Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ampere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design and Manufacturing Processes of Long-Life Hollow Cathode Assemblies

The design and manufacturing processes for Hollow Cathode Assemblies (HCA's) that operate over a broad range of emission currents up to 30 Amperes, at low potentials, with lifetimes in excess of 17,500 hours. The processes include contamination control procedures which cover hollow cathode component cleaning procedures, gas feed system designs and specifications, and hollow cathode activation and operating procedures to thereby produce cathode assemblies that have demonstrated stable and repeatable operating conditions, for both the discharge current and voltage. The HCA of this invention provides lifetimes of greater than 10,000 hours, and expected lifetimes of greater than 17,500 hours, whereas the present state-of-the-art is less than 500 hours at emission currents in excess of 1 Ampere. Stable operation is provided over a large range of operating emission currents, up to a 6:1 ratio, and this HCA can emit electron currents of up to 30 Amperes in magnitude to an external anode that simulates the current drawn to a space plasma at voltages of less than 20 Volts.

Michael J Patterson↗

Process for testing a xenon gas feed system of a hollow cathode assembly

The design and manufacturing processes for Hollow Cathode Assemblies (HCA's) that operate over a broad range of emission currents up to 30 Amperes, at low potentials, with lifetimes in excess of 17,500 hours. The processes include contamination control procedures which cover hollow cathode component cleaning procedures, gas feed system designs and specifications, and hollow cathode activation and operating procedures to thereby produce cathode assemblies that have demonstrated stable and repeatable operating conditions, for both the discharge current and voltage. The HCA of this invention provides lifetimes of greater than 10,000 hours, and expected lifetimes of greater than 17,500 hours, whereas the present state-of-the-art is less than 500 hours at emission currents in excess of 1 Ampere. Stable operation is provided over a large range of operating emission currents, up to a 6:1 ratio, and this HCA can emit electron currents of up to 30 Amperes in magnitude to an external anode that simulates the current drawn to a space plasma, at voltages of less than 20 Volts.

Patterson, Michael J.↗

Vestibular Stochastic Resonance as a Method to Improve Balance Function: Optimization of Stimulus Characteristics

Stochastic resonance (SR) is a mechanism by which noise can assist and enhance the response of neural systems to relevant sensory signals. Application of imperceptible SR noise coupled with sensory input through the proprioceptive, visual, or vestibular sensory systems has been shown to improve motor function. Specifically, studies have shown that that vestibular electrical stimulation by imperceptible stochastic noise, when applied to normal young and elderly subjects, significantly improved their ocular stabilization reflexes in response to whole-body tilt as well as balance performance during postural disturbances. The goal of this study was to optimize the characteristics of the stochastic vestibular signals for balance performance during standing on an unstable surface. Subjects performed a standardized balance task of standing on a block of 10 cm thick medium density foam with their eyes closed for a total of 40 seconds. Stochastic electrical stimulation was applied to the vestibular system through electrodes placed over the mastoid process behind the ears during the last 20 seconds of the test period. A custom built constant current stimulator with subject isolation delivered the stimulus. Stimulation signals were generated with frequencies in the bandwidth of 1-2 Hz and 0.01-30 Hz. Amplitude of the signals were varied in the range of 0- +/-700 micro amperes with the RMS of the signal increased by 30 micro amperes for each 100 micro amperes increase in the current range. Balance performance was measured using a force plate under the foam block and inertial motion sensors placed on the torso and head segments. Preliminary results indicate that balance performance is improved in the range of 10-25% compared to no stimulation conditions. Subjects improved their performance consistently across the blocks of stimulation. Further the signal amplitude at which the performance was maximized was different in the two frequency ranges. Optimization of the frequency and amplitude of the signal characteristics of the stochastic noise signals on maximizing balance performance will have a significant impact in its development as a unique system to aid recovery of function in astronauts after long duration space flight or for people with balance disorders.

Mulavara, Ajitkumar↗

Dissecting Tensor Cores via Microbenchmarks: Latency, Throughput and Numeric Behaviors

Tensor Cores have been an important unit to accelerate Fused Matrix Multiplication Accumulation (MMA) in all NVIDIA GPUs since Volta Architecture. To program Tensor Cores, users have to use either legacy wmma APIs or current mma APIs. Legacy wmma APIs are more easy-to-use but can only exploit limited features and power of Tensor Cores. Specifically, wmma APIs support fewer operand shapes and can not leverage the new sparse matrix multiplication feature of the newest Ampere Tensor Cores. However, the performance of current programming interface has not been well explored. Furthermore, the computation numeric behaviors of low-precision floating points (TF32, BF16, and FP16) supported by the newest Ampere Tensor Cores are also mysterious. In this paper, we explore the throughput and latency of current programming APIs. Further, we intuitively study the numeric behaviors of Tensor Cores MMA and profile the intermediate operations including multiplication, addition of inner product, and accumulation. All codes used in this work can be found in https://github.com/sunlex0717/DissectingTensorCores.

97 MATHEMATICS AND COMPUTING↗

Electron Cooling for the Antiproton Accumulator

A possibility to utilize electron cooling in the Fermilab Antiproton Accumulator (AA) is studied. It is shown that, for the existing stochastic cooling system and 0.5 Ampere x 10 m of electron cooler, the accumulated antiproton current could be increased up to 0.5-1.0 Ampere with required or lower longitudinal and transverse emittances.

43 PARTICLE ACCELERATORS↗

3D modeling of the Staged Z-pinch with the FLASH code

The Staged Z-pinch (SZP) fusion concept is a magneto-inertial compression scheme developed by Magneto-Inertial Fusion Technologies, Inc. (MIFTI), in which small amounts of fusion fuel are brought to fusion-relevant conditions by passing multi-million amperes strong current through a cylindrical shell of high atomic number material. One- and two-dimensional modeling performed by MIFTI with the MACH2 code, suggests that net fusion energy gain can be achieved when currents in the 10 million amperes range compress a 50%-50% mixture of deuterium and tritium gas. In this project we enhance and use the FLASH code to execute high-fidelity, simulations of various SZP configurations, a collaboration between the Flash Center for Computational Science at the University of Rochester and the Laboratory for Laser Energetics, and MIFTI. FLASH is a high-performance computing, multi-physics, radiation magnetohydrodynamic (MHD) code with extended physics capabilities, which is developed at the Flash Center. The goal of this project is to assess the shell/fuel stability of the pinch to two- and three-dimensional MHD instabilities and to utilize FLASH’s extended physics capabilities to understand how extended-MHD effects impact implosion dynamics and plasma conditions at stagnation. The project is a natural extension of an ongoing collaborative effort between MIFTI and the Flash Center through the U.S. DOE Advanced Research Projects Agency-Energy (ARPA-E) BETHE program and can provide MIFTI with simulation capabilities that are currently beyond their reach with MACH2. Ultimately, MIFTI wants FLASH to become one of their simulation workhorses for reliable, high-fidelity SZP platform design. During the project, the Flash Center team developed a suite of in one- and two-dimensional FLASH simulations to model different variants of the SZP platform, performed code-to-code comparisons with MACH2, and used the FLASH code to design and model SZP experiments like the Double Eagle experiments that MIFTI recently performed. Also, the Flash Center team developed the capabilities of FLASH to be able to do three-dimensional simulations of pulsed-power experiments with the code for the first time. Two publications from this effort are currently under review and two more are in preparation. MIFTI has also committed to the use of FLASH for future SZP simulation efforts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric Vehicle Supply Equipment (EVSE) Site Assessment Report for the U.S. Army Corps of Engineers Chena Site Near Fairbanks, Alaska

This report presents an analysis of the requirements for charging station installation and electric vehicle operation at the US Army Corps of Engineers - Chena Site, located in a cold weather climate in the Fairbanks North Star Borough, AK. The report includes findings from a site visit, and a detailed electric vehicle (EV) charging site plan with cost estimates. Cost for three 50-ampere pedestal chargers located on the edge of the existing parking lot is estimated at $\$$53,100, and the cost of three 80-ampere chargers is estimated at $\$$89,400. The authors did not assess the cost of a heated garage. The USACE Chena site reaches extreme cold temperatures of -40 Degrees Celsius (-40 Degrees Fahrenheit) and below in a typical winter, often for days on end. Considerations of operating EVs as well as electrical vehicle supply equipment (EVSE) at this site can be applicable to other cold or extremely cold locations. Interviews with EV users in cold climates and a literature review indicated that EVs operate well but have significantly decreased range compared to 21 Degrees Celsius (70 Degrees Fahrenheit) operations. Some strategies such as prewarming the vehicle while it is plugged in and using heated seats and steering wheel instead of cabin heat, can improve cold weather performance. Storing the EV in a garage would mean the battery and cabin are automatically preheated, the battery would not age as rapidly as when the vehicle is stored outside, and problems with charging the vehicle are less likely. Lowest temperate-rated Electric Vehicle Supply Equipment (EVSE), as electric vehicle chargers are known as, are rated to -40 Degrees Celsius (-40 Degrees Fahrenheit), and sometimes malfunction. No EVSE is rated to the temperatures that USACE Chena site experienced for more than a week in winter 2023-4, of -50 Degrees Celsius (-45 Degrees Fahrenheit) and which are typical for the area. If reliability is a must, entities may want to consider a heated garage to minimize potential problems with charging equipment. There is a companion technical report to this titled "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska" that examines the data on EV and EVSE cold-weather functionality in more detail. (Esparza, Truffer Moudra, and Hodge 2024).

33 ADVANCED PROPULSION SYSTEMS↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Collector/collector guard ring balancing circuit eliminates edge effects

Circuit in which an emitter is maintained opposite a concentric collector and guard structure is achieved by matching the temperature and potential of the guard with that of the collector over the operating range. This control system is capable of handling up to 100 amperes in the guard circuit and 200 amperes in the collectors circuit.

Lieb, D. P.↗

New microelectronic power amplifier

Integrated push-pull power amplifier fabricated on a chip of silicon has interdigitated power transistors and is hermetically encapsulated in a beryllia flat package. It provides current output greater than the nominal 10 amperes from an input current drive of 1 ampere.

New, T. C.↗

Characterization of the 20-Ah nickel-cadmium cell used for energy storage on the Orbiting Astronomical Observatory

Tests were conducted on 20-Ah sealed nickel cadmium cells to evaluate initial and long-term performance at various charge rates, temperatures and voltage-control levels. An average ampere-hour recharge of 103 percent per orbit at 13 C was able to maintain cell capacity; required watt-hour recharge on an orbital basis was 8 to 10 percent greater than required ampere-hour recharge. Cells exhibited an early life burn-in characteristic. A discharge after periods of repetitive cycling yielded two voltage plateaus which were temporarily eliminated by the discharge.

Ford, F. E.↗

Parametric investigation of enclosed keeper discharge characteristics

Volt-ampere discharge characteristics of an enclosed keeper hollow cathode discharge were measured as a function of the mercury flow rate and external circuit impedance. Discharge currents were varied from 0 to 1 ampere and voltages were 7 to 39 volts. Batteries and a vacuum tube control circuit were used to obtain characteristics curves that were independent of power supply impedance. Variation of the neutral flow results in changes in the discharge which interact with the impedance of the external circuit, and under some conditions, give rise to multiple operating points.

Sheheen, T. W.↗

French wind generator systems

The experimental design of a wind driven generator with a rated power of 800 kilovolt amperes and capable of being connected to the main electrical network is reported. The rotor is a three bladed propeller; each blade is twisted but the fixed pitch is adjustable. The asynchronous 800-kilovolt ampere generator is driven by the propeller through a gearbox. A dissipating resistor regulates the machine under no-load conditions. The first propeller on the machine lasted 18 months; replacement of the rigid propeller with a flexible structure resulted in breakdown due to flutter effects.

Noel, J. M.↗

One man electrochemical air revitalization system

An integrated water vapor electrolysis (WVE) hydrogen depolarized CO2 concentrator (HDC) system sized for one man support over a wide range of inlet air conditions was designed, fabricated, and tested. Data obtained during 110 days of testing verified that this system can provide the necessary oxygen, CO2 removal, and partial humidity control to support one man (without exceeding a cabin partial pressure of 3.0 mmHg for CO2 and while maintaining a 20% oxygen level), when operated at a WVE current of 50 amperes and an HDC current of 18 amperes. An evaluation to determine the physical properties of tetramethylammonium bicarbonate (TMAC) and hydroxide was made. This provides the necessary electrolyte information for designing an HDC cell using TMAC.

Huddleston, J. C.↗

Fabrication and testing of sealed silver-zinc cells

A number of Type HS40-7 sealed silver-zinc cells and experimental 40AH sealed silver-zinc cells were fabricated. Cells of each experimental group contained one variation from the standard configuration (HS40-7) cell. Cells from each of five experimental cell groups and cells of the standard configuration were tested to characterize voltage and capacity performance at various discharge rates. The test cells were then subjected to 100 percent DOD Cycle Life Testing at 22 C. Results indicate that material and/or process variations are available which will improve both performance and cycle life of the existing 40 ampere-hour sealed silver-zinc cell configurations. The average cycle life to 50 percent loss of nominal capacity in cells from two (2) of the experimental groups was 150 - 165 cycles. A series of 12 ampere-hour cells was fabricated and tested as part of a program to incorporate the 40AH sealed silver-zinc cell fabrication technology into a cell of smaller size. Base-line configuration cells and experimental variations were produced using the HS40-7 cell fabrication and processing methods adapted to the smaller cell size.

Donnel, C. P., III↗

Gate-assisted turn-off thyristor

1,000-volt, 200-ampere gate-assisted turn-off thyristor has been developed for power circuits requiring high efficiency, small size, and low weight. Design features include shunted cathode for high dV/dt capability. Cathode in interdigitated with dynamic gate for fast, low-loss switching. Operating frequency exceeds 20 kHz with overall energy dissipation of less that 12 mJ per pulse for typical 20-microsecond half-sine waveform. Device has turn-on time of 2 microseconds and turn-off time as short as 3 microseconds with only 2 amperes of gate drive.

Lowry, L. R.↗

Response of lead-acid batteries to chopper-controlled discharge: Preliminary results

The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses up to 25 percent compared to constant current discharges at the same average discharge current of 100 amperes. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-ampere pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

Cataldo, R. L.↗

A review of the thermoelectronic laser energy converter (TELEC) program at Lewis Research Center

The investigation of the Thermoelectronic Laser Energy Converter (TELEC) concept began with a feasibility study of a 1 megawatt sized TELEC system. The TELEC was to use either cesium vapor or hydrogen as the plasma medium. The cesium vapor TELEC appears to be the more practical device studied with an overall calculated conversion efficiency of greater than 48%. Following this study, a small TELEC cell was fabricated which demonstrated the conversion of a small amount of laser power to electrical power. The cell developed a short circuit current of 0.7 amperes and an open circuit voltage, as extrapolated from volt-ampere curves, of about 1.5 volts.

Alger, D. L.↗