading on the receiver panel wall. A lab-scale prototype planar receiver, fabricated using Haynes 230 alloy, was tested under direct concentrated solar radiation using the high-flux solar furnace (HFSF) facility at NREL. The experiment was performed under normal peak radiative heat fluxes ranging from 800 to 1900 kW/m2. A temperature distribution on the panel wall was measured using a thermal imaging camera (FLIR A 6600). To prevent overheating at the receiver front tip, prism-shaped heat shields (Zircar UNIFROM C1) were placed in front of the receiver, and their influence on flux spreading was also studied. Absorbed flux distribution on the panel wall was modeled using SolTrace. The total solar power and flux distributions delivered from HFSF were determined based on the heliostat mirror optical properties, direct normal irradiance (DNI) on the on-sun testing days, peak flux measurement during the on-sun testing, and shutter/attenuator settings Due to the large incident angles of the solar beam on the panel wall, the angular optical properties of Haynes 230 alloy and Zircar heat shields were incorporated into the model. This flux distribution model was then integrated into a computational fluid dynamics (CFD) simulation to predict the receiver panel wall temperature, which was compared with the experimental measurements. Both prediction and measurements identified a temperature hotspot at the backside of the panel, indicating that the incident solar beam can fully reach to the rear of the receiver. The heat shields positioned at the front of the receiver effectively reduced the excessive temperature rise at the receiver front tip. Overall, the temperature was well distributed over the panel wall, with a minor hotspot at the back of the receiver. The model slightly overpredicted the temperature, possibly due to discrepancies in optical properties of the panel and an underprediction of thermal loss in the receiver. The advancement of the particle LTPCR offers a viable alternative to open-cavity receivers by addressing particle loss issues. Additionally, it presents a pathway for enabling solar thermochemical processes, extending CSP technology beyond power generation to fuel and chemical production.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jeong, Shin Young [National Laboratory of the Rockies, Golden, CO (United States)], Shah, Munjal Purnkant [National Laboratory of the Rockies, Golden, CO (United States)] (ORCID:0000000261206016), Martinek, Janna [National Laboratory of the Rockies, Golden, CO (United States)], Ma, Zhiwen [National Laboratory of the Rockies, Golden, CO (United States)] (ORCID:0000000337188038). 2026-08-11. Investigation of Flux Spreading in a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating. https://doi.org/10.66816/pr4048338

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Heliostat sizing methodology for concentrating solar thermal industrial process heat projects

This study presents a method to obtain a heliostat size that minimizes the levelized cost of heat (LCOH) of a heliostat-based concentrating solar thermal system for applications of solar heating for industrial processes at operating temperatures from 565 to 1550°C. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model to supplement the previously developed cost models, which we update to reflect current pricing trends. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWh th . Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the LCOH, producing a characteristic U-shaped trend with a robust near-optimal window of 7-20 m 2 ; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats being deployed at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.