Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VALVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Tesla Valve Integration into Propulsion Systems for Water Hammer Mitigation

Water hammer is a pressure surge or wave caused when a liquid in motion is forced to stop or change direction suddenly. Satellite and in-space propulsion systems exhibit this effect when valves, which can pulse several times per second, close quickly to isolate propellant from thrusters. The inherent nature of pulsing thrusters quickly has made water hammer a constant design challenge for these systems. Historically, the standard is to accept that the Maximum Design Pressure (MDP) of the system must account for a full worst case water-hammer event, which can be several times the Maximum Expected Operating Pressure (MEOP). An investigation is being conducted to determine the effectiveness of tesla valves in reducing water hammer amplitudes. Tesla Valves can be used in-line within propulsion systems to allow unrestricted flow in one direction and restricted flow in the opposite direction without the use of added mechanical or electrical components. Tesla valves use fixed internal geometry to allow for this unrestricted and restricted flow. With the increase and capability of Additive Manufacturing (AM), different configurations and concepts of tesla valves can be manufactured and tested at minimal cost. This concept could possibly be used to allow for a less complicated, or robust satellite and in-space propulsion system. This presentation will cover topics of additive manufactured design of tesla valves, testing, and variables to consider within tesla valve creation.

Michael A Willis↗

Apparatus comprising magnetically actuated valves and uses thereof

The present invention, in part, relates to an apparatus having a single-use, normally-closed fluidic valve that is initially maintained in the closed position by a valve element bonded to an adhesive coating. The valve is opened using a magnetic force. The valve element includes a magnetic material or metal. In some examples, the valve is opened by bringing a magnet in proximity to the valve element to provide a magnetic force that delaminates the valve element from the adhesive coating. In particular, the apparatus can be useful for on-chip amplification and/or detection of various targets, including biological targets and any amplifiable targets. Such apparatuses and methods are useful for in-field or real-time detection of targets, especially in limited resource settings.

42 ENGINEERING↗

Valve train system for an internal combustion engine

A valve train system for an internal combustion engine includes an exhaust valve moveable between an exhaust closed position and an exhaust open position. A camshaft includes a main exhaust lobe for moving the exhaust valve between the exhaust closed position and the exhaust open position for expelling exhaust constituents from the combustion chamber and an exhaust rebreath lobe for moving the exhaust valve between the exhaust closed position and the exhaust open position for allowing exhaust constituents into the combustion chamber. A two-step device is provided for transmitting motion from the camshaft to the exhaust valve and is switchable between a motion transmitting position and a motion preventing position such that the motion transmitting position allows motion to be transmitted from the exhaust rebreath lobe to the exhaust valve and the motion preventing position prevents motion from being transmitted from the exhaust rebreath lobe to the exhaust valve.

Knauf, Michael B.↗

Predictive valve control system

A pressure control system may include a plurality of inflatable objects, each of the inflatable objects having a respective pressure sensor and a respective inflation valve, wherein each of the inflation valves has a behavior profile predictive of an amount of current used by the valve when operated. A valve controller of the system may have a pressure management circuit that receives information from the pressure sensors and is configured to automatically maintain a respective selected pressure in each of the inflatable objects by issuing commands to operate the inflation valves. An electrical current management circuit of the valve controller may be configured to predict, based on the valve behavior profiles, what effect the command would have on a total current usage, when executed, and automatically prevent any command that would cause the total current usage to exceed a maximum allowable current.

Piraner, Alexander↗

Design of a SMART Valve Testbed for Nuclear Thermal Dispatch

By the year 2050, the United States aims to achieve net-zero carbon emissions. To achieve this target, the licensing of the Light Water Reactor (LWR) fleet has been extended for 20 more years. To stay economically competitive with other power sources such as renewable and fossil-fuel power plants, the U.S. Department of Energy has introduced a plan to modernize the existing LWR fleet and diversify the revenue stream. One of the plans is to dispatch thermal energy to endothermic industrial processes. SMART valves will play an important role in this initiative by efficiently balancing the load by regulating valves in a coordinated manner while monitoring the thermal-hydraulic systems to enhance safety and maintain the integrity of the power plant. This research aims to develop a facility to test the coordinated control algorithm and produce various test results for training the monitoring system. The constructed facility is capable of simulating various operational and accidental scenarios by coordinating all the valves (positions) and pump (flowrate). The facility is developed with an Internet of Things (IoT)-based custom system and a python-based valve position control and coordination mechanism. It has achieved stable sensor outputs, pump control, and coordinated valve regulation in all three valves with minimum obstruction in the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

The Onco-cardiologist Dilemma: to Implant, to Defer, or to Avoid Transcatheter Aortic Valve Replacement in Cancer Patients with Aortic Stenosis?

Purpose of Review: Aging is associated with an increased prevalence of both cancer and heart disease. The progression of aortic valve calcification to aortic stenosis may be accelerated by both cardiovascular risk factors and cancer treatments, such as radiotherapy with mediastinal involvement. Symptomatic aortic stenosis is occasionally diagnosed in cancer patients undergoing cardiovascular evaluation; likewise, cancer is often recognized during assessment preceding aortic valve interventions. In these complex cases, physicians face difficult treatment decisions. Due to a myriad of clinical presentations of cancer and valve disease, specific guidelines for this patient population are not currently in place. Management is currently based on clinical judgment, on an individual basis. Recent Findings: Patients with cancer in remission or with a favorable prognosis should be treated according to current cardiovascular guidelines. In these patients, aortic valve replacement can be performed either by surgery or transcatheter. Significant challenges arise in patients with active cancer, especially those receiving anti-cancer treatment. Recent data suggests that these patients can be offered aortic valve replacement, with a trend of favoring the transcatheter route in order to minimize perioperative risk and complications associated with major surgery. Patients with advanced cancer and severe aortic stenosis should be offered palliative care and can benefit from aortic balloon valvuloplasty if indicated. Modern cancer treatments associated with improved long-term prognosis may allow the appropriate cure of aortic stenosis. Summary: We discuss the protocol, outcomes, and evolving recommendations of aortic valve replacement in cancer patients with aortic stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic response of a freely rotating butterfly valve in the advanced test reactor – dynamic fluid-body interaction modeling

To regulate primary coolant flow in the Advanced Test Reactor (ATR), a butterfly valve was installed between the primary coolant pumps and the reactor core. If the mechanical connection between the valve's disk and its shaft ever fails, the disk will rotate freely. Rapid disk rotation may induce pressure surges that could damage upstream pipes. In the present work, the rotational trajectory and pressure evolution during a disk free-rotation scenario were analyzed via the dynamic fluid-body interaction (DFBI) approach in STAR-CCM+, with the movement of a solid being driven by the forces and moment/torque imposed by its surrounding fluid. Assuming a large initial opening angle, the disk accelerates slowly, but swiftly passes the closed position. As a result of the sudden valve closure, a pressure surge occurs in the upstream pipes, exceeding their maximum allowable pressure. Furthermore, the disk does not stabilize at the closed position but continually oscillates due to the unsteady nature of the coolant flow. Because of the significant and continuous water hammer effect, a fix to the butterfly valve is being implemented to prevent rapid valve closure due to failure at the valve's disk/shaft mechanical connection.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of color Doppler flow mapping to calculate orifice area of St Jude mitral valve

BACKGROUND: The effective orifice area (EOA) of a prosthetic valve is superior to transvalvular gradients as a measure of valve function, but measurement of mitral prosthesis EOA has not been reliable. METHODS AND RESULTS: In vitro flow across St Jude valves was calculated by hemispheric proximal isovelocity surface area (PISA) and segment-of-spheroid (SOS) methods. For steady and pulsatile conditions, PISA and SOS flows correlated with true flow, but SOS and not PISA underestimated flow. These principles were then used intraoperatively to calculate cardiac output and EOA of newly implanted St Jude mitral valves in 36 patients. Cardiac output by PISA agreed closely with thermodilution (r=0.91, Delta=-0.05+/-0.55 L/min), but SOS underestimated it (r=0.82, Delta=-1.33+/-0.73 L/min). Doppler EOAs correlated with Gorlin equation estimates (r=0.75 for PISA and r=0.68 for SOS, P<0.001) but were smaller than corresponding in vitro EOA estimates. CONCLUSIONS: Proximal flow convergence methods can calculate forward flow and estimate EOA of St Jude mitral valves, which may improve noninvasive assessment of prosthetic mitral valve obstruction.

NASA Discipline Cardiopulmonary↗

Digital Valve for High Pressure High Flow Applications

To address the challenges, which are involved with the development of flow control valves that can meet the requirements of deep oil wells such as high pressure, high flow rate, limited power and limited space, the authors have conceived a novel design configuration [1]. This design consists of a digitalized flow control valve with multipath and multistage pressure reduction structures. Specifically, the valve is configured as a set of parallel flow paths from the inlet to the outlet. A choke valve controls the total flow rate by digitally opening different paths or different combination of the paths. Each path is controlled by a poppet cap valve basically operated in on-off states. The number of flow states is 2N where N is the number of flow paths. To avoid erosion from sand in the oil and high speed flow, the seal area of the poppet cap valve is located at a distance from the flow inlet away from the high speed flow and the speed is controlled to stay below a predefined erosion safe limit. The path is a multistage structure composed of a set of serial nozzles-expansion chambers that equally distribute the total pressure drop to each stage. The pressure drop of each stage and, therefore, the flow speed at the nozzles and expansion chambers is controlled by the number of stages. The paths have relatively small cross section and could be relatively long for large number of stages and still fit in the strict annular space limit of a typical downhole region of an oil well. The paper will present the design configuration, analysis and preliminary test results.

downhole↗

Low Temperature Combustion Exploration with Negative Valve Overlap

Progressively stringent emission regulations and increasing regulatory demands on fuel economy have led to advanced combustion development. Low temperature combustion (LTC), specifically homogenous charge compression ignition (HCCI), is a promising technology for reducing exhaust emissions and improving efficiency. However, its operating range is limited to low load without boosting and EGR, due to low volumetric efficiency and high pressure rise rates. In addition, effectively controlling the combustion phasing is another challenge in realizing the associated combustion gains. In this work, advanced valve control mechanisms known as continuously variable valve duration (CVVD) and continuously variable valve timing (CVVT) were used for both intake and exhaust valvetrains to enable negative valve overlap (NVO) for trapping hot exhaust residuals and to promote multipoint simultaneous ignition. Heat release phasing was controlled by varying the fueling scheme and by adjusting the amount of NVO. Parametric studies on valve timing and duration, fueling strategy, lambda, spark assist, etc., were carried out first. Afterwards the LTC strategy was proposed and then LTC operation was explored at different engine speeds. Various approaches for extending load limits were summarized and discussed. Finally, combustion performance was compared to that of spark ignition combustion, demonstrating the combustion gains of LTC.

02 PETROLEUM↗

Operational Performance Characteristics of an Aerated L-valve Operated Within a Closed Circulating Fluidized Bed Loop

An experimental study was conducted in a large scale circulating fluidized bed (0.3 m diameter ×15.5 m tall) equipped with nonmechanical L-valve (0.25 m diameter ×1.52 m long) varying the riser superficial gas velocity (U g ), bed inventory (m), L-valve aeration velocity (U Lvalve ) and standpipe aeration velocity (U move ). The effects of these operational parameters on pressure drop were investigated in each of the different components in the CFB and on the solid circulation rate with two different Group B particles (180 μm glass bead and 750 μm phosphorescent polyethylene beads, PPE). Tests were carried out at ambient temperature and pressure conditions using air as the fluidization gas. The operating parameters were shown to significantly affect pressure drops across various sections of the CFB due to redistribution of solids within the system. The pressure drop in the horizontal section of the L-valve was affected by aeration rates in addition to the solid flow rate reported in previous studies of smaller L-valves without aeration. A new dimensionless semi-empirical correlation was able to explain > 98% of the variance between pressure drop across the horizontal section of the L-valve and operating parameters for these Group B particles. The results of present study indicated that the nonmechanical L-valve cannot be isolated from the CFB system for performance evaluation.

Monazam, Esmail R.↗

Solenoid actuated driver valve for high repetition rate shock tubes

A high speed, high pressure solenoid actuated valve has been developed for use as a driver section for automated shock tubes. The valve is based on a prior design, and significant improvements in the design of the valve are described in this paper. The new design retains the performance of prior versions of the valve and creates very reproducible reaction conditions in the shock tube, which are illustrated by several thousand experiments. Additionally, the longevity of the valve is improved, failures are reduced, and the maintenance and manufacture of the valve are simplified.

47 OTHER INSTRUMENTATION↗

Massive Gas Injection Valve Development for NSTX-U

NSTX-U research will offer new insight by studying gas assimilation efficiencies for MGI injection from different poloidal locations using identical gas injection systems. In support of this activity, an electromagnetic MGI valve has been built and tested. The valve operates by repelling two conductive disks due to eddy currents induced on them by a rapidly changing magnetic field created by a pancake disk solenoid positioned beneath the circular disk attached to a piston. The current is driven in opposite directions in the two solenoids, which creates a cancelling torque when the valve is operated in an ambient magnetic field, as would be required in a tokamak installation. The valve does not use ferromagnetic materials. Results from the operation of the valve, including tests conducted in 1 T external magnetic fields, are described. The pressure rise in the test chamber is measured directly using a fast time response baratron gauge. At a plenum pressure of just 1.38 MPa (~200 psig), the valve injects 27 Pa.m^3 (~200 Torr.L) of nitrogen with a pressure rise time of 3 ms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detecting Passing Valves at Scale Across Different Buildings and Systems: A Brick Enabled and Mortar Tested Application

Heating hot water distribution systems are typically used in commercial buildings to condition spaces to provide occupant thermal comfort. However, recent research shows significant distribution losses within these systems that drive down the overall hot water plant efficiency. This research focuses on detecting passing valves in reheat coils found in variable air volume (VAV) terminal units to reduce distribution losses. A passing valve allows hot water flow when the actuator on the valve is commanded to be closed. The fluid causes unintentional heating or cooling to occur, causing comfort and control issues, and wasting energy. We developed the passing valve detection algorithm using a framework based on the Brick schema and Mortar platform to ensure that the application is portable and can scale to many buildings. We applied the same application to analyze 1,335 VAV reheat terminal units in 20 buildings. The diversity found in these large datasets increases confidence that any building with VAV reheat terminal units with the required sensors and Brick data model can run our open-source algorithm with little or no modification. In aggregate, 5% of VAV units analyzed were categorized as having a sensor fault, 14% with potential passing valve fault, and 81% with no faults detected. However, there is a significant variation in the proportion of VAV units with a passing valve detected (1% to 83%) of each building’s analyzed units.

Roa, Carlos Duarte↗

Studies for the requirements of automatic and remotely controlled shutoff valves on hazardous liquids and natural gas pipelines with respect to public and environmental safety

This study assesses the effectiveness of block valve closure swiftness in mitigating the consequences of natural gas and hazardous liquid pipeline releases on public and environmental safety. It also evaluates the technical, operational, and economic feasibility and potential cost benefits of installing automatic shutoff valves (ASVs) and remote control valves (RCVs) in newly constructed and fully replaced transmission lines. Risk analyses of hypothetical pipeline release scenarios are used as the basis for assessing: (1) fire damage to buildings and property in Class 1, Class 2, Class 3, and Class 4 high consequence areas (HCAs) caused by natural gas pipeline releases and subsequent ignition of the released natural gas; (2) fire damage to buildings and property in HCAs designated as high population areas and other populated areas caused by hazardous liquid pipeline releases and subsequent ignition of the released propane; and (3) socioeconomic and environmental damage in HCAs caused by hazardous liquid pipeline releases of crude oil. These risk analyses use engineering principles and fire science practices to characterize thermal radiation effects on buildings and humans and to quantify the total damage cost of socioeconomic and environmental impacts. The risk analysis approach used for natural gas pipelines is consistent with risk assessment standards developed by industry and incorporated into Federal pipeline safety regulations. Feasibility evaluations for the hypothetical pipeline release scenarios considered in this study show that installation of ASVs and RCVs in newly constructed and fully replaced natural gas and hazardous liquid pipelines is technically, operationally, and economically feasible with a positive cost benefit. However, these results may not apply to all newly constructed and fully replaced pipelines because site-specific parameters that influence risk analyses and feasibility evaluations often vary significantly from one pipeline segment to another and may not be consistent with those considered in this study. Consequently, the technical, operational, and economic feasibility and potential cost benefits of installing ASVs and RCVs in newly constructed or fully replaced pipelines need to be evaluated on a case-by-case basis. In theory, installing ASVs and RCVs in pipelines can be an effective strategy for mitigating potential consequences of unintended releases because decreasing the total volume of the release reduces overall impacts on the public and to the environment. However, block valve closure has no effect on preventing pipeline failure or stopping the product that remains inside the isolated pipeline segments from escaping into the environment. The benefits in terms of cost avoidance attributed to block valve closure swiftness increase as the time required to isolate the damaged transmission pipeline segment decreases. Block valve closure swiftness is most effective in mitigating damage resulting from a pipeline release and subsequent fire when the damaged pipeline segment is isolated and the thermal radiation produced by the fire declines in time so that emergency responders can safely begin fire fighting activities immediately upon arrival at the scene. Similarly, the avoided cost of socioeconomic and environmental damage for hazardous liquid pipeline releases without ignition increase as time required to isolate the damaged pipeline segment decreases.

03 NATURAL GAS↗

High-performance space shuttle auxiliary propellant valve system

Several potential valve closures for the space shuttle auxiliary propulsion system (SS/APS) were investigated analytically and experimentally in a modeling program. The most promising of these were analyzed and experimentally evaluated in a full-size functional valve test fixture of novel design. The engineering investigations conducted for both model and scale evaluations of the SS/APS valve closures and functional valve fixture are described. Preliminary designs, laboratory tests, and overall valve test fixture designs are presented, and a final recommended flightweight SS/APS valve design is presented.

Smith, G. M.↗

OMS engine shutoff valve and actuation system design and evaluation

Shutoff valve and actuation system concepts that are most suitable for the Orbital Maneuvering Systems engine application were determined. Emphasis was placed on the ten year and 100 mission life requirement, propellant and propellant residue compatibility and weight. It was found that poppet or ball valves utilizing electric or electropneumatic actuation were most applicable. Preliminary design layouts of a number of valve and actuation concepts were prepared and analyzed to make the optimum concept selection. Pneumatic actuation systems were required to feature their own pneumatic supply so that for the quad redundant valve, it was necessary to include two pneumatic supply systems, one for each of the series legs of the quad redundant package. The requirement for the pneumatic package placed heavy reliability, weight, and maintenance penalties upon electropneumatic actuation systems. The two valve and actuation systems concepts selected featured electric torque motor operation and a poppet as well as a ball valve concept with a retractable seal.

Wichmann, H.↗

Spring-Loaded Joule-Thomson Valve

Improved design reduces clogging and maintains constant pressure drop as flow rate varies. Spring-Loaded Joule-Thomson Valve pressure drop regulated by spring pushing stainless-steel ball against soft brass seat. Pressure drop remains nearly constant, regardless of helium flow rate and of any gas contaminants frozen on valve seat. Because springloaded J-T valve maintains constant pressure drop, upstream roomtemperature throttle valve adjusts flow rate precisely for any given upstream pressure. In addition, new valve relatively invulnerable to frozen gas contaminants, which clog fixed-orifice J-T valves.

Jones, J. A.↗